Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Space Conditioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Large Scale Transcriptional Analysis of Legacy Spaceflight Tissues From the Nasa Biological Institutional Science Collection

The NASA Biological Institutional Science Collection (NBISC) has amassed a collection of valuable space biology samples spanning from early Space Shuttle missions to recent missions on the International Space Station (ISS). However, the full potential of this archive has not been realized, with many samples having been stored for decades without being re-accessed. Given the pace of analytical advancement since NBISC began accumulating samples, we initiated a pilot study to reveal additional patterns that may have been missed during the original investigations and provide technical robustness and scientific value for a cost-effective sequencing approach. We selected 84 mouse and rat samples spanning four separate Space Shuttle, ISS and ground-analogue studies with a focus on muscle, spleen and thymus tissues to allow identification of important changes related to musculoskeletal unloading and immune function. High quality RNA from these tissues was extracted and used to generate transcriptional profiling data using a cost-effective Tag-seq approach and immediately released it on GeneLab. The released datasets included gastrocnemius tissues from rats during the 1991 Space Shuttle mission (GLDS-422) and a ground analogue study in 2019 (GLDS-418), and mice from the 2014 ISS mission (GLDS-419). Also released were two thymus datasets, one from rats flown on the 1993 Space Shuttle (GLDS-423) and another from mice flown on the 2017 ISS (GLDS-421) missions, along with one mouse spleen dataset from a 2017 ISS mission (GLDS-420). These data will serve as a pilot of a much larger and comprehensive study which would generate similar data from thousands of NBISC samples, enabling the discovery and validation of molecular networks influenced by space conditions.

Lovorka Degoricija↗

Development of a Roof Savings Calculator

A web-based Roof Savings Calculator (RSC) has been deployed for the Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. This tool employs the latest web technologies and usability design to provide an easy input interface to an annual simulation of hour-by-hour, whole-building performance using the world-class simulation tools DOE-2.1E and AtticSim. Building defaults were assigned and can provide annual energy and cost savings after the user selects nothing more than building location. In addition to cool reflective roofs, the RSC tool can simulate multiple roof types at arbitrary inclinations. There are options for above sheathing ventilation, radiant barriers and low-emittance surfaces. The tool also accommodates HVAC ducts either in the conditioned space or in the attic with custom air leakage rates. Multiple layers of thermal mass, ceiling insulation and other parameters can be compared side-by-side to generate energy/cost savings between two buildings. The RSC tool was benchmarked against field data for demonstration homes in Ft Irwin, CA.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Roof Savings Calculator

A web-based Roof Savings Calculator (RSC) has been deployed for the Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. This tool employs the latest web technologies and usability design to provide an easy input interface to an annual simulation of hour-by-hour, whole-building performance using the world-class simulation tools DOE-2.1E and AtticSim. Building defaults were assigned and can provide estimated annual energy and cost savings after the user selects nothing more than building location. In addition to cool reflective roofs, the RSC tool can simulate multiple roof types at arbitrary inclinations. There are options for above sheathing ventilation, radiant barriers, and low-emittance surfaces. The tool also accommodates HVAC ducts either in the conditioned space or in the attic with custom air leakage rates. Multiple layers of building materials, ceiling and deck insulation, and other parameters can be compared side-by-side to generate an energy/cost savings estimate between two buildings. The RSC tool was benchmarked against field data for demonstration homes in Ft. Irwin, CA.

DOE cool roof calculator↗

An Experimental Evaluation of HVAC-Grade Carbon-Dioxide Sensors: Part 3, Humidity, Temperature, and Pressure Sensitivity Test Results

This is the third paper in a four-part series reporting on the test and evaluation of typical carbon-dioxide sensors used in building HVAC applications. Fifteen models of NDIR HVAC-grade CO2 sensors were tested and evaluated to determine the humidity, temperature, and pressure sensitivity of the sensors. This paper reports the performance of the sensors at various relative humidity, temperature, and pressure levels common to building HVAC applications and provides a comparison with manufacturer specifications. Among the 15 models tested, eight models have a single-lamp, single-wavelength configuration, four models have a dual-lamp, single-wavelength configuration, and three models have a single-lamp, dual-wavelength configuration. The sensors were tested in a chamber specifically fabricated for this research. A description of the apparatus and the method of test are described in Part 1 (Shrestha and Maxwell 2009). The test result showed a wide variation in humidity, temperature, and pressure sensitivity of CO2 sensors among manufacturers. In some cases, significant variations in sensor performance exist between sensors of the same model. Even the natural variation in relative humidity could significantly vary readings of some CO2 sensor readings. The effects of temperature and pressure variation on NDIR CO2 sensors are unavoidable without an algorithm to compensate for the changes. For the range of temperature and pressure variation in an air-conditioned space, the effect of pressure variation is more significant compared to the effect of temperature variation.

54 ENVIRONMENTAL SCIENCES↗

Multiple-Zone Variable Refrigerant Flow System Modeling and Equipment Performance Mapping

We developed a variable refrigerant flow (VRF) vapor compression system model, which has five indoor units, one outdoor unit and one water heater. The VRF system can run simultaneous space conditioning (cooling or heating) and water heating. The indoor units and outdoor unit use fin-&-tube coil heat exchangers, and the water heater uses a tube-in-tube heat exchanger. The fin-&-tube coil heat exchangers are modeled using a segment-by-segment approach and the tube-in-tube water heater is modeled using a phase-by-phase approach. The compressor used is a variable-speed rotary design. We calibrated our model against a manufacturer s product literature. Based on the vapor compression system model, we investigated the methodology for generating VRF equipment performance maps, which can be used for energy simulations in TRNSYS and EnergyPlus, etc. In the study, the major independent variables for mapping are identified and the deviations between the simplified performance map and the actual equipment system simulation are quantified.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of Indoor Air Quality Benefits and Energy Costs of Mechanical Ventilation

Intake of chemical air pollutants in residences represents an important and substantial health hazard. Sealing homes to reduce air infiltration can save space conditioning energy, but can also increase indoor pollutant concentrations. Mechanical ventilation ensures a minimum amount of outdoor airflow that helps reduce concentrations of indoor emitted pollutants while requiring some energy for fan(s) and thermal conditioning of the added airflow. This work demonstrates a physics based, data driven modeling framework for comparing the costs and benefits of whole-house mechanical ventilation and applied the framework to new California homes. The results indicate that, on a population basis, the health benefits from reduced exposure to indoor pollutants in New California homes are worth the energy costs of adding mechanical ventilation as specified by ASHRAE Standard 62.2.This study determines the health burden for a subset of pollutants in indoor air and the costs and benefits of ASHRAE's mechanical ventilation standard (62.2) for new California homes. Results indicate that, on a population basis, the health benefits of new home mechanical ventilation justify the energy costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Study and Energy-Plus Benchmarks for Energy Saver Homes having Different Envelope Designs

An alliance to maximize energy efficiency and cost-effective residential construction (ZEBRAlliance) built and field tested four homes that are 50 percent more energy efficient than a code compliant home. The homes are unoccupied for the duration of a two-year field study, thereby eliminating the confounding issue of occupancy habits. All homes have about the same consistent and scheduled internal load. Each home showcases a unique envelope strategy: 1) structural insulated panel (SIP), 2) optimal value wall framing (OVF), 3) advanced framing featuring the benefits of insulations mixed with phase change materials (PCM), and 4) an exterior insulation and finish system (EIFS). All homes have different weather resistive barriers (WRBs) and/or air barriers to limit air and moisture infiltration. Three homes provide space conditioning and water heating via a ground loop heat exchanger, while the fourth home uses a high efficiency air-to-air heat pump and heat pump water heater. Field performance and results of EnergyPlus V7.0 benchmarks were made for roof and attics as compared to cathedral design and for wall heat flows to validate models. The moisture content of the wall sheathing is shown to prove the protecting effectiveness of WRBs. Temperature distributions through insulations in the wall and ceiling with and without PCMs are described to characterize the performance of the PCM building envelopes.

Attic↗

Development of a Residential Ground-Source Integrated Heat Pump

A residential-size ground-source integrated heat pump (GSIHP) system has been developed and is currently being field tested. The system is a nominal 2-ton (7 kW) cooling capacity, variable-speed unit, which is multi-functional, e.g. space cooling, space heating, dedicated water heating, and simultaneous space cooling and water heating. High-efficiency brushless permanent-magnet (BPM) motors are used for the compressor, indoor blower, and pumps to obtain the highest component performance and system control flexibility. Laboratory test data were used to calibrate a vapor-compression simulation model (HPDM) for each of the four primary modes of operation. The model was used to optimize the internal control options and to simulate the selected internal control strategies, such as controlling to a constant air supply temperature in the space heating mode and a fixed water temperature rise in water heating modes. Equipment performance maps were generated for each operation mode as functions of all independent variables for use in TRNSYS annual energy simulations. These were performed for the GSIHP installed in a well-insulated 2600 ft2(242 m2) house and connected to a vertical ground loop heat exchanger(GLHE). We selected a 13 SEER (3.8 CSPF )/7.7 HSPF (2.3 HSPF, W/W) ASHP unit with 0.90 Energy Factor (EF) resistance water heater as the baseline for energy savings comparisons. The annual energy simulations were conducted over five US climate zones. In addition, appropriate ground loop sizes were determined for each location to meet 10-year minimum and maximum design entering water temperatures (EWTs) to the equipment. The prototype GSIHP system was predicted to use 52 to 59% less energy than the baseline system while meeting total annual space conditioning and water heating loads.

Energy Efficiency↗

Regional Variation in Residential Heat Pump Water Heater Performance in the U.S.: Preprint

Residential heat pump water heaters (HPWHs) have recently reemerged on the U.S. market. These units have the potential to provide homeowners significant cost and energy savings. However, actual in use performance of a HPWH will vary significantly with climate, installation location, HVAC equipment, and hot water use. To determine what actual in use energy consumption of a HPWH may be in different regions of the U.S., annual simulations of both 50 and 80 gallon HPWHs as well as a standard electric water heater were performed for over 900 locations across the U.S. The simulations included a benchmark home to take into account interactions between the space conditioning equipment and the HPWH and a realistic hot water draw profile. It was found that the HPWH will always save some source energy when compared to a standard electric resistance water heater, although savings varies widely with location. In addition to looking at source energy savings, the breakeven cost (the net installed cost a HPWH would have to have to be a cost neutral replacement for a standard water heater) was also examined. The highest breakeven costs were seen in cases with high energy savings, such as the southeastern U.S., or high energy costs, such as New England and California. While the breakeven cost is higher for 80 gallon units than 50 gallon units, the higher net installed costs of an 80 gallon unit lead to the 50 gallon HPWHs being more likely to be cost effective.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measured water heating performance of a vertical-bore water-to-water ground source heat pump (WW-GSHP) for domestic water heating over twelve months under simulated occupancy loads

This paper presents monthly performance metrics of a 5.275 kW (1.5 ton) WW-GSHP providing 227 L day-1 domestic hot water at 49 C. Daily water use is simulated as stipulated in the Building America Research Benchmark Definition capturing the living habits of the average U.S household. The 94.5m vertical-bore ground loop is shared with a separate GSHP for space conditioning the 251m2 residential home. Data on entering water temperatures, energy extracted from the ground, delivered energy, compressor electricity use, COP, WW-GSHP run times, and the impact of fan and pump energy consumption on efficiency are presented for each month. Factors influencing performance metrics are highlighted.

ground source↗

New Whole-House Solutions Case Study: Quadrant Homes

Quadrant moved ducts and high efficiency furnace inside conditioned space on nearly all 300 customizable house plans. The builder uses dry, true factory-assembled walls, extensive air sealing, and just in time delivery for pre-sold homes.

air sealing↗

New Whole-House Solutions Case Study: Schneider Homes, Inc.

Schneider Homes cut energy use by 50% over the 2004 IECC on 28 homes built near Seattle in 2008. Schneider packed the walls with R-23 of blown fiberglass and blanketed the ceiling with R-38 of blown cellulose. Ducts went into conditioned space through open-web floor trusses between floors and air handlers went into an air sealed garage closet.

blown cellulose↗