Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Synchrotrons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Nonthermal synchrotron radiation and pair annihilation in gamma-ray bursts

A self-consistent Monte Carlo simulation of quantized synchrotron emission, pair production, and pair annihilation in strong (2 x 10 to the 12th G or greater) magnetic fields is presented as a model of the production of annihilation lines in gamma-ray burst sources. The calculation determines the self-consistent photon spectrum and pair distribution functions resulting from a nonthermal injection of electrons into a region of homogeneous, strong magnetic field. The results indicate that the appearance of observable annihilation features in gamma-ray burst spectra requires isotropic or fan-beamed injection of electrons with energies of at least 5 MeV. The lines are narrow because higher energy electrons escape annihilation and do not contribute to Doppler-broadening. Injection beamed along the field did not produce observable annihilation lines in any of the cases studied. As a result, emission at energies much greater than 1 MeV produced through beaming seems to be incompatible with observable annihilation in this model. These results are discussed in relation to observed features in gamma-ray burst spectra.

Preece, Robert↗

Time-dependent shock acceleration of energetic electrons including synchrotron losses

The present investigation of the time-dependent particle acceleration problem in strong shocks, including synchrotron radiation losses, solves the transport equation analytically by means of Laplace transforms. The particle distribution thus obtained is then transformed numerically into real space for the cases of continuous and impulsive injections of particles at the shock. While in the continuous case the steady-state spectrum undergoes evolution, impulsive injection is noted to yield such unpredicted features as a pile-up of high-energy particles or a steep power-law with time-dependent spectral index. The time-dependent calculations reveal varying spectral shapes and more complex features for the higher energies which may be useful in the interpretation of outburst spectra.

Fritz, Klaus-Dieter↗

Crystal regularity with high-resolution synchrotron X-radiation diffraction imaging

New, high-resolution sources of X-radiation such as monochromatic synchrotron radiation beams with subarcsec divergence allow observation of regularities in a range of crystals with sufficient clarity for comprehensive analyses, whose results can deepen understanding of the nature of various crystal irregularities, their sources, and their effects on device performance. An account is presented of the results thus achievable with irregularities encountered in lattice orientation and strain, grain and subgrain boundaries, dislocations, domain boundaries, additional phases, and surface scratches. Significant achievements to date encompass the observation of critical anomalies in lead tin telluride, the reconciliation of disparate observations of GaAs, the determination of the performance effects of irregularities in mercuric iodide, and the characterization of the origins of crystal growth in bismuth silicon oxide.

Steiner, Bruce↗

Radio images of Jupiter's synchrotron radiation at 6, 20, and 90 cm

VLA observations of Jupiter's nonthermal radiation at wavelengths of 6, 20, and 90 cm are presented and compared. The spatial resolution in all images is 0.25 R(J) (R/J/ = Jovian radius). The brightness distribution of Jupiter is very similar at each of the three wavelengths, although the radiation peaks at 6 cm are at a slightly larger distance from Jupiter than those at the longer wavelengths. This is due to the higher rate of synchrotron radiation losses at the shorter wavelengths. Radial profiles through the images clearly show the presence of a 'shoulder' or flattening in the intensity at about 2.5 R(J) due to absorption effects by the satellite Amalthea. In addition, the so-called 'hot region' in Jupiter's radiation belts is clearly present at all three wavelengths: images of the planet at a cml (central meridian longitude) of about 30-40 deg show the radiation peak to the right of Jupiter to be much brighter than the peak at the left, while images at a cml of about 210-220 deg show the opposite. The difference in brightness between the two radiation peaks is similar at all three wavelengths.

De Pater, Imke↗

Relativistic magnetosonic shock waves in synchrotron sources - Shock structure and nonthermal acceleration of positrons

The theoretical properties of relativistic, transverse, magnetosonic collisionless shock waves in electron-positron-heavy ion plasmas of relevance to astrophysical sources of synchrotron radiation are investigated. Both 1D electromagnetic particle-in-cell simulations and quasi-linear theory are used to examine the spatial and kinetic structure of these nonlinear flows. A new process of shock acceleration of nonthermal positrons, in which the gyrating reflected heavy ions dissipate their energy in the form of collectively emitted, left-handed magnetosonic waves which are resonantly absorbed by the positrons immediately behind the ion reflection region, is described. Applications of the results to the termination shocks of pulsar winds and to the termination shocks of jets emanating from the AGN are outlined.

Hoshino, Masahiro↗

Synchrotron emission from a cosmological jet as a model of gamma-ray bursts

The nonthermal rapidly varying spectra of gamma-ray bursts require relativistic beaming if the source is at a cosmological distance. Limits on the Lorentz factors and magnetic fields of extragalactic jet models of gamma-ray bursts are derived from the synchrotron source function, the position of the fundamental cyclotron resonance, the Thomson optical depth of radiating electrons, and the Thomson optical depth of electron-positron pairs created in photon-photon collisions of Compton upscattered radiation. The last of these constraints is the strongest, and it is satisfied by the observations if the jet's Lorentz factor is greater than 100. The limit from the position of the cyclotron fundamental requires a magnetic field strength below approximately 10 exp 10 G. Jet models producing observable cyclotron lines are allowed. The acceleration region in the burst must be separate from the emission region. The similarity of gamma-ray burst jet models to models of quasars and BL Lac objects suggest that if gamma-ray bursts are cosmological sources, they are a type of active galaxy.

Brainerd, J. J.↗

Synchrotron infrared spectroscopy at megabar pressures - Vibrational dynamics of hydrogen to 180 GPa

New techniques for measuring infrared spectra at megabar pressures using synchrotron radiation have been developed and applied to study the Q1(1), Qi(1) + Si(0), and QR(J) vibrational transitions of solid hydrogen to 180 GPa. The frequency difference between the Q1(1) infrared and Raman vibrons increases from 3/cm (zero pressure) to 510/cm (180 GPa), indicating a dramatic increase in intermolecular coupling with pressure. A negative frequency shift is observed for the infrared vibron above 140 GPa. A significant increase in frequency and LO-TO splitting of the lattice phonon is also documented.

Hanfland, M.↗

Petrogenesis of the Zagami meteorite - Inferences from synchrotron X-ray (SXRF) microprobe and electron microprobe analyses of pyroxenes

Major and minor element abundances in pyroxene, principally pigeonite, from Zagami meteorite samples were determined by electron microprobe; abundances of trace elements Ni, Cu, Zn, and Ga were obtained by synchrotron X-ray (SXRF) microprobe. Abundances of Ni and Cr in the magnesian zones and cores are partially decoupled from abundances of other compatible (Mg) and incompatible (Fe,Ti) elements. The textures, chemical zoning, and element decouplings in the pigeonites are consistent with igneous crystal growth at moderate cooling rates, not isothermally or near equilibrium. From element partitioning and mass balance, Zagami is estimated to contain 20 +/- 5 percent or less cumulus pyroxene (half augite and half pigeonite), half the proportion suggested by equilibrium distribution of Fe/Mg between pigeonite and melt. This inconsistency may be resolved if all pigeonite/melt element partitioning was affected by the rapid growth of the pigeonites. The inference that the pyroxene zoning patterns reflect only magmatic events is consistent with an igneous age of 180 m.y. for Zagami.

Treiman, A. H.↗

Long-term changes in Jovian synchrotron radio emission - Intrinsic variations or effects of viewing geometry?

Possible causes of the observed long-term variation of Jovian synchrotron radio emission, including both intrinsic changes in the Jovian radiation belts and apparent changes due to variations in the Jovigraphic declination of the earth, D sub E, are investigated. An increase in diffusion rate with other parameters held constant results in an inward displacement of the peak emission radial distance that is not observed. Effects of viewing geometry changes are examined. The possible importance of such effects is suggested by a correlation between the total decimetric radio flux and D sub E, which varies between -3.3 and +3.3 deg during one Jovian orbital period. Because the Jovian central meridian longitudes where the magnetic latitude passes through zero during a given Jovian rotation change substantially with D sub E and since significant longitudinal asymmetries exist in both the volume emissivity and the latitudinal profile of the beam, the total intensity should be at least a partial function of D sub E.

Hood, Lon L.↗

Residual strain gradient determination in metal matrix composites by synchrotron X-ray energy dispersive diffraction

An X-ray technique for the measurement of internal residual strain gradients near the continuous reinforcements of metal matrix composites has been investigated. The technique utilizes high intensity white X-ray radiation from a synchrotron radiation source to obtain energy spectra from small (0.001 cu mm) volumes deep within composite samples. The viability of the technique was tested using a model system with 800 micron Al203 fibers and a commercial purity titanium matrix. Good agreement was observed between the measured residual radial and hoop strain gradients and those estimated from a simple elastic concentric cylinders model. The technique was then used to assess the strains near (SCS-6) silicon carbide fibers in a Ti-14Al-21Nb matrix after consolidation processing. Reasonable agreement between measured and calculated strains was seen provided the probe volume was located 50 microns or more from the fiber/matrix interface.

Kuntz, Todd A.↗

Reflectance calibrations of AXAF mirror samples at absorption edges using synchrotron radiation

We are developing a system to calibrate reflectances of witness coupons to the AXAF flight mirrors at the National Synchrotron Light Source over the 0.05-12 keV energy range. These witness coupons will be coated in the same process as the AXAF mirror elements. One of the key issues is the accurate determination of mirror efficiencies across the absorption edges of the mirror coating elements. We present a series of reflectance measurements with 2 eV resolution of a nickel-coated flat mirror in the region of the Ni L-II (870 eV) and L-III (853 eV) absorption edges. Scans of reflectance versus grazing angle at fixed energies in this region show distinct interference fringes at grazing angles larger than the critical angle which are extinguished as the photon energy is increased beyond the low point of the L-III edge, indicating total absorption of the evanescent wave within the Ni film. At 51 arc minutes grazing angle, measured reflectance decreases smoothly by 35 percent and then recovers in an 8 eV band at the L-III edge. We have also measured reflectances in the M absorption edge region for gold, platinum, and iridium coated mirrors. We derive optical parameters n and k specific to the film for comparison to the existing data tables.

Graessle, D. E.↗

Optical constants from mirror reflectivities measured at synchrotrons

Improved mirror reflectivity measurement techniques have been introduced to permit more accurate determinations of optical constants delta and beta in the complex index of refraction n = 1 - delta - i(beta) over the energy range 50 to 5000 eV. When the density has been determined by X-ray or other means, one can calculate the real and imaginary parts, f-prime and f-double prime, of the complex atomic scattering factor f = f(o) + f-prime + if-double prime from delta and beta. Preliminary results are given for the Ni LIII edge around 852 eV, and the Au M edge region from 2150 to 3500 eV. Since these are the first experimental evaluations of delta for these element edges, they are compared with appropriate reservations to semiempirical tabulations. There is much potential for this technique applied to synchrotron sources.

Blake, R. L.↗

Feasibility study of the use of synchrotron radiation in the calibration of AXAF - Initial reflectivity results

The 1-percent calibration accuracy goal of the Advanced X-ray Astrophysics Facility is being approached by way of an experiment at the National Synchrotron Light Source that will demonstrate the accuracy achievable in reflectance measurements conducted on coated flat mirrors in the 50 eV-12 keV energy range. The coatings will be of commercially produced Au, Ni, and Ir, deposited either by sputtering or by e-beam deposition. Optical constants will be estimated via the reflectance vs. angle-of-incidence method.

Graessle, D. E.↗

Performance Report: A timeline for the synchrotron calibration of AXAF

Presented herein are the known elements of the timeline for synchrotron reflectance calibrations of HRMA witness samples (Section 2). In Section 3, lists of measurements to be done on each witness flat are developed. The elements are then arranged into timelines for the three beamlines we expect to employ in covering the full 50-12,000 eV energy range (Section 4). Although the required AXAF operational range is only 0.1-10 keV, we must calibrate the extent to which radiation just outside this band may contaminate our in-band response. In Section 5, we describe the working relationships which exist with each of the beamlines, and estimate the time available for AXAF measurements on each. From the timelines and the available time, we calculate the number of flats which could be measured in full detail over the duration of the program for each beamline. A suggestion is made regarding a minimum required baselines of witness flats from each element coating run or qualification run to be used in the calibration. We intend that this suggestion open discussion of the issue of witness flat deployment.

Tananbaum, H. D.↗

The effect of comet Shoemaker-Levy 9 on Jupiter's synchrotron radiation

Solid material from comet Shoemaker-Levy 9 is expected to modify Jupiter's decimetric radio emission. Electrons passing through dust grains suffer a degradation in their energy, while larger sized material absorbs all electrons impinging on it. If there is enough dust and/or larger sized material in the magnetosphere, the effect on the energetic electrons can be observed via their synchrotron radiation, emitted at microwave frequencies. The planet's radio emission is expected to decrease, and the presence of dust induces a hardening in the radio spectrum. We expect the intensity to decrease immediately after cometary material enters the radiation belts; the radio emission continues to drop for many months as electrons diffuse inwards through a dusty magnetosphere. Radio observations of the planet during and after the cometary impact thus yield information on the amount of cometary material (optical depth of the dust and macroscopic material), impacts between cometary material and Jupiter's ring, and the diffusion process of energetic electrons through the magnetosphere.

De Pater, Imke↗

Characterization of Cadmium-Zinc Telluride Crystals Grown by 'Contactless' PVT Using Synchrotron White Beam Topography

Crystals of Cd(1-x)Zn(x)Te grown by Physical Vapor Transport (PVT) using self-seeding 'contactless' techniques were characterized using synchrotron radiation (reflection, transmission, and Laue back-reflection X-ray topography). Crystals of low (x = 0.04) and high (up to x approx. = 0.4) ZnTe content were investigated. Twins and defects such as dislocations, precipitates, and slip bands were identified. Extensive inhomogeneous strains present in some samples were found to be generated by interaction (sticking) with the pedestal and by composition gradients in the crystals. Large (up to about 5 mm) oval strain fields were observed around some Te precipitates. Low angle grain boundaries were found only in higher ZnTe content (x greater than or equal to 0.2) samples.

Palosz, W.↗

The Synchrotron Shock Model Confronts a "Line of Death" in the BATSE Gamma-Ray Burst Data

The synchrotron shock model (SSM) for gamma-ray burst emission makes a testable prediction: that the observed low-energy power-law photon number spectral index cannot exceed -2/3 (where the photon model is defined with a positive index: $dN/dE \propto E{alpha}$). We have collected time-resolved spectral fit parameters for over 100 bright bursts observed by the Burst And Transient Source Experiment on board the {\it Compton Gamma Ray Observatory}. Using this database, we find 23 bursts in which the spectral index limit of the SSM is violated, We discuss elements of the analysis methodology that affect the robustness of this result, as well as some of the escape hatches left for the SSM by theory.

Preece, Robert D.↗

High Resolution X-Ray Diffraction of Macromolecules with Synchrotron Radiation

We recently combined synchrotron-based monochromatic X-ray diffraction topography methods with triple axis diffractometry and rocking curve measurements: high resolution X-ray diffraction imaging techniques, to better understand the quality of protein crystals. We discuss these methods in the light of results obtained on crystals grown under different conditions. These non destructive techniques are powerful tools in the characterization of the protein crystals and ultimately will allow to improve, develop, and understand protein crystal growth. High resolution X-ray diffraction imaging methods will be discussed in detail in light of recent results obtained on Hen Egg White Lysozyme crystals and other proteins.

Stojanoff, Vivian↗