Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

A transport-based model of material trends in nonproportionality of scintillators

Electron-hole pairs created by the passage of a high-energy electron in a scintillator radiation detector find themselves in a very high radial concentration gradient of the primary electron track. Since nonlinear quenching that is generally regarded to be at the root of nonproportional response depends on the fourth or sixth power of the track radius in a cylindrical track model, radial diffusion of charge carriers and excitons on the {approx}10 picosecond duration typical of nonlinear quenching can compete with and thereby modify that quenching. We use a numerical model of transport and nonlinear quenching to examine trends affecting local light yield versus excitation density as a function of charge carrier and exciton diffusion coefficients. Four trends are found: (1) nonlinear quenching associated with the universal 'roll-off' of local light yield versus dE/dx is a function of the lesser of mobilities {mu}{sub e} and {mu}{sub h} or of D{sub EXC} as appropriate, spanning a broad range of scintillators and semiconductor detectors; (2) when {mu}{sub e{approx_equal}{mu}h}, excitons dominate free carriers in transport, the corresponding reduction of scattering by charged defects and optical phonons increases diffusion out of the track in competition with nonlinear quenching, and a rise in proportionality is expected; (3) when {mu}{sub h} << {mu}{sub e} as in halide scintillators with hole self-trapping, the branching between free carriers and excitons varies strongly along the track, leading to a 'hump' in local light yield versus dE/dx; (4) anisotropic mobility can promote charge separation along orthogonal axes and leads to a characteristic shift of the 'hump' in halide local light yield. Trends 1 and 2 have been combined in a quantitative model of nonlinear local light yield which is predictive of empirical nonproportionality for a wide range of oxide and semiconductor radiation detector materials where band mass or mobility data are the determinative material parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of nonproportionality in the light yield of inorganic scintillators

Using a phenomenological approach, the light yield is derived for inorganic scintillators as a function of the rates of linear, bimolecular, and Auger processes occurring in the electron track initiated by an x ray or a {gamma}-ray photon. A relation between the track length and incident energy is also derived. It is found that the nonproportionality in the light yield can be eliminated if either nonlinear processes of interaction among the excited electrons, holes, and excitons can be eliminated from occurring or the high density situation can be relieved by diffusion of carriers from the track at a faster rate than the rate of activation of nonlinear processes. The influence of the track length and radius on the yield nonproportionality is discussed in view of the known experimental results. Inventing new inorganic scintillating materials with high carrier mobility can lead to a class of proportional inorganic scintillators. Results agree qualitatively with experimental results for the dependence of light yield on the incident energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation of rare earth doped fluoride nanoparticles

The scintillation response of rare earth (RE) doped core/undoped (multi-)shell fluoride nanoparticles was investigated under x-ray and alpha particle irradiation. A significant enhancement of the scintillation response was observed with increasing shells due: (i) to the passivation of surface quenching defects together with the activation of the REs on the surface of the core nanoparticle after the growth of a shell, and (ii) to the increase of the volume of the nanoparticles. These results are expected to reflect a general aspect of the scintillation process in nanoparticles, and to impact radiation sensing technologies that make use of nanoparticles.

36 MATERIALS SCIENCE↗

Active Inspection of Nuclear Materials Using {sup 4}He Scintillation Detectors

The detection of fissionable materials by neutron and high-energy photon active interrogation methods is explored using {sup 4}He scintillation detectors to search for prompt and delayed neutron signature. The low electron density of {sup 4}He in addition to its pulse shape discrimination capability allows strong rejection of gamma radiation. For the detection of the prompt neutron signatures, this capability is important as the signal produced by induced fission is accompanied by intense gamma radiation. The nanosecond time resolution of {sup 4}He scintillation detectors can be used for time-of-flight measurements aimed at determining the energy of the emitted neutrons. For delayed neutron detection, the insensitivity to the low energy neutrons present from non-signal reactions is inherent. Unlike detectors requiring a moderator, this technology can easily be collimated to reduce sensitivity to neutrons from outside the field of interest. The performance of the detectors for these applications is studied using GEANT4 computer modeling, based on measured detector parameters. A comparison is made with technologies typically used for these applications, i.e. heavily shielded organic scintillators for prompt neutron detection and Cd-lined {sup 3}He neutron detectors for the detection of delayed neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Double {beta} experiments with the help of scintillation and HPGe detectors at Gran Sasso

A search for double beta decay of {sup 64,70}Zn, {sup 180,186}W was carried out by using low background ZnWO{sub 4} crystal scintillators, while a CeCl{sub 3} scintillation detector was applied to investigate 2{beta} processes in {sup 136,138,142}Ce. A search for 2{beta} decay of {sup 96,104}Ru, {sup 156,158}Dy, {sup 190,198}Pt and study of 2{nu}2{beta} decay of {sup 100}Mo to the first excited 0{sup +} level of {sup 100}Ru were realized by ultra-low background HPGe {gamma} spectrometry. Moreover, CdWO{sub 4} crystal scintillators from enriched {sup 106}Cd and {sup 116}Cd isotopes were developed to search for 2{beta} decay of {sup 106}Cd and {sup 116}Cd. Finally, experiments aimed to investigate {sup 96,104}Ru and {sup 116}Cd are in progress and a new phase of the experiment to search for 2{beta} processes in {sup 106}Cd is in preparation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the muon-induced neutron yield in liquid scintillator and stainless steel at LNGS with the LVD experiment

We describe the measurement of the muon-induced neutron yield in liquid scintillator and stainless steel (SS) at the Gran Sasso National Laboratory (LNGS), with the LVD experiment. The Large Volume Detector (LVD) is located in Hall A of the LNGS and is made of 1000 t of liquid scintillator and 1000 t of SS. Using an independent measurement to evaluate the background and with the support of a full Monte Carlo simulation based on Geant4, we measured a neutron yield of (2.9±0.6)×10{sup −4} and (1.5±0.3)×10{sup −3} in liquid scintillator and in stainless steel, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

R and D of crystal scintillators from enriched isotopes for high sensitivity double β decay experiments

Experiments to search for neutrinoless double beta decay enters to a new phase when a sensitivity on the level of T{sub 1/2}∼10{sup 26}−10{sup 28} yr is required. Scintillating low temperature detectors possess important properties required for high-sensitivity double beta decay experiments: presence of elements of interest, high energy resolution and detection efficiency, low level of background thanks to excellent particle discrimination ability. High concentration of isotope of interest and as low as possible radioactive contamination are important requirements to crystal scintillators. Other crucial issues are maximal output of detectors and minimal loss of enriched materials. Prospects of several scintillation materials, enriched in isotopes promising for double beta decay experiments, are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of the scintillator-based probe for fast-ion losses in the HL-2A tokamak

A new scintillator-based lost fast-ion probe (SLIP) has been developed and operated in the HL-2A tokamak [L. W. Yan, X. R. Duan, X. T. Ding, J. Q. Dong, Q. W. Yang, Yi Liu, X. L. Zou, D. Q. Liu, W. M. Xuan, L. Y. Chen, J. Rao, X. M. Song, Y. Huang, W. C. Mao, Q. M. Wang, Q. Li, Z. Cao, B. Li, J. Y. Cao, G. J. Lei, J. H. Zhang, X. D. Li, W. Chen, J. Chen, C. H. Cui, Z. Y. Cui, Z. C. Deng, Y. B. Dong, B. B. Feng, Q. D. Gao, X. Y. Han, W. Y. Hong, M. Huang, X. Q. Ji, Z. H. Kang, D. F. Kong, T. Lan, G. S. Li, H. J. Li, Qing Li, W. Li, Y. G. Li, A. D. Liu, Z. T. Liu, C. W. Luo, X. H. Mao, Y. D. Pan, J. F. Peng, Z. B. Shi, S. D. Song, X. Y. Song, H. J. Sun, A. K. Wang, M. X. Wang, Y. Q. Wang, W. W. Xiao, Y. F. Xie, L. H. Yao, D. L. Yu, B. S. Yuan, K. J. Zhao, G. W. Zhong, J. Zhou, J. C. Yan, C. X. Yu, C. H. Pan, Y. Liu, and the HL-2A Team , Nucl. Fusion 51, 094016 (2011)] to measure the losses of neutral beam ions. The design of the probe is based on the concept of the α-particle detectors on Tokamak Fusion Test Reactor (TFTR) using scintillator plates. The probe is capable of traveling across an equatorial plane port and sweeping the aperture angle rotationally with respect to the axis of the probe shaft by two step motors, in order to optimize the radial position and the collimator angle. The energy and the pitch angle of the lost fast ions can be simultaneously measured if the two-dimensional image of scintillation light intensity due to the impact of the lost fast ions is detected. Measurements of the fast-ion losses using the probe have been performed during HL-2A neutral beam injection discharges. The clear experimental evidence of enhanced losses of beam ions during disruptions has been obtained by means of the SLIP system. A detailed description of the probe system and the first experimental results are reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-energy X-ray detection by hafnium-doped organic-inorganic hybrid scintillators prepared by sol-gel method

With the aim of enhancing the efficiency with which plastic scintillators detect high-energy X-rays, hafnium-doped organic-inorganic hybrid scintillators were fabricated via a sol-gel method. Transmission electron microscopy of sampled material reveals the presence of Hf{sub x}Si{sub 1−x}O{sub 2} nanoparticles, dispersed in a polymer matrix that constitutes the active material of the X-ray detector. With Hf{sub x}Si{sub 1−x}O{sub 2} nanoparticles incorporated in the polymer matrix, the absorption edge and the luminescence wavelength is shifted, which we attribute to Mie scattering. The detection efficiency for 67.4-keV X-rays in a 0.6-mm-thick piece of this material is two times better than the same thickness of a commercial plastic scintillator-NE142.

36 MATERIALS SCIENCE↗

Monte Carlo simulation of the data acquisition chain of scintillation detectors

The good performance of a detector can be strongly affected by the instrumentation used to acquire the data. The possibility of anticipating how the acquisition chain will affect the signal can help in finding the best solution among different set-ups. In this work we developed a Monte Carlo code that aims to simulate the effect of the various components of a digital Data Acquisition system (DAQ) applied to scintillation detectors. The components included in the model are: the scintillator, the photomultiplier tube (PMT), the signal cable and the digitizer. We benchmarked the code against real data acquired with a NE213 scintillator, comparing simulated and real signal pulses induced by gamma-ray interaction. Then we studied the dependence of the energy resolution of a pulse height spectrum (PHS) on the sampling frequency and the bit resolution of the digitizer. We found that exceeding some values of the sampling frequency and the bit resolution improves only marginally the performance of the system. The method can be applied for the study of various detector systems relevant for nuclear techniques, such as in fusion diagnostics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neutron emission measurement at the HL-2A tokamak device with a liquid scintillation detector

Neutron emission measurement at the HL-2A tokamak device with a liquid scintillation detector is described. The detector was placed at a location with little structure material in the field of view, and equipped with a gain monitoring system which could provide the possibility to evaluate the gain variation as well as to correct for the detector response. Time trace of the neutron emissivity was obtained and it was consistent with the result of a standard {sup 235}U fission chamber. During the plasma discharge the neutron yield could vary by about four orders of magnitude and the fluctuation of the detector gain was up to about 6%. Pulse height spectrum of the liquid scintillation detector was constructed and corrected with the aid of the gain monitoring system, and the correction was found to be essential for the assessment of the neutron energy spectrum. This successful measurement offered experience and confidence for the application of liquid scintillation detectors in the upcoming neutron camera system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing a fast-response, low-afterglow liquid scintillator for neutron time-of-flight diagnostics in fast ignition experiments

The characteristics of oxygen-enriched liquid scintillators with very low afterglow are investigated and optimized for application to a single-hit neutron spectrometer for fast ignition experiments. It is found that 1,2,4-trimethylbenzene has better characteristics as a liquid scintillator solvent than the conventional solvent, p-xylene. In addition, a benzophenon-doped BBQ liquid scintillator is shown to demonstrate very rapid time response, and therefore has potential for further use in neutron diagnostics with fast time resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System for measuring temporal profiles of scintillation at high and different linear energy transfers by using pulsed ion beams

We have developed a system for measuring the temporal profiles of scintillation at high linear energy transfer (LET) by using pulsed ion beams from a cyclotron. The half width at half maximum time resolution was estimated to be 1.5–2.2 ns, which we attributed mainly to the duration of the pulsed ion beam and timing jitter between the trigger signal and the arrival of the ion pulse. The temporal profiles of scintillation of BaF{sub 2} at different LETs were successfully observed. These results indicate that the proposed system is a powerful tool for analyzing the LET effects in temporal profiles of scintillation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New scintillator materials for future and present facilities

In the recent years LaBr3:Ce crystals started a new generation of high performing scintillator detectors. In fact, a large number of different, new and promising scintillators are now becoming commercially available, as for example CeBr{sub 3}, CLYC, SrI{sub 2}. Some others, like GYGAG:Ce, CLLB, CLLC, will be available in the near future. The CLYC crystal enriched with {sup 6}Li provides extremely high efficiency for thermal neutron identification and detection with performances comparable to {sup 3}He tubes. The CLYC enriched with {sup 7}Li can provide the direct measurement of the neutron kinetic energy from the energy pulse signal. The most recent R and D activity shows that ‘co-doping’ technique has the effect to improve the crystal proportionality and the mechanical properties thus significantly increasing the reliability and energy resolution of LaBr{sub 3};Ce and CeBr{sub 3} scintillators. Such a new generation of detectors can be the backbone for the detectors array of the future accelerator facilities as for example ELI-NP which will provide very intense high-energy γ-ray beam with very low bandwidth.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of neutron detection utilizing open cell foam and noble gas scintillation

We present results demonstrating neutron detection via a closely spaced converter structure coupled to low pressure noble gas scintillation instrumented by a single photo-multiplier tube (PMT). The converter is dispersed throughout the gas volume using a reticulated vitreous carbon foam coated with boron carbide (B{sub 4}C). A calibrated cold neutron beam is used to measure the neutron detection properties, using a thin film of enriched {sup 10}B as a reference standard. Monte Carlo computations of the ion energy deposition are discussed, including treatment of the foam random network. Results from this study indicate that the foam shadows a significant portion of the scintillation light from the PMT. The high scintillation yield of Xe appears to overcome the light loss, facilitating neutron detection and presenting interesting opportunities for neutron detector design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of the scintillation mechanism in a pressurized {sup 4}He fast neutron detector using pulse shape fitting

An empirical investigation of the scintillation mechanism in a pressurized {sup 4}He gas fast neutron detector was conducted using pulse shape fitting. Scintillation signals from neutron interactions were measured and averaged to produce a single generic neutron pulse shape from both a {sup 252}Cf spontaneous fission source and a (d,d) neutron generator. An expression for light output over time was then developed by treating the decay of helium excited states in the same manner as the decay of radioactive isotopes. This pulse shape expression was fitted to the measured neutron pulse shape using a least-squares optimization algorithm, allowing an empirical analysis of the mechanism of scintillation inside the {sup 4}He detector. A further understanding of this mechanism in the {sup 4}He detector will advance the use of this system as a neutron spectrometer. For {sup 252}Cf neutrons, the triplet and singlet time constants were found to be 970 ns and 686 ns, respectively. For neutrons from the (d,d) generator, the time constants were found to be 884 ns and 636 ns. Differences were noted in the magnitude of these parameters compared to previously published data, however the general relationships were noted to be the same and checked with expected trends from theory. Of the excited helium states produced from a {sup 252}Cf neutron interaction, 76% were found to be born as triplet states, similar to the result from the neutron generator of 71%. The two sources yielded similar pulse shapes despite having very different neutron energy spectra, validating the robustness of the fits across various neutron energies.

36 MATERIALS SCIENCE↗

Studies of scintillation properties of CaMoO{sub 4} at millikelvin temperatures

Application of CaMoO{sub 4} as a scintillation target in cryogenic rare event searches relies on the understanding of scintillation properties of the material at the temperatures at which these detectors operate. We devised and implemented a detection module with a low-temperature photomultiplier from Hamamatsu (model R8520-06) powered by a Cockcroft-Walton generator. The detector module containing the CaMoO{sub 4} crystal was placed in a {sup 3}He/{sup 4}He dilution refrigerator and used to measure scintillation characteristics of CaMoO{sub 4} in the millikelvin temperature range. At the lowest temperature achieved, the energy resolution of CaMoO{sub 4} for 122 keV γ from a {sup 57}Co source is found to be 30%, and the fast and slow decay constants are 40.6 ± 0.8 μs and 3410 ± 50 μs, respectively. The temperature variation of the CaMoO{sub 4} decay kinetics is discussed in terms of a three-level model of the emission center.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A neutron scintillator based on transparent nanocrystalline CaF{sub 2}:Eu glass ceramic

There are no efficient Eu{sup 2+} doped glass neutron scintillators reported due to low doping concentrations of Eu{sup 2+} and the amorphous nature of the glass matrix. In this work, an efficient CaF{sub 2}:Eu glass ceramic neutron scintillator was prepared by forming CaF{sub 2}:Eu nanocrystals in a {sup 6}Li-containing glass matrix. Through appropriate thermal treatments, the scintillation light yield of the transparent glass ceramic was increased by a factor of at least 46 compared to the as-cast amorphous glass. This improvement was attributed to more efficient energy transfer from the CaF{sub 2} crystals to the Eu{sup 2+} emitting centers. Further light yield improvement is expected if the refractive index of the glass matrix can be matched to the CaF{sub 2} crystal.

36 MATERIALS SCIENCE↗