Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Systems Performance Lab”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

De-Risking High-Recovery Brackish Water Desalination via Flow Reversal and Feed Flushing Using Techno-Economic Assessment

Novel desalination technologies have demonstrated enhanced performance and improved financial metrics over existing processes adopted by industry. Establishing quantitative performance targets is essential for achieving financial benefits over the current state of the art. Herein, we demonstrate how WaterTAP, a techno-economic assessment (TEA) tool, can be used to identify minimum performance metrics necessary to achieve financial benefit over using existing processes. This study evaluates the feasibility of increasing water recovery at the Chino Desalter I above 90 % through the addition of a third variable configuration reverse osmosis (VCRO) stage. Sensitivity analyses revealed flow reversal frequency, feed flushing volume (used as a cleaning step), and membrane lifespan are key factors influencing the financial viability of the VCRO process. The TEA analysis demonstrated that the system must achieve a recovery of 84 % and a 1-year membrane lifespan to have a breakeven LCOW, while achieving 90 % recovery can ultimately reduce the LCOW by 16 %. Notably, a trade-off between decreasing frictional losses and increased osmotic pressure across the recovery range, resulted in a stable specific energy consumption across the recovery range, enabling meaningful LCOW reductions without an energy penalty, a key finding that contrasts with conventional RO. This work demonstrates how TEA can guide system design by identifying key performance targets and exploring trade-offs, enabling data-driven decisions to de-risk innovative processes. These findings underscore the importance of leveraging TEA to evaluate scaling mitigation strategies and optimize inland desalination systems for sustainable and cost-effective operation.

14 SOLAR ENERGY↗

Custom Accessors: Enabling Scalable Data Ingestion, (Re-)Organization, and Analysis on Distributed Systems

The emerging class of high velocity and high volume data analytic workflows comprise interwoven data ingestion, organization, and processing stages, with ingestion and organization steps often contributing comparable or even higher computational costs than actual processing steps. Since complex workflows consist of a variety of phases that view and use data differently, being able to construct efficient, scalable, distributed data structures (arrays, vectors, sets, maps, and multi-maps) is essential and requires custom methods to extend and shrink containers, analyze and position data, and, maintain globallyconsistent meta-data. In this paper, we propose a novel datastructure access paradigm based on the concept of Accessors. At a high level, accessors are customizable callable objects that can modify the behavior of insert, read, update, and delete operations for distributed containers while preserving atomicity guarantees. Accessors provide a very clean and natural way to implement a variety of programming patterns, e.g., conditional insertion/deletion and cascading computations, which would be otherwise hard (or even impossible) to express in parallel and distributed settings without using locks. We demonstrate the practicality and usefulness of our approach with two representative use cases and study the performance of these applications on a distributed High-Performance Computing system. Our analysis highlights that our proposed abstraction allows for an effective overlapping and concurrent execution of different workflow steps (e.g., data ingestion and analysis), which in a conventional analytics pipeline would execute sequentially, contributing cumulatively to the overall latency.

Castellana, Vito G. [BATTELLE (PACIFIC NW LAB)] (O↗

Maskman

SAND2025-04369O Maskman is a user-friendly tool designed to create hex masks, which are essential for optimizing application performance in high-performance computing environments. By converting a list of integers into binary and then hex masks, Maskman simplifies the process of setting application affinity. This ensures that software runs efficiently on specific nodes within a computing cluster. Ideal for researchers and developers, Maskman streamlines the preparation of inputs for HPC schedulers, enhancing resource management and improving overall system performance. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Pase, Douglas [Sandia National Lab. (SNL-CA), Live↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air-Source Heat Pumps

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climate conditions. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in northwest United States and one in Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five-seconds, to calculate heat pump's capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides valuable insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving the overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Light monitoring system for the lead tungstate calorimeter in Hall D at Jefferson Lab

A new electromagnetic calorimeter composed of 1596 lead tungstate (PbWO 4 ) scintillating crystals has been constructed for the GlueX detector in Hall D at Jefferson Lab. The calorimeter is equipped with a light monitoring system that uses light-emitting diodes. The light monitoring system was fabricated, installed, and integrated into the GlueX trigger system. It was successfully operated during detector commissioning and data collection, providing monitoring of the detector response and verification of the calibration with a precision better than 1%. In conclusion, the paper describes the design, installation, and performance of the light monitoring system.

Lead tungstate calorimeter↗

Assessment of the Electrical Substation-Grid Testbed with Inside/Outside Devices and Distributed Ledger Technology

The electrical substation-grid testbed was created to integrate the GOOSE and/or DNP (Distributed Network Protocol) messages with time synchronized sources and Distributed Ledger Technology (DLT). The objective was to study the impact of faults and cyber-events at an electrical substation with inside (protective relays) and outside (power meters) substation devices. The electrical substation-grid testbed was based on the design of a 34.5/ 12.47 kV electrical substation (sectionalized bus configuration) with two power transformers, connected to radial power lines and load feeders. The electrical substation-grid testbed was installed at 252 lab space (Advanced Power System Protection), Grid Research Integration and Deployment Center (GRID-C), Oak Ridge National Laboratory. This testbed was created for Task 5, DarkNet project. The electrical substation-grid testbed was created to simulate fault and/or cyber events that could potentially result in damage to the electrical infrastructure. In addition, tests were run that are usually not allowed to be performed in an operational electrical power grid, because these test scenarios could trip breakers and/or generate fault situations that could potentially damage equipment. The number of tests performed in the electrical substation-grid testbed were executed in a better way than in a real electrical substation and/or power grid, because multiple tests could be run in a short period of time, and complex permits, and safety/ schedule restrictions like in a real electrical substation environment were not needed. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that are used by electrical utilities, to have same conditions that we could observe in a real power grid or electrical substation. The electrical substation-grid testbed was based on using a real time simulator and expansion box with amplifiers that were wired to electrical substation-grid devices. This hardware-in-the-loop (HIL) was provided by protective relays, power meters, ethernet switches, remote terminal units, synchronized timing network clock, DLT devices, workstations, and servers. This report includes the design, installation, and assessment of the electrical substation-grid testbed that was similar to an operational electrical substation, integrating the power system protection, communication, and control systems. The results for the electrical substation-grid testbed were based on:• verifying the analog signals for protective relays and power meters, • observing the synchronized time source frame at devices, • authenticating the GOOSE (IEC 61850) and DNP messages from power meters and protective relays, and • verifying the trip conditions of protective relays at fault tests with the power system fault event detection, using DLT devices. For future work, the electrical substation-grid testbed with protective relays and power meters, using DLT and synchronized time source from DarkNet, will be used to study the impact of cyber-events at inside and outside substation devices. Advanced algorithms for detecting cyber-events produced by non-desired protective relay settings will be studied, to improve the detection and reliability of protection, control, and communication systems at power grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Laboratory Evaluation of Tunable White LEDs for Circadian Lighting in Commercial Offices

Tunable white Light-Emitting Diode (LED) systems that allow users to control Correlated Color Temperature (CCT) are often marketed for circadian health, which is an emerging priority in commercial office lighting. However, the energy impacts of meeting circadian criteria with standard non-tunable LEDs and with tunable white LEDs are not well understood. The goals of this project were to implement select commercial lighting systems, including tunable white LEDs, to meet visual and circadian criteria in an office environment, and to quantify lighting performance and energy usage. Most recent studies on tunable white LEDs, circadian lighting strategies, and energy impacts have relied on computer simulations and models. While little research has directly measured tunable LED energy usage for circadian criteria, EPRI has recently published results from a lab-based evaluation of illuminance, spectral output, and energy consumption for several LED products marketed for circadian performance. The research presented here contributes to the field by quantifying the performance of market-available technologies through detailed monitoring of performance parameters (such as illuminance, spectral output, glare, and energy consumption) in a physical space (an office environment).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

HIGH POWER TEST OF A 3.9 GHZ 5-CELL DEFLECTING-MODE CAVITY IN A CRYOGENIC OPERATION

A 3.9 GHz deflecting mode (S, TM110) cavity has been long used for six-dimensional phase-space beam manipulation tests [1-5] at the A0 Photo-Injector Lab (16 MeV) in Fermilab and their extended applications with vacuum cryomodules are currently planned at the Advanced Superconducting Test Accelerator (ASTA) user facility (> 50 MeV). Despite the successful test results, the cavity, however, demonstrated limited RF performance during liquid nitrogen (LN2) ambient operation that was inferior to theoretical prediction. We have been performing full analysis of the designed cavity by analytic calculation and comprehensive system simulation analysis to solve complex thermodynamics and mechanical stresses. The re-assembled cryomodule is currently under the test with a 50 kW klystron at the Fermilab A0 beamline, which will benchmark the modeling analysis. The test result will be used to design vacuum cryomodules for the 3.9 GHz deflecting mode cavity that will be employed at the ASTA facility for beam diagnostics and phase-space control.

HEP↗

High Temperature Steam Electrolysis Process Performance and Cost Estimates - DOE Hydrogen Program AMR Presentation

Technology readiness levels (TRLs) of electrolysis systems have dramatically increased in recent years as the interest in clean hydrogen production and decarbonization of transportation, industrial and other sectors increases across the globe. This is especially true of high temperature steam electrolysis (HTSE) / solid oxide electrolysis cell (SOEC) systems which show promise of much higher system efficiencies than other more developed electrolysis technologies. This possibility of higher efficiencies of HTSE / SOEC systems has been previously assumed to be theoretically possible but in recent years it has become less theoretical and more realistic as an increasing amount of suppliers complete lab and pilot tests showing very promising results. Research in the areas of manufacturing techniques, material selection, electrode and electrolyte compositions, and balance of plant size and integration continues at a fast pace as an increasing number of suppliers both internationally and domestically become involved. The advantages of HTSE become more pronounced when HTSE is coupled with nuclear power plants (NPPs). This is because thermal energy produced by the nuclear reactor can be used in a series of heat transfer loops and heat exchangers to vaporize HTSE feedwater, which drastically improves the economics of the process. Idaho National Laboratory (INL) has been very involved in the research and modeling of HTSE systems for a number of years, in collaboration with other national laboratories, academia, and industry stakeholders both on the hydrogen production as well as the hydrogen demand side. The modeling completed over the years on a large variety of projects has led to a wealth of knowledge at INL including in the area of the technoeconomic assessment (TEA) of HTSE systems. TEAs include process modeling of the HTSE systems to calculate system energy requirements and equipment sizing, followed by estimation of capital and operating costs to enable calculation of the levelized cost of hydrogen (LCOH). The TEA work performed has produced incremental improvements and tuning of the methods, assumptions, models, and results of the analyses as well as providing some opportunities for validating these results. The purpose of this document is to record the current baseline HTSE analyses led by INL to show the current status of assumptions and costs of these systems. Given the rapid development of this technology, the variety of suppliers entering the space, and the increasing attention government and industry are giving to such systems, this document may be updated on a periodic basis with updated analysis and assumptions. This document compiles various analyses results and approaches completed over a period of years into a single document to be used as a baseline going forward. It represents what the INL HTSE analysis group assumes to be the internal best estimate of the current operation, costs, and landscape of the HTSE industry state of the art capability for current SOEC technology in an Nth-of-a-Kind (NOAK) plant, which in this study is defined as existence of the manufacturing capacity to support previous deployment of N = 100 count of 25 MWe modular HTSE blocks (with modular equipment component cost reductions specified as following a 95% learning curve). That said, this is a public document and as such so no proprietary data was used or included in this report. There may be HTSE suppliers that have performance specifications, and cost estimates, and test data that differ from the analysis presented in this document. This document is meant to be a best conservative estimate of the technology and not an absolute reference.

08 HYDROGEN↗

Commissioning Results of the ESR2 Compressors at JLab

Abstract The future operation of the 4 kW 15 Kelvin MOLLER experiment at Jefferson lab necessitates an increase of cryogenic capacity at the End Station Refrigerator. The current plant is the former 1.5 kW (4.5 K) ESCAR plant that has been operating at Jefferson Lab since 1995. The existing 1.5 kW plant is not able to support the load for MOLLER and will be replaced with a refurbished plant comprised of the cold box and compressors of the 4 kW ASST-A plant from the Superconducting Super Collider in Texas. This paper reports the commissioning results of the warm compressor system. We compare the compressors’ current and past performance, specifically examining their Isothermal and Volumetric efficiency. The results indicate that the refurbished equipment’s efficiency is comparable to its original performance, proving that the reuse and refurbishment of old systems is a worthwhile endeavor.

Perry, C. [Thomas Jefferson National Accelerator F↗

Software Defined Cyberinfrastructure

Within and across thousands of science labs, researchers and students struggle to manage data produced in experiments, simulations, and analyses. Largely manual research data lifecycle management processes mean that much time is wasted, research results are often irreproducible, and data sharing and reuse remain rare. In response, we propose a new approach to data lifecycle management in which researchers are empowered to define the actions to be performed at individual storage systems when data are created or modified: actions such as analysis, transformation, copying, and publication. We term this approach software-defined cyberinfrastructure because users can implement powerful data management policies by deploying rules to local storage systems, much as software-defined networking allows users to configure networks by deploying rules to switches.We argue that this approach can enable a new class of responsive distributed storage infrastructure that will accelerate research innovation by allowing any researcher to associate data workflows with data sources, whether local or remote, for such purposes as data ingest, characterization, indexing, and sharing. We report on early experiments with this approach in the context of experimental science, in which a simple if-trigger-then-action (IFTA) notation is used to define rules.

Foster, Ian↗

ornladios/ADIOS2

ADIOS 2: The Adaptable Input Output (I/O) System version 2 is an open-source framework that addresses scientific data management challenges, e.g. scalable parallel I/O, as we approach the exascale era in high-performance computing (HPC). ADIOS 2 bindings are available in C++, C, Fortran, Python and can be used on supercomputers, personal computers, and cloud systems running on Linux, macOS and Windows. ADIOS 2 has out-of-the-box support for MPI and serial environments.

ECP↗

Optimizing Viral Detection: Creating Fluorescent Chikungunya Virus Infectious Clones

Human infection with Chikungunya virus (CHIKV) results in debilitating joint pain and arthritis that can persist for months or even years. CHIKV is a re-emerging virus responsible for large epidemics in Asia, Africa, Europe, and most recently South and Central America. Yet, CHIKV has no specific treatment or vaccine. Therefore, steps towards eradicating the virus are important to public safety. Tools to facilitate drug screens are especially important when searching for viable treatments. Therefore, our lab sought to create reporter CHIKV encoding fluorescent markers, to detect infection in cells. Cloning was used to develop a CHIKV infectious clone encoding GFP. Creation of this tool required use of PCR, Gibson assembly, and the CRISPR Cas9 system. We are also working to create a CHIKV expressing mCherry. Next steps include determining the efficiency of these infectious clones compared to wildtype virus and performing drug screen studies. I also made contributions to other projects including development of a CRISPR Cas9 guide RNA library, a bioinformatics project using new software, and CRISPR Cas9 expressing cell line, that will be used in Zika virus studies. Finally, I assisted in development of a market survey focused on biodefense technologies for DHS.

59 BASIC BIOLOGICAL SCIENCES↗

Particle-based high-temperature thermochemical energy storage reactors

Solar and other renewable energy driven gas-solid thermochemical energy storage (TCES) technology is a promising solution for the next generation energy storage systems due to its high operating temperature, efficient energy conversion, ultra-long storage duration, and potential high energy density. Experimental and theoretical studies suggest that the respective gravimetric and volumetric TCES energy storage densities vary from 200 to 3000 kJ kg –1 and 1–3 GJ m –3 . Solar radiation or heat generated from electric furnaces powered by renewable electricity can be stored in the form of chemical energy through endothermic reactions, while the stored chemical energy can be converted to thermal energy via an exothermic reaction when needed. The design of highly effective reactors requires a deep understanding of materials, thermodynamics, chemical kinetics, and transport phenomena. At time of writing, TCES reactors are yet to be deployed at commercially relevant scales, leaving a substantial gap between development efforts and commercial feasibility. Therefore, this review aims to examine the state-of-the-art design and performance of particle-based TCES reactors with different reactive materials. Fundamentals related to TCES reactive materials, reaction conditions, thermodynamics and kinetics, and transport phenomena are reviewed in detail to provide a comprehensive understanding of the reactor design and operation. Five major types of TCES reactors have been comprehensively reviewed and compared, including fixed, moving, rotary, fluidized, and entrained bed reactors. Most reported prototype reactors in the literature operate at lab scale with thermal inputs below 40 kW, and scaled TCES reactors (e.g., at megawatt level) are yet to be demonstrated. The nominal reactor operating temperatures range from 300 to 1500 °C, depending on the selected chemistry, reactive material, and heat sources. To evaluate their designs, the reactors are assessed in aspects of performance, cost, and durability. Discrepancies in performance indicators of energy storage density, extent of reaction, and various energy efficiencies are highlighted. The scale-up of reactors and power block integration, which hold the key to the successful commercialization of TCES systems, are critically analyzed. Furthermore, advanced materials (both reactive materials and ceramic reactor housing materials), effective particle flow control, advanced modeling tools, and novel system design may bring significant improvement to the energy efficiency, storage density and cost competitiveness of particle-based TCES reactors.

25 ENERGY STORAGE↗

Status of the SABRE South experiment at the Stawell underground physics laboratory

The SABRE (Sodium iodide with Active Background REjection) experiments aim to detect an annual rate modulation from dark matter interactions in ultra-high purity NaI(Tl) crystals. The SABRE South experiment is located at the Stawell Underground Physics Laboratory (SUPL), Australia, and is the first deep underground laboratory in the Southern Hemisphere. SABRE South is designed to disentangle seasonal or site-related effects from the dark matter-like modulated signal first observed by DAMA/LIBRA in the Northern Hemisphere using an active veto and muon detection system. It is a partner to the SABRE North effort at the Laboratori Nazionali del Gran Sasso (LNGS). SABRE South is instrumented with ultra-high purity NaI(Tl) crystals immersed in a linear alkyl benzene (LAB) based liquid scintillator veto, further surrounded by passive steel and polyethylene shielding and a plastic scintillator muon veto. Significant work has been undertaken to understand the experimental backgrounds and performance of the crystals. The SABRE South experiment is under construction, and will be commissioned from late 2022 to early 2023. We will present the final design of SABRE South, the status of its construction, its expected background, and its sensitivity to a DAMA/LIBRA like modulation. We will also present recent quenching factor measurements of sodium nuclear recoils in NaI(Tl) crystals measured at the Heavy Ion Accelerator Facility, and a report on the status of SUPL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Draft Impacts: Modeling and Lab Validation (CRADA Final Report)

Chimney draft is a significant source of variability in real-world wood heater performance, yet laboratory tests conducted for certification do not capture this variability. Because draft varies with climate, chimney height, and home conditions, a heater that performs well in the lab can perform quite differently when installed in a home. Until now, wood heater manufacturers and installers have lacked the tools needed to anticipate how draft will vary across real installations or to advise on corrective measures when draft is too low or too high. The goal of this project was to develop and validate an open-source draft prediction tool for cordwood heater chimney systems. Over 18 months, Lawrence Berkeley National Laboratory (LBNL) and the Hearth, Patio & Barbecue Association (HPBA) collaborated to build a physics-based, Python tool that predicts how chimney draft evolves during operation, from ignition through steady burning. HPBA convened a stakeholder group of manufacturers and venting experts who provided feedback throughout development. LBNL validated the tool against laboratory measurements from a catalytic and a non-catalytic cordwood heater operated across a range of chimney heights and room-pressure conditions.

42 ENGINEERING↗

Ushering in the New Age of Laboratories: Smart Labs in Practice; Preprint

Ventilation is the first line of defense against airborne hazards produced during research activities in laboratories. A vital component to maintaining healthy, safe, indoor air quality, laboratory ventilation systems are often victim to ineffective operation, posing a risk to an organization's most important asset - the researchers. Furthermore, system inefficiencies can lead to up to 50% wasted energy. By providing a framework to improve the safety and energy efficiency through optimized ventilation and operations, the Smart Labs Toolkit guides laboratory stakeholders through a straight-forward, holistic approach to achieving a dynamic Smart Labs program. A Smart Labs program employs a combination of physical, administrative, and management techniques to plan, assess, optimize, and manage high-performance laboratories. Grounded in the Smart Labs methodology, the National Renewable Energy Laboratory (NREL) implemented a successful Smart Labs program to oversee the design, construction, maintenance, and operations of its laboratories. To accomplish this effort, NREL's key stakeholders created an internal partnership to align NREL's existing laboratories with Smart Labs principles and solidify organizational roles for the safe and efficient operation of laboratory assets. The program provides the groundwork for decarbonization strategies centered around building operation. This paper outlines best practices employed by NREL to develop a cross-cutting Smart Labs team, garner managerial support, and effectively communicate of goals around safety and energy. Strategies include specific Smart Labs best practices, such as implementing a Laboratory Ventilation Risk Assessment - a systematic process for identifying risk due to airborne hazards and informing dynamic, demand-based ventilation to optimize safety and efficiency.

decarbonization↗

High Energy Yield Distributed Architecture for Large Commercial and Utility-Scale PV Systems

Photovoltaic energy has come a long way from its early days when small cells were fabricated in the labs in the early 50s. While it took a long time for PV modules to mature into what we now see in the market and in rooftops across the world, the power electronics has been lagging behind & was always the weakest point in the PV plant, being responsible for the majority of failures & robbing the PV plants of their full potential by losing precious Watts in the process of converting power from DC to AC. Since the early days of PV power, it has been recognized that the modules need to operate at their maximum power point in order to extract as much power as is available from the PV modules at a given time of day and year. Numerous maximum power point devices were developed to do just this. While effective at extracting as much power as they can, soon after there was a realization that in a PV installation where a central inverter is used, many losses occur, hence energy yield losses. This has led to thinking about alternative architectures where the maximum power point tracking (MPPT) is performed much closer to the modules rather than at a central inverter. Several architectures were proposed ranging from a microinverter, microconverter, string inverter, string optimizer, and to a multi-string inverter or optimizer. While these architectures promise to increase the energy yield by 5% to 25% (depending where MPPT is located), & recovering losses due to shading, soiling, mismatch … there were no real studies and implementations in the field to corroborate these numbers. The program that GE Global Research proposed & received funding for is aimed at a type of distributed architectures, namely the dc architectures where only the MPPT function is distributed across the PV plant. Further, the project is concerned with choosing the right architecture for large scale commercial & utility scale plants but not residential installations. Findings from Task 1- Define Requirements & Develop Architecture- showed that for large scale commercial & utility PV plants, locating the MPPT at the string level with a string size of >3kW is the most cost effective solution & that the increase in energy yield of 6% to 8% is more than enough to make up for the increased cost due to additional power electronics. Our study also shows that in addition to an increase in energy yield, having a dc/dc converter at the string level brings additional benefits such as increased array visibility, allowing for increased monitoring and diagnostics; high and constant dc bus voltage which allows for reducing losses further and optimizing the inverter; and ability to detect ground and arc faults. Task 2 focused on designing a suitable dc/dc converter that meets the requirements defined in Task 1: Efficiency, Cost, & Reliability. For this task, we surveyed and simulated all candidate topologies known by the practitioners in the field. We also generated a novel topology, simulated it, & compared it to existing topologies. Our novel topology being a partial power processing converter came out on top due to its simplicity (fewer parts), it high efficiency, its reliability, and its lower cost. In the remaining tasks of the project, we built the hardware, tested it first in the lab, then in the field and once we worked out all the bugs and issues and were confident our system was robust, we installed it on the rooftop and started collecting the data by mid-Q3 2012. We shared our work with the scientific community in the form of conference & Journal papers, hence contributing to the general understanding of this technology area. The methods, techniques, and hardware developed under this project have all been tested in the field over long periods of time, and under many conditions and have been shown to be robust and reliable. The converters built and developed under this program have been in operation in the field since mid-June 2012, and no hardware failures have been recorded. While some software issues have been seen, none have been showstoppers. The cost analysis of the hardware showed that it meets the cost target set in the requirement document developed in the trade-off study. Improving the performance of solar installations for commercial and utility scale plants contributes to reducing their cost of ownership, hence spreading them to a larger section of the society and making them affordable. Our project contributed to the understanding of the distributed architectures, showed that PV plants’ cost of electricity can be reduced through additional power electronics which allows for harvesting more energy from the plant. When the project started in 2009, the cost of PV energy was still high, hence there was a real need to increase the energy yield, hence reduce the levelized cost of electricity (LCOE). While costs have come down significantly, the need for increasing the energy yield is still relevant, hence the project results, hardware, and techniques developed are still pertinent today. By taking this project from concept to rooftop demonstration, we showed that the technology is mature enough, robust enough, and has the potential to be used by many more customers, hence benefiting the public in general through the spread of PV energy, which ultimately contributes to reducing our dependency on fossil fuel, improving the environment, and creating more jobs.

14 SOLAR ENERGY↗