Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

On-Orbit, Immuno-Based, Label-Free White Blood Cell Counting System with Microelectromechanical Sensor Technology (OILWBCS-MEMS)

Aurora Flight Sciences, in partnership with Draper Laboratory, has developed a miniaturized system to count white blood cells in microgravity environments. The system uses MEMS technology to simultaneously count total white blood cells, the five white blood cell differential subgroups, and various lymphocyte subtypes. The OILWBCS-MEMS detection technology works by immobilizing an array of white blood cell-specific antibodies on small, gold-coated membranes. When blood flows across the membranes, specific cells' surface protein antigens bind to their corresponding antibodies. This binding can be measured and correlated to cell counts. In Phase I, the partners demonstrated surface chemistry sensitivity and specificity for total white blood cells and two lymphocyte subtypes. In Phase II, a functional prototype demonstrated end-to-end operation. This rugged, miniaturized device requires minimal blood sample preparation and will be useful for both space flight and terrestrial applications.

Edmonds, Jessica↗

Method Development for In-situ Detection of Latent Herpesvirus DNA from Saliva using Nanopore Sequencing

Research toward latent herpesvirus reactivation has been intensively addressed through Space Shuttle and International Space Station (ISS) investigations. This work has provided the understanding that persistent reactivation of herpesviruses from asymptomatic crew can be detected through viral shedding in saliva, urine, and blood. Occasionally, viral reactivation from the latency stage can pose a threat to crew health (clinical manifestation) before, during, and after flight missions. Furthermore, previous work detailing correlations with immunity indicate that monitoring viral reactivation could be implemented to assess potential immune dysfunction. While in-flight monitoring is desirable, there is no well-established procedure or method for real-time evaluations, and research to date has relied on postflight, ground-based analysis. The development of portable molecular technologies like the miniPCR™ (miniPCR Bio) thermal cycler and the MinION™ sequencer (Oxford Nanopore Technologies) have confirmed that real-time monitoring is possible in extreme and low resource environments. These devices, combined with simple sample preparation methods, have been used to demonstrate bacterial identification onboard the ISS, as well as rapid viral detection in remote locations on Earth. The work here builds upon previous molecular advancements onboard the ISS toward the development and validation of a spaceflight-compatible method for viral detection from crew samples. Several herpesviruses can be detected in saliva, which provides a non-invasive means to collect samples for monitoring. While the basis for this method lies in previous spaceflight investigations, key points for method optimization include DNA extraction from saliva, viral primer selection, and bioinformatic processes for data analysis. To increase viral yield, numerous DNA extraction methods have been evaluated and will be discussed in detail. For initial development and testing, varicella-zoster virus (VZV) is being targeted though open reading frame 51 and 63 (ORF51, ORF63), as the replication origin-binding protein is highly expressed during latency. Optimization of the thermal cycling parameters has resulted in the ability to test the entire process. The full method has been tested with both viral VZV DNA standards and saliva spiked with varying concentrations of VZV. Viral sequence data were mapped to the reference sequence using minimap2. Prior to mapping, DNA sequencing reads were filtered for length and quality, barcodes were removed, and alignment identity calculated. Following further assessments, statistics were compared across multiple sequencing experiments and are being used to determine the success of the protocols. Forward work will include the incorporation of herpes simplex virus 1 (HSV-1) and Epstein-Barr virus (EBV) primers as well as the validation of results to the terrestrial qPCR standard assay. Upon full validation of the developed method, saliva will be collected from 20 healthy subjects and spiked with viral DNA. These samples will be split and assayed with the MinION and standard qPCR assay.

Hang N Nguyen↗

Feasibility Study of a Robotic Science Arm on Future Martian Rotorcraft

Science arms are indispensable tools for planetary exploration, allowing vehicles to interact with and manipulate their surroundings in a manner similar to a human field geologist. A majority of the rovers and landers sent to Mars, beginning with Viking I and II in 1976, have made extensive use of these articulated, arm-like devices that allow for sample collection, surface preparation, instrument positioning, and the deployment of ground-contact sensors. Although proven useful, traditional rovers and landers are limited by the rough and difficult terrain of Mars. However, given the successful demonstration of flight on Mars by the Ingenuity helicopter, efforts are underway to outfit larger rotorcraft with science payloads to allow them to explore Mars’ surface and lower atmosphere with significantly more efficiency than land vehicles. Such vehicles could also be designed to work in tandem with landers or rovers. The Mars Science Helicopter (MSH) is a conceptual hexacopter design that is currently under early development by both NASA Ames and JPL. Equipping a vehicle like MSH with a science arm has the potential to further expand its scientific capabilities. This paper approaches the mission and design requirements to equip a science arm on MSH while highlighting the unique technical challenges for robotic arm and science instrument capability. Current plans for MSH development do not include the addition of a robotic arm to the vehicle. However, it is anticipated that future variants of the MSH design might well incorporate such adaptable surface interactive capabilities.

Robotic Science Arm↗

Analysis of Surface Chemistry and Detector Performance of Chemically Process CdZnTe crystals

The goal is to produce non-conductive smooth surfaces for fabricating low-noise and high-efficiency CdZnTe devices for gamma spectroscopy. Sample preparation and results are discussed. The researachers demonstrated various bulk defects (e.g., dislocations and sub-grain boundaries) and surface defects, and examined their effects on the performance of detectors. A comparison study was made between two chemical etchants to produce non-conductive smooth surfaces. A mixture of bromine and hydrogen peroxide proved more effective than conventional bromine etchant. Both energy resolution and detection efficiency of CZT planar detectors were noticeably increased after processing the detector crystals using improved chemical etchant and processing methods.

36 MATERIALS SCIENCE↗

Volumetric micro-injector for capillary electrophoresis

A volumetric microfluidic injector for capillary electrophoresis (CE) for highly repeatable sample injection has been designed and built to eliminate known injection bias in hydrodynamic injection. A defined volume from 1-10 nL or 0.1-100 nL of sample is confined in a defined region of a micro-valve PDMS microfluidic injector chip and electrophoretic potential is applied to drive sample into a separation device such as an embedded fused silica capillary for separation and detection. Using a 75 μm ID capillary, the RSD of an absorbance peak area as low as 1.32% (n=11) is obtained. As a comparison, the time-dependent injection was tested using the same chip which resulted in an inferior repeatability.

Ha, Noel Seunghyun↗

Tailoring the optical properties of wide-bandgap based microcavities via metal films

We report on the tuning of the optical properties of II-VI-material-based microcavity samples, which is achieved by depositing Ag films on top of the structures. The micro-reflectivity spectra show a spectral shift of the sample resonance dependent on the metal layer thickness. By comparison of the experimental findings with the theoretical calculations applying the transfer matrix method on a metal-dielectric mirror structure, the influence of the metal layer particularly with regard to its partial oxidation was explored. Tamm plasmon modes are created at the interface between an open cavity with three ZnSe quantum wells and a metal layer on top. When tuning the excitonic emission relative to the mode by changing the sample temperature, an anticrossing of the resonances was observed. This is a clear indication that the strong coupling regime has been achieved in that sample configuration yielding a Rabi splitting of 18.5 meV. These results are promising for the realization of polariton-based optical devices with a rather simple sample configuration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The International Space Station Urine Monitoring System (UMS)

A device capable of making in-flight volume measurements of single void urine samples, the Urine Monitoring System (UMS), was developed and flown on seven U.S. Space Shuttle missions. This device provided volume data for each urine void from multiple crewmembers and allowed samples of each to be taken and returned to Earth for post-flight analysis. There were a number of design flaws in the original instrument including the presence of liquid carry-over producing invalid "actual" micturition volumes and cross-contamination between successive users from residual urine in "dead" spots". Additionally, high or low volume voids could not be accurately measured, the on-orbit calibration and nominal use sequence was time intensive, and the unit had to be returned and disassembled to retrieve the volume data. These problems have been resolved in a new version, the International Space Station (ISS) UMS, that has been designed to provide real-time in-flight volume data with accuracy and precision equivalent to measurements made on Earth and the ability to provide urine samples that are unadulterated by the device. Originally conceived to be interfaced with a U.S.-built Waste Collection System (WCS), the unit now has been modified to interface with the Russian-supplied Sanitary Hygiene Device (ASY). The ISS UMS provides significant advantages over the current method of collecting urine samples into Urine Collection Devices (UCDs), from which samples are removed and returned to Earth for analyses. A significant future advantage of the UMS is that it can provide an interface to analytical instrumentation that will allow real-time measurement of urine bioanalytes allowing monitoring of crewmember health status during flight and the ability to provide medical interventions based on the results of these measurements. Currently, the ISS UMS is scheduled to launch along with Node-3 on STS-130 (20A) in December 2009. UMS will be installed and scientific/functional verification completed prior to placing the instrument into operation. Samples collected during the verification sequence will be returned for analyses on STS-131 (19A) currently scheduled for launch in March 2010. The presence of a UMS on ISS will provide the capability to conduct additional collaborative human life science investigations among the ISS International Partners.

Feeback, Daniel L.↗

BPSK Demodulation Using Digital Signal Processing

A digital communications signal is a sinusoidal waveform that is modified by a binary (digital) information signal. The sinusoidal waveform is called the carrier. The carrier may be modified in amplitude, frequency, phase, or a combination of these. In this project a binary phase shift keyed (BPSK) signal is the communication signal. In a BPSK signal the phase of the carrier is set to one of two states, 180 degrees apart, by a binary (i.e., 1 or 0) information signal. A digital signal is a sampled version of a "real world" time continuous signal. The digital signal is generated by sampling the continuous signal at discrete points in time. The rate at which the signal is sampled is called the sampling rate (f(s)). The device that performs this operation is called an analog-to-digital (A/D) converter or a digitizer. The digital signal is composed of the sequence of individual values of the sampled BPSK signal. Digital signal processing (DSP) is the modification of the digital signal by mathematical operations. A device that performs this processing is called a digital signal processor. After processing, the digital signal may then be converted back to an analog signal using a digital-to-analog (D/A) converter. The goal of this project is to develop a system that will recover the digital information from a BPSK signal using DSP techniques. The project is broken down into the following steps: (1) Development of the algorithms required to demodulate the BPSK signal; (2) Simulation of the system; and (3) Implementation a BPSK receiver using digital signal processing hardware.

Garcia, Thomas R.↗

Microsampling techniques for infrared spectroscopic analysis of lunar and terrestrial minerals

Microsampling techniques have been developed for infrared analysis of single mineral grains from lunar rocks and dusts, allowing a detailed molecular structure characterization of these complex fine-grained samples. The methods include special devices for isolating single grains, preparing micropellets from the grains, and obtaining in situ microspecular reflectance spectra from grains in polished rock samples. Although specifically developed for the work on lunar samples, the special techniques for single grain infrared analysis were found to be equally useful in studies of complex terrestrial mineral samples. For example, infrared microanalysis has contributed substantially in solving problems concerned with our natural resources, such as the structural characterization of minerals from commercial iron ores, marine deposits, coal, and fly ash derived from coal.

Estep, P. A.↗

Particulate Removal Using a CO2 Composite Spray Cleaning System

The Planetary Protection surface cleanliness requirements for potential Mars Sample Return hardware that would come in contact with Martian samples may be stricter than previous missions. The Jet Propulsion Laboratory has developed a new technology that will enable us to remove sub-micron size particles from critical hardware surfaces. A hand-held CO2 composite cleaning system was tested to verify its cleaning capabilities. This convenient, portable device can be used in cleanrooms for cleaning after rework or during spacecraft integration and assembly. It is environmentally safe and easy to use. This cleaning concept has the potential to be further developed into a robotic cleaning device on a Mars Lander to be used to clean sample acquisition or sample handling devices in situ. Contaminants of known sizes and concentrations, such as fluorescent microspheres and spores were deposited on common spacecraft material surfaces. The cleaning efficiency results will be presented and discussed.

carbon dioxide↗

Percutaneous ureteral biopsy: safety and diagnostic yield

Purpose: To evaluate safety and diagnostic yield of percutaneous CT-guided biopsy of extrarenal upper urinary tract lesions. Materials and methods: Retrospective review of our institutional database of image-guided biopsies yielded 44 CT-guided percutaneous biopsies in 44 unique patients that targeted ureteral (30, 68%) or other non-renal upper urinary tract lesions (14, 32%) between January 1, 2000 and May 1, 2017. Indications, pre-biopsy imaging, biopsy technique, peri-procedural antithrombotic use, complications including bleeding defined by Society of Interventional Radiology criteria, pathology results, and subsequent imaging were reviewed up to 3 months after the procedure to evaluate safety and diagnostic yield. Results: Mean patient age was 66 (range 27–88) and 23/44 patients were male. The majority (34/44) of lesions were sampled with an 18-gauge biopsy device via a 17-gauge introducer needle, and the remaining 10/44 lesions were sampled with a 19/20 gauge system. The mean number of core samples obtained was 4 (range 2–10). No major complications occurred. Specifically, no patient developed a urine leak or urinary obstruction. Minor complications occurred in 3/44 (7%) biopsies, all retroperitoneal hemorrhages that did not require transfusion or other intervention. Biopsy was adequate for pathologic examination in 41 of 44 (93%) cases. Among patients undergoing surgical resection, biopsy diagnosis was concordant with surgical pathology in 9/10 (90%) cases and discordant in 1/10 (10%). Conclusion: CT-guided percutaneous biopsy of upper urinary tract lesions can be performed safely, with high diagnostic yield, and with a high rate of concordance on subsequent surgical pathology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and validation of a new guidance device for lateral approach stereotactic breast biopsy

Stereotactic breast biopsy (SBB) is the gold standard for minimally invasive breast cancer diagnosis. Current systems rely on one of two methods for needle insertion: A vertical approach (perpendicular to the breast compression plate) or a lateral approach (parallel to the compression plate). While the vertical approach is more frequently used, it is not feasible in patients with thin breasts (<3 cm thick after compression) or with superficial lesions. Further, existing SBB guidance hardware provides at most one degree of rotational freedom in the needle trajectory, and as such requires a separate skin incision for each biopsy target. The authors present a new design of lateral guidance device for SBB, which addresses the limitations of the vertical approach and provides improvements over the existing lateral guidance hardware. Specifically, the new device provides (1) an adjustable rigid needle support to minimize needle deflection within the breast and (2) an additional degree of rotational freedom in the needle trajectory, allowing the radiologist to sample multiple targets through a single skin incision. This device was compared to a commercial lateral guidance device in a series of phantom experiments. Needle placement error using each device was measured in agar phantoms for needle insertions at lateral depths of 2 and 5 cm. The biopsy success rate for each device was then estimated by performing biopsy procedures in commercial SBB phantoms. SBB performed with the new lateral guidance device provided reduced needle placement error relative to the commercial lateral guidance device (0.89{+-}0.22 vs 1.75{+-}0.35 mm for targets at 2 cm depth; 1.94{+-}0.20 vs 3.21{+-}0.31 mm for targets at 5 cm depth). The new lateral guidance device also provided improved biopsy accuracy in SBB procedures compared to the commercial lateral guidance device (100% vs 58% success rate). Finally, experiments were performed to demonstrate that the new device can accurately sample lesions within thin breast phantoms and multiple lesions through a single incision point. This device can be incorporated directly into the clinical SBB procedural workflow, with no additional electrical hardware, software, postprocessing, or image analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Coupling Microdroplet-Based Sample Preparation, Multiplexed Isobaric Labeling, and Nanoflow Peptide Fractionation for Deep Proteome Profiling of the Tissue Microenvironment

There is increasing interest in developing in-depth proteomic approaches for mapping tissue heterogeneity in a cell-type-specific manner to better understand and predict the function of complex biological systems such as human organs. Existing spatially resolved proteomics technologies cannot provide deep proteome coverage due to limited sensitivity and poor sample recovery. Herein, we seamlessly combined laser capture microdissection with a low-volume sample processing technology that includes a microfluidic device named microPOTS (microdroplet processing in one pot for trace samples), multiplexed isobaric labeling, and a nanoflow peptide fractionation approach. The integrated workflow allowed us to maximize proteome coverage of laser-isolated tissue samples containing nanogram levels of proteins. We demonstrated that the deep spatial proteomics platform can quantify more than 5000 unique proteins from a small-sized human pancreatic tissue pixel (∼60,000 μm2) and differentiate unique protein abundance patterns in pancreas. Furthermore, the use of the microPOTS chip eliminated the requirement for advanced microfabrication capabilities and specialized nanoliter liquid handling equipment, making it more accessible to proteomic laboratories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy efficient spark plasma sintering: Breaking the threshold of large dimension tooling energy consumption

An energy efficient spark plasma sintering method enabling the densification of large size samples assisted by very low electric current levels is developed. In this method, the electric current is concentrated in the graphite foils around the sample. High-energy dissipation is then achieved in this area enabling the heating and full densification of large (alumina) parts (Ø 40 mm) at relatively low currents (800 A). The electrothermal mechanical simulation reveals that the electric current needed to heat the large samples is 70% lower in the energy efficient configuration compared to the traditional configuration. The presence of thermal and densification gradients is also revealed for the larger size samples. Potential solutions for this problem are discussed. The experiments confirm the possibility of full densification (96%-99%) of large alumina samples. This approach allows using small (and low cost) SPS devices (generally limited to 10-15 mm samples) for large-size samples (40-50 mm). Finally, the developed technique enables also an optimized energy consumption by large-scale SPS systems.

36 MATERIALS SCIENCE↗

Critical Interface: Poly-Silicon to Tunneling SiO2 for Passivated Contact Performance

Environmental exposure of our thin tunneling SiO2 layer on nCz wafer samples prior to poly-Silicon (poly-Si) deposition critically impacts the resulting contact passivation. We present ToF-SIMS evidence of SiO2 oxide storage-induced degradation, presumably by surface contaminants such as carbon, in symmetric and device poly-Si/SiO2 lifetime samples as well as in finished cells. We also present methods to resurrect a contaminated SiO2 layer, including UV-O3 treatment prior to passivated contact formation to produce >21% TCO-free solar cells.

14 SOLAR ENERGY↗

High density flux of Co nanoparticles produced by a simple gas aggregation apparatus

Gas aggregation is a well known method used to produce clusters of different materials with good size control, reduced dispersion, and precise stoichiometry. The cost of these systems is relatively high and they are generally dedicated apparatuses. Furthermore, the usual sample production speed of these systems is not as fast as physical vapor deposition devices posing a problem when thick samples are needed. In this paper we describe the development of a multipurpose gas aggregation system constructed as an adaptation to a magnetron sputtering system. The cost of this adaptation is negligible and its installation and operation are both remarkably simple. The gas flow for flux in the range of 60-130 SCCM (SCCM denotes cubic centimeter per minute at STP) is able to completely collimate all the sputtered material, producing spherical nanoparticles. Co nanoparticles were produced and characterized using electron microscopy techniques and Rutherford back-scattering analysis. The size of the particles is around 10 nm with around 75 nm/min of deposition rate at the center of a Gaussian profile nanoparticle beam.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Apparatus and methods for manipulation and optimization of biological systems

The invention provides systems and methods for manipulating, e.g., optimizing and controlling, biological systems, e.g., for eliciting a more desired biological response of biological sample, such as a tissue, organ, and/or a cell. In one aspect, systems and methods of the invention operate by efficiently searching through a large parametric space of stimuli and system parameters to manipulate, control, and optimize the response of biological samples sustained in the system, e.g., a bioreactor. In alternative aspects, systems include a device for sustaining cells or tissue samples, one or more actuators for stimulating the samples via biochemical, electromagnetic, thermal, mechanical, and/or optical stimulation, one or more sensors for measuring a biological response signal of the samples resulting from the stimulation of the sample. In one aspect, the systems and methods of the invention use at least one optimization algorithm to modify the actuator's control inputs for stimulation, responsive to the sensor's output of response signals. The compositions and methods of the invention can be used, e.g., to for systems optimization of any biological manufacturing or experimental system, e.g., bioreactors for proteins, e.g., therapeutic proteins, polypeptides or peptides for vaccines, and the like, small molecules (e.g., antibiotics), polysaccharides, lipids, and the like. Another use of the apparatus and methods includes combination drug therapy, e.g. optimal drug cocktail, directed cell proliferations and differentiations, e.g. in tissue engineering, e.g. neural progenitor cells differentiation, and discovery of key parameters in complex biological systems.

Ho, Chih-Ming↗

Rotary Percussive Sample Acquisition Tool (SAT): Hardware Development and Testing

In support of a potential Mars Sample Return (MSR) mission an Integrated Mars Sample Acquisition and Handling (IMSAH) architecture has been proposed to provide a means for Rover-based end-to-end sample capture and caching. A key enabling feature of the architecture is the use of a low mass sample Acquisition Tool (SAT) that is capable of drilling and capturing rock cores directly within a sample tube in order to maintain sample integrity and prevent contamination across the sample chain. As such, this paper will describe the development and testing of a low mass rotary percussive SAT that has been shown to provide a means for core generation, fracture, and capture.

Integrated Mars Sample Acquisition and Handling (I↗