Stable, Thermally Conductive Fillers for Bolted Joints

A commercial structural epoxy [Super Koropon (or equivalent)] has been found to be a suitable filler material for bolted joints that are required to have large thermal conductances. The contact area of such a joint can be less than 1 percent of the apparent joint area, the exact value depending on the roughnesses of the mating surfaces. By occupying the valleys between contact peaks, the filler widens the effective cross section for thermal conduction. In comparison with prior thermal joint-filler materials, the present epoxy offers advantages of stability, ease of application, and -- as a byproduct of its stability -- lasting protection against corrosion. Moreover, unlike silicone greases that have been used previously, this epoxy does not migrate to contaminate adjacent surfaces. Because this epoxy in its uncured state wets metal joint surfaces and has low viscosity, it readily flows to fill the gaps between the mating surfaces: these characteristics affect the overall thermal conductance of the joint more than does the bulk thermal conductivity of the epoxy, which is not exceptional. The thermal conductances of metal-to-metal joints containing this epoxy were found to range between 5 and 8 times those of unfilled joints.

LeVesque, Raymond J., II↗

Monitoring and characterization of particle contamination in the pulse compression chamber of the OMEGA EP laser system

The laser-damage performance of optics is known to be negatively affected by microscale particle contamination induced by the operational environment. This work investigates the properties of particles accumulating in various locations near critical optics inside the OMEGA EP grating compressor chamber during quarterly operational periods over a 2-year duration. The particles found were characterized using optical microscopy, scanning electron microscopy and energy dispersive X-ray spectroscopy. The analysis indicates significant concentrations of micrometer- to nanometer-scale particles inside the vacuum chamber, with higher values observed near the port leading to the OMEGA EP target chamber. The distribution of the chemical composition of these particles varies between collection periods. Although understanding of the mechanisms of particle generation and transport remains uncertain, the hypothesis is that this particle load represents a risk for contaminating the surfaces of high-value optics located inside the chamber, including the compression gratings and deformable mirrors, and therefore affecting their laser-damage resistance and overall operational lifetime.

47 OTHER INSTRUMENTATION↗

Techniques for Measurement of Nitrate Movement in Soils

Contamination of surface and ground waters with nitrate usually involves leaching through soil of nitrate produced by mineralization of soil organic matter, decomposition of animal wastes or plant residues, or derived from fertilizers. Nitrate concentrations in the soil solution may be measured by several chemical procedures or by the nitrate electrode. since nitrate is produced throughout the soil mass it is difficult to identify a source of nitrate contamination by conventional means. This problem can be solved by use of N-15-enriched or N-15-depleted materials as tracers. The latter is particularly attractive because of the negligible possibility of the tracer hazardous to health.

Broadbent, F. E.↗

Assessment of shuttle payloads gaseous environment contamination and its control

A prediction is given of the in-orbit gaseous environment and the contamination it could produce on cryogenic and room temperature surfaces of payloads in the shuttle bay. The time varying environment was obtained by the superposition of the calculated shuttle environment for a discrete time and payload induced environments measured in large space chambers. Representative contaminant surface accretions were calculated for flights 1 week and 1 month long for payloads having the largest source of outgassing and an orbit of 200 km. A number of calculations were based on the magnitude of the sources, the molecular natures, the decay rate with time, the sticking coefficients, the view factors, and the temperatures of the surfaces being contaminated. Significant results are reported.

Scialdone, J. J.↗

Chemical-Biological Cyclic Process for Hexavalent Chromium Reduction to Trivalent Chromium in Aqueous Medium - 20224

Conventional treatment of chromium contamination focuses on immobilization of the highly toxic and water-soluble form Cr(VI), by reducing it to the relatively less toxic and less mobile trivalent form, Cr(III), using reducing compounds like ferrous sulfate or ferrous iron, Fe(II). The Cr(VI) also respond to biodegradation and subsequent reduction. During the reduction reaction, Fe(II) is oxidized to ferric, Fe(III), which, being at the highest oxidation state, has no ability to reduce Cr(VI), and therefore remediation process terminates. The good news is that metal-reducing bacteria, S. oneidensis MR-1, can regenerate Fe(II) from Fe(III) with the help of an organic electron donor in an appropriate bacterial media. Thus, in the Cr(VI) chemical remediation process, Fe(II) to Fe(III) conversion is reversed by the biological process, regenerating Fe(II) and the Cr(VI) chemical reduction process continues in a cyclic fashion. This study presents the results of regeneration of Fe(II) from fresh Fe(III) as well as from the reaction products of Cr(VI) and Fe(II). Both fresh Fe(III) and reaction product Fe(III) exhibited the same reduction behavior. Fe(II) production increased with the increase of initial concentration of Fe(III), resulting in 87.5% Fe(II) regeneration. The extent of Fe(III) reduction (Fe(II)t/Fe(III)0.hour) was 21 times higher than the extent of Cr(VI) reduction (Cr(VI)t/Cr(VI)0.hour) by S. oneidensis MR-1. In a cyclic process of sequential Cr(VI) addition, the amount of Fe(II) regeneration decreased with the increase in cycle number, a fixed quantity of starting S. oneidensis MR-1 could regenerate Fe(II) at least five times in a ten-hour period. More importantly, regenerated Fe(II) instantly reduced Cr(VI) to Cr(III). So, Fe(II) regeneration with metal-reducing bacteria has a good potential for application in groundwater and wastewater remediation in reducing Cr(VI) to Cr(III). As a comparison of chemical to biological transformation, chemical transformation of Cr(VI) by Fe(II) was almost 600 times greater than that of biological transformation. Therefore a chemical-biological cyclic process offers potential applications for remediation of groundwater and hexavalent chromium contaminated waste sites. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Challenges of Air Monitoring at a Soil Remediation Project in a Suburban Setting - 20448

Air monitoring during soil excavation at a chemically and radiologically impacted site in a suburban setting presents unique challenges. Site activities were conducted in a manner that minimized the release of airborne particulates of concern, principally radionuclides of concern (ROC). Dust and air monitoring were performed to ensure the public was not being exposed to the soil contaminants. The project team collected representative air and dust data while being mindful to not impose on the lives of residents in the area. Due to the close proximity to the public, there was a high level of oversight from the client and regulatory agencies. The challenges involved with air sampling at this soil remediation site located in a suburban setting included the number of contaminants, the ranges of risks and hazards presented by the contaminants and the method of remediation, the concerns of the regulators and the public, and the perception of risk from the public. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Engine Plume Interaction Calculations for Prototypical Prometheus 1

Prometheus 1 is a conceptual mission to demonstrate the use of atomic energy for distant space missions. The hypothetical spacecraft design considered in this paper calls for multiple ion thrusters, each with considerably higher beam energy and beam current than have previously flown in space. The engineering challenges posed by such powerful thrusters relate not only to the thrusters themselves, but also to designing the spacecraft to avoid potentially deleterious effects of the thruster plumes. Accommodation of these thrusters requires good prediction of the highest angle portions of the main beam, as well as knowledge of clastically scattered and charge exchange ions, predictions for grid erosion and contamination of surfaces by eroded grid material, and effects of the plasma plume on radio transmissions. Nonlinear interactions of multiple thrusters are also of concern. In this paper we describe two- and three-dimensional calculations for plume structure and effects of conceptual Prometheus 1 ion engines. Many of the techniques used have been validated by application to ground test data for the NSTAR and NEXT ion engines. Predictions for plume structure and possible sputtering and contamination effects will be presented.

Mandell, Myron J.↗

Success Using A Granular-Activated Carbon Filtration Swab to Rehabilitate Westbay{sup R} Multi-level Groundwater Monitoring Wells at the INL - 20544

In November 2015, tetrachloroethylene (PCE) was discovered in groundwater samples collected from a Westbay{sup R} multi-level groundwater monitoring well at the Idaho National Laboratory (INL).a Subsequent investigation determined that PCE was not present in the groundwater. The detected PCE was instead due to inadvertent contamination of the internal tubing fluid in the Westbay well-monitoring system, which is isolated from the surrounding groundwater. Further investigation showed that three of the 11 Westbay wells at the INL contained PCE-contaminated tubing fluid at concentrations above the U.S. Environmental Protection Agency's maximum contaminant level for drinking water (5 μg/L). Loose sediment at the bottom of some Westbay wells was also found to contain PCE; the three wells were then identified for rehabilitation as part of the INL well maintenance program. The unique construction of the Westbay wells - i.e., the small diameter (5.72 cm [2.25 in.]) and the depths of the tubing fluid ranging from 144.8 to 419 m (475 to 1,376 ft) below ground surface - posed unique challenges to the rehabilitation. Because the tubing fluid provides structural integrity, the fluid cannot be removed and then replaced without damaging the integrity of the Westbay well. Additionally, the small diameter of the systems and the associated depths limit the availability of equipment that can be used for the rehabilitation. After an evaluation of potential methods, it was determined that the use of an in-well, custom-fabricated, granular-activated-carbon filtration swab deployed via a wire line would provide the safest and most cost-effective method for rehabilitation. Westbay well rehabilitation started at well MIDDLE-2051 in late June 2018 and paused in December 2018 for the season. The PCE concentration in the tubing fluid at MIDDLE-2051 was initially reduced to a maximum concentration of 3.81 μg/L from a maximum of 642 μg/L, while the concentration of PCE in the sediment had been reduced from 5,360 to 2,270 μg/kg. Sampling was performed at MIDDLE-2051 again in August 2019, and the tubing fluid increased to a maximum concentration of 45.4 μg/L, while the concentration in the sediment decreased further to 1,890 μg/kg due to desorption of PCE from the sediment to the tubing fluid. Rehabilitation resumed at well MIDDLE-2050A in late August 2019, and the PCE concentration in the tubing fluid had been reduced to a maximum concentration of 19.0 μg/L. Although the method has been shown to be time-consuming, it has proven to be effective and safe for personnel performing the work and to the integrity of the well. Future sample data results at all wells will help determine an estimated completion of the rehabilitation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Emerging Contaminants: Identification, Life Cycle, and Key Challenges - 20415

The term 'emerging contaminants' and its multiple variants has come to refer to previously overlooked compounds discovered in the environment which represent a potential threat to human and ecological receptors. These compounds may be discovered in the environment as new analytical techniques are developed and/or as new monitoring programs for drinking water and groundwater are implemented, while the threat to receptors may be realized through advances in understanding of toxicology and pathways to receptors. Emerging contaminants present unique and considerable challenges as demands to address them can outpace the understanding of their toxicity, their need for regulation, their occurrence, and techniques for treating the environmental media they affect. With these challenges in mind, this paper serves as a primer for understanding emerging contaminants. The paper will lay a foundation for understanding emerging contaminants through three key topics: 1. Who identifies emerging contaminants? An overview of the various stakeholder groups around the world working on identifying potential emerging contaminants and developing systems for screening potential candidates, prioritizing, and ultimately generating regulations will be provided. 2. How Chemicals Rise into Awareness as Emerging Contaminants. The process by which contaminants emerge through a cycle of awareness, characterization, management and regulation will be discussed. Current emerging contaminants will be discussed in the context of the life cycle: emerging contaminants where impacts to drinking water supplies are driving public awareness (e.g. per and polyfuoroalkyl substances (PFASs) and 1,4-dioxane), emerging contaminants impacted by changing regulatory standards or development and debate on toxicity (e.g., hexavalent chromium, 1,2,3-trichloropropane, trichloroethylene in vapor intrusion), and those with evolving understanding of impacts and usage (e.g., microplastics). 3. Key Challenges. Unique challenges associated with emerging contaminants, including visibility and public sensitivity, uncertainty and vulnerability, will be discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of a Soil Flushing Treatability Test for Hanford Site Hexavalent Chromium Removal - 20446

U.S. Department of Energy contractor CH2M Hill Plateau Remediation Company has made significant progress remediating hexavalent chromium in groundwater near the Columbia River through the operation of pump and treat facilities and source removal activities. To mitigate risks associated with hexavalent chromium contamination, which was identified in a CERCLA interim action record of decision as the primary groundwater contaminant of concern for the 100-KR-4 Operable Unit from discharging to the Columbia River, three ion-exchange pump and treat systems were installed between 1997 and 2009. Between 2010 and 2016, operation of the K West pump and treat system, located near the former 105K West plutonium production reactor, reduced concentrations below the groundwater remediation target for hexavalent chromium. In 2016, a rebound study was performed to evaluate the effectiveness of the pump and treat remedy and assess the potential for any residual hexavalent chromium sources continuing to contribute to groundwater contamination. As a result of the rebound study, a source of continued groundwater contamination was identified. To address this condition, a soil flushing treatability test was written and approved by the U.S. Department of Energy and the U.S. Environmental Protection Agency. The test included saturating about a 1-acre area of soil with treated water with the goal of forcing the residual hexavalent chromium to groundwater where existing extraction wells could remove it for treatment, accelerating the cleanup process. In spring and summer 2019, CH2M Hill Plateau Remediation Company installed and began operating a shallow underground leach system to support the treatability test. Preliminary sampling data show the test was effective in removing the residual contamination. Following further evaluation and analysis from the initial test, the process will be considered for implementation elsewhere on the Hanford Site, particularly at locations where there is a known or suspected continuing contamination source in the soil column. The paper will cover the goals of the study, as well as more details about the following: - Overview of pump and treat exit strategy (using U.S. Environmental Protection Agency guidance); - The design and installation of the soil flushing technology in the 100-K Area; - The testing process and results of sampling data; - Post-study evaluation and potential for implementation in other locations at the Hanford Site. Innovative solutions for cleanup, such as the soil flushing technology, have resulted in substantial progress in the removal of groundwater contaminants at the Hanford Site, potentially shortening the time frame required to meet cleanup goals and resulting in significant cost savings. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Whose Gas is it anyway? Differentiating the Source of a Large Soil Vapor Plume beneath Two Adjacent Waste Sites - 20487

DOE contractor CH2M Hill Plateau Remediation Company is currently responsible for conducting groundwater contamination monitoring at several RCRA treatment, storage, and disposal units located on the Hanford Site in Richland, Washington State. The Nonradioactive Dangerous Waste Landfill treatment, storage, and disposal unit presents a distinct groundwater monitoring problem because of a large multi-contaminant soil vapor plume beneath it that is a likely source of low-level volatile organic compound groundwater contamination. Adjacent to Nonradioactive Dangerous Waste Landfill is the Solid Waste Landfill. Volatile organic compounds are inventory components of both the Nonradioactive Dangerous Waste Landfill and the Solid Waste Landfill. Therefore, it is possible that both sites could be contributing to the soil vapor plume. For regulatory purposes, it is important to differentiate which site is the primary contributor of volatile organic compounds to the plume. An approach was developed to identify the primary volatile organic compound source of the soil vapor plume beneath Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill. The site conceptual model hypothesis of vapor-phase volatile organic compound transport to the dissolved phase in groundwater was tested by a simple mathematical model of vapor/liquid equilibrium concentrations at the groundwater/air interface. Once it was shown that vapor-phase volatile organic compound transport to groundwater was a valid conceptual model for Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill, spatial and statistical methods were used to determine the primary site contributing to the majority of volatile organic compounds to the soil vapor plume. Average groundwater chloroform, tetrachloroethene, and trichloroethene concentrations from Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill monitoring network wells were plotted on maps of the facilities and immediate vicinities and compared to soil vapor sampling probe locations. Principal component analysis and mixing ratios were used to identify source contributions of each treatment, storage, and disposal unit to the plume. Results of the vapor/liquid equilibrium concentrations mathematical model showed that transport phenomena outweigh steady-state equilibria. Estimated vapor/liquid equilibrium concentrations were considerably lower than soil vapor measurements. The results indicate that dynamic vadose zone and groundwater factors such as decreased vapor concentrations with depth, vapor dilution from dispersion in the vadose zone, and advective and diffusional volatile organic compound dilution in groundwater result in groundwater volatile organic compound concentrations much less than would be measured under steady-state equilibrium conditions. Site source contribution differentiation by principal component analysis and mixing ratios was inconclusive using actual soil gas data because of the similarity in concentration values in both datasets for Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill. Similar data populations suggest mixing of the vapor contributions from both sites by dispersion through the soil matrix pore spaces. However, when groundwater volatile organic compound data were compared between the Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill monitoring networks, Solid Waste Landfill mean concentrations were higher, suggesting more vapor-phase volatile organic compound transport to groundwater at those locations. Simulated volatile organic compound soil vapor and groundwater datasets created to test the methods developed for this study show that the method can be successful in source differentiation when significantly different datasets are compared. This paper will describe a method of testing a conceptual model for vapor-phase contaminant transport to groundwater and for differentiating site sources of contaminants comprising a mixed-constituent soil vapor plume. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Plasma Surface Functionalization of AFP Manufactured Composites for Improved Adhesive Bond Performance

Application of carbon fiber reinforced polymer (CFRP) as a high-performance structural material has widespread application in the present aerospace industry. However, as-processed composite materials require a comprehensive surface treatment prior to bonding to remove contaminants and impart surface functionality and topography to overcome their poor adhesion properties. Atmospheric pressure plasma jet treatment (APPJT) has been increasingly garnering attention as an alternate method for surface preparation of CFRP. This method has been reported to achieve success in imparting favorable polar functional groups into the composite surfaces enhancing wettability and surface energy of the bonded surfaces. In some cases, APPJT has been demonstrated to remove contaminants or, in the case of silicones, convert them to silica. In this study, an atmospheric pressure plasma jet (APPJ) system was used for surface activation of a composite laid-up by an automated fiber placement (AFP) machine. Surface modifications prior to and after treatment were characterized using water contact angle (WCA) measurements, X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), and atomic force microscopy (AFM). Double cantilever beam (DCB) tests were performed to quantify the bonding performance of the composites. The results show a marked enhancement of the mode I interlaminar fracture toughness with the application of APPJT.

Sarikaya, Ibrahim↗

Amplicon Sequencing Assessment to Measure Microbial Community Response from Heavy Metal Contaminated Soils in Savannah River site, Tims Branch watershed

Long-term presence of heavy metal contamination in soils is correlated with changes in microbial community structures and can lead to the reduction of indigenous species. Tolerance to soil heavy metal toxicity varies among different microbial communities. It remains unclear whether long term effects caused by metal perturbations are associated with soil microbial community dysregulation in Tims Branch watershed. Research Questions: Does heavy metal contamination in Tims Branch soils decrease microbial species diversity significantly compared to non-contaminated soils? Does the species richness decrease in contaminated samples? between samples? Is diversity in low, mid and high contamination soils significantly different compared to control samples? Hypothesis: The relative abundance and diversity of species are significantly altered in soils which are contaminated with heavy metals in the Tims Branch watershed. Objectives: Use amplicon sequencing technology along with bioinformatics to compare bacterial communities between four sites in Tims Branch watershed. Evaluate the percent relative abundance and diversity across the site. Conclusions: All bacterial communities exposed to different heavy metal concentrations were dominated by four major groups (Proteobacteria, Acidobacteria, Chloroflexi and Verrucomicrobia). The dominant phyla Proteobacteria, Acidobacteria and Chloroflexi accounted for 61 % of the relative abundance. Soil bacterial α-diversity, expressed as observed species richness metric and Shannon's diversity index, was the highest in sample location four (high contamination). The lowest observed was at the control location. Species richness increased when concentrations of heavy metals were localized, inferring that the metals can alter microbial community structure. PERMANOVA analysis between contaminated groups tested significant using the Adonis (F (4,29) =1.9712; p < 0.001). There is a 20 percent variation explained between groups (R2 = 0.214). This analysis proves to be beneficial in detecting microbial communities altered by contaminated soils. Moreover, certain concentrations of heavy metals can alter microbial community structures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Panel Session 100: An Integrated Systems-Based Monitoring Approach

This panel focused on recent advancements in monitoring and remaining challenges associated with the implementing cost-effective monitoring approaches for complex DOE sites. Monitoring presents one of the largest, long-term costs for environmental remediation and site stewardship within the DOE because contamination at complex sites will likely be present for tens to hundreds of years into the future. Integration of monitoring with predictive modeling is an approach that can reduce long-term monitoring costs as well as support the effective monitoring design and data interpretation for managing a site toward closure and long-term stewardship. Panelists with presentations: Autonomous Electrical Geophysical Monitoring of Contaminated Sites (Tim Johnson); Systems Based Long-Term Monitoring for DOE Legacy Management (David Shafer); Long-Term Systems Based Monitoring (Anderson Ward)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Understanding and Mitigating the Contamination of Intrinsic poly-Si Gaps in Passivated IBC Solar Cells

We investigate factors that are critical for the performance of interdigitated back contact (IBC) solar cells based on polycrystalline silicon (poly-Si) passivated contacts. During patterning of doped lines using direct plasma deposition through a shadow mask, we show that the intrinsic poly-Si gap becomes contaminated with dopants, leading to shunting. Possible contamination mechanisms during masked deposition and high- temperature annealing are tested. Strategies developed to mitigate the contamination, such as reactive ion etching after deposition and amorphous to poly-Si crystallization in oxygen, will lead to improved IBC fabrication methods.

14 SOLAR ENERGY↗

Investigation of Radiological Contamination at Parks in the Gateway National Recreation Area - 20350

In 2005, the National Park Service was notified that elevated radiation levels were detected at Great Kills Park during a baseline radiological mapping effort conducted by the Counter Terrorism Bureau of the New York City Police Department and the United States Department of Energy. Great Kills Park is in the Staten Island Unit of the Gateway National Recreation Area. A records search determined that approximately 280 acres of the park was established over an area in which the New York City Department of Sanitation placed approximately 15.1 million cubic yards of waste fill from 1944 to 1948. Since 2005, a series of response actions and investigations were conducted on behalf of the National Park Service to mitigate risk to human health and the environment and to determine the nature of radiological contamination at Great Kills Park. The findings support that radiological contamination is related to certain components of waste fill, including incinerator residue from both on and offsite incinerators, coal ash from the historical use of coal-fired boilers for heating, and incidental radiological artifacts in the waste fill due to their historical use and subsequent disposal. A majority of the radiological artifacts were determined to contain radium-226 and included radioluminescent markers, radium impregnated switch board buttons, radium paint containers, and brachytherapy devices. The National Park Service has several other Parks in the Gateway National Recreation Area that were established in areas with a similar history to Great Kills Park, and overlie waste fill historically placed during landfilling operations, including Spring Creek Park and Dead Horse Bay. Over the last year, the National Park Service has performed additional radiological investigations at Great Kills Park as part of the ongoing Remedial Investigation under the Comprehensive Environmental Response, Compensation, and Liability Act. In addition, preliminary radiological investigations were performed at Spring Creek Park and Dead Horse Bay Park in the Jamaica Bay Unit of Gateway National Recreation Area. These investigation activities identified gamma radiation levels above the ambient level, several of which were attributable to radiological artifacts similar in nature to those recovered at Great Kills Park. Ongoing investigations at Parks in the Gateway National Recreation Area support an association between radiological contamination and historical landfilling practices that were common prior to the regulation and control of radioactive materials. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Friction behavior of members of the platinum metals group with gold

The adhesion and friction behavior of the platinum metals group was examined with clean surfaces and surfaces selectively contaminated with oxygen, vinyl chloride (C2H3Cl), and methyl mercaptan (CH3SH). A pin or disk specimen configuration was used with the pin being a single crystal of gold of the (111) orientation and with the platinum metal disks also being single crystals of the (111) or (0001) orientation. Loads applied ranged from 1 to 10 g and a sliding velocity of 0.7 mm/min was employed. Results indicate adhesion and transfer of gold to all of the platinum metals. Despite this observation friction differences existed among the metals in the group. These differences are related to surface chemical activity. Adsorption of various friction reducing species was selective. With some adsorbates present strong adhesive forces between metals were still observed.

Buckley, D. H.↗

Ignition propagation and heat effects of propellant chips embedded in castable inhibitor using a laser flux test bomb

A castable inhibitor is applied to the aft face of the Space Shuttle Redesigned Solid Rocket Motor (RSRM) forward segment propellant grain to control propellant surface burn area. During fabrication, the propellant surface is trimmed prior to the inhibitor application. This produces a potential for small propellant chips to remain undetected on the propellant surface and contaminate the inhibitor during application. The concern was that undetected propellant chips in the inhibitor might provide a fuse path for premature propellant ignition underneath the inhibitor. To evaluate the fuse path potential, testing was performed on inhibitor samples with embedded propellant. The internal motor environment was simulated with a calibrated CO2 laser beam directed onto a sample which was placed in a 4100 kPa (600 psi) nitrogen pressurized bomb (laser bomb). The testing showed definitive results pertaining to fuse path formation. Embedded propellant chips did not autoignite until the receding heat affected inhibitor surface reached, or passed, the propellant chip. Samples with embedded propellant chips in alignment did not propagate ignition from one chip to another with separation distances as small as 0.010 cm(0.004 inc) and some as little as 0.0051 cm (0.002 in). Propellant chips with volumes approximately less than 0.025 cu cm (0.0015 cu in) (which did not propagate ignition) did not increase the inhibitor material decomposition depth more than the resulting void cavity of the burned out propellant chip. In addition, the depth of this void cavity did not increase until it was overtaken by the surrounding material decomposition depth. This was due, in part, to the retention of the protective inhibitor char layer. Samples with embedded propellant strings, whose thicknesses were below 0.023 cm (0.009 in), did not propagate ignition. Propellant string thicknesses above 0.038 cm (0.015 in) did propagate ignition. Test sample char and heat affected layer measurements and observations compared well with those from the Space Shuttle Solid Rocket Motor (SRM) Technical Evaluation Motor no. 9(TEM-9).