Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SHIFT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Wavelength Shifting in InP based Ultra-thin Quantum Well Infrared Photodetectors

We have demonstrated red-shifting of the wavelength response of a bound-to-continuum p-type ultra-thin InGaAs/Inp quantum well infrared photodetector after growth via rapid thermal annealing. Compared to the as-grown detector, the peak spectral response of the annealed detector was shifted to longer wavelength without any major degradation in responsivity characteristics.

Photodetector Thermal Annealing↗

Molecular implementation of molecular shift register memories

An electronic shift register memory (20) at the molecular level is described. The memory elements are based on a chain of electron transfer molecules (22) and the information is shifted by photoinduced (26) electron transfer reactions. Thus, multi-step sequences of charge transfer reactions are used to move charge with high efficiency down a molecular chain. The device integrates compositions of the invention onto a VLSI substrate (36), providing an example of a molecular electronic device which may be fabricated. Three energy level schemes, molecular implementation of these schemes, optical excitation strategies, charge amplification strategies, and error correction strategies are described.

Beratan, David N.↗

Nitrogen-Pressure Shifts in the v3 Band of Methane Measured at Several Temperatures between 300 and 90 K

Remote sensing of the Earth's atmosphere requires accurate knowledge of spectroscopic line parameters for the molecules investigated. Knowledge of the temperature dependence of these parameters is also essential if agreement, at the noise level, between calculated and experimental data is to be achieved. The authors recently published results of nitrogen broadening measurements in the v3 band of 12CH4 using the 5.37 m long absorption path length all-copper Herriott cell. The temperature dependent line parameters determined in the laboratory were applied to fit a portion of the atmospheric spectrum recorded with a balloon-borne remote sensing FTIR instrument, called the Limb Profile Monitor of the Atmosphere, and operating in absorption against the sun. Since the authors had a relatively complete series of data for the P(9) transition in the v3 band of 12CH4, the A2 1 as well as the F2 1, F1 1 and A1 1 lines recorded at different pressures and at four temperatures between 300 and 90 K, we reanalyzed the data to derive pressure shift information at different temperatures. The temperatures for which data were collected and analyzed are 298, 140 and 90K. The high precision pressure shift data obtained here over a large range of temperature demonstrate the ability of our experimental arrangement to address specific questions on a given spectral window like in the balloon experiment or in a satellite project, for example.

Tumuhimbise, Anthony T.↗

Efficacy of Compression Garments to Simulate Fluid Shifts during Lunar Bedrest

The effectiveness of JOBST(Registered TradeMark) compression stockings for fluid redistribution was examined in the lunar bed rest analog based on Digital Astronaut computer model predictions. NASA's future goals include missions to the moon which will require extended exposure to the lunar gravity environment. To prepare for these missions, physiological adaptations in various systems must be resolved. A bed rest at a 10 degree head-up tilt was used to simulate lunar gravity. Plasma volume (PV) loss may cause some of the cardiovascular adaptations which occur during space flight so PV is measured in the bed rest analog to evaluate fluid loss. PV varies from individual to individual so PV index (PVI) is used to determine the magnitude and time course of fluid shift and cardiovascular adaptation to 1/6 g. The Digital Astronaut, a computer simulation tool, predicts a 6% PV loss during an extended simulated lunar mission for a male with a body surface area of 1.95 m(exp 2). Simple geometry calculations suggest that 10 degree head-up tilt is most useful for simulated measurement of deconditioning in bone and muscle, however, 2 degree head-up tilt may best imitate cardiovascular fluid shifts. In order to reconcile these different models, compression stocking must be used in the 10 degree paradigm to better approximate expected cardiovascular changes.

Brinley, Alaina↗

Development of the One-Sided Nonlinear Adaptive Doppler Shift Estimation

The new development of a one-sided nonlinear adaptive shift estimation technique (NADSET) is introduced. The background of the algorithm and a brief overview of NADSET are presented. The new technique is applied to the wind parameter estimates from a 2-micron wavelength coherent Doppler lidar system called VALIDAR located in NASA Langley Research Center in Virginia. The new technique enhances wind parameters such as Doppler shift and power estimates in low Signal-To-Noise-Ratio (SNR) regimes using the estimates in high SNR regimes as the algorithm scans the range bins from low to high altitude. The original NADSET utilizes the statistics in both the lower and the higher range bins to refine the wind parameter estimates in between. The results of the two different approaches of NADSET are compared.

Beyon, Jeffrey Y.↗

Using Doppler Shifts of GPS Signals To Measure Angular Speed

A method has been proposed for extracting information on the rate of rotation of an aircraft, spacecraft, or other body from differential Doppler shifts of Global Positioning System (GPS) signals received by antennas mounted on the body. In principle, the method should be capable of yielding low-noise estimates of rates of rotation. The method could eliminate the need for gyroscopes to measure rates of rotation. The method is based on the fact that for a given signal of frequency ft transmitted by a given GPS satellite, the differential Doppler shift is attributable to the difference between those components of the instantaneous translational velocities of the antennas that lie along the line of sight from the antennas to the GPS satellite.

Campbell, Charles E., Jr.↗

Astrometric "Core-shifts" at the Highest Frequencies

We discuss the application of a new VLBI astrometric method named "Source/Frequency Phase Referencing" to measurements of "core-shifts" in radio sources used for geodetic observations. We detail the reasons that astrometrical observations of 'core-shifts' have become critical in the era of VLBI2010. We detail how this new method allows the problem to be addressed at the highest frequencies and outline its superior compensation of tropospheric errors.

Rioja, Maria↗

A Phase-Shifting Zernike Wavefront Sensor for the Palomar P3K Adaptive Optics System

A phase-shifting Zernike wavefront sensor has distinct advantages over other types of wavefront sensors. Chief among them are: 1) improved sensitivity to low-order aberrations and 2) efficient use of photons (hence reduced sensitivity to photon noise). We are in the process of deploying a phase-shifting Zernike wavefront sensor to be used with the realtime adaptive optics system for Palomar. Here we present the current state of the Zernike wavefront sensor to be integrated into the high-order adaptive optics system at Mount Palomar's Hale Telescope.

adaptive optics↗

Computational Modeling of Cephalad Fluid Shift for Application to Microgravity-Induced Visual Impairment

An improved understanding of spaceflight-induced ocular pathology, including the loss of visual acuity, globe flattening, optic disk edema and distension of the optic nerve and optic nerve sheath, is of keen interest to space medicine. Cephalad fluid shift causes a profoundly altered distribution of fluid within the compartments of the head and body, and may indirectly generate phenomena that are biomechanically relevant to visual function, such as choroidal engorgement, compromised drainage of blood and cerebrospinal fluid (CSF), and altered translaminar pressure gradient posterior to the eye. The experimental body of evidence with respect to the consequences of fluid shift has not yet been able to provide a definitive picture of the sequence of events. On earth, elevated intracranial pressure (ICP) is associated with idiopathic intracranial hypertension (IIH), which can produce ocular pathologies that look similar to those seen in some astronauts returning from long-duration flight. However, the clinically observable features of the Visual Impairment and Intracranial Pressure (VIIP) syndrome in space and IIH on earth are not entirely consistent. Moreover, there are at present no experimental measurements of ICP in microgravity. By its very nature, physiological measurements in spaceflight are sparse, and the space environment does not lend itself to well-controlled experiments. In the absence of such data, numerical modeling can play a role in the investigation of biomechanical causal pathways that are suspected of involvement in VIIP. In this work, we describe the conceptual framework for modeling the altered compartmental fluid distribution that represents an equilibrium fluid distribution resulting from the loss of hydrostatic pressure gradient.

Nelson, Emily S.↗

Air- and Self-Broadened Half Widths, Pressure-Induced Shifts, and Line Mixing in the Nu(sub 2) Band of (12)CH4

Lorentz self- and air-broadened half width and pressure-induced shift coefficients and their dependences on temperature have been measured from laboratory absorption spectra for nearly 130 transitions in the nu(sub 2) band of (12)CH4. In addition line mixing coefficients (using the relaxation matrix element formalism) for both self- and airbroadening were experimentally determined for the first time for a small number of transitions in this band. Accurate line positions and absolute line intensities were also determined. These parameters were obtained by analyzing high-resolution (approx. 0.003 to 0.01 per cm) laboratory spectra of high-purity natural CH4 and air-broadened CH4 recorded at temperatures between 226 and 297 K using the McMath-Pierce Fourier transform spectrometer (FTS) located at the National Solar Observatory on Kitt Peak, Arizona. A multispectrum nonlinear least squares technique was used to fit short (5-15 per cm) spectral intervals in 24-29 spectra simultaneously. Parameters were determined for nu(sub 2) transitions up to J" = 16. The variations of the measured broadening and shift parameters with the rotational quantum number index and tetrahedral symmetry species are examined. The present results are also compared with previous measurements available in the literature.

Smith, M. A. H.↗

Phase-Shifting Zernike Interferometer Wavefront Sensor

The canonical Zernike phase-contrast technique transforms a phase object in one plane into an intensity object in the conjugate plane. This is done by applying a static pi/2 phase shift to the central core (approx. lambda/diameter) of the PSF which is intermediate between the input and output plane. Here we present a new architecture for this sensor. First, the optical system is simple and all reflective, and second the phase shift in the central core of the PSF is dynamic and can be made arbitrarily large. This common-path, all-reflective design makes it minimally sensitive to vibration, polarization and wavelength. We review the theory of operation, describe the optical system, summarize numerical simulations and sensitivities and review results from a laboratory demonstration of this novel instrument.

Zernike phase-contrast↗

Phase-Shifting Zernike Interferometer Wavefront Sensor

The canonical Zernike phase-contrast technique1,2,3,4 transforms a phase object in one plane into an intensity object in the conjugate plane. This is done by applying a static pi/2 phase shift to the central core (approx. lambda/D) of the PSF which is intermediate between the input and output planes. Here we present a new architecture for this sensor. First, the optical system is simple and all reflective. Second, the phase shift in the central core of the PSF is dynamic and or arbitrary size. This common-path, all-reflective design makes it minimally sensitive to vibration, polarization and wavelength. We review the theory of operation, describe the optical system, summarize numerical simulations and sensitivities and review results from a laboratory demonstration of this novel instrument

wavefront sensing↗

Helium Pressure Shift of the Hyperfine Clock Transition in Hg-201(+)

There are two stable odd isotopes of mercury with singly ionized hyperfine structure suitable for a microwave atomic clock: Hg-199(+) and Hg-201(+). We are investigating the viability of a trapped ion clock based on Hg-201(+) in a configuration that uses a buffer gas to increase ion loading efficiency and counter ion heating from rf trapping fields. Traditionally, either helium or neon is used as the buffer gas at approx. 10(exp -5) torr to confine mercury ions near room temperature. In addition to the buffer gas, other residual background gasses such as H2O, N2, O2, CO, CO2, and CH2 may be present in trace quantities. Collisions between trapped ions and buffer gas or background gas atoms/molecules produce a momentary shift of the ion clock transition frequency and constitute one of the largest systematic effects in this type of clock. Here we report an initial measurement of the He pressure shift in Hg-201(+) and compare this to Hg-199(+).

Larigani, S. Taghavi↗

Extended Scene SH Wavefront Sensor Algorithm: Minimization of Scene Content Dependent Shift Estimation Errors

Adaptive Periodic-Correlation (APC) algorithm was developed for use in extended-scene Shack-Hartmann wavefront sensors. It provides high-accuracy even when the sub-images in a frame captured by a Shack-Hartmann camera are not only shifted but also distorted relative to each other. Recently we found that the shift-estimate error of the APC algorithm has a component that depends on the content of extended-scene. In this paper we assess the amount of that error and propose a method to minimize it.

Sidick, Erkin↗

A Doppler-Cancellation Technique for Determining the Altitude Dependence of Gravitational Red Shift in an Earth Satellite

A cancellation technique permits measurement of the frequency of a source moving relative to an observer without the obscuring effect of first-order Doppler shifts. The application of this method to a gravitational red shift experiment involving the use of an earth satellite containing a highly stable oscillator is described. The rapidity with which a measurement can be made permits the taking of data at various altitudes in a given elliptical orbit. Tropospheric and ionospheric effects upon the accuracy of results are estimated.

Badessa, R. S.↗

Preliminary Investigation of the Satellite Gravitational Red Shift Experiment

The work performed under this contract involved study, design, and construction of experimental equipment to perform a short-term measurement of the gravitational red shift. In the system designed, phase comparison techniques are employed so that the time interval required to obtain a single measurement for one altitude is of the order of one minute. An elliptical orbit was chosen to permit measurement of frequency shift as a function of altitude. One particularly attractive orbit is that having a 12-hour orbiting period (perigee, 270 miles, apogee 24,800 miles). This orbit, shown in Fig. 1, allows continuous measurements to be made over an 11-hour interval during which time the altitude is varying greatly. Measurements can not be made for the succeeding 14 hours. Since the variation of frequency difference with altitude is of greatest interest, a fixed offset or a slow drift between the oscillator on the ground and. the oscillator in the satellite will not invalidate the measurements.

Zacharias, J. R.↗

Proteomic Assessment of Fluid Shifts and Association with Visual Impairment and Intracranial Pressure in Twin Astronauts

BACKGROUND: Astronauts participating in long duration space missions are at an increased risk of physiological disruptions. The development of visual impairment and intracranial pressure (VIIP) syndrome is one of the leading health concerns for crew members on long-duration space missions; microgravity-induced fluid shifts and chronic elevated cabin CO2 may be contributing factors. By studying physiological and molecular changes in one identical twin during his 1-year ISS mission and his ground-based co-twin, this work extends a current NASA-funded investigation to assess space flight induced "Fluid Shifts" in association with the development of VIIP. This twin study uniquely integrates physiological and -omic signatures to further our understanding of the molecular mechanisms underlying space flight-induced VIIP. We are: (i) conducting longitudinal proteomic assessments of plasma to identify fluid regulation-related molecular pathways altered by long-term space flight; and (ii) integrating physiological and proteomic data with genomic data to understand the genomic mechanism by which these proteomic signatures are regulated. PURPOSE: We are exploring proteomic signatures and genomic mechanisms underlying space flight-induced VIIP symptoms with the future goal of developing early biomarkers to detect and monitor the progression of VIIP. This study is first to employ a male monozygous twin pair to systematically determine the impact of fluid distribution in microgravity, integrating a comprehensive set of structural and functional measures with proteomic, metabolomic and genomic data. This project has a broader impact on Earth-based clinical areas, such as traumatic brain injury-induced elevations of intracranial pressure, hydrocephalus, and glaucoma. HYPOTHESIS: We predict that the space-flown twin will experience a space flight-induced alteration in proteins and peptides related to fluid balance, fluid control and brain injury as compared to his pre-flight protein/peptide signatures. Conversely, the trajectory of these protein signatures will remain relatively constant in his ground based co-twin. METHODS: We are using proteomic and standard immunoelectrophoresis techniques to delineate the change in protein signatures throughout the course of a long duration space flight in relation to the development of VIIP. We are also applying a novel cell-based metaboloic organ system assay ("Organs on a Plate") to address how these circulating biomarkers affect physiological processes at the cellular and organ level which could result in VIIP symptoms. These molecular data will be correlated with physiological measures (eg. extra and intracellular fluid volume, vascular filling/flow patterns, MRI, and Optic Coherence Tomography. DISCUSSION: Pre- and in-flight data collection is in progress for the space-flown twin, and similar data have been obtained from the ground-based twin. Biosamples will be batch processed when received from ISS after the conclusion of the 1-year mission. Omic and Physiological measures from the twin astronauts will be compared to similar data being collected on twin subjects who participated in simulated microgravity study. bed rest study.

Rana, Brinda K.↗

Conflict Detection Performance Analysis for Function Allocation Using Time-Shifted Recorded Traffic Data

The performance of the conflict detection function in a separation assurance system is dependent on the content and quality of the data available to perform that function. Specifically, data quality and data content available to the conflict detection function have a direct impact on the accuracy of the prediction of an aircraft's future state or trajectory, which, in turn, impacts the ability to successfully anticipate potential losses of separation (detect future conflicts). Consequently, other separation assurance functions that rely on the conflict detection function - namely, conflict resolution - are prone to negative performance impacts. The many possible allocations and implementations of the conflict detection function between centralized and distributed systems drive the need to understand the key relationships that impact conflict detection performance, with respect to differences in data available. This paper presents the preliminary results of an analysis technique developed to investigate the impacts of data quality and data content on conflict detection performance. Flight track data recorded from a day of the National Airspace System is time-shifted to create conflicts not present in the un-shifted data. A methodology is used to smooth and filter the recorded data to eliminate sensor fusion noise, data drop-outs and other anomalies in the data. The metrics used to characterize conflict detection performance are presented and a set of preliminary results is discussed.

Guerreiro, Nelson M.↗