Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Application of the Rossi-alpha method to simulations of HEU and organic scintillators

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook contains thousands of high-quality benchmark measurements that include detailed descriptions of experiment designs and exhaustive accounting of uncertainties. These benchmarks are used extensively by the criticality safety and nuclear data communities. A subcritical benchmark involving bare, highly enriched uranium (HEU) has yet to be accepted to the handbook. The Measurement of Uranium Subcritical and Critical (MUSiC) was proposed to address this gap. MUSiC will be performed at the National Criticality Experiments Research Center (NCERC) and will leverage bare HEU hemisphere shells that can be assembled in a variety of configurations. The measurement has the following key benefits: it will be the first set of fast, subcritical measurements of HEU to be submitted to ICSBEP; ten configurations will be measured spanning from nearly no multiplication to critical (e.g., it is a measurement of similar systems with different re activities); measurements of an all-HEU system will be of value for nuclear data validation, providing results that assist in determining biases in both measurements and simulations. A variety of detector systems will be used including a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (#8960;) × 7.59 cm 3He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), and an array of eight 5.08 cm (#8960;) × 5.08 cm EJ-309 organic scintillator detectors. The focus of this work is the simulation of the subcritical MUSiC configurations including the EJ-309 detectors and the application of the Rossi-α method. The EJ-309 organic scintillator detector array is a new detection system that will be deployed at NCERC. Organic scintillators are ideal for measurements of fast, subcritical systems due to their short time response on the order of nanoseconds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LAO Scintillator Test

Presentation describes project to examine edge measurements of three scintillators (3 mm tiled LYSO, 10 mm tiled LYSO, 600 μm CsI), with a goal of beginning systematic examination of scintillator response and using new x-ray source to help determine low-energy scintillator response with high precision.

47 OTHER INSTRUMENTATION↗

Design and implementation of the new scintillation light detection system of ICARUS T600

ICARUS T600 is the far detector of the Short Baseline Neutrino program at Fermilab (U.S.A.), which foresees three Liquid Argon Time Projection Chambers along the Booster Neutrino Beam line to search for LSND-like sterile neutrino signal. The T600 detector underwent a significant overhauling process at CERN, introducing new technological developments while maintaining the already achieved performances. The realization of a new liquid argon scintillation light detection system is a primary task of the detector overhaul. As the detector will be subject to a huge flux of cosmic rays, the light detection system should allow the 3D reconstruction of events contributing to the identification of neutrino interactions in the beam spill gate. The design and implementation of the new scintillation light detection system of ICARUS T600 is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of scintillation light collection, production and propagation in a 4 tonne dual-phase LArTPC

The 3×1×1 m3 demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities. The performance of the photon detection system, composed of five PMTs, are discussed. The collected scintillation and electroluminescence light created by passing particles has been studied in various detector conditions. In particular, the scintillation light production and propagation processes have been analyzed and compared to simulations, improving the understanding of some liquid argon properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Manufacturing and characterization of a boron-loaded fast-cured plastic organic scintillator

A novel fast-cured, boron-loaded, plastic organic scintillator was developed and characterized. A diisopropylnaphthalene-containing scintillator was manufactured in minutes with the addition of two commercially available fast-curing monomers, isobornyl acrylate (IBOA) and 1,6-Hexanediol dimethacrylate (HDDMA). Further, the light yield of the device was measured to be approximately 70% relative to a similarly sized, but several-year-aged, EJ-276 detector. Using a coincidence capture technique, the neutron capture light output was found to be 87.7 ± 4.2 keVee, which was 1.47 ± 0.07 greater than the light output from a 59.5 keV electron. Producing a viable fast-cured and thermal-neutron-sensitive detector enables the capability to pursue cost-effective 3D printed thermal neutron detectors in a timely manner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deadtime Calculations of Liquid Scintillator Neutron Detector Using Attenuation Law

Scientists have been working on deadtime problems for radiation detectors since 1940's. In detector systems, a minimum time must separate two different events before they can be measured individually. That minimum time interval is called to be deadtime of detector system. There are two commonly deadtime models: the paralyzing and the non-paralyzing models. Paralyzing model assumes that each event during the deadtime will reset the deadtime and deadtime extension will depend on the count rate. According to the non-paralyzing model, deadtime is fixed after each detected event and all events occurring during deadtime are lost. In this study, deadtime measurements have been obtained for an N-Probe fast neutron (NE-213 Liquid Scintillation) detector manufactured by BTI (Bubble Technology Industries) using a combination of the attenuation law and the assumption of ideal paralyzing and non-paralyzing method. Bubble Technology Industries (BTI) has manufactured a portable neutron scintillation spectrometer (N-Probe) with potential applications at nuclear reactor facilities, waste processing operations, and spent fuel storage areas. The deadtime of the N-Probe detector is not provided by the manufacturer; BTI, and there is no other study published on the N-Probe detector' deadtime. Since the detector will be used in future nuclear fuel investigations, it is important to determine the detector' deadtime for accurate nuclear fuel analysis. The deadtime of the BTI N-Probe was examined using different thicknesses of Plexiglas at the Missouri University of Science and Technology Reactor (MSTR) using attenuation law and average macroscopic cross-section of Plexiglas defined by both paralyzing and non-paralyzing model. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scintillation properties and increased vacancy formation in cerium and calcium co-doped yttrium aluminum garnet

Co-doping with divalent elements is known to improve the light yield and decay times of some cerium-activated scintillators, despite the stabilization of tetravalent Ce 4+ , previously believed to be non-luminescent, from the Ce 3+ state. Ce 4+ stabilization is a charge compensation mechanism which results from divalent ion substitution of a 3+site. To elucidate the underlying mechanisms, which remain poorly understood, we have grown three Ce,Ca:YAG crystals with different amounts of calcium co-dopants by the Czochralski method and characterized their scintillation and defect properties. Calcium co-doping reduces the decay times and stabilizes the formation of Ce 4+ as expected. Interestingly, X-ray fluorescence analysis reveals a decreased concentration of cerium within the YAG crystal for the sample doped with high levels of Ca, which could contribute to the observation that scintillator properties are improved only for low levels of Ca co-doping. Additionally, positron annihilation spectroscopy reveals an increase in the concentration of vacancies with increasing Ca concentration, while thermoluminescence is observed to show no detectable signal. Furthermore, room temperature photoluminescence of the Ce 4f to 5d 1 transition demonstrates decreased emission with increasing Ca co-doping. These data suggest that Ca co-doping decreases the decay time by creating defects with non-radiative decay pathways.

36 MATERIALS SCIENCE↗

Measuring the scintillation decay time for different energy deposited by γ-rays and neutrons in a Cs 2 LiYCl 6 :Ce 3+ detector

In nuclear safeguards and homeland security applications, it is greatly beneficial to simultaneously detect γ-rays, thermal neutrons, and fast neutrons using a single detector with reasonable pulse shape discrimination capability, energy resolution comparable with or even better than NaI(Tl) detectors, and high detection efficiency. Cs 2 LiYCl 6 :Ce 3+ detector (CLYC) scintillation detectors have been proven to be one promising candidate to meet these requirements. In this work, the decay time and fraction of each scintillation component for different energy deposition and incident particle type (γ-ray, thermal neutron, and fast neutron) were investigated based on fitting the PMT anode output with exponential functions. For γ-rays, four components were determined with ultrafast decay time of less than one nanosecond and slow time in the order of magnitude of microsecond. It was found that the dependence on the energy deposited by γ-rays of the fraction as well as the decay time of the three slow components was small. However, significant dependence was observed for the ultrafast component. Two or three components were determined for thermal neutrons and fast neutrons without observing a component with fast decay time. To verify the approach used it was first applied to scintillation pulses induced by γ-rays in a NaI(Tl) detector. We found the results were consistent with well-known data already published in the literature.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimum lithium loading of a liquid scintillator for neutron and neutrino detection

Neutral particle detection in high-background environments is greatly aided by the ability to easily load 6 Li into liquid scintillators. In this work, we describe a readily available and inexpensive liquid scintillation cocktail stably loaded with a Li mass fraction up to 1%. Compositions that give thermodynamically stable microemulsions (reverse-micellar systems) were explored, using a Compton spectrum quenching technique to distinguish these from unstable emulsions. Scintillation light yield and transmittance were characterized. Pulse shape discrimination (PSD) was measured using a 252 Cf source, showing that electron-like and proton-like recoil events are well-resolved even for Li loading up to 1%, providing a means of background suppression in neutron/neutrino detectors. While samples in this work were prepared with nat Li (7.59% 6 Li), the neutron capture peak was clearly visible in the PSD spectrum; this implies that while extremely high capture efficiency could be achieved with 6 Li-enriched material, a very inexpensive neutron-sensitive detector can be prepared with nat Li.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a large-mass, low-threshold detector system with simultaneous measurements of athermal phonons and scintillation light

For this work, we have combined two low-threshold detector technologies to develop a large-mass, low-threshold detector system that simultaneously measures the athermal phonons in a sapphire detector while an adjacent silicon high-voltage detector detects the scintillation light from the sapphire detector. This detector system could provide event-by-event discrimination between electron and nuclear events due to the difference in their scintillation light yield. While such systems with simultaneous phonon and light detection have been demonstrated earlier with smaller detectors, our system is designed to provide a large detector mass with high amplification for the limited scintillation light. Future work will focus on at least an order of magnitude improvement in the light collection efficiency by having a highly reflective detector housing and custom phonon mask design to maximize light collection by the silicon high-voltage detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Total neutron cross-section measurement on CH with a novel 3D-projection scintillator detector

In order to extract neutrino oscillation parameters, long-baseline neutrino oscillation experiments rely on detailed models of neutrino interactions with nuclei. These models constitute an important source of systematic uncertainty, partially because detectors to date have been blind to final state neutrons. Three-dimensional projection scintillator trackers comprise components of the near detectors of the next generation long-baseline neutrino experiments. Due to the good timing resolution and fine granularity, this technology is capable of measuring neutron kinetic energy in neutrino interactions on an event-by-event basis and will provide valuable data for refining neutrino interaction models and ways to reconstruct neutrino energy. Two prototypes have been exposed to the neutron beamline at Los Alamos National Laboratory (LANL) in both 2019 and 2020, with neutron energies between 0 and 800 MeV. In order to demonstrate the capability of neutron detection, the total neutron-scintillator cross section as a function of neutron energy is measured and compared to external measurements. The measured total neutron cross section in scintillator between 98 and 688 MeV is 0.36 ± 0.05 barn.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tl 2 LiYCl 6 : Large Diameter, High Performing Dual Mode Scintillator

Tl 2 LiYCl 6 :Ce (TLYC) is a recently discovered dual mode gamma-ray and neutron scintillator. So far small crystals of this composition have been studied, but for practical applications with affordable price, large-scale crystals are required. In this work, we present successful efforts to grow crack-free single crystals with sizes up to $\varnothing$1" × 5.5". A variety of experimental techniques were employed to investigate the scintillation properties. A $\varnothing$1" × 1.2" TLYC cylinder has a light yield of 25,000 ph/MeV, and its energy resolution is better than 4% at 662 keV. The gamma equivalent energy (GEE) produced by thermal neutron is 1.89 MeVee, along with a neutron induced light yield of 47,000 ph/n. Pulse shape discrimination (PSD) between gamma-rays and neutrons has been successfully shown with a current Figure-of-Merit (FOM) of 2.4. This paper explores the crystal growth, scintillation properties, and potential applications of TLYC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Next-generation neutron detection using a 6 Li glass scintillator composite

Neutron detectors are crucial in fundamental science, nuclear security, safeguards, and civil applications. 3 He-filled gas proportional counters are the gold standard for thermal neutron detection, prized for their efficiency, neutron/gamma discrimination, and stability; however, the scarcity of 3 He has prompted the search for alternatives. Here, we introduce a neutron detector design based on a scintillating composite consisting of 6 Li glass scintillator particles dispersed in an organic matrix. A detector consisting of this scintillating composite, photomultiplier tubes (PMTs) for optical detection, and electronics for reading out the PMT signal in both pulse and current modes was prototyped and characterized using various neutron and gamma sources. The prototype achieves a measured intrinsic detection efficiency of 6.70 ± 0.01%, a die-away time of 10.3 ± 0.1 μs, a negligible gamma misidentification probability, and response linearity up to at least 3.7 × 10 6 incident neutrons/s established via a cross-calibration technique. This detector holds the potential to outperform traditional 3 He-gas-based neutron detection systems, offering a viable alternative amidst the ongoing 3 He shortage and promising advancements in neutron detection technology.

47 OTHER INSTRUMENTATION↗

Devising novel methods for the controlled synthesis with morphology and size control of scintillator materials

Nanoscale scintillators represent an important class of materials underlying the functioning of high resolution, high ‘light yield’ radiation detection equipment, applicable for medicine in addition to security and environmental monitoring. This current study has focused on the controlled synthesis of Cs 2 ZnX 4 (X = Cl, Br) not only due to its very fast and promising radioluminescence decay time but also because no reliable synthesis protocols have been reported for producing nanoscale motifs of this material, to date. Solution-based methods can be used to synthesize products, possessing different, discrete morphologies with the ability to dictate particle size and shape. Specifically, we have demonstrated that a hot injection technique can be used to fabricate nanoscale rods and plates. Using this method, we systematically studied the effect of varying reaction variables, such as (i) reaction temperature, (ii) surfactants, and (iii) reaction time. As synthesized nanorods of Cs 2 ZnCl 4 possessed lengths of 101.3 ± 24.4 nm with widths of 17.3 ± 4.5 nm, whereas Cs 2 ZnBr 4 , created under identical conditions, were characterized by lengths of 206 ± 50 nm and widths of 26.7 ± 12.6 nm. Ligand-assisted re-precipitation (LARP) was used to produce the corresponding micron-sized particles. Under these conditions, we successfully synthesized spindles and spherical particles of Cs 2 ZnCl 4 with sizes of 1.58 ± 0.16 μm and 1.03 ± 0.34 μm, respectively, whereas plates of Cs 2 ZnBr 4 were prepared with average sizes of 0.76 ± 0.21 μm. High resolution synchrotron mapping, using the hard X-ray nanoprobe at NSLS II, was used to confirm the expected spatial distribution of Cs, Zn, and Cl within the as-produced crystals. Nanorods of Cs 2 ZnCl 4 and Cs 2 ZnBr 4 were subsequently tested for scintillation light yield and decay times. Preliminary results showed that Cs 2 ZnCl 4 maintained a light yield of 100–300 photons per MeV with a fast decay component of 2.6 ns. Finally, the Cs 2 ZnBr 4 analogue did not give rise to any perceptible scintillation emission.

36 MATERIALS SCIENCE↗

Development of vertically aligned ZnO-nanowires scintillators for high spatial resolution x-ray imaging

Newly designed scintillator of (0001)-oriented ZnO vertical nanowires (vnws) for X-ray imaging was prepared on a Ga-doped ZnO/soda-lime glass by electrodeposition, and the light emission feature was estimated in a synchrotron radiation facility. The ZnO-vnws scintillator revealed a strong light emission and improved resolution on CMOS image compared with that for the ZnO-layer scintillator, although the light emission performance was deteriorated in comparison to the Lu{sub 3}Al{sub 5}O{sub 12:}Ce{sup 3+}. The light emission property closely related to the nanostructure and the resultant photoluminescence characteristic.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Status of LUMINEU program to search for neutrinoless double beta decay of {sup 100}Mo with cryogenic ZnMoO{sub 4} scintillating bolometers

The LUMTNEU program aims at performing a pilot experiment on 0ν2β decay of {sup 100}Mo using radiopure ZnMoO{sub 4} crystals enriched in {sup 100}Mo operated as cryogenic scintillating bolometers. Large volume ZnMoO{sub 4} crystal scintillators (∼ 0.3 kg) were developed and tested showing high performance in terms of radiopurity, energy resolution and α/β particle discrimination capability. Zinc molybdate crystal scintillators enriched in {sup 100}Mo were grown for the first time by the low-thermal-gradient Czochralski technique with a high crystal yield and an acceptable level of enriched molybdenum irrecoverable losses. A background level of ∼ 0.5 counts/(yr keV ton) in the region of interest can be reached in a large detector array thanks to the excellent detectors radiopurity and particle discrimination capability, suppression of randomly coinciding events by pulse-shape analysis, and anticoincidence cut. These results pave the way to future sensitive searches based on the LUMTNEU technology, capable of approachingand exploring the inverted hierarchy region of the neutrino mass pattern.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physics-informed machine learning for inorganic scintillator discovery

Applications of inorganic scintillators—activated with lanthanide dopants, such as Ce and Eu—are found in diverse fields. As a strict requirement to exhibit scintillation, the 4f ground state (with the electronic configuration of [Xe]4 f n 5 d 0 ) and 5 d 1 lowest excited state (with the electronic configuration of [Xe]4 f n–1 5 d 1 ) levels induced by the activator must lie within the host bandgap. Here we introduce a new machine learning (ML) based search strategy for high-throughput chemical space explorations to discover and design novel inorganic scintillators. Building upon well-known physics-based chemical trends for the host dependent electron binding energies within the 4 f and 5 d 1 energy levels of lanthanide ions and available experimental data, the developed ML model—coupled with knowledge of the vacuum referred valence and conduction band edges computed from first principles—can rapidly and reliably estimate the relative positions of the activator’s energy levels relative to the valence and conduction band edges of any given host chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gas scintillation mitigation in gas Cherenkov detectors for inertial confinement fusion (invited)

Gas Cherenkov detectors provide a time resolved measurement of the fusion burn in inertial confinement fusion experiments. The fusion rate delivers critical benchmark figures, such as burn width and bang time. Recent detector improvements pushed temporal resolution to 10 ps to make burn width measurements on igniting targets possible. First high temporal resolution measurements using CO 2 gas fills had a background signal with a long decay length (tail), which was caused by gas scintillation. This gas scintillation limits the ability of the detector to resolve short burn width and high frequency features in the fusion rate measurements. A thorough investigation of the cause of the tail and mitigation options for gas scintillation is presented here. As a near-term resolution, neon gas is being used to extract fusion burn histories. Paths forward for the next generation of gas Cherenkov detectors are identified including the usage of oxygen as a Cherenkov medium.

47 OTHER INSTRUMENTATION↗