Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SERVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

AVTA Federal Fleet PEV Readiness Data Logging and Characterization Study for the National Park Service: Golden Gate National Recreation Area

Battelle Energy Alliance, LLC, managing and operating contractor for the U.S. Department of Energy's Idaho National Laboratory, is the lead laboratory for U.S. Department of Energy Advanced Vehicle Testing. Battelle Energy Alliance, LLC contracted with Intertek Testing Services, North America (ITSNA) to collect data on federal fleet operations as part of the Advanced Vehicle Testing Activity's Federal Fleet Vehicle Data Logging and Characterization study. The Advanced Vehicle Testing Activity study seeks to collect data to validate the utilization of advanced electric drive vehicle transportation. This report focuses on the Golden Gate National Recreation Area (GGNRA) fleet to identify daily operational characteristics of select vehicles and report findings on vehicle and mission characterizations to support the successful introduction of plug-in electric vehicles (PEVs) into the agencies' fleets. Individual observations of these selected vehicles provide the basis for recommendations related to electric vehicle adoption and whether a battery electric vehicle or plug-in hybrid electric vehicle (PHEV) (collectively PEVs) can fulfill the mission requirements. GGNRA identified 182 vehicles in its fleet, which are under the management of the U.S. General Services Administration. Fleet vehicle mission categories are defined in Section 4, and while the GGNRA vehicles conduct many different missions, only two (i.e., support and law enforcement missions) were selected by agency management to be part of this fleet evaluation. The selected vehicles included sedans, trucks, and sport-utility vehicles. This report will show that battery electric vehicles and/or PHEVs are capable of performing the required missions and providing an alternative vehicle for support vehicles and PHEVs provide the same for law enforcement, because each has a sufficient range for individual trips and time is available each day for charging to accommodate multiple trips per day. These charging events could occur at the vehicle home base, high-use work areas, or intermediately along routes that the vehicles frequently travel. Replacement of vehicles in the current fleet would result in significant reductions in the emission of greenhouse gases and petroleum use, while also reducing fuel costs. The San Francisco Bay Area is a leader in the adoption of PEVs in the United States. PEV charging stations, or more appropriately identified as electric vehicle supply equipment, located on the GGNRA facility would be a benefit for both GGNRA fleets and general public use. Fleet drivers and park visitors operating privately owned PEVs benefit by using the charging infrastructure. ITSNA recommends location analysis of the GGNRA site to identify the optimal placement of the electric vehicle supply equipment station. ITSNA recognizes the support of Idaho National Laboratory and ICF International for their efforts to initiate communication with the National Parks Service and GGNRA for participation in the study. ITSNA is pleased to provide this report and is encouraged by the high interest and support from the National Park Service and GGNRA personnel.

99 GENERAL AND MISCELLANEOUS↗

Safety Case for Service Contracts

Safety cases developed for the Facilities Management and Operations Center (FMOC) are based on the requirements in MN471021, Work Planning and Control Criteria for Safe Design and Operations. The FMOC performs maintenance activities in various locations at Sandia National Laboratories, New Mexico (SNL/NM). SNL/NM consists of more than 6,000,000 square feet of buildings, structures, and site infrastructure on approximately 13,000 acres of land. The FMOC performs approximately 7500 service contract work orders a year to assist with operations and maintenance at the SNL/NM site and facilities. As part of the continual improvement process, this Safety Case will be reviewed and updated, as needed, or at a minimum every three years. People tend to underestimate the probability of an accident if none have occurred previously or if the person performing the work is skilled, and they tend to trust each other’s competence. Human error within systems must be identified and considered. The FMOC uses failure mode analysis (FMA) to determine how a system might fail and cause accidents, as well as the amount and types of controls needed. The FMOC includes interconnected elements, such as people, environment, procedures, facilities, equipment, and the hazards identified in the work analysis. A daily pre-task plan is required prior to any work activity. Changes in work practices will be communicated clearly to all service contractors and personnel by way of contractor pre-task planning, activity-specific plans, contract amendments, and/or training. The FMOC has created a safe-by-design intent approach for service contract execution starting at the planning stage and extending through the execution phase. The Safety Program (see Figure 2) summarizes how the FMOC connects work analysis elements with service contracts.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

US NDC Modernization: Service Oriented Architecture Study Status

This report is a progress update on the USNDC Modernization Service Oriented Architecture (SOA) study describing results from Inception Iteration 1, which occurred between October 2012 and March 2013. The goals during this phase are 1) discovering components of the system that have potential service implementations, 2) identifying applicable SOA patterns for data access, service interfaces, and service orchestration/choreography, and 3) understanding performance tradeoffs for various SOA patterns

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

US NDC Modernization: Service Oriented Architecture Proof of Concept

This report is a progress update on the US NDC Modernization Service Oriented Architecture (SOA) study describing results from a proof of concept project completed from May through September 2013. Goals for this proof of concept are 1) gain experience configuring, using, and running an Enterprise Service Bus (ESB), 2) understand the implications of wrapping existing software in standardized interfaces for use as web services, and 3) gather performance metrics for a notional seismic event monitoring pipeline implemented using services with various data access and communication patterns. The proof of concept is a follow on to a previous SOA performance study. Work was performed by four undergraduate summer student interns under the guidance of Sandia staff.

97 MATHEMATICS AND COMPUTING↗

Economic and Physical Linkages of the Information and Communication Technology (ICT) Service Industry to Key Industries of the Economy: An Ad Hoc Report

This report examines the information and communications technology (ICT) services industry in response to an inquiry by the Department of Energy’s (DOE’s) Office of Energy Policy and Systems Analysis. The report answers several key questions: •How has the reliance on ICT services evolved in recent years for key infrastructure services such as air travel, freight transport, electricity and natural gas distribution, financial services, and critical health care, and for the household sector? •What ICT industry trends explain continued strong linkage to and reliance upon ICT? •What is the ICT industry’s reliance on grid-supplied power, uninterruptible power supplies, emergency generators and back-up energy storage technologies? •What are the observed direct effects of ICT disruptions induced by electrical system failures in recent history and how resilient are the components of the ICT industry?

99 GENERAL AND MISCELLANEOUS↗

Grid-Scale Energy Storage Demonstration of Ancillary Services Using the UltraBattery Technology

The collaboration described in this document is being done as part of a cooperative research agreement under the Department of Energy’s Smart Grid Demonstration Program. This document represents the Final Technical Performance Report, from July 2012 through April 2015, for the East Penn Manufacturing Smart Grid Program demonstration project. This Smart Grid Demonstration project demonstrates Distributed Energy Storage for Grid Support, in particular the economic and technical viability of a grid-scale, advanced energy storage system using UltraBattery ® technology for frequency regulation ancillary services and demand management services. This project entailed the construction of a dedicated facility on the East Penn campus in Lyon Station, PA that is being used as a working demonstration to provide regulation ancillary services to PJM and demand management services to Metropolitan Edison (Met-Ed).

25 ENERGY STORAGE↗

Integrated IO Services for Trilinos Data Structures

The Trilinos Project is an effort to develop algorithms and enabling technologies within an object- oriented software framework for the solution of large-scale, complex multi-physics engineering and scientific problems. A unique design feature of Trilinos is its focus on packages. While the abstractions make it easy to incorporate advanced processing and data manipulation tools, it is not always obvious how to take advantage of these features. The trios package incorporated two years ago offers general data management services, but has yet to offer integrated support for core Trilinos data structures, such as those offered in the Tpetra package. An initial attempt to incorporate native Trilinos data structure support into trios services revealed the complexity, from a non-mathematician's perspective, of using Trilinos. This project sought to understand the complexities and potential barriers not just for non-mathematicians that want to contribute to or use Trilinos, but potentially for new mathematically-inclined users as well that may want to offer services to support users. This report documents the challenges for trios to offer some simple data manipulation required as a precursor to any direct data services integration and makes recommendations for clarifying the performance implications and general approach to use.

97 MATHEMATICS AND COMPUTING↗

SNL API-653 In-Service Tank Inspection and Evaluation Tank ID: 981-A2-T0 (West)

An API Standard 653 In-Service inspection was completed on Tank 981-A2-T0 (West) located at the Sandia National Laboratories TAIV tank farm in Albuquerque, NM on September 22, 2015. The inspection was completed to collect data to evaluate the mechanical integrity and fitness for continued service of the tank. No indication or records of any previous inspection were identified for this tank. The inspection and engineering evaluation were completed using API-653, 5 th Edition and conservative engineering practices. The tank was not removed from service, so an internal inspection could not be completed. The tank was also fully insulated. The insulation was removed in specified areas of the tank shell and tank chime to accommodate an acoustic emission scan of the tank and an ultrasonic thickness evaluation of portions of the tank. The acoustic emission scan resulted in a grade of B / I - II indicating an overall TANKPAC grade B and composite grade II indicating minor active damage with highly concentrated sources related to corrosion found in the southeast and west side section of the tank. Eight Potential Localized Damage sources were found mainly in the west side (re-test in 2 years). The tank chime could not be inspected due to the configuration of the insulation welded angle support. An ultrasonic guided bulk wave inspection was completed on the tank shell to assess the lower shell section. At the time of the inspection the limited data collected showed minimal material loss from the shell at the thickness monitoring locations, however, visual inspection and pit depth gauge measurements showed > 3/16” inch pitting and significant general external surface corrosion on the shell at the shell to floor joint. This corrosion is caused by the insulation sheeting support welded angle iron trapping moisture and dirt against the tank shell. This tank should be removed from service, internally inspected, and repaired. Ultrasonic thickness measurement locations were established on this tank and the data is included in this report. The limited data collected indicated minimal material loss at these locations, with the only noted corrosion occurring on the tank shell to floor joint as noted above. An API-653 Annex B Evaluation of Tank Bottom Settlement was completed and the results are included in this report. No significant settlement issues were identified.

42 ENGINEERING↗

FPGAs as a Service to Accelerate Machine Learning Inference [PowerPoint]

Large-scale particle physics experiments face challenging demands for high-throughput computing resources both now and in the future. New heterogeneous computing paradigms on dedicated hardware with increased parallelization, such as Field Programmable Gate Arrays (FPGAs), offer exciting solutions with large potential gains. The growing applications of machine learning algorithms in particle physics for simulation, reconstruction, and analysis are naturally deployed on such platforms. We demonstrate that the acceleration of machine learning inference as a web service represents a heterogeneous computing solution for particle physics experiments that requires minimal modification to the current computing model. As examples, we retrain the ResNet-50 convolutional neural network to demonstrate state-of-the-art performance for top quark jet tagging at the LHC, and apply a ResNet-50 model with transfer learning for neutrino event classification. Using Project Brainwave b y Microsoft to accelerate the ResNet-50 image classification model, we achieve average inference times of 60 (10) milliseconds with our experimental physics software framework using Brainwave as a cloud (edge or on-premises) service, representing an improvement by a factor of approximately 30 (175) in model inference latency over traditional CPU inference in current experimental hardware. A single FPGA service accessed by many CPUs achieves a throughput of 600--700 inferences per second using an image batch of one, comparable to large batch-size GPU throughput and significantly better than small batch-size GPU throughput. Deployed as an edge or cloud service for the particle physics computing model, coprocessor accelerators can have a higher duty cycle and are potentially much more cost-effective.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

HR-ITS Customer Service Agreement (FY 2020)

Document intended for training purposes. The purpose of this Customer Service Agreement (CSA) is to formalize the agreement between HR-ITS and a customer who requires services. This agreement describes the specific services to be provided by HR-ITS and the costs that the customer agrees to pay for such services.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Enterprise Credentialing Service Statement of Work (SOW)

The scope of this project includes providing professional services in support of the development and deployment of an Enterprise Credentialing Service for the Department of Energy (DOE) National Nuclear Security Administration (NNSA), which will be used for issuing and managing credentials used for authentication, digital signature, and encryption functions by users, applications, and devices in a closed computing environment. The Seller shall provide subject matter expertise for the design and deployment of the technologies and processes that comprise the Enterprise Credentialing Service, which will include a public key infrastructure (PKI) and a credential management system (CMS) that issues and manages PKI-based smartcard credentials. The Enterprise Credentialing Service will support approximately 17,000 users at 15 DOE NNSA sites and laboratories located across the continental United States.

97 MATHEMATICS AND COMPUTING↗

DER as a service-ecoLong and VOLTTRON (Abstract)

The project goal is to commercialize the VOLTTRON-hosted “DER as a Service” (DaaS) application and make it an “out-of-the-box” solution for ecoLong to use as a secure residential energy management system that allows 1.) distributed energy resources (DERs) to participate in wholesale markets and provide services to the grid and 2.) intelligently control the energy in the residential buildings to the desired level while maintaining occupancy comfort. The product will be field deployed onto multiple Solar Liberty sites in New York state to demonstrate wide-scale participation of DERs in wholesale markets to provide services to the grid and validate the effectiveness of the solution. The integrated management of DERs and buildings increases the penetration of solar resources by managing its variability, providing grid services, and solving the evening ramping challenges. Ultimately, the DaaS platform will make buildings and DERs smarter by unlocking grid-interactive efficient buildings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Computational fluid dynamic modeling to determine the indoor environment of an electron-ion collider service building

The design for the Electron-Ion Collider (EIC) calls for several service buildings that house various power supplies and control electronics for the collider ring itself. In order to operate within specified conditions, the ambient air entering the power supplies needs to be within a certain temperature range while dissipating the heat from losses. Proper cooling is therefore a necessity in the service buildings to ensure that every aspect of the EIC works as intended. Since the EIC is in the design stage, we are evaluating the indoor environment of the service building using the current design specifications. We have researched multiple forms of literature and performed the necessary calculations to compile a list of boundary conditions that accurately represent the situation at hand. We are using computational fluid dynamics modeling to solve the conservation equations for mass, momentum, and energy (Navier-Stokes). This allows us to perform a finite element analysis which will give us the flow distribution in the room as well as temperature profiles throughout the building. We have obtained a simulation result giving us the temperature profiles for the building and it shows that the placement of the racks and supply vents are essential to obtaining an even temperature distribution. This model will provide a basis for design decisions which will affect the overall cooling of the service building without extending the schedule and avoiding a costly reworking of the cooling system.

43 PARTICLE ACCELERATORS↗

Motivation and Design of the OCPP Security Service

Pacific Northwest National Laboratory is conducting in-depth research aimed at exploring how zero trust security principles can be effectively applied to electric vehicle charging infrastructure. This investigation seeks to enhance the resilience and reliability of these systems against cyber threats, ensuring secure and uninterrupted access to charging services for electric vehicle users and electric supply. Zero trust is a security concept centered on the belief that system operators should not automatically trust users or systems based on their location, whether inside or outside the organization, but instead must verify everything trying to connect to their systems before granting access. A key aspect of the project is to demonstrate and validate zero trust approaches targeted to electric vehicle (EV) charging infrastructure. It has been observed that both open-source and commercial solutions often overlook the specific protocols employed in managing EV charging stations and proceeded with a general, protocol-agnostic approach. While these strategies effectively block non-authorized routes to the charging infrastructure, they do not tackle the situations where attackers may exploit legitimate access channels, such as the inattentive operator model posited by the Idaho National Laboratory. To address this gap, this paper proposes and discusses a new security service targeted to the Open Charge Point Protocol (OCPP), which is the de facto protocol for the management of charging stations and serves a critical role in the broader adoption of electric vehicles. The design and architecture of the proposed OCPP security service are discussed in detail, outlining how it aims to safeguard charging station management system (CSMS) functions. The service is particularly important in scenarios where the charging station operator (CSO), responsible for the maintenance and operation of charging stations, and the charging network provider (CNP), which manages the charging network's accessibility and billing, are separate entities. This distinction is crucial because CSOs and CNPs often have different priorities, objectives, and operational responsibilities, which may not always align perfectly. For instance, a CSO might prioritize uptime and customer satisfaction, while a CNP might focus on maximizing revenue and network utilization. Such misalignment can create security vulnerabilities, as each entity might implement different policies and standards, potentially leaving gaps in the overall security posture.

33 ADVANCED PROPULSION SYSTEMS↗

Microstructure and in-service degradation of baffle former bolts – in-core components of light water reactors

This report presents a microstructure evaluation of the baffle former bolt, a commercial pressurized water reactor component. Using SEM, EDS, and EBSD analysis the material was identified as AISI 316 steel with an annealed austenite microstructure. Findings include abnormal grain growth in a fraction of the grains and the absence of retained ferrite. Notable observations include an overlapping of pre- and post-irradiation deformation, including defect-free channel formation as an active deformation mechanism in the near-surface layer of BFB. Specimen surfaces, exposed to high-temperature, high-pressure water, exhibited signs of in-service corrosion degradation. EBSD and EDS analyses highlighted intergranular corrosion, possible grain boundary oxidation with depths less than 3 µm, and, unexpectedly, short cracks filled with Cr-rich oxides measuring around 5-6 µm. The presence of defect-free channels from EBSD data suggests episodes of high mechanical stresses during service. The specimens provide a potentially unique insight into the in-service degradation of NPP components, strain localization, and crack initiation processes. An intact corrosion layer reveals a complex component's in-service history. Further research is underway for a detailed analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fitness for Service Assessment of a Corroded Heat Exchanger

Fermilab s Main Injector Accelerator has used shell & tube heat exchangers to cool various beamline components since its construction in the late 1990s. Many of the heat exchangers still around today are original to the machine. Untreated pond water has been used to exchange heat with the Low Conductivity Water. Throughout the lifetime of Fermilab s heat exchangers, they have undergone significant material degradation in the carbon steel end channels due to corrosion. Wall thickness measurements (per API 510) of each heat exchanger were used to generate a 3D model of the corroded surfaces. In order to continue their safe and reliable operation, ASME FFS-1/API 579 (Fitness-For-Service) was implemented to address their integrity. The assessments consisted of finite element analysis techniques outlined in ASME Section VIII Div. 2 (design by analysis methods for pressure vessels), in accordance with the requirements of ASME FFS-1 Part 4: General Metal Loss, Part 5: Local Metal Loss, and Part 9: Crack Like Flaws. The assessments concluded that each heat exchanger is coined Fit For Service . The Fitness-For-Service standard offers a unique opportunity to facilities and institutions within the DOE National Lab complex to properly and safely assess the integrity of aging equipment necessary to conduct science and research. This poster demonstrates the assessment process and techniques used to determine the heat exchangers are fit for service.

Humenik, Alex [Fermilab]↗

Potential of Data Center Controls in Grid Services

The rapid proliferation of large data centers brings both challenges and opportunities for grid reliability. The data center resources and their potential flexibility have the potential to contribute resources to grid operations. Through capabilities like energy shifting and resource coordination, data centers can help reduce their net demand on the transmission network, as well as provide additional grid services to support reliable operation on the grid. While transient and long-term grid planning and operations are the scenarios that draw most attention, the quasi-steady state timeseries (QSTS) operation of data centers and grid bring interesting scenarios that can help evaluate the data center controls to aid grid services. This work is focused on modeling data centers for QSTS applications – incorporating the AI data center load profiles and building on the PNNL digital twin model for the thermal management loads to enable simulation studies to reveal the impact of data center controls on grid performance. This includes the integration of a QSTS battery and natural gas generator model to incorporate local resource impacts to the system. The simulation study is performed with a modified IEEE 24-Bus transmission system. Scenarios are focused on evaluating the data center load impacts on the transmission system and leveraging both data center and local generation controls to mitigate those impacts and provide additional grid services. The data center controls revealed the ability to contribute to two main kinds of grid services: preventing congestion on a weak grid by coordinating the data center resources with the collocated BESS and onsite generation; and the ability to help the grid operations during stressed times of operation like during a contingency. Leveraging these and other capabilities has the potential to help data centers become grid responsive assets, aiding in both their integration into the power system and grid reliability.

power grid simulation↗

Estimated Value of Service Reliability for Electric Utility Customers in the United States

Information on the value of reliable electricity service can be used to assess the economic efficiency of investments in generation, transmission and distribution systems, to strategically target investments to customer segments that receive the most benefit from system improvements, and to numerically quantify the risk associated with different operating, planning and investment strategies. This paper summarizes research designed to provide estimates of the value of service reliability for electricity customers in the US. These estimates were obtained by analyzing the results from 28 customer value of service reliability studies conducted by 10 major US electric utilities over the 16 year period from 1989 to 2005. Because these studies used nearly identical interruption cost estimation or willingness-to-pay/accept methods it was possible to integrate their results into a single meta-database describing the value of electric service reliability observed in all of them. Once the datasets from the various studies were combined, a two-part regression model was used to estimate customer damage functions that can be generally applied to calculate customer interruption costs per event by season, time of day, day of week, and geographical regions within the US for industrial, commercial, and residential customers. Estimated interruption costs for different types of customers and of different duration are provided. Finally, additional research and development designed to expand the usefulness of this powerful database and analysis are suggested.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗