Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Strip”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Strip antenna figure errors due to support truss member length imperfections

The dependence of strip antenna steadyy state geometric errors on member length uncertainties in the supporting truss beam is studied with the Monte carlo analysis of a representative truss design. The results, presented in a format streamlined for practical use, can guide the specification for hardware fabrication of required error tolerances (for structural properties as well as member lengths), or they can aid the prediction of antenna performance if component statistics are available.

truss↗

The First Observation of Intra Beam Stripping of Negative Hydrogen in a Superconducting Linear Accelerator

We report on an experiment in which a negative hydrogen ions beam in the Spallation Neutron Source (SNS) linear accelerator was replaced with a beam of protons with similar size and dynamics. Beam loss in the superconducting part of the SNS accelerator was at least an order of magnitude lower for the proton beam. Also beam loss has a stronger dependence on intensity with H- than with proton beams. These measurements verify a recent theoretical explanation of unexpected beam losses in the SNS superconducting linear accelerator based on an intra beam stripping mechanism for negative hydrogen ions. An identification of the new physics mechanism for beam loss is important for the design of new high current linear ion accelerators and the performance improvement of existing machines

08 HYDROGEN↗

Results of Laboratory Testing of Advanced Power Strips: Preprint

This paper describes the results of a laboratory investigation to evaluate the technical performance of advanced power strip (APS) devices when subjected to a range of home entertainment center and home office usage scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technical Specification for Advanced Power Strips Version 1.0

This specification provides detailed selection criteria for five major advanced power strips (APSs), and sets standards for modeling APSs. It is intended to help those who procure APSs select the most effective models for their commercial buildings.

Advanced power strips, APS, plug and process loads↗

Low Carbon Technology Strategies: Stand-Alone Retail and Strip Mall

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon retail buildings within their existing building portfolios. Stand-alone retail and strip malls often use packaged rooftop units for heating, cooling, and ventilation.

analytics↗

Increasing the Pressure‐Free Stripping Capacity of the Lithium Metal Anode in Solid‐State‐Batteries by Carbon Nanotubes

Abstract Lithium metal is the key anode material for solid‐state‐batteries as its successful implementation will drastically increase their energy and power densities. However, anode contact loss during stripping leads to dendrites upon plating and subsequent cell failure. Design strategies to mitigate these issues are crucial to enable the use of lithium metal anodes. This paper reports the dissolution kinetics of composite anodes made of lithium metal and carbon nanotubes (CNTs) with a garnet‐type solid electrolyte (SE). In addition to an enhancement of the effective diffusion within the anode, its dissolution is fundamentally changed from being 2D to 3D. By maintaining contact with the SE, the CNTs facilitate lithium transport to the interface, which yields more than 20 mAh cm −2 discharge capacity at 100 µ A cm −2 without the application of external stack pressure ( > 1 MPa). Conclusions drawn from electrochemical data on the anode microstructure are validated using cryo‐focused‐ion‐beam scanning electron microscopy and correlated with the mechanical properties. Micro‐indentation, acoustic analysis, and stress–strain testing show that mechanical properties of the anode, like yield strength and hardness, are adjustable. Overall, it is shown that the mechanical and electrochemical properties of Li–CNT composite electrodes can be tailored to suit the requirements of a practical cell.

Fuchs, Till↗

Preparation of Surface Organometallic Catalysts by Gas-Phase Ligand Stripping and Reactive Landing of Mass-Selected Ions

Organometallic complexes immobilized on surfaces combine the high selectivity of homogeneous catalysts with the ease of separation of catalyst from products of heterogeneous materials. Here we report a novel approach for the highly controlled preparation of surface organometallic catalysts by gas-phase ligand stripping combined with reactive landing of mass-selected ions onto self assembled monolayer surfaces. Collision induced dissociation is used to generate highly reactive undercoordinated metal complexes in the gas-phase for subsequent surface immobilization. Complexes with an open coordination shell around the metal center are demonstrated to show enhanced activity towards reactive landing in comparison to fully ligated species. In situ TOF-SIMS analysis indicates that the immobilized complexes exhibit behaviour consistent with catalytic activity when exposed to gaseous reagents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterizing hole trap production due to proton irradiation in germanium cross-strip detectors

We present an investigation into the effects of high-energy proton damage on charge trapping in germanium cross-strip detectors with the goal of accomplishing three important measurements. First, we calibrated and characterized the spectral resolution of a spare COSI-balloon detector in order to determine the effects of intrinsic trapping, finding that electron trapping due to impurities dominates over hole trapping in the undamaged detector. Second, we performed two rounds of proton irradiation of the detector in order to quantify, for the first time, the rate at which charge traps are produced by proton irradiation. We find that the product of the hole trap density and cross-sectional area, [nσ] h , follows a linear relationship with the proton fluence, F p , with a slope of (5.4 ± 0.4) x 10 -11 cm/p + . Third, by utilizing our measurements of physical trapping parameters, we performed calibrations which corrected for the effects of trapping and mitigated degradation to the spectral resolution of the detector.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling of the Flows of Admixtures in a Random Layered Strip with Probable Arrangement of Inclusions Near the Boundaries of the Body

We study the random flow of admixtures in a two-phase stochastically inhomogeneous strip with the most probable arrangement of inclusions in the vicinity of the surfaces of the body. A mathematical model is formulated for the function of diffusion flow with nonzero constant initial concentration. A random diffusion flow is represented in the form of a Neumann series. The procedure of averaging of the random mass flow over the ensemble of phase configurations with arcsine distribution function is performed. The influence of the characteristics of the medium on the distribution of mass flow is analyzed. It is shown that if the diffusion coefficient of admixtures in the inclusion is higher than for the matrix, then the increase in the characteristic thickness of the layers causes a decrease in the value of the diffusion flow, whereas the mass flow in the entire body increases with the volume fraction of the inclusions.

97 MATHEMATICS AND COMPUTING↗

Biomarker Mapping on Skin Tape Strips Using MALDI Mass Spectrometry Imaging

Keratinocyte organization and biochemistry are important in forming the skin’s protective barrier. Intrinsic and extrinsic factors can affect skin barrier function at the cellular and molecular levels. Matrix-assisted laser desorption/ionization (MALDI) mass spectrometric imaging, a technique which combines both molecular aspects and histological details, has proven to be a valuable method in various disciplines including pharmacology, dermatology and cosmetology. It typically requires ex vivo samples, prepared following frozen tissue sectioning. This paper demonstrates the feasibility of performing MALDI analysis on tape strips collected non-invasively on skin. The aim is to obtain molecular imaging of corneocytes on tapes towards novel biological insights. Tapes were collected from two skin sites (volar forearm and cheek) of human volunteers. Ten molecules relating to skin barrier function were detected with a single mode of acquisition at high spatial resolution with a 7 T MALDI-Fourier transform ion cyclotron resonance (FTICR) instrument. The method sensitivity was adequate to create molecular maps which could be overlaid on transmission microscopy images of the same area of the tape. Analysis of the molecular distributions from tapes at the two skin sites was consistent with the known skin properties of the two sites, confirming the validity of the observations. Hierarchical clustering analysis was used to differentiate corneocyte populations based on their molecular profiles. Furthermore, morphological analysis provided a new way of considering statistical populations of corneocytes on the same tape, rather than measuring a single averaged value, providing additional useful information relating to their structure-function relationship. .

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electron capture, ionization and excitation cross sections for keV collisions between fully stripped ions and atomic hydrogen in ground and excited states

Using a semiclassical close-coupling approach, we have calculated electron capture, excitation and ionization cross sections for collisions of fully stripped hydrogen, helium and lithium ions with atomic hydrogen in the ground state and in all excited states up to n=3. The cross sections for collision energies between 1 and 100 keV/u are given in table form. Furthermore, we provide estimates of the accuracy of the cross sections. The set of data presented in this work represent the first complete and consistent quantum study of these collision systems and will find use in the modeling and diagnosis of thermonuclear fusion plasma reactors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Separation of thorium, uranium, and rare earths from a strip solution generated from coarse coal refuse

This work systematically evaluated the separation performance of thorium, uranium, and rare earths when coal and coal byproduct were utilized as a non-traditional feedstock for rare earth production. A synthetic solution was prepared following the elemental composition of a strip solution generated from coarse coal refuse and used throughout the study. Various separation techniques including selective precipitation, solvent extraction, and a modified experimental protocol incorporating the two were applied to extract rare earths while minimizing the non-selective recovery of thorium and uranium into the product stream. Test results indicate that selective precipitation was effective for the removal of thorium at a pH value approaching 5 while solvent extraction preferentially removed uranium from rare earths. Therefore, a modified experimental protocol consisting of both selective precipitation and solvent extraction was subsequently developed and implemented. The findings following the modified experimental protocol indicate that extractant concentration, solvent extraction feed pH, and organic to aqueous (O/A) ratio all played a significant role in the removal of uranium. Among all the tests conducted, the best separation performance was achieved using a one-stage precipitation at a pH value of 4.8, 50 v% TBP, solvent extraction feed pH of 3.5, and an O/A ratio of 3, which corresponded to an overall rare earth, thorium, and uranium recovery of 79.6%, 0%, and 3.1%, respectively.

01 COAL, LIGNITE, AND PEAT↗

Pilot testing of a heat integrated 0.7 MWe CO 2 capture system with two-stage air-stripping: Amine degradation and metal accumulation

An advanced 0.7 MWe small pilot coal-fired post-combustion CO 2 capture system with heat integration combined with two-stage stripping was tested here on a slipstream of flue gas by the University of Kentucky Center for Applied Energy Research (UKy-CAER). Evaluation of solvent degradation products was performed to determine the impact of oxygen exposure due to incorporation of the secondary air stripper into the conventional amine absorber/stripper system. The overall degradation rates and products observed during the testing campaign were comparable to previously published reports using 30% monoethanolamine (MEA) as the baseline/commissioning solvent. The rates of heat stable salt accumulation and amine degradation were similar to those from conventional CO 2 capture systems using MEA. Metal accumulation as the result of material corrosion inside the system from an improperly constructed material was observed. Finally, the impact of the secondary air stripper appears negligible relative to other published MEA campaigns tested at similar flue gas conditions and system operating hours.

03 NATURAL GAS↗

Pilot testing of a heat integrated 0.7 MWe CO 2 capture system with two-stage air-stripping: Emission

The University of Kentucky Center for Applied Energy Research (UKy-CAER) designed, constructed and tested an advanced 0.7 MWe post-combustion CO 2 capture system on a coal-fired power plant using a heat integration process combined with two-stage stripping to enhance the CO 2 absorber performance and lower the cost of CO 2 capture. Evaluation of emissions from the solvent and degradation products was performed to determine the impact on the amine solvent of coal combustion flue gas contaminants and oxygen exposure due to incorporation of the secondary air stripper into the conventional amine absorber/stripper system. The overall amine, ammonia and aldehyde emission levels observed during the baseline 30% monoethanolamine (MEA) solvent testing campaign were generally comparable to previously published reports tested at similar flue gas conditions and system operating hours. Ammonia emissions were correlated to high levels of iron and copper in the solvent, likely as a result of material corrosion.

20 FOSSIL-FUELED POWER PLANTS↗