Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scanning Electron Microscopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Research and test facilities for development of technologies and experiments with commercial applications

One of NASA'S agency-wide goals is the commercial development of space. To further this goal NASA is implementing a policy whereby U.S. firms are encouraged to utilize NASA facilities to develop and test concepts having commercial potential. Goddard, in keeping with this policy, will make the facilities and capabilities described in this document available to private entities at a reduced cost and on a noninterference basis with internal NASA programs. Some of these facilities include: (1) the Vibration Test Facility; (2) the Battery Test Facility; (3) the Large Area Pulsed Solar Simulator Facility; (4) the High Voltage Testing Facility; (5) the Magnetic Field Component Test Facility; (6) the Spacecraft Magnetic Test Facility; (7) the High Capacity Centrifuge Facility; (8) the Acoustic Test Facility; (9) the Electromagnetic Interference Test Facility; (10) the Space Simulation Test Facility; (11) the Static/Dynamic Balance Facility; (12) the High Speed Centrifuge Facility; (13) the Optical Thin Film Deposition Facility; (14) the Gold Plating Facility; (15) the Paint Formulation and Application Laboratory; (16) the Propulsion Research Laboratory; (17) the Wallops Range Facility; (18) the Optical Instrument Assembly and Test Facility; (19) the Massively Parallel Processor Facility; (20) the X-Ray Diffraction and Scanning Auger Microscopy/Spectroscopy Laboratory; (21) the Parts Analysis Laboratory; (22) the Radiation Test Facility; (23) the Ainsworth Vacuum Balance Facility; (24) the Metallography Laboratory; (25) the Scanning Electron Microscope Laboratory; (26) the Organic Analysis Laboratory; (27) the Outgassing Test Facility; and (28) the Fatigue, Fracture Mechanics and Mechanical Testing Laboratory.

Source record↗

Electron beam analysis of particulate cometary material

Electron microscopy will be useful for characterization of inorganic dust grains in returned comet nucleus samples. The choice of instrument(s) will depend primarily on the nature of the samples, but ultimately a variety of electron-beam methods could be employed. Scanning and analytical (transmission) electron microscopy are the logical choise for morphological, mineralogical, and bulk chemical analyses of dust grains removed from ices. It may also be possible to examine unmelted ice/dust mixtures using an environmental scanning electron microscope equipped with a cryo-transfer unit and a cold stage. Electron microscopic observations of comet nuclei might include: (1) porosities of dust grains; (2) morphologies and microstructures of individual mineral grains; (3) relative abundances of olivine, pyroxene, and glass; and (4) the presence of phases that might have resulted from aqueous alteration (layer silicates, carbonates, sulfates).

Bradley, John↗

TiCl4 as a source of TiO2 particles for laser anemometry measurements in hot gas

A method of reacting TiCl4 with water saturated gaseous nitrogen (GN2) at the entrance into a high temperature gas flow is described. The TiO2 particles formed are then entrained in the gas flow and used as seed particles for making laser anemometry (LA) measurements of the flow velocity distribution in the hot gas. Scanning electron microscope photographs of the TiO2 particles are shown. Data rate of the LA processor was measured to determine the amount of TiO2 formed. The TiCl4 and mixing gas flow diagram is shown. This work was performed in an open jet burner.

Weikle, Donald H.↗

Pultrusion Process Development for Long Space Boom Model

Long flexible-boom models were required to develop ground-vibration test methods for very-low-frequency space structures with applications to the proposed Space Station. Pultruded quasi-isotropic composite beams were selected as an option over extruded aluminum alloy structures because of the lower cost potential, the higher specific strength, the flexural properties, and the dynamic similarity considerations. The reinforcement material that was used was biaxial (0 deg/90 deg) fiberglass roving held in place with knitted polyester yarn such that equal fiber volume in 0 deg and 90 deg orientations provided nearly equal strength in both longitudinal and transverse directions. An isophthalic polyester resin system was used as the matrix. Continuous lengths up to 270 ft were easily pultruded with biaxial fabric. Tracking problems were encountered with similar unidirectional fabrics. Analyses of processing problems were conducted to determine causes for delamination, scaling, and sloughing. Ultrasonic C-scanning and scanning electron microscope examinations were conducted as well as mechanical testing to failure. Test results indicate that pultrusion processes can be used to produce quasi-isotropic composite structures.

Wilson, Maywood L.↗

Fatigue crack growth in a unidirectional SCS-6/Ti-15-3 composite

An investigation was conducted to characterize and model the fatigue crack growth (FCG) behavior of a SCS-6/Ti-15-3 metal matrix composite. Part of the study was conducted using a fatigue loading stage mounted inside a scanning electron microscope (SEM). This unique facility allowed high magnification viewing of the composite fatigue processes and measurement of the near crack tip displacements. The unidirectional composite was tested in the (0)8 (i.e., longitudinal) and (90)8 (i.e., transverse) orientations. For comparison purposes unreinforced matrix material produced by the identical process as the reinforced material was also tested. The results of the study reveal that the fatigue crack growth behavior of the composite is a function of specimen geometry, fiber orientation and the interaction of local stress fields with the highly anisotropic composite. In the case of (0)8 oriented single edge notch (SEN) specimens and (90)8 oriented compact tension (CT) specimens, the crack growth was normal to the loading direction. However, for the (0)8 CT specimens the crack grew mostly parallel to the loading and the fiber direction. The unusual fatigue behavior of the (0)8 CT specimens was attributed to the specimen geometry and the associated high tensile bending stresses perpendicular to the fiber direction. These stresses resulted in preferential cracking in the weak interface region perpendicular to the fiber direction. The interface region, and in particular the carbon coating surrounding the fiber proved to be the composites weakest link. In the (0)8 SEN the crack growth was confined to the matrix leaving behind unbroken fibers which bridged the cracked surfaces. As the crack grew longer, more fibers bridged the crack resulting in a progressive decrease in the crack growth rates and eventual crack arrest. The actual near crack tip displacement measurements were used in a proposed formulation for a bridging-corrected effective crack driving force, delta K(sub eff). This parameter was able to account for most of the experienced bridging and correlated the (0)8 SEN fatigue crack growth data reasonably well.

Kantzos, Peter↗

Experiment K-6-01. Distribution and biochemistry of mineral and matrix in the femurs of rats

Previous analyses of the composition of mineral and matrix in the bone of young rats following space flight has revealed deficits in calcium, phosphorus, and osteocalcin, a non-collagenous protein, without an associated decrease in collagen. To characterize the location and nature of this mineralization defect in a weight bearing long bone, the femur, researchers attempted to relate the spatial distribution of mineral in situ in the proximal, central and distal thirds of the femoral diaphysis to the biochemical composition of bone from the same area. Biochemical analyses revealed lower concentrations of calcium, phosphorus and osteocalcin but not collagen only in the central third of the diaphysis of the flight animals (F) compared to synchronous controls (S). Collagen concentration was reduced only in the proximal third of the diaphysis, where all 3 crosslinks, expressed as nM/mol collagen were higher in F than S. A new technique, x ray microtomography, with a resolution of 26 microns, was used to obtain semi-quantitative data on mineral distribution in reconstructed sections of wet whole bone. To improve the resolution of the mineral density distribution, images of the surfaces of cut sections were analyzed by backscattered electrons in a scanning electron microscope (BSE). There was good agreement between the results of the two stereochemical techniques which revealed distinct patterns of mineralization in transverse and longitudinal directions of the diaphysis. The novel methodology developed for this flight experiment shows considerable promise in elucidating the biochemical nature of what appear to be regional alterations in the mineralization of long bones of animals exposed to spaceflight.

Arnaud, S.↗

Low-resistance noble metal contacts to high-temperature superconductors

Low-resistance contacts were made to both YBa2Cu3O(7-x) and Bi2BaSr2Cu2O8, and to related superconducting compounds by melting gold or silver pads onto the samples before the final oxygen treatment. Scanning electron microscope studies show that both gold and silver do not diffuse far from the contact area. The surface contact resistivity of the best contacts made by the melting technique has an upper limit value in the 10 to the -8th ohm sq cm range at 77 K. This contact resistivity shows no significant change in its value over a period of 17 months. Furthermore, an electron radiation dose of 5.7 x 10 to the 17th electron/sq cm only doubled the contact resistivity.

Selim, R.↗

Collectors Of Airborne And Spaceborne Particles

Brushlike collectors capture samples of dust and other particles in space vacuum or air for optical, scanning-electron-microscope, and/or x-ray analysis. Gently decelerates particles without damaging them, minimizing tendency of some particles to rebound. Depending on design of specific collector of this type, it captures particles ranging upward in size from fractions of micrometer to few micrometers.

Frazer, Robert E.↗

Development of mercuric iodide uncooled x ray detectors and spectrometers

The results obtained in the development of miniature, lowpower, light weight mercuric iodide, HgI2, x ray spectrometers for future space missions are summarized. It was demonstrated that HgI2 detectors can be employed in a high resolution x ray spectrometer, operating in a scanning electron microscope. Also, the development of HgI2 x ray detectors to augment alpha backscattering spectrometers is discussed. These combination instruments allow for the identification of all chemical elements, with the possible exception of hydrogen, and their respective concentrations. Additionally, further investigations of questions regarding radiation damage effects in the HgI2 x ray detectors are reported.

Iwanczyk, Jan S.↗

Matrix fatigue crack development in a notched continuous fiber SCS-6/Ti-15-3 composite

In this study the extensive matrix fatigue cracking that has been observed in notched SCS-6/Ti-15-3 composites is investigated. Away from the notch a uniform spacing of the fatigue cracks develops. Closer to the notch, fiber-matrix debonding which occurs increases the crack spacing. Crack spacing and debond length determined from shear-lag cylinder models compare favorably with experimental observations. Scanning electron microscope (SEM) fractography showed that the principal fatigue crack initiation occurred around the zero degree fibers. Interface failure in the 90 degree plies does not lead to the development of the primary fatigue cracking.

Hillberry, B. M.↗

SIMS analysis of extended impact features on LDEF experiment

Discussed here are the first Secondary Ion Mass Spectroscopy (SIMS) analysis of projectile material deposited in extended impact features on Ge wafers from the trailing edge. Although most capture cells lost their plastic film covers, they contain extended impact features that apparently were produced by high velocity impacts when the plastic foils were still intact. Detailed optical scanning of all bare capture cells from the trailing edge revealed more than 100 impacts. Fifty-eight were selected by scanning electron microscope (SEM) inspection as prime candidates for SIMS analysis. Preliminary SIMS measurements were made on 15 impacts. More than half showed substantial enhancements of Mg, Al, Si, Ca, and Fe in the impact region, indicating micrometeorites as the projectiles.

Amari, S.↗

Chemical analysis of metal and polymer surfaces on the front and rear LDEF

The University of Alabama in Huntsville experiment AO114 contained 128 solid surface samples, half of which were exposed on the front and half on the rear of the Long Duration Exposure Facility (LDEF). Each sample is being subject to a battery of analysis methods. In poster form, details of the x-ray photoelectron spectra, Auger electron spectra, Fourier Transform Infrared and ATR infrared spectra, high resolution profilometry, and scanning electron microscope imagery will be presented from a selection of metal and non-metal surfaces.

Christi, L.↗

Results of examination of silvered Teflon from the Long Duration Exposure Facility

Pieces of silvered Teflon thermal control blanket from seventeen locations on the Long Duration Exposure Facility (LDEF) were studied. Results of the measurements of surface texturing, and mechanical, electrical and thermal properties are presented. Photos of the blankets, scanning electron microscope pictures, infrared spectra, and surface analysis results are presented. Contamination issues relative to performance of the blankets are discussed. The variation in measured properties are reported as a function of exposure conditions.

Rousslang, Ken W.↗

Volatile-bearing phases in carbonaceous chondrites: Compositions, modal abundance, and reaction kinetics

The spectral and density characteristics of Phobos and Deimos (the two small natural satellites of Mars) strongly suggest that a significant fraction of the near-earth asteroids are made of carbonaceous chondrites, which are rich in volatile components and, thus, could serve as potential resources for propellants and life supporting systems in future planetary missions. However, in order to develop energy efficient engineering designs for the extraction of volatiles, knowledge of the nature and modal abundance of the minerals in which the volatiles are structurally bound and appropriate kinetic data on the rates of the devolatilization reactions is required. Theoretical calculations to predict the modal abundances and compositions of the major volatile-bearing and other mineral phases that could develop in the bulk compositions of C1 and C2 classes (the most volatile rich classes among the carbonaceous chondrites) were performed as functions of pressure and temperature. The rates of dehydration of talc at 585, 600, 637, and 670 C at P(total) = 1 bar were determine for the reaction: Talc = 3 enstatite + quartz + water. A scanning electron microscopic study was conducted to see if the relative abundance of phases can be determined on the basis of the spectral identification and x ray mapping. The results of this study and the other studies within the project are discussed.

Ganguly, Jibamitra↗

Moessbauer spectroscopy and scanning electron microscopy of the Murchison meteorite

Meteorites provide a wealth of information about the solar system's formation, since they have similar building blocks as the Earth's crust but have been virtually unaltered since their formation. Some stony meteorites contain minerals and silicate inclusions, called chondrules, in the matrix. Utilizing Moessbauer spectroscopy, we identified minerals in the Murchison meteorite, a carbonaceous chondritic meteorite, by the gamma ray resonance lines observed. Absorption patterns of the spectra were found due to the minerals olivine and phyllosilicate. We used a scanning electron microscope to describe the structure of the chondrules in the Murchison meteorite. The chondrules were found to be deformed due to weathering of the meteorite. Diameters varied in size from 0.2 to 0.5 mm. Further enhancement of the microscopic imagery using a digital image processor was used to describe the physical characteristics of the inclusions.

Brown, Christopher L.↗

Effect of grinding conditions on the fatigue life of titanium 5Al-2.5Sn alloy

An investigation into the effect of grinding conditions on the fatigue life of titanium 5Al-2.5Sn is presented. Damage to surface integrity and changes in the residual stresses distribution are studied to assess changes in fatigue life. A surface grinding machine, operating at speeds ranging from 2000 to 6000 fpm and using SiC wheels of grit sizes 60 and 120, was used to grind flat subsize specimens of 0.1-in. thickness. After grinding, the specimens were fatigued at a chosen stress and compared with the unadulterated material. A standard profilometer, a microhardness tester, and a scanning electron microscope were utilized to examine surface characteristics and measure roughness and hardness. Increased grinding speed in both wet and dry applications tended to decrease the fatigue life of the specimens. Fatigue life increased markedly at 2000 fpm under wet conditions, but then decreased at higher speeds. Grit size had no effect on the fatigue life.

Rangaswamy, P.↗

HP9-4-.30 weld properties and microstructure

HP9-4-.30, ultra high strength steel, the case material for the Advanced Solid Rocket Motor (ASRM), must exhibit acceptable strength, ductility, toughness, and stress corrosion cracking (SCC) resistance after welding and a local post weld heat treatment (PWHT). Testing, to date, shows that the base metal (BM) properties are more than adequate for the anticipated launch loads. Tensile tests of test specimens taken transverse to the weld show that the weld metal overmatches the BM even in the PWHT condition. However, that is still some question about the toughness and SCC resistance of the weld metal in the as welded and post weld heat treated condition. To help clarify the as welded and post weld heat treated mechanical behavior of the alloy, subsize tensile specimens from the BM, the fusion zone (FZ) with and without PWHT, and the heat affected zone (HAZ) with and without PWHT were tested to failure and the fracture surfaces subsequently examined with a scanning electron microscope. Results are given and briefly discussed.

Watt, George W.↗

Analysis of particulate contamination on tape lift samples from the VETA optical surfaces

Particulate contamination analysis was carried out on samples taken from the Verification Engineering Test Article (VETA) x-ray detection system. A total of eighteen tape lift samples were taken from the VETA optical surfaces. Initially, the samples were tested using a scanning electron microscope. Additionally, particle composition was determined by energy dispersive x-ray spectrometry. Results are presented in terms of particle loading per sample.

Germani, Mark S.↗