Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Quantifying the value of redundant measurements at GCOS Reference Upper-Air Network sites

The potential for measurement redundancy to reduce uncertainty in atmospheric variables has not been investigated comprehensively for climate observations. We evaluated the usefulness of entropy and mutual correlation concepts, as defined in information theory, for quantifying random uncertainty and redundancy in time series of the integrated water vapour (IWV) and water vapour mixing ratio profiles provided by five highly instrumented GRUAN (GCOS, Global Climate Observing System, Reference Upper-Air Network) stations in 2010–2012. Results show that the random uncertainties on the IWV measured with radiosondes, global positioning system, microwave and infrared radiometers, and Raman lidar measurements differed by less than 8%. Comparisons of time series of IWV content from ground-based remote sensing instruments with in situ soundings showed that microwave radiometers have the highest redundancy with the IWV time series measured by radiosondes and therefore the highest potential to reduce the random uncertainty of the radiosondes time series. Moreover, the random uncertainty of a time series from one instrument can be reduced by ~ 60% by constraining the measurements with those from another instrument. The best reduction of random uncertainty is achieved by conditioning Raman lidar measurements with microwave radiometer measurements. In conclusion, specific instruments are recommended for atmospheric water vapour measurements at GRUAN sites. This approach can be applied to the study of redundant measurements for other climate variables.

54 ENVIRONMENTAL SCIENCES↗

Performance of Two Battery Prognostic Applications used by Two Octocopters for Safe Low Altitude Autonomous Flight Operations

This paper addresses the problem of building trust in online predictions of the remaining available flying time for two different electric Unmanned Aerial Vehicles (eUAVs) powered by lithium-ion-polymer batteries. Flight tests for various automation research missions for the two vehicles were monitored using two on-board battery health management applications to make predictions of the remaining flying time (RFT) for each eUAV and to predict the state of the battery. Playback of the voltage, current and temperature profiles of the battery discharge were used to assess the accuracy of the estimation of the voltage and the charge states of the models as well as the estimate of the RFT. The reference ground truth values were the observed landing time and the measured battery pack resting pack voltage 20 minutes after the flight. The predicted RFT, state of charge (SoC), and state of energy (SoE) were compared with the observed results. Noise values of one standard deviation from the mean values of the internal charge states of the battery model during a reference run were used to vary the states during simulation. One application used an equivalent circuit model of the electrical dynamics of the battery pack, and the other application used a reduced-order electrochemistry model. The variation of the model state components was compared to the variation in the estimate of the RFT and the variation in the SoE to estimate a confidence factor. Variation in the estimates caused by factors affecting the off-line laboratory parameter identification experiments is considered. Variation in the estimates due to environmental factors are discussed.

Assurance↗

Quantitative impact of changes in marrow cellularity, skeletal size, and bone mineral density on active marrow dosimetry based upon a reference model

Purpose The hematopoietically active tissues of skeletal bone marrow are a prime target for computational dosimetry given potential risks of leukemia and, at higher dose levels, acute marrow toxicity. The complex three‐dimensional geometry of trabecular spongiosa, however, complicates schema for dose assessment in such a way that only a few reference skeletal models have been developed to date, and which are based upon microimaging of a limited number of cadaveric bone spongiosa cores. The question then arises as to what degree of accuracy is achievable from reference skeletal dose models when applied to individual patients or specific exposed populations? Methods Patient variability in marrow dosimetry were quantified for three skeletal sites — the ribs, lumbar vertebrae, and cranium — for the beta‐emitters 45 Ca, 153 Sm, and 90 Y, and the alpha‐particle emitters 223 Ra, 219 Rn, and 215 Po, the latter two being the immediate progeny of the former. For each radionuclide and bone site, three patient parameters were altered from their values in the reference model: (1) bone size as a surrogate for patient stature, (2) marrow cellularity as a surrogate for age‐ or disease‐related changes in marrow adiposity, and (3) the trabecular bone volume fraction as a surrogate for bone mineral density. Marrow dose variability is expressed as percent differences in the radionuclide S value given by the reference model and the patient‐parameterized model. The impact of radionuclide biokinetics on marrow dosimetry was not considered. Results Variations in overall bone size play a very minor role in active marrow dose variability. Marrow cellularity is a significant factor in dose variability for active marrow self‐irradiation, but it plays no role for radionuclides localized to the trabecular bone matrix. Variations in trabecular bone volume fractions impact the active marrow dose variability for short‐range particle emitters 45 Ca, 223 Ra, 219 Rn, and 215 Po in the vertebrae and ribs, skeletal sites with small spongiosa proportions of trabecular bone. In the cranium, with its relative high proportion of trabecular bone, significant differences in marrow dosimetry from the reference model were noted for all radionuclides. Conclusions Skeletal models of active marrow dosimetry should be more fully parameterized to permit closer matching to patient bone density and marrow cellularity, particularly when considering short‐range particle emitters localized to either the bone trabeculae or active marrow, respectively.

Geyer, Amy M.↗

Geometric interpretation of the {gamma} dose distribution comparison technique: Interpolation-free calculation

The {gamma} dose comparison tool has been used by numerous investigators to quantitatively compare multidimensional dose distributions. The {gamma} tool requires the specification of dose and distance-to-agreement (DTA) criteria for acceptable variations between the dose distributions. The tool then provides a comparison that simultaneously evaluates the dose difference and distance to agreement of the two dose distributions. One of the weaknesses of the tool is that the comparison requires one of the dose distributions to have a relatively high spatial resolution, with points spaced significantly closer than the DTA criterion. The determination of {gamma} involves an exhaustive search process, so the computation time is significant if an accurate {gamma} is desired. The reason for the need for high spatial resolution lies with the fact that the {gamma} tool measures the closest point in one of the dose distributions (the evaluated distribution) with individual points of the other distribution (the reference distribution) when the two distributions are normalized by the dose difference and DTA criteria for the dose and spatial coordinates, respectively. The closest point in the evaluated distribution to a selected reference distribution point is the value of {gamma} at that reference point. If individual evaluated dose distribution points are compared, the closest point may not accurately reflect the closest value of the evaluated distribution as if it were interpolated on an infinite resolution grid. Therefore, a reinterpretation of the {gamma} distribution as the closest geometric distance between the two distributions is proposed. This is conducted by subdividing the evaluated distribution into simplexes; line segments, triangles, and tetrahedra for one, two, and three-dimensional (3D) dose distributions. The closest distance between any point and these simplexes can be straightforwardly computed using matrix multiplication and inversion without the need of interpolating the original evaluated distribution. While an exhaustive search is still required, not having to interpolate the evaluated distribution avoids the drastic growth of calculation time incurred by interpolation and makes the {gamma} tool more practical and more accurate. In our experiment, the geometric method accurately computes {gamma} distributions between 3D dose distributions on a 200x200x50 grid within two minutes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lightweight Metal Stamping Optimization Enabled by Artificial Intelligence

Successfully manufacturing an automotive body structure made via the sheet metal stamping process depends upon simultaneous consideration of component design, tooling design, stamping process control, and material properties. In many cases, introducing lightweight sheet materials (e.g., aluminum alloys, magnesium alloys, advanced high strength steels) holds the potential to significantly reduce vehicle weight, but challenges the stamping process by introducing materials with inherently less ductility. Successful and repeatable applications require co-developing the stamping process controls with the varying material properties, including formability. During the stamping process, as soon as the forming limit of the sheet is exceeded, the material shows localized necking which quickly leads to splits. Controlling process variability to avoid these material splits will enable deployment of less formable, lighter, and stronger materials for stamped automotive components. A typical optimization procedure for manufacturing requires an iterative process involving parameter setting, execution of computational simulations, and modifying the parameters. The entire process demands substantial computational time, making it impractical for real-time feedback towards rapid corrective actions required for in-line control for running production processes. To overcome this challenge, artificial intelligence (AI) can be leveraged to determine optimal manufacturing parameters within a single manufacturing cycle time. This research proposes an in-line optimization framework incorporating a trained AI model to predict kidney-shaped die forming. Preliminary results indicate that the AI framework can accurately predict draw-in values based on a given parameter set, a process referred to as forward prediction. Furthermore, the AI framework can also predict the optimal parameter set that leads to the desired draw-in values, referred to as inverse optimization (or backward prediction). This research has been performed in collaborations with USCAR (US Council for Automotive Research) and AutoForm. The members of USCAR are Ford, GM, and Stellantis.

36 MATERIALS SCIENCE↗

Mars Global Reference Atmospheric Model (Mars-GRAM) Version 3.8: Users Guide

Mars Global Reference Atmospheric Model (Mars-GRAM) Version 3.8 is presented and its new features are discussed. Mars-GRAM uses new values of planetary reference ellipsoid radii, gravity term, and rotation rate (consistent with current JPL values) and includes centrifugal effects on gravity. The model now uses NASA Ames Global Circulation Model low resolution topography. Curvature corrections are applied to winds and limits based on speed of sound are applied. Altitude of the F1 ionization peak and density scale height, including effects of change of molecular weight with altitude are computed. A check is performed to disallow temperatures below CO2 sublimination. This memorandum includes instructions on obtaining Mars-GRAM source code and data files and running the program. Sample input and output are provided. An example of incorporating Mars-GRAM as an atmospheric subroutine in a trajectory code is also given.

Justus, C. G.↗

Radar Observation of Large Attenuation in Convective Storms: Implications for the Dropsize Distribution

Airborne meteorological radars typically operate at attenuating wavelengths. The path integrated attenuation (PIA) can be estimated using the surface reference technique (SRT). In this method, an initial value is determined for the radar cross section of the earth surface in a rain-free area in relatively close proximity to the rain cloud. During subsequent observations of precipitation any decrease 'in the observed surface cross section from the reference value s assumed to be a result of the two-way attenuation along the propagation path. In this paper we present selected instances of high PIA observed over land by an airborne radar. The observations were taken in Brazil and Florida during TRMM (Tropical Rainfall Measurement Mission) field campaigns. We compared these observations with collocated and nearly simultaneous ground-based radar observations by an S-band radar that is not subject to significant attenuation. In this preliminary evaluation, a systematic difference in the attenuation in the two storms is attributed to a difference in the raindrop size distributions; this is supported by observations of ZDR (differential reflectivity).

Tian, Lin↗

EUV fluxes in the solar spectrum below 2000 A

The list of EUV fluxes presented at the 1969 IAGA review in Madrid (Hinteregger, 1970) has served as a useful reference in many aeronomical studies, leading to a wide range of opinions regarding both the absolute values in that reference list and the question of estimating EUV fluxes from the only routinely obtained data, i.e., the solar 10.7 cm flux. Advances made since 1969 will be reviewed including previously unpublished observations of the variability of solar EUV for the period from January 1974 to May 1975 which were obtained from the EUV spectrophotometer experiment on the AE-C satellite. The review is concluded by a discussion of current and future needs of solar EUV flux measurements for aeronomical applications.

Hinteregger, H. E.↗

A photometric study of the Orion OB 1 association. 1: Observational data

An extensive catalog of observational data is presented for stars in the region of the young stellar association Orion OB 1. In addition to new photoelectric observations obtained on the uvbyB and UBV systems, photoelectric and spectroscopic data were compiled for the stars observed and for several bright members of the association having available photometric indices. Mean weighted values were computed for the uvbyB and UBV data and are tabulated in summary tables which include all references for individual values. These tables are expected to be reasonably complete for association members earlier than spectral type A0. From an analysis of currently available proper motion, radial velocity, and photometric data, membership criteria were derived and qualitative membership probabilities for 526 stars were summarized. A set of charts is included for assistance in identification of the program stars in all regions of the association.

Warren, W. H., Jr.↗

TU-H-207A-02: Relative Importance of the Various Factors Influencing the Accuracy of Monte Carlo Simulated CT Dose Index

Purpose: Monte Carlo simulation is a frequently used technique for assessing patient dose in CT. The accuracy of a Monte Carlo program is often validated using the standard CT dose index (CTDI) phantoms by comparing simulated and measured CTDI{sub 100}. To achieve good agreement, many input parameters in the simulation (e.g., energy spectrum and effective beam width) need to be determined. However, not all the parameters have equal importance. Our aim was to assess the relative importance of the various factors that influence the accuracy of simulated CTDI{sub 100}. Methods: A Monte Carlo program previously validated for a clinical CT system was used to simulate CTDI{sub 100}. For the standard CTDI phantoms (32 and 16 cm in diameter), CTDI{sub 100} values from central and four peripheral locations at 70 and 120 kVp were first simulated using a set of reference input parameter values (treated as the truth). To emulate the situation in which the input parameter values used by the researcher may deviate from the truth, additional simulations were performed in which intentional errors were introduced into the input parameters, the effects of which on simulated CTDI{sub 100} were analyzed. Results: At 38.4-mm collimation, errors in effective beam width up to 5.0 mm showed negligible effects on simulated CTDI{sub 100} (<1.0%). Likewise, errors in acrylic density of up to 0.01 g/cm{sup 3} resulted in small CTDI{sub 100} errors (<2.5%). In contrast, errors in spectral HVL produced more significant effects: slight deviations (±0.2 mm Al) produced errors up to 4.4%, whereas more extreme deviations (±1.4 mm Al) produced errors as high as 25.9%. Lastly, ignoring the CT table introduced errors up to 13.9%. Conclusion: Monte Carlo simulated CTDI{sub 100} is insensitive to errors in effective beam width and acrylic density. However, they are sensitive to errors in spectral HVL. To obtain accurate results, the CT table should not be ignored. This work was supported by a Faculty Research and Development Award from Cleveland State University.

60 APPLIED LIFE SCIENCES↗

Method and System for Temporal Filtering in Video Compression Systems

Three related innovations combine improved non-linear motion estimation, video coding, and video compression. The first system comprises a method in which side information is generated using an adaptive, non-linear motion model. This method enables extrapolating and interpolating a visual signal, including determining the first motion vector between the first pixel position in a first image to a second pixel position in a second image; determining a second motion vector between the second pixel position in the second image and a third pixel position in a third image; determining a third motion vector between the first pixel position in the first image and the second pixel position in the second image, the second pixel position in the second image, and the third pixel position in the third image using a non-linear model; and determining a position of the fourth pixel in a fourth image based upon the third motion vector. For the video compression element, the video encoder has low computational complexity and high compression efficiency. The disclosed system comprises a video encoder and a decoder. The encoder converts the source frame into a space-frequency representation, estimates the conditional statistics of at least one vector of space-frequency coefficients with similar frequencies, and is conditioned on previously encoded data. It estimates an encoding rate based on the conditional statistics and applies a Slepian-Wolf code with the computed encoding rate. The method for decoding includes generating a side-information vector of frequency coefficients based on previously decoded source data and encoder statistics and previous reconstructions of the source frequency vector. It also performs Slepian-Wolf decoding of a source frequency vector based on the generated side-information and the Slepian-Wolf code bits. The video coding element includes receiving a first reference frame having a first pixel value at a first pixel position, a second reference frame having a second pixel value at a second pixel position, and a third reference frame having a third pixel value at a third pixel position. It determines a first motion vector between the first pixel position and the second pixel position, a second motion vector between the second pixel position and the third pixel position, and a fourth pixel value for a fourth frame based upon a linear or nonlinear combination of the first pixel value, the second pixel value, and the third pixel value. A stationary filtering process determines the estimated pixel values. The parameters of the filter may be predetermined constants.

Lu, Ligang↗

Intercomparison of methods of coupling between convection and large-scale circulation. 1. Comparison over uniform surface conditions

Here, as part of an international intercomparison project, a set of single-column models (SCMs) and cloud-resolving models (CRMs) are run under the weak-temperature gradient (WTG) method and the damped gravity wave (DGW) method. For each model, the implementation of the WTG or DGW method involves a simulated column which is coupled to a reference state defined with profiles obtained from the same model in radiative-convective equilibrium. The simulated column has the same surface conditions as the reference state and is initialized with profiles from the reference state. We performed systematic comparison of the behavior of different models under a consistent implementation of the WTG method and the DGW method and systematic comparison of the WTG and DGW methods in models with different physics and numerics. CRMs and SCMs produce a variety of behaviors under both WTG and DGW methods. Some of the models reproduce the reference state while others sustain a large-scale circulation which results in either substantially lower or higher precipitation compared to the value of the reference state. CRMs show a fairly linear relationship between precipitation and circulation strength. SCMs display a wider range of behaviors than CRMs. Some SCMs under the WTG method produce zero precipitation. Within an individual SCM, a DGW simulation and a corresponding WTG simulation can produce different signed circulation. When initialized with a dry troposphere, DGW simulations always result in a precipitating equilibrium state. The greatest sensitivities to the initial moisture conditions occur for multiple stable equilibria in some WTG simulations, corresponding to either a dry equilibrium state when initialized as dry or a precipitating equilibrium state when initialized as moist. Multiple equilibria are seen in more WTG simulations for higher SST. In some models, the existence of multiple equilibria is sensitive to some parameters in the WTG calculations.

54 ENVIRONMENTAL SCIENCES↗

System and method for motor parameter estimation

A system and method for determining unknown values of certain motor parameters includes a motor input device connectable to an electric motor having associated therewith values for known motor parameters and an unknown value of at least one motor parameter. The motor input device includes a processing unit that receives a first input from the electric motor comprising values for the known motor parameters for the electric motor and receive a second input comprising motor data on a plurality of reference motors, including values for motor parameters corresponding to the known motor parameters of the electric motor and values for motor parameters corresponding to the at least one unknown motor parameter value of the electric motor. The processor determines the unknown value of the at least one motor parameter from the first input and the second input and determines a motor management strategy for the electric motor based thereon.

42 ENGINEERING↗

Radiochronometric analysis of an historic Cs-137 activity standard

In this work, a 137 Cs activity standard discovered during routine inventory was analyzed to determine its model age using radiochronometry. The aqueous activity standard was separated using an established separation method that employs commercially available Sr resin. The method was also tested against a nuclear forensics reference material developed specifically for benchmarking 137 Cs radiochronometry methods. Results of the analyses showed good agreement between the results and the certified values of the reference material. Analysis of the discovered activity standard were also in good agreement with the activity certification date, though uncertainty was higher due to natural Ba contaminating the sample and the stable 133 Cs used as a carrier during the standard’s production.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Investigations and advanced concepts on gyrotron interaction modeling and simulations

In gyrotron theory, the interaction between the electron beam and the high frequency electromagnetic field is commonly modeled using the slow variables approach. The slow variables are quantities that vary slowly in time in comparison to the electron cyclotron frequency. They represent the electron momentum and the high frequency field of the resonant TE modes in the gyrotron cavity. For their definition, some reference frequencies need to be introduced. These include the so-called averaging frequency, used to define the slow variable corresponding to the electron momentum, and the carrier frequencies, used to define the slow variables corresponding to the field envelopes of the modes. From the mathematical point of view, the choice of the reference frequencies is, to some extent, arbitrary. However, from the numerical point of view, there are arguments that point toward specific choices, in the sense that these choices are advantageous in terms of simulation speed and accuracy. In this paper, the typical monochromatic gyrotron operation is considered, and the numerical integration of the interaction equations is performed by the trajectory approach, since it is the fastest, and therefore it is the one that is most commonly used. The influence of the choice of the reference frequencies on the interaction simulations is studied using theoretical arguments, as well as numerical simulations. From these investigations, appropriate choices for the values of the reference frequencies are identified. In addition, novel, advanced concepts for the definitions of these frequencies are addressed, and their benefits are demonstrated numerically.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monte Carlo calculated TG-60 dosimetry parameters for the {beta}{sup -} emitter {sup 153}Sm brachytherapy source

Purpose: The formalism recommended by Task Group 60 (TG-60) of the American Association of Physicists in Medicine (AAPM) is applicable for {beta} sources. Radioactive biocompatible and biodegradable {sup 153}Sm glass seed without encapsulation is a {beta}{sup -} emitter radionuclide with a short half-life and delivers a high dose rate to the tumor in the millimeter range. This study presents the results of Monte Carlo calculations of the dosimetric parameters for the {sup 153}Sm brachytherapy source. Methods: Version 5 of the (MCNP) Monte Carlo radiation transport code was used to calculate two-dimensional dose distributions around the source. The dosimetric parameters of AAPM TG-60 recommendations including the reference dose rate, the radial dose function, the anisotropy function, and the one-dimensional anisotropy function were obtained. Results: The dose rate value at the reference point was estimated to be 9.21{+-}0.6 cGy h{sup -1} {mu}Ci{sup -1}. Due to the low energy beta emitted from {sup 153}Sm sources, the dose fall-off profile is sharper than the other beta emitter sources. The calculated dosimetric parameters in this study are compared to several beta and photon emitting seeds. Conclusions: The results show the advantage of the {sup 153}Sm source in comparison with the other sources because of the rapid dose fall-off of beta ray and high dose rate at the short distances of the seed. The results would be helpful in the development of the radioactive implants using {sup 153}Sm seeds for the brachytherapy treatment.

60 APPLIED LIFE SCIENCES↗

Economic dispatch for electricity merchant with energy storage and wind plant: State of charge based decision making considering market impact and uncertainties

Here this paper investigates how the market impact of electricity merchants and uncertainty of wind generation affect their co-optimized scheduling policy, specifically for merchants who have both energy storage and wind plants. In the existing literature, merchants' trading actions are usually assumed not to affect market prices; however, a large-scale energy storage merchant's actions can affect market prices. To this end, we approximate the electricity price by a linear function of the quantity of power traded by the merchant in the reward function to achieve decision-making incorporating the market impact. This paper utilizes the dynamic programming approach to analyze merchants' optimal multi-period decision-making incorporating market impact, uncertain wind generation, and energy storage constraints. First, our results demonstrate that for a merchant with co-located energy storage facilities and wind power plants, the energy storage's feasible state of charge (SOC) range can be segmented into four possible sub-ranges by three analytically developed SOC reference points. The unique optimal trading decision can be achieved by comparing the current energy inventory and the SOC references of the next period. Second, our results show that market impact and uncertainties substantially change the optimal storage scheduling policy by impacting the values of the reference points. To mitigate the negative effect of the merchant's market impact on buying and selling actions, the merchant may reduce the amount of generating or pumping electricity each period to maximize profit. Moreover, we identify and investigate the trade-off between market price and transaction quantity. Our findings provide co-optimized scheduling guidance for electricity merchants with co-located energy storage and renewable power plants systems.

17 WIND ENERGY↗

Ceramic Composite Inert Matrix Fuel Forms in High-Temperature Gas-Cooled Microreactors

Here, this work optimizes micro-prismatic high-temperature gas reactor (HTGR) designs to reduce the energy-normalized mass of spent nuclear fuel (SNF) and high-level waste (HLW) produced. The optimization was performed for the current graphite moderator and an inert matrix fuel (IMF) concept employing different composite moderators in a prismatic design architecture. The fuel matrix is magnesium oxide (MgO) with entrained tristructural-isotropic (TRISO) fuel. The moderator materials, including beryllium oxide (MgO-BeO) and beryllium (MgO-Be) at 40 vol % loading and yttrium hydride (MgO-YH x=1.9 ) and zirconium hydride (MgO-ZrH x=1.9 ) at 15 vol % loading, were entrained within the MgO host matrix. A generic graphite micro-prismatic HTGR is used as the baseline point design where the external dimensions are held constant. The composite moderator designs use 19.9% enriched uranium nitride TRISO fuel and hexagonal assemblies. For each IMF concept, an optimization study was performed to maximize the discharge burnup of the fuel by varying the TRISO packing fraction and the lattice pitch of the assemblies. The mass of SNF and HLW, other waste metrics, fuel cost, environmental impact metrics, and the activity of the SNF and HLW at 100 years and 100 000 years were calculated for the optimized IMF and graphite reference designs. The IMF results were subsequently compared to those of the graphite reference and the values for a light water reactor (LWR) and a small modular LWR. For the SNF and HLW, all the IMF concepts and the graphite reference produced less waste compared to the traditional LWR designs. However, the IMF concepts outperformed the graphite reference regarding the mass of SNF and HLW. For the other waste metrics, the IMF concepts showed reductions in fuel cost with improved environmental metrics relative to the graphite reference. Overall, the IMF concepts significantly reduced the SNF and HLW produced per unit of energy generated compared to traditional LWR designs.

TRISO↗