Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Resonator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Miniature Magnetic Resonance Spectrometers

For the purpose of in-situ planeatry exploration, such as chemical characterization of Martian surface materials by miniature instruments, we have developed miniature Magnetic Resonance Spectrometers (MRS) namely, Nuclear Magnetic Resonance (NMR) and Electron Paramagnetic Resonance (EPR) spectrometers at JPL.

Proton-NMR↗

Microwave Photoelasticity: Exploiting Multiple Resonances to Measure Stress Changes within Yttria-Partially-Stabilized-Zirconia

The NASA Glenn Research Center is developing non-destructive-testing (NDT) methods to enable the measurement of stresses embedded in optically opaque materials using microwave radiation in a free-space quasi-optical system. This methodology tracks microwave resonances observed in reflected scattering parameters extracted from materials under load. In this paper, we report the successful measurement of the stress-optic-coefficient of bulk yttria-partially stabilized zirconia (YTZP) ceramic of C = 1.42 x 10-4 ± 6.65 x 10-6 (1/GPa), across W-Band (80-100 GHz), and determined that this result is independent of sample thickness. The primary goal of this research is to establish a methodology to quantify and assess the life expectancy of ceramic thermal and environmental barrier coating (TBCs/EBCs). Bulk YTZP samples can undergo multiple resonances within a contiguous measurement bandwidth, each corresponding to an integer multiple wave number ∝. This allows for the acquisition and analysis of multiple stress measurement points within a single sample. As an additional benefit, one can approximate the refractive index of YTZP across a wide bandwidth by observing multiple resonances produced by a set of samples with varying thicknesses. Using this approach, the refractive index of bulk YTZP was found to be n = 5.80 ± 0.043 across the 85-115 GHz frequency band.

Seth W. Waldstein↗

Local Ultrasonic Resonance Spectroscopy of Lithium Metal Batteries for Aerospace Applications

As next-generation aircraft and vehicles continue to develop, so do their associated energy demands. Lithium metal batteries are a leading candidate to fulfill this energy requirement, but these batteries are prone to internal dendrite defects that can lead to catastrophic thermal runaway events. Current battery management systems are capable of mitigating such risks, but are unable to detect such defects until thermal runaway has already begun. Various nondestructive evaluation (NDE) techniques, particularly ultrasonic NDE, can directly monitor internal battery parameters giving them the potential to detect critical defects prior to catastrophic failure. However, most of the current battery NDE research has focused on improved battery state-of-charge (SOC) and stateof- health (SOH) monitoring with little emphasis on critical defect detection. Thus, a measurement technique sensitive to subtle battery defects is needed. In addition, the complex mechanics of ultrasound in porous, thin, multilayered batteries prompt the use of physics-based simulation to guide inspections. In this work, an ultrasonic NDE technique has been developed utilizing frequency domain analysis of local battery resonances to detect the presence of battery defects. This technique is a practical extension of local ultrasonic resonance spectroscopy (LURS) – which previously required non-contact laser ultrasonics – to measurements with piezoelectric contact and immersion scan transducers. To extend the technique to work with piezoelectric transducers, ultrasonic battery measurements were compared to a sans-battery calibration measurement. Then, a linear systems deconvolution was used to eliminate the transfer functions of extraneous factors such as the transducer and electronics, leaving only the frequency-dependent battery reflection coefficient. The LURS technique was first validated on stainless steel and aluminum plates, producing reflection coefficients in line with analytical and numerical finite element modeling (FEM) results. Functioning Li-metal pouch cells were then seeded with lithium chip defects prior to LURS measurements. The presence of these defects is shown to cause a measurable shift in the battery’s through-thickness local resonances. 2D, frequency-domain poroelastic models of ultrasonic propagation in a single-cell lithium metal pouch battery were created and corroborated these findings. Thus, this work has both extended and proven the feasibility of the LURS technique in the detection of local battery defects.

Ultrasound↗

Composite Piezoelectric Resonator 1D Modeling with Loss

Abstract – Maximizing the benefit of applying piezoelectric materials in composite structures, which are a mix of piezoelectric and elastic elements, requires analytical modeling. In this paper we describe two main classes of resonators and how to model using network equivalent including material losses. These include extensional devices where the layer areas are parallel to the direction of wave travel as found in a variety of thickness or length mode transducers (BC. Stress T1 = T2 at boundary) and transverse mode resonators (BC. Strain S1 = S2 at boundary) where the major layer area is perpendicular to the wave direction as is found in radial mode or length thickness mode composite resonators. In order to illustrate these models we will use Mason’s equivalent circuits with elastic, dielectric and piezoelectric loss. It is noted that in order to maintain consistency with the linear equations of piezoelectricity and the wave equation care is required when applying complex loss coefficients to the models. Although these techniques are applicable to other models we use Mason’s network equivalent circuit because it is intuitive for composite modeling due to the frequency independent turns ratio and the independence of the equations describing the elastic layers from the adjoining layer properties which aids in understanding the boundary conditions to impose on the layer boundaries. We will present network models for a variety of applications with loss and show how to calculate their impedance spectra, interface stress, strain velocity and displacement spectra.

Sherrit, Stewart↗

Invariant Funnels for Resonant Landing Orbits

We discovered a simple, two-part solution to the problem of finding resonant orbits to land on high latitudes of Ocean Worlds. First, we apply a standard planar Poincare ́ map in the spatial problem to identify a resonant landing orbit. Next we generate an ”invariant funnel” of trajectories that converge to the orbit, which acts as an attractor. The funnel has a wide mouth, thousands of kilometers wide, that shrinks to a small disc at a landing site only a few kilometers (or less) wide. These funnels are governed by ”resonant rings” of landing trajectories, and will make navigation more simple and robust.

Close, Sigrid↗

Adiabatic Evolution Due to the Conservative Scalar Self-force During Orbital Resonances

We calculate the scalar self-force experienced by a scalar point-charge orbiting a Kerr black holealongrθ-resonant geodesics. We use the self-force to calculate the averaged rate of change of thecharge’s orbital energy⟨ ̇E⟩, angular momentum⟨ ̇Lz⟩, and Carter constant⟨ ̇Q⟩, which togethercapture the leading-order adiabatic, secular evolution of the point-charge. Away from resonances,only the dissipative (time antisymmetric) components of the self-force contribute to⟨ ̇E⟩,⟨ ̇Lz⟩, and⟨ ̇Q⟩. We demonstrate, using a new numerical code, that duringrθresonances conservative (timesymmetric) scalar perturbations also contribute to⟨ ̇Q⟩and, thus, help drive the adiabatic evolutionof the orbit. Furthermore, we observe that the relative impact of these conservative contributionsto⟨ ̇Q⟩is particularly strong for eccentric 2:3 resonances. These results provide the first conclusivenumerical evidence that conservative scalar perturbations of Kerr spacetime are nonintegrable duringrθresonances.

Zachary Nasipak↗

New Tools for Tour Design: Swiss Cheese Plot, Invariant Funnel, and Resonant Encounter Map

We define a new set of tools for tour design introduced in previous work: the”Swiss Cheese Plot,” ”Invariant Funnel,” and ”Resonant Encounter Map.” These tools promise to be useful in designing, analyzing, and navigating low-energy trajectories through multi-body systems. We review and clarify methods for generating the swiss cheese plot and invariant funnels in the Circular Restricted Three-Body Problem. We introduce the resonant encounter map as a graphical representation of the three-body design space, similar to the pork-chop plot for the two-body problem. We also discuss some interesting characteristics of the resonant encounter map and its connection to the invariant manifolds of periodic libration orbit

Close, Sigrid↗

Resonance sound absorber with yielding wall

A single-sheet resonance system for normal incidence of sound was investigated to study in detail the effect of sympathetic vibration of the resonator front wall on sound absorption.

INSTRUMENTS - RESONATORS↗

Photorefractivity in WGM resonators

We report on observation of photorefractive effects in whispering gallery mode resonators made of as-grown and magnesium doped lithium niobate and lithium tantalate in the near as well as far infrared. The effects manifested themselves as dynamic modification of the spectra as well as quality factors of the resonators coupled to the laser radiation. We have observed a significant (exceeding 10-4) change of the ordinary index of refraction of all the materials exposed with 780 nm light. Photorefractive effects have also been detected at 1550 nm. Our experiments support the conclusion that the photorefractivity does not have a distinct red boundary. We show that the maximum saturated refractive index change in the infrared is of the same order of magnitude as in the visible light.

optical resonator↗

High-Order Tunable Filters Based on a Chain of Coupled Crystalline Whispering Gallery-Mode Resonators

We demonstrate experimentally a tunable third-order optical filter fabricated from the three voltage-controlled lithium niobate whispering gallery-mode resonators. The filter operates at 1550 nm with 30-MHz bandwidth and can be electrooptically tuned by 12 GHz in the linear regime with approximately 80-MHz/V tuning rate. With this filter, we have demonstrated 6-dB fiber-to-fiber insertion loss and 30-ns tuning speed, limited by the resonator buildup time.

optical resonators↗

(abstract) Vibration Method for Tracking the Resonant Mode and Impedance of a Microwave Cavity

We have developed a vibration technique to continuously maintain mode resonance and impedance match between a constant frequency magnetron source and resonant cavity. This method uses a vibrating metal rod to modulate the volume of the cavity that is equivalent to modulating an adjustable plunger. A similar vibrating metal rod attached to a stub tuner modulates the waveguide volume between the source and cavity. A phase sensitive detection scheme determines the optimum position of the adjustable plunger and stub tuner. The improved power transfer during the heating of a 99.8% pure alumina rod was demonstrated using this new technique. Temperature-time and reflected power-time plotswill be presented for the cases of no tracking, impedance tracker only, mode tracker only, and simultaneous impedance and mode tracking. Internal melting of the alumina rod near 2000°C with both trackers on will also be discussed.

microwave↗

Evaluation of muscle injury using magnetic resonance imaging

The objective of this study was to investigate spin echo T2 relaxation time changes in thigh muscles after intense eccentric exercise in healthy men. Spin echo and calculated T2 relaxation time images of the thighs were obtained on several occasions after exercise of one limb; the contralateral limb served as control. Muscle damage was verified by elevated levels of serum creatine kinase (CK). Thirty percent of the time no exercise effect was discernible on the magnetic resonance (MR) images. In all positive MR images (70%) the semitendinosus muscle was positive, while the biceps femoris, short head, and gracilis muscles were also positive in 50% and 25% of the total cases, respectively. The peak T2 relaxation time and serum CK were correlated (r = 0.94, p<0.01); temporal changes in muscle T2 relaxation time and serum CK were similar, although T2 relaxation time remained positive after serum CK returned to background levels. We conclude that magnetic resonance imaging can serve as a useful tool in the evaluation of eccentric exercise muscle damage by providing a quantitative indicator of damage and its resolution as well as the specific areas and muscles.

NASA Discipline Number 26-10↗

[Measurement of left atrial and ventricular volumes in real-time 3D echocardiography. Validation by nuclear magnetic resonance]

The measurement of the left ventricular ejection fraction is important for the evaluation of cardiomyopathy and depends on the measurement of left ventricular volumes. There are no existing conventional echocardiographic means of measuring the true left atrial and ventricular volumes without mathematical approximations. The aim of this study was to test anew real time 3-dimensional echocardiographic system of calculating left atrial and ventricular volumes in 40 patients after in vitro validation. The volumes of the left atrium and ventricle acquired from real time 3-D echocardiography in the apical view, were calculated in 7 sections parallel to the surface of the probe and compared with atrial (10 patients) and ventricular (30 patients) volumes calculated by nuclear magnetic resonance with the simpson method and with volumes of water in balloons placed in a cistern. Linear regression analysis showed an excellent correlation between the real volume of water in the balloons and volumes given in real time 3-dimensional echocardiography (y = 0.94x + 5.5, r = 0.99, p < 0.001, D = -10 +/- 4.5 ml). A good correlation was observed between real time 3-dimensional echocardiography and nuclear magnetic resonance for the measurement of left atrial and ventricular volumes (y = 0.95x - 10, r = 0.91, p < 0.001, D = -14.8 +/- 19.5 ml and y = 0.87x + 10, r = 0.98, P < 0.001, D = -8.3 +/- 18.7 ml, respectively. The authors conclude that real time three-dimensional echocardiography allows accurate measurement of left heart volumes underlying the clinical potential of this new 3-D method.

Non-NASA Center↗