Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME FUNCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

MagicPlate-512: A 2D silicon detector array for quality assurance of stereotactic motion adaptive radiotherapy

Purpose: Spatial and temporal resolutions are two of the most important features for quality assurance instrumentation of motion adaptive radiotherapy modalities. The goal of this work is to characterize the performance of the 2D high spatial resolution monolithic silicon diode array named “MagicPlate-512” for quality assurance of stereotactic body radiation therapy (SBRT) and stereotactic radiosurgery (SRS) combined with a dynamic multileaf collimator (MLC) tracking technique for motion compensation. Methods: MagicPlate-512 is used in combination with the movable platform HexaMotion and a research version of radiofrequency tracking system Calypso driving MLC tracking software. The authors reconstruct 2D dose distributions of small field square beams in three modalities: in static conditions, mimicking the temporal movement pattern of a lung tumor and tracking the moving target while the MLC compensates almost instantaneously for the tumor displacement. Use of Calypso in combination with MagicPlate-512 requires a proper radiofrequency interference shielding. Impact of the shielding on dosimetry has been simulated by GEANT4 and verified experimentally. Temporal and spatial resolutions of the dosimetry system allow also for accurate verification of segments of complex stereotactic radiotherapy plans with identification of the instant and location where a certain dose is delivered. This feature allows for retrospective temporal reconstruction of the delivery process and easy identification of error in the tracking or the multileaf collimator driving systems. A sliding MLC wedge combined with the lung motion pattern has been measured. The ability of the MagicPlate-512 (MP512) in 2D dose mapping in all three modes of operation was benchmarked by EBT3 film. Results: Full width at half maximum and penumbra of the moving and stationary dose profiles measured by EBT3 film and MagicPlate-512 confirm that motion has a significant impact on the dose distribution. Motion, no motion, and motion with MLC tracking profiles agreed within 1 and 0.4 mm, respectively, for all field sizes tested. Use of electromagnetic tracking system generates a fluctuation of the detector baseline up to 10% of the full scale signal requiring a proper shielding strategy. MagicPlate-512 is also able to reconstruct the dose variation pulse-by-pulse in each pixel of the detector. An analysis of the dose transients with motion and motion with tracking shows that the tracking feedback algorithm used for this experiment can compensate effectively only the effect of the slower transient components. The fast changing components of the organ motion can contribute only to discrepancy of the order of 15% in penumbral region while the slower components can change the dose profile up to 75% of the expected dose. Conclusions: MagicPlate-512 is shown to be, potentially, a valid alternative to film or 2D ionizing chambers for quality assurance dosimetry in SRS or SBRT. Its high spatial and temporal resolutions allow for accurate reconstruction of the profile in any conditions with motion and with tracking of the motion. It shows excellent performance to reconstruct the dose deposition in real time or retrospectively as a function of time for detailed analysis of the effect of motion in a specific pixel or area of interest.

60 APPLIED LIFE SCIENCES↗

Codebase release r1.1 for SmoQyDEAC.jl

We introduce the SmoQyDEAC.jl package, a Julia implementation of the Differential Evolution Analytic Continuation (DEAC) algorithm [N. S. Nichols et al., Phys. Rev. E 106, 025312 (2022)] for analytically continuing noisy imaginary time correlation functions to the real frequency axis. Our implementation supports fermionic and bosonic correlation functions on either the imaginary time or Matsubara frequency axes, and treatment of the covariance error in the input data. This paper presents an overview of the DEAC algorithm and the features implemented in the SmoQyDEAC.jl package. It also provides detailed benchmarks of the package’s output against the popular maximum entropy and stochastic analytic continuation methods. The code for this package can be downloaded from our GitHub repository at https://github.com/SmoQySuite/SmoQyDEAC.jl or installed using the Julia package manager. The online documentation, including examples, can be accessed at https://smoqysuite.github.io/SmoQyDEAC.jl/stable/.

Neuhaus, James (ORCID:0000000169048510)↗

Geophysical models of Western Aphrodite-Niobe region: Venus

The new topography and gravitational field data for Venus expressed in spherical harmonics of degree and order up to 50 allow us to analyze the crust-mantle boundary relief and stress state of the Venusian lithosphere. In these models, we consider models in which convection is confined beneath a thick, buoyant lithosphere. We divide the convection regime into an upper mantle and lower mantle component. The lateral scales are smaller than on Earth. In these models, relative to Earth, convection is reflected in higher order terms of the gravitational field. On Venus geoid height and topography are highly correlated, although the topography appears to be largely compensated. We hypothesize that Venus topography for those wavelengths that correlate well with the geoid is partly compensated at the crust-mantle boundary, while for the others compensation may be distributed over the whole mantle. In turn the strong sensitivity of the stresses to parameters of the models of the external layers of Venus together with geological mapping allows us to begin investigations of the tectonics and geodynamics of the planet. For stress calculations we use a new technique of space- and time-dependent Green's response functions using Venus models with rheologically stratified lithosphere and mantle and a ductile lower crust. In the basic model of Venus the mean crust is 50-70 km thick, the density contrast across the crust-mantle boundary is in the range from 0.3 to 0.4 g/cm(exp -3). The thickness of a weak mantle zone may be from 350 to 1000 km. Strong sensitivity of calculated stress to various parameters of the layered model of Venus together with geological mapping and analysis of surface tectonic patterns allow us to investigate the tectonics and geodynamics of the planet. The results are presented in the form of maps of compression-extension and maximum shear stresses in the lithosphere and maps of crust-mantle boundary relief, which can be presented as a function of time. We have modeled the region of Western Aphrodite and the Niobe plains to get reasonable depths of compensation. Crust mantle boundary relief is calculated for Western Aphrodite-Niobe relative to a mean crustal thickness of 50 km. The calculations include the consequences of simple crust models and more complicated models with a weak, ductile lower crust, a strong upper mantle and a weak lower mantle layer.

Marchenkov, K. I.↗

Can quantum transition state theory be defined as an exact t = 0 + limit?

Here, the definition of the classical transition state theory (TST) as a t → 0 + limit of the flux-side time correlation function relies on the assumption that simultaneous measurement of population and flux is a well defined physical process. However, the noncommutativity of the two measurements in quantum mechanics makes the extension of such a concept to the quantum regime impossible. For this reason, quantum TST (QTST) has been generally accepted as any kind of quantum rate theory reproducing the TST in the classical limit, and there has been a broad consensus that no unique QTST retaining all the properties of TST can be defined. Contrary to this widely held view, Hele and Althorpe (HA) recently suggested that a true QTST can be defined as the exact t → 0 + limit of a certain kind of quantum flux-side time correlation function and that it is equivalent to the ring polymer molecular dynamics (RPMD) TST. This work seeks to question and clarify certain assumptions underlying these suggestions and their implications. First, the time correlation function used by HA as a starting expression is not related to the kinetic rate constant by virtue of linear response theory, which is the first important step in relating a t = 0 + limit to a physically measurable rate. Second, a theoretical analysis calls into question a key step in HA’s proof which appears not to rely on an exact quantum mechanical identity. The correction of this makes the true t = 0 + limit of HA’s QTST different from the RPMD-TST rate expression, but rather equal to the well-known path integral quantum transition state theory rate expression for the case of centroid dividing surface. An alternative quantum rate expression is then formulated starting from the linear response theory and by applying a recently developed formalism of real time dynamics of imaginary time path integrals. In conclusion, it is shown that the t → 0 + limit of the new rate expression vanishes in the exact quantum limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Propellant feed systems transients

Program was written to assist in analysis of fluid feed line transients initiated by operation of valves. Program output consists of printout of transient pressures and velocities through feed system as function of time. Optional CRT plot output provides for display of transient pressures and velocities as function of time at any desired location in feed system.

Shumway, R. A.↗

Launch vehicle effluent measurements during the May 12, 1977, Titan 3 launch at Air Force Eastern Test Range

Airborne effluent measurements and cloud physical behavior for the May 21, 1977, Titan 3 launch from the Air Force Eastern Test Range, Fla. are presented. The monitoring program included airborne effluent measurements in situ in the launch cloud, visible and infrared photography of cloud growth and physical behavior, and limited surface collection of rain samples. Airborne effluent measurements included concentrations of HCl, NO, NOx, and aerosols as a function of time in the exhaust cloud. For the first time in situ particulate mass concentration and aerosol number density were measured as a function of time and size in the size range of 0.05 to 25 micro meters diameter. Measurement results were similar to those of earlier launch monitorings. Maximum HCl and NOx concentrations ranged from 10 ppm and 500 ppb, respectively, several minutes after launch to about 1 ppm and 100 ppb at 45 minutes after launch.

Gregory, G. L.↗

Method of solar power prediction

Techniques for estimating direct and diffuse sunlight reaching a location as a function of time using color whole sky images are provided. In one aspect, a method for forecasting solar insolation is provided that includes the steps of: obtaining color whole sky images using a digital camera which are taken at different times, and wherein an image of a solar disk is present in at least one of the color whole sky images; creating sky transparency images from the color whole sky images; determining atmospheric solar scattering based on a width of the solar disk in the color whole sky images; determining cloud motion trajectories from a time series of the sky transparency images; and calculating the solar insolation as a function of time using the sky transparency, the atmospheric solar scattering, and the cloud motion trajectories. A system for forecasting solar insolation is also provided.

Hamann, Hendrik F.↗

ASTM E 1559 method for measuring material outgassing/deposition kinetics has applications to aerospace, electronics, and semiconductor industries

The American Society for Testing and Materials has published a new standard test method for characterizing time and temperature-dependence of material outgassing kinetics and the deposition kinetics of outgassed species on surfaces at various temperatures. This new ASTM standard, E 1559(1), uses the quartz crystal microbalance (QCM) collection measurement approach. The test method was originally developed under a program sponsored by the United States Air Force Materials Laboratory (AFML) to create a standard test method for obtaining outgassing and deposition kinetics data for spacecraft materials. Standardization by ASTM recognizes that the method has applications beyond aerospace. In particular, the method will provide data of use to the electronics, semiconductor, and high vacuum industries. In ASTM E 1559 the material sample is held in vacuum in a temperature-controlled effusion cell, while its outgassing flux impinges on several QCM's which view the orifice of the effusion cell. Sample isothermal total mass loss (TML) is measured as a function of time from the mass collected on one of the QCM's which is cooled by liquid nitrogen, and the view factor from this QCM to the cell. The amount of outgassed volatile condensable material (VCM) on surfaces at higher temperatures is measured as a function of time during the isothermal outgassing test by controlling the temperatures of the remaining QCM's to selected values. The VCM on surfaces at temperatures in between those of the collector QCM's is determined at the end of the isothermal test by heating the QCM's at a controlled rate and measuring the mass loss from the end of the QCM's as a function of time and temperature. This reevaporation of the deposit collected on the QCM's is referred to as QCM thermogravimetric analysis. Isothermal outgassing and deposition rates can be determined by differentiating the isothermal TML and VCM data, respectively, while the evaporation rates of the species can be obtained as a function of temperature by differentiating the QCM thermogravimetric analysis data.

Garrett, J. W.↗

A new approach to the design of time-varying control systems with application to the Space Shuttle Boost

A general approach to the analysis and design of closed-loop control for slowly time-varying linear systems is presented. The approach uses the method of generalized multiple scales in which slow and fast dynamics are systematically separated by employing different 'clocks' which measure time at varying rates. The clocks, which are necessarily nonlinear functions of time, are chosen in such a manner that the system dynamics are asymptotically invariant with respect to the new time scale. A transfer function relating the output to the input for general linear slowly time-varying systems is developed and represents the actual system under certain conditions. The clock function is shown to satisfy an algebraic characteristic equation and can be determined in terms of the coefficients. The approach can be viewed as an extension of time-invariant linear feedback control theory.

Ramanth, R. V.↗

SOFTC: A Software Correlator for VLBI

SOFTC is an advanced software implementation of a signal correlator for very-long-baseline interferometry (VLBI) for measuring positions of natural celestial objects and distant spacecraft. Because of increases in processing speeds of general-purpose computers, software VLBI correlators have become viable alternatives to hardware ones. The input to SOFTC consists of digitized samples of raw VLBI-antenna received- signal voltages. Optionally, SOFTC also tracks calibration tones superimposed on the received signals. The outputs of SOFTC are (1) phases and amplitudes as functions of time and frequency for cross-correlated received signals and (2) phases and amplitudes as functions of time, station, and tone number for the calibration tones. SOFTC was created to be as accurate as possible, capable of processing essentially any VLBI data, pass strong debugging tests, have a simple user interface, and have no platform dependencies. SOFTC is written modularly in the C programming language. The great advantage of implementing a correlator in software, in contradistinction to hardware, is that it becomes relatively easy and much less expensive and time-consuming to adapt, modify, improve, and update the correlator.

Lowe, Stephen↗

UNCERTAINTIES IN GALACTIC CHEMICAL EVOLUTION MODELS

We use a simple one-zone galactic chemical evolution model to quantify the uncertainties generated by the input parameters in numerical predictions for a galaxy with properties similar to those of the Milky Way. We compiled several studies from the literature to gather the current constraints for our simulations regarding the typical value and uncertainty of the following seven basic parameters: the lower and upper mass limits of the stellar initial mass function (IMF), the slope of the high-mass end of the stellar IMF, the slope of the delay-time distribution function of Type Ia supernovae (SNe Ia), the number of SNe Ia per M {sub ⊙} formed, the total stellar mass formed, and the final mass of gas. We derived a probability distribution function to express the range of likely values for every parameter, which were then included in a Monte Carlo code to run several hundred simulations with randomly selected input parameters. This approach enables us to analyze the predicted chemical evolution of 16 elements in a statistical manner by identifying the most probable solutions, along with their 68% and 95% confidence levels. Our results show that the overall uncertainties are shaped by several input parameters that individually contribute at different metallicities, and thus at different galactic ages. The level of uncertainty then depends on the metallicity and is different from one element to another. Among the seven input parameters considered in this work, the slope of the IMF and the number of SNe Ia are currently the two main sources of uncertainty. The thicknesses of the uncertainty bands bounded by the 68% and 95% confidence levels are generally within 0.3 and 0.6 dex, respectively. When looking at the evolution of individual elements as a function of galactic age instead of metallicity, those same thicknesses range from 0.1 to 0.6 dex for the 68% confidence levels and from 0.3 to 1.0 dex for the 95% confidence levels. The uncertainty in our chemical evolution model does not include uncertainties relating to stellar yields, star formation and merger histories, and modeling assumptions.

79 ASTRONOMY AND ASTROPHYSICS↗

A new approach to the design of time varying control systems with application to the space shuttle booster

A general approach toward the analysis and design of closed loop control for slowly time-varying linear systems was investigated. The approach is by the method of generalized multiple scales, in which slow and fast dynamics are systematically separated by employing different clocks which measure time at varying rates. The clocks, which are necessarily nonlinear functions of time, so that the system dynamics are asymptotically invariant with respect to the new time scale. A transfer function relating the output to the input for general linear slowly time-varying systems is developed and represents the actual system under certain conditions. The clock functions are shown to satisfy an algebraic characteristic equation and can be determined in general in terms of the coefficients.

Ramnath, R. V.↗

Thermal Properties of Prominence Motions as Observed in the UV

The mechanisms by which solar prominences are filled with plasma are still undetermined. In this study we perform a quantitative analysis of the thermal properties of moving features in prominences in order to put constraints on models of prominence formation and dynamics. In order to make such measurements of quickly moving features seen in prominences in the UV we use the SOHO instruments SUMER and CDS to take a time series of exposures at a single pointing position, providing a measurement of spectral line properties as a function of time and position along the slit. The resulting observations in spectral lines in a range of 'transition region' temperatures allow us to analyze the thermal properties of the moving prominence sources as a function of time.

Kucera, T.↗

Thermal Properties of Moving UV Features in Prominences

Multi-thermal features with speeds of 5-70 kilometers per second perpendicular to the line of sight are common in the prominences which showed traceable motions. These speeds are noticeably higher than the typical speeds of 5-20 kilometers per second observed in H-alpha data from "quiet" prominences and are more typical of "activated" prominences in which H-alpha blob speeds of up to 40 kilometers per second have been reported. In order to make a more quantitative determination of the thermal properties of the moving features seen in the UV, we use the SOHO instruments SUMER and CDS to take a time series of exposures from a single pointing position, providing a measurement of spectral line properties as a function of time and position along the slit. The resulting observations in lines spectral lines in a range of "transition region" temperatures allow us to analyze the thermal properties of the moving prominence sources as a function of time.

Kucera, Therese A.↗

Enabling Real-Time Volume Rendering of Functional Magnetic Resonance Imaging on an iOS Device

Powerful non-invasive imaging technologies like computed tomography (CT), ultrasound, and magnetic resonance imaging (MRI) are used daily by medical professionals to diagnose and treat patients. While 2D slice viewers have long been the standard, many tools allowing 3D representations of digital medical data are now available. The newest imaging advancement, functional MRI (fMRI) technology, has changed medical imaging from viewing static to dynamic physiology (4D) over time, particularly to study brain activity. Add this to the rapid adoption of mobile devices for everyday work and the need to visualize fMRI data on tablets or smartphones arises. However, there are few mobile tools available to visualize 3D MRI data, let alone 4D fMRI data. Building volume rendering tools on mobile devices to visualize 3D and 4D medical data is challenging given the limited computational power of the devices. This paper describes research that explored the feasibility of performing real-time 3D and 4D volume raycasting on a tablet device. The prototype application was tested on a 9.7” iPad Pro using two different fMRI datasets of brain activity. The results show that mobile raycasting is able to achieve between 20 and 40 frames per second for traditional 3D datasets, depending on the sampling interval, and up to 9 frames per second for 4D data. While the prototype application did not always achieve true real-time interaction, these results clearly demonstrated that visualizing 3D and 4D digital medical data is feasible with a properly constructed software framework.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Identification of Time-Varying Pilot Control Behavior in Multi-Axis Control Tasks

Recent developments in fly-by-wire control architectures for rotorcraft have introduced new interest in the identification of time-varying pilot control behavior in multi-axis control tasks. In this paper a maximum likelihood estimation method is used to estimate the parameters of a pilot model with time-dependent sigmoid functions to characterize time-varying human control behavior. An experiment was performed by 9 general aviation pilots who had to perform a simultaneous roll and pitch control task with time-varying aircraft dynamics. In 8 different conditions, the axis containing the time-varying dynamics and the growth factor of the dynamics were varied, allowing for an analysis of the performance of the estimation method when estimating time-dependent parameter functions. In addition, a detailed analysis of pilots adaptation to the time-varying aircraft dynamics in both the roll and pitch axes could be performed. Pilot control behavior in both axes was significantly affected by the time-varying aircraft dynamics in roll and pitch, and by the growth factor. The main effect was found in the axis that contained the time-varying dynamics. However, pilot control behavior also changed over time in the axis not containing the time-varying aircraft dynamics. This indicates that some cross coupling exists in the perception and control processes between the roll and pitch axes.

Zaal, Peter M. T.↗

Time-resolved electron energy distribution functions at the substrate during a HiPIMS discharge with cathode voltage reversal

Abstract The time-dependent plasma properties of a high-power impulse magnetron sputtering plasma are investigated which include a positive ‘kick’ pulse on the sputtering target 2 μ s after the main negative pulse, this reversing the voltage on the cathode. At a substrate 15 cm distant from the magnetron, the time-dependent electron energy distribution function (EEDF), plasma potential, potential commute time and plasma diffusion properties are measured using a single Langmuir probe. Results show that the positive pulse on the target expels plasma and raises the plasma potential across the chamber on the order of 1 to 2 μ s, which is the time scale of the electron diffusion. The EEDF at the substrate fits a Druyvesteyn distribution during the main negative pulse rising slightly in average energy over time. The distribution is still Druyvesteyn and at the very start of the positive pulse, but then loses the higher energy electrons and drops in average electron energy as the positive pulse progresses. A Boltzmann equation solver, BOLSIG+, was used to predict the EEDF at the substrate during the positive pulse and it agrees best with the measurements assuming a value of 0.2 Td for the E / N (electric field/gas number density).

Physics↗