Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SYSTEM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Microsensor Technologies for Plant Growth System Monitoring

This document covered the following: a) demonstration of feasibility of microsensor for tube and particulate growth systems; b) Dissolved oxygen; c)Wetness; d) Flexible microfluidic substrate with microfluidic channels and microsensor arrays; e)Dynamic root zone control/monitoring in microgravity; f)Rapid prototyping of phytoremediation; and g) A new tool for root physiology and pathology.

Kim, Chang-Soo↗

Cavity Beam Position Monitor System for ATF2

The Accelerator Test Facility 2 (ATF2) in KEK, Japan, is a prototype scaled demonstrator system for the final focus required for a future high energy lepton linear collider. The ATF2 beam-line is instrumented with a total of 38 C and S band resonant cavity beam position monitors (CBPM) with associated mixer electronics and digitizers. The current status of the BPM system is described, with a focus on operational techniques and performance. The ATF2 C-band system is performing well, with individual CBPM resolution approaching or at the design resolution of 50 nm. The changes in the CBPM calibration observed over three weeks can probably be attributed to thermal effects on the mixer electronics systems. The CW calibration tone power will be upgraded to monitor changes in the electronics gain and phase. The four S-band CBPMs are still to be investigated, the main problem associated with these cavities is a large cross coupling between the x and y ports. This combined with the large design dispersion in that degion makes the digital signal processing difficult, although various techniques exist to determine the cavity parameters and use these coupled signals for beam position determination.

43 PARTICLE ACCELERATORS↗

A Greenhouse-Gas Information System - Monitoring and Validating Emissions Reporting and Mitigation - Chapter 2: Requirements Framework

The present study on a proposed greenhouse-gas information system (GHGIS) was undertaken without the benefit of requirements and specifications that will ultimately drive its choices and architecture. The discussion in this chapter attempts to develop a requirements framework that can be relied on to make choices between desired accuracy, precision, and confidence, vs. cost, schedule, and other elements. The accuracy or precision of the GHGIS (top-down) components required to validate reporting and international commitments depends on factors determined by the nature of the commitments as well as the goals of the users. The present study focuses on the task of measuring GHG emissions and attributing anthropogenic surface fluxes. This chapter explores possible emissions pathways that depart from targets and makes a number of assumptions about the needs of users to detect and quantify such departures, regardless of whether they are the result of inadvertent or willful reporting errors. Such user needs would be used to set GHGIS requirements.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

COMMON – Communications System Monitor v. 1.5

COMMON is a tool for collecting, storing, and displaying critical information to facilitate analysis on Microsoft Windows based IT systems. COMMON was developed to provide insight into the IT infrastructure for operational radiation detection systems, but is applicable to most Windows-based operating systems and TCP/IP network components. The COMMON tool aggregates a host of important Windows Management Instrumentation (WMI) information and as well as network ping responses to provide valuable insight into the performance of the IT system. A unique feature is the creation of daily output files (JSON) from the data collected for off site evaluation by subject matter experts.

Aragon, MonaL↗

Smart Composite Overwrapped Pressure Vessel - Integrated Structural Health Monitoring System to Meet Space Exploration and International Space Station Mission Assurance Needs

Currently there are no integrated NDE methods for baselining and monitoring defect levels in fleet for Composite Overwrapped Pressure Vessels (COPVs) or related fracture critical composites, or for performing life-cycle maintenance inspections either in a traditional remove-and-inspect mode or in a more modern in situ inspection structural health monitoring (SHM) mode. Implicit in SHM and autonomous inspection is the existence of quantitative accept-reject criteria. To be effective, these criteria must correlate with levels of damage known to cause composite failure. Furthermore, implicit in SHM is the existence of effective remote sensing hardware and automated techniques and algorithms for interpretation of SHM data. SHM of facture critical composite structures, especially high pressure COPVs, is critical to the success of nearly every future NASA space exploration program as well as life extension of the International Space Station. It has been clearly stated that future NASA missions may not be successful without SHM [1]. Otherwise, crews will be busy addressing subsystem health issues and not focusing on the real NASA mission

Saulsberry, Regor↗

Simulator evaluation of takeoff performance monitoring system displays

The development of head-up and head-down cockpit displays to convey symbolic status and advisory information to the pilot to aid him in his decision to continue or abort takeoff is described. It also describes a pilot-in-the-loop evaluation of the displays using the NASA Langley transport systems research vehicle fixed-base simulator. It was found that the head-up display was monitored with little effort and did not obstruct or distract from the runway scene.

Middleton, David B.↗

Field Trial of a Low-Cost, Distributed Plug Load Monitoring System

Researchers have struggled to inventory and characterize the energy use profiles of the ever-growing category of so-called miscellaneous electric loads (MELs) because plug-load monitoring is cost-prohibitive to the researcher and intrusive to the homeowner. However, these data represent a crucial missing link to understanding how homes use energy. Detailed energy use profiles would enable the nascent automated home energy management (AHEM) industry to develop effective control algorithms that target consumer electronics and other plug loads. If utility and other efficiency programs are to incent AHEM devices, they need large-scale datasets that provide statistically meaningful justification of their investments by quantifying the aggregate energy savings achievable. To address this need, NREL researchers investigated a variety of plug-load measuring devices available commercially and tested them in the laboratory to identify the most promising candidates for field applications. This report centers around the lessons learned from a field validation of one proof-of-concept system, called Smartenit (formerly SimpleHomeNet). The system was evaluated based on the rate of successful data queries, reliability over a period of days to weeks, and accuracy. This system offers good overall performance when deployed with up to 10 end nodes in a residential environment, although deployment with more nodes and in a commercial environment is much less robust. NREL concludes that the current system is useful in selected field research projects, with the recommendation that system behavior is observed over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chemo-thermo-piezoresistive highly sensing smart cement with integrated real-time monitoring system

The chemo-thermo-piezoresistive behavior of so-called “smart cement,” or cement modified with conductive fillers, is useful as a bulk sensor for monitoring the changes in the cement due to stresses, cracks, contamination, fluid loss, and temperature change that affect its performance. The smart cement utilizes a special conductive or semi-conductive filler and is useful as a bulk sensor that allows real-time monitoring of its properties.

Vipulanandan, Cumaraswamy↗

Field Trial of a Low-Cost, Distributed Plug Load Monitoring System

Researchers have struggled to inventory and characterize the energy use profiles of the ever-growing category of so-called miscellaneous electric loads (MELs) because plug-load monitoring is cost-prohibitive to the researcher and intrusive to the homeowner. However, these data represent a crucial missing link to our understanding of how homes use energy, and we cannot control what we do not understand. Detailed energy use profiles would enable the nascent automated home energy management (AHEM) industry to develop effective control algorithms that target consumer electronics and other plug loads. If utility and other efficiency programs are to incent AHEM devices, they need large-scale datasets that provide statistically meaningful justification of their investments by quantifying the aggregate energy savings achievable. To address this need, we have investigated a variety of plug-load measuring devices available commercially and tested them in the laboratory to identify the most promising candidates for field applications. The scope of this report centers around the lessons learned from a field validation of one proof-of-concept system, called Smartenit (formerly SimpleHomeNet). The system was evaluated based on the rate of successful data queries, reliability over a period of days to weeks, and accuracy. This system offers good overall performance when deployed with up to ten end nodes in a residential environment, although deployment with more nodes and in a commercial environment is much less robust. We conclude that the current system is useful in selected field research projects, with the recommendation that system behavior is observed over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Alignment monitoring system for the PIP-II cryomodules

The alignment of the SSR1 cryomodule components was studied as the acceptable beam deflection. We are showing an innovative alignment monitoring strategy through optical targets installed on the internal assembly.

43 PARTICLE ACCELERATORS↗

Automatic outdoor monitoring system for photovoltaic panels

Long-term acquisition of solar panel performance parameters, for panels operated at maximum power point in their real environment, is of critical importance in the photovoltaic research sector. However, few options exist for the characterization of non-standard panels such as concentrated photovoltaic systems, heavily soiled or shaded panels or those operating under non-standard spectral illumination; certainly, it is difficult to find such a measurement system that is flexible and affordable enough to be adopted by the smaller research institutes or universities. We present here an instrument aiming to fill this gap, autonomously tracking and maintaining any solar panel at maximum power point while continuously monitoring its operational parameters and dissipating the produced energy without connection to the power grid. Here, the instrument allows periodic acquisition of current-voltage curves to verify the employed maximum power point tracking approach. At the same time, with hardware schematics and software code being provided, it provides a flexible open development environment for the monitoring of non-standard generators like concentrator photovoltaic systems and to test novel power tracking approaches. The key issues, and the corresponding solutions, encountered in the design are analyzed in detail and the relevant schematics presented.

14 SOLAR ENERGY↗

Automated Iodine Monitoring System Development (AIMS)

The operating principle of the automated iodine monitoring/controller system (AIMS) is described along with several design modifications. The iodine addition system is also discussed along with test setups and calibration; a facsimile of the optical/mechanical portion of the iodine monitor was fabricated and tested. The appendices include information on shuttle prototype AIMS, preliminary prime item development specifications, preliminary failure modes and effects analysis, and preliminary operating and maintenance instructions.

Source record↗

A Web-Based Monitoring System for Multidisciplinary Design Projects

In today's competitive environment, both industry and government agencies are under pressure to reduce the time and cost of multidisciplinary design projects. New tools have been introduced to assist in this process by facilitating the integration of and communication among diverse disciplinary codes. One such tool, a framework for multidisciplinary computational environments, is defined as a hardware and software architecture that enables integration, execution, and communication among diverse disciplinary processes. An examination of current frameworks reveals weaknesses in various areas, such as sequencing, displaying, monitoring, and controlling the design process. The objective of this research is to explore how Web technology, integrated with an existing framework, can improve these areas of weakness. This paper describes a Web-based system that optimizes and controls the execution sequence of design processes; and monitors the project status and results. The three-stage evolution of the system with increasingly complex problems demonstrates the feasibility of this approach.

Rogers, James L.↗