Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Frame”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Study of B̄→X u lν̄ decays in BB̄ events tagged by a fully reconstructed B-meson decay and determination of |V ub |

We report measurements of partial branching fractions for inclusive charmless semileptonic B decays B¯¯¯→X u lν¯ and the determination of the Cabibbo–Kobayashi–Maskawa (CKM) matrix element |V ub |. The analysis is based on a sample of 467×10⁶ Υ(4S)→BB¯¯¯ decays recorded with the BABAR detector at the PEP-II e⁺e⁻ storage rings. We select events in which the decay of one of the B mesons is fully reconstructed and an electron or a muon signals the semileptonic decay of the other B meson. We measure partial branching fractions ΔB in several restricted regions of phase space and determine the CKM element |V ub | based on different QCD predictions. For decays with a charged lepton momentum p * l >1.0 GeV in the B meson rest frame, we obtain ΔB=(1.80±0.13stat±0.15sys±0.02theo)×10⁻³ from a fit to the two-dimensional M X -q² distribution. Here, M X refers to the invariant mass of the final state hadron X and q² is the invariant mass squared of the charged lepton and neutrino. From this measurement we extract |V ub |=(4.33±0.24 exp ±0.15 theo )×10⁻³ as the arithmetic average of four results obtained from four different QCD predictions of the partial rate. We separately determine partial branching fractions for B¯¯¯0 and B⁻ decays and derive a limit on the isospin breaking in B¯¯¯→X u lν¯ decays.

Lees, J. P.↗

WE-AB-204-08: Uncertainties in Kinetic Modeling of Shortened Dynamic 18F-FMISO PET Due to Image Noise

Purpose: To assess uncertainties in voxel-wise kinetic modeling (KM) of dynamic 18F-FMISO PET (dPET) due to image noise for different lengths of dPET acquisitions. Methods: 12 tumor time activity curves (TACs) deduced from 6 head and neck cancer patient dPET datasets (45min dPET + 10min frames at ∼95min and ∼160min respectively) were modeled using an irreversible two-tissue compartment model to estimate kinetic rate constants (KRCs) k3, vB, K1, and K1/k2 (reference standard). For each modeled TAC, 1000 noisy TACs were simulated by adding Gaussian noise with standard deviation equivalent to that observed on a voxel level in GE DSTE PET-CT. KM was conducted for each set of noisy TACs using (i) full dataset (170min), and repeated using (ii) 105min and (iii) 45min shortened subsets, with an input function that was image-derived from the dPET dataset of matching length. Absolute value of percent difference between KRCs from noisy TACs as estimated from either of 3 datasets and reference standard KRCs was used to represent bias. Results: For all KRCs, bias was higher for shortened datasets. For k3, bias was lower when actual k3 was higher: from 7%±5% (170min), 9%±7% (105min), and 14%±11% (45min) (actual k3=0.0098), to 32%±25% (170min), 45%±34% (95min), and 79%±48% (45min) (actual k3=0.0008). Similar relationship was observed for vB, with bias being between ∼7% (actual vB=0.28) and ∼26–34% (actual vB=0.08). For K1 [K1/k2], bias was ∼6–10% [∼2–3%] (dependence on actual value of K1 [K1/k2] was not observed). Conclusion: Uncertainties in voxel-wise KM of shortened 18F-FMISO dPET due to image noisy only are larger for shorter acquisitions and, for k3 [vB], the bias was found to be inversely correlated with the actual values of k3 [vB]. Using 45min subset, k3, vB, K1, and K1/k2 could be estimated to within ∼15–80%, ∼10–35%, ∼10%, and ∼3%, respectively.

60 APPLIED LIFE SCIENCES↗

SU-F-303-17: Real Time Dose Calculation of MRI Guided Co-60 Radiotherapy Treatments On Free Breathing Patients, Using a Motion Model and Fast Monte Carlo Dose Calculation

Purpose: To demonstrate real-time dose calculation of free-breathing MRI guided Co−60 treatments, using a motion model and Monte-Carlo dose calculation to accurately account for the interplay between irregular breathing motion and an IMRT delivery. Methods: ViewRay Co-60 dose distributions were optimized on ITVs contoured from free-breathing CT images of lung cancer patients. Each treatment plan was separated into 0.25s segments, accounting for the MLC positions and beam angles at each time point. A voxel-specific motion model derived from multiple fast-helical free-breathing CTs and deformable registration was calculated for each patient. 3D images for every 0.25s of a simulated treatment were generated in real time, here using a bellows signal as a surrogate to accurately account for breathing irregularities. Monte-Carlo dose calculation was performed every 0.25s of the treatment, with the number of histories in each calculation scaled to give an overall 1% statistical uncertainty. Each dose calculation was deformed back to the reference image using the motion model and accumulated. The static and real-time dose calculations were compared. Results: Image generation was performed in real time at 4 frames per second (GPU). Monte-Carlo dose calculation was performed at approximately 1frame per second (CPU), giving a total calculation time of approximately 30 minutes per treatment. Results show both cold- and hot-spots in and around the ITV, and increased dose to contralateral lung as the tumor moves in and out of the beam during treatment. Conclusion: An accurate motion model combined with a fast Monte-Carlo dose calculation allows almost real-time dose calculation of a free-breathing treatment. When combined with sagittal 2D-cine-mode MRI during treatment to update the motion model in real time, this will allow the true delivered dose of a treatment to be calculated, providing a useful tool for adaptive planning and assessing the effectiveness of gated treatments.

60 APPLIED LIFE SCIENCES↗

First Road / River Barge Security Transport of SNF under the New German Transport Security Guidelines - 19102

A transfer of 342 spent fuel assemblies from NPP Obrigheim to NPP Neckarwestheim, both located alongside the river Neckar in the south of Germany, is required to promote the decommissioning process of NPP Obrigheim, which started in 2008 after the NPP had been shut down three years before. The spent fuel storage facility in Neckarwestheim offers sufficient storage space to accept the 342 SNF assemblies, stored in fifteen dry casks type CASTOR{sup R} 440/84 mvK. After several transport feasibility studies had been conducted, Daher Nuclear Technologies GmbH was awarded the commission to plan, prepare and conduct the SNF transport. Since the combined road / river barge transport promised to be the most suitable mode of transportation Daher Nuclear Technologies started to prepare its security concept, a prerequisite to apply for and attain the transport license mandatory for transporting spent nuclear fuel in Germany. In March 2014 the company applied for the transport license, which, after more than three years and numerous amendments to the security concept, was finally granted to Daher Nuclear Technologies on May 16, 2017 by the German Federal Office for the Safety of Nuclear Waste Management (successor organization of the BfS). Simultaneously to the license application phase the transport equipment - amongst others the heavy-duty trucks and trailers, the pusher tugs, the river barge and transport frames - had to be provided and modified to meet the intensified requirements of the New German Transport Security Guidelines Road / Rail as well as several other legal regulations referring to the transport of dangerous goods by road and inland waterways (e.g. ADR - European Agreement concerning the International Carriage of Dangerous Goods by Road and ADN - European Agreement concerning the International Carriage of Dangerous Goods by Inland Waterways). The planning process involved various meetings with representatives of different authorities and administrative bodies incl. accredited experts as well as subcontractors. Tremendous training efforts had to be undertaken to train more than 100 transport participants regarding security measures, health, safety and environmental measures, as well as the proper handling of radioactive material. This also included the training of the security staff, that had to be qualified in compliance with the new Transport Security Guidelines Road and Rail. Finally, in June 2017, when all preparations where complete, all requirements met, and all permits obtained, the first ever security SNF transport on a German river was performed. Three laden CASTOR{sup R} 440/84 mvK transport and storage casks were transported in one batch via heavy-duty truck-trailer from the NPP Obrigheim to the NPP's own harbor, to be rolled on to the river barge, that would carry the three casks upstream the river Neckar to the approx. fifty kilometer distant NPP Neckarwestheim. The journey on the river took about eleven hours, in which several bridges and locks had to be passed. The entire transport was escorted by qualified security staff and auxiliary police forces on waterways and alongside on roads. It attracted nationwide public attention, due to its pioneer status and the fact, that there hadn't been any SNF or HLW shipments in Germany since 2011. After the convoy safely arrived at NPP Neckarwestheim's pier the three laden CASTOR{sup R} 440/84 mvK casks were rolled off the river barge via heavy-duty truck-trailers to be stored in the on-site interim storage facility. This first transport was a success and was followed by four additionally successful security transports in September, October, November and December 2017. The public attention receded significantly during the transport campaign, which ended on December 19, 2017 with the transfer of the last three of fifteen casks to the on-site interim storage facility in Neckarwestheim. With the last cask safely transferred to the interim storage facility Daher Nuclear Technologies successfully completed the transport campaign on schedule, meeting one of EnBW's fundamental objectives to finish the transfer of the 342 SNF assemblies by the end of 2017. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Noise spatial nonuniformity and the impact of statistical image reconstruction in CT myocardial perfusion imaging

Purpose: To achieve high temporal resolution in CT myocardial perfusion imaging (MPI), images are often reconstructed using filtered backprojection (FBP) algorithms from data acquired within a short-scan angular range. However, the variation in the central angle from one time frame to the next in gated short scans has been shown to create detrimental partial scan artifacts when performing quantitative MPI measurements. This study has two main purposes. (1) To demonstrate the existence of a distinct detrimental effect in short-scan FBP, i.e., the introduction of a nonuniform spatial image noise distribution; this nonuniformity can lead to unexpectedly high image noise and streaking artifacts, which may affect CT MPI quantification. (2) To demonstrate that statistical image reconstruction (SIR) algorithms can be a potential solution to address the nonuniform spatial noise distribution problem and can also lead to radiation dose reduction in the context of CT MPI. Methods: Projection datasets from a numerically simulated perfusion phantom and an in vivo animal myocardial perfusion CT scan were used in this study. In the numerical phantom, multiple realizations of Poisson noise were added to projection data at each time frame to investigate the spatial distribution of noise. Images from all datasets were reconstructed using both FBP and SIR reconstruction algorithms. To quantify the spatial distribution of noise, the mean and standard deviation were measured in several regions of interest (ROIs) and analyzed across time frames. In the in vivo study, two low-dose scans at tube currents of 25 and 50 mA were reconstructed using FBP and SIR. Quantitative perfusion metrics, namely, the normalized upslope (NUS), myocardial blood volume (MBV), and first moment transit time (FMT), were measured for two ROIs and compared to reference values obtained from a high-dose scan performed at 500 mA. Results: Images reconstructed using FBP showed a highly nonuniform spatial distribution of noise. This spatial nonuniformity led to large fluctuations in the temporal direction. In the numerical phantom study, the level of noise was shown to vary by as much as 87% within a given image, and as much as 110% between different time frames for a ROI far from isocenter. The spatially nonuniform noise pattern was shown to correlate with the source trajectory and the object structure. In contrast, images reconstructed using SIR showed a highly uniform spatial distribution of noise, leading to smaller unexpected noise fluctuations in the temporal direction when a short scan angular range was used. In the numerical phantom study, the noise varied by less than 37% within a given image, and by less than 20% between different time frames. Also, the noise standard deviation in SIR images was on average half of that of FBP images. In the in vivo studies, the deviation observed between quantitative perfusion metrics measured from low-dose scans and high-dose scans was mitigated when SIR was used instead of FBP to reconstruct images. Conclusions: (1) Images reconstructed using FBP suffered from nonuniform spatial noise levels. This nonuniformity is another manifestation of the detrimental effects caused by short-scan reconstruction in CT MPI. (2) Images reconstructed using SIR had a much lower and more uniform noise level and thus can be used as a potential solution to address the FBP nonuniformity. (3) Given the improvement in the accuracy of the perfusion metrics when using SIR, it may be desirable to use a statistical reconstruction framework to perform low-dose dynamic CT MPI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Graph Analytics Frameworks Using the GAP Benchmark Suite

The analysis of connected data is an increasingly important application in high-performance computing. Such analyses can reveal fraudulent patterns in financial transactions, optimize telecommunications networks, predict information flow in social networks, etc. However, the landscape of graph analytics is highly diverse. Graph algorithms stress processor architectures differently, and no one graph can represent all topologies. Consequently, no single approach or framework is expected to be optimal for all graph analytics problems. To help make sense of this diverse landscape, we evaluated four approaches to graph analytics: GraphBLAS, Galois, BGL17, GraphIt; and compare them against hand-tuned implementations that take advantage of hardware features on our test platform. Graph- BLAS formulates graph analytics as sparse linear algebra. Galois provides syntactic constructs for data parallelism over irregular data structures. BGL17 is a generic C++ template library for implementing graph algorithms. GraphIt provides a domain- specific language to describe and optimize graph algorithms. We use the GAP Benchmark Suite to establish baseline performance and guide the side-by-side evaluation of each framework. GAP consists of 30 tests: six graph analytics algorithms (breadth- first search, single-source shortest path, PageRank, betweenness centrality, connected components, and triangle counting) run on five graphs, each with different topological characteristics (e.g., high diameter, skewed degree distribution, high average degree). High-performance reference implementations are included for each benchmark algorithm. Because a graph can be loaded into memory a number of ways (e.g., flat file on disk, compressed sparse format, data frames, retrieved from SQL or NoSQL databases), our evaluation focused on computational performance rather than I/O. Our results show the relative strengths of each framework.

Graph algorithms, Benchmarking, shared-memory prog↗

Design of water-moderated heterogeneous cores in new STACY facility through JAEA/IRSN collaboration - 14363

In the post-Fukushima prospect, Japan Atomic Energy Agency, JAEA, intends to re-open its Static Experiment Critical Facility STACY, in order to contribute to the validation of fuel debris calculations in conditions close to those affected by the Fukushima Daiichi Nuclear Power Station accident. The reactor core of STACY is being modified by JAEA from homogeneous solution fuel core to heterogeneous pin- type fuel core. The first step of critical experiments is to establish reference experiments involving lattices of UO{sub 2} rods without fuel debris. A design of such experiments is in progress for the widest range of moderation ratios in the frame of JAEA/IRSN collaboration. To anticipate the specification values of materials to be manufactured (grids, rods), an evaluation of uncertainties pertaining to the different parameters driving k{sub eff} is paramount. The following uncertainties of experimental cores are evaluated to estimate the reactivity effect of engineering tolerance/or measurements of the modified STACY: (1) Density of fuel pellets, (2) Enrichment of uranium, (3) Diameter of fuel pellets, (4) Thickness of fuel claddings, (5) Impurities of fuel pellets, (6) Impurities of fuel claddings and (7) Positioning of fuel rods in the lattice. For these calculations, three types of moderation conditions were considered within the experimental parameters of STACY: the lowest moderation (lattice pitch = 1.15 cm; V{sub m}/V{sub f}=1.2), optimum moderation (lattice pitch = 1.5 cm, V{sub m}/V{sub f} = 2.9) and an over moderated case (lattice pitch = 2.55 cm; V{sub m}/V{sub f} = 11). The calculations to derive the overall uncertainty of modified STACY were performed propagating the 1σ uncertainties of parameters of existing STACY in terms of k{sub eff}. For that purpose, a perturbation calculation (differential operator) technique and a stochastic geometry modeling technique were used with the MCNP5 continuous energy Monte Carlo code and a point-wise cross section library based on the JENDL-4.0 evaluated nuclear data library. Moreover, the results of calculations were compared with those calculated by two continuous energy Monte Carlo codes using the correlated sampling technique: - An experimental version of the Japanese MVP2 code combined to the JENDL-4.0 nuclear data library, - The MORET 5 code, developed by IRSN, combined to the JEFF-3.1 nuclear data library. The proposed paper discusses all the aforementioned issues, and confirms that the uncertainty pertaining to the critical experiments of the STACY is sufficiently small. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Background studies for NaI(Tl) detectors in the ANAIS dark matter project

Several large NaI(Tl) detectors, produced by different companies, have been operated in the Canfranc Underground Laboratory (LSC) in the frame of the ANAIS (Annual modulation with NaI Scintillators) project devoted to the direct detection of dark matter. A complete background model has been developed for a 9.6 kg detector (referred as ANAIS-0 prototype) after a long data taking at LSC. Activities from the natural chains of {sup 238}U and {sup 232}Th, and {sup 40}K in the NaI(Tl) crystal were evaluated applying different methods: discrimination of alpha particles vs beta/gamma background by Pulse Shape Analysis for quantifying the content of the natural chains and coincidence techniques for {sup 40}K. Radioactive contaminations in the detector and shielding components were also determined by HPGe spectrometry. Monte Carlo simulations using Geant4 package were carried out to evaluate their contribution. At high energies, most of the measured background is nicely reproduced; at low energy some non-explained components are still present, although some plausible background sources have been analyzed. The {sup 40}K content of the NaI(Tl) crystal has been confirmed to be the dominant contributor to the measured background with this detector. In addition, preliminary results of the background characterization, presently underway at the LSC, of two recently produced NaI(Tl) detectors, with 12.5 kg mass each, will be presented: cosmogenic induced activity has been clearly observed and is being quantified, and {sup 40}K activity at a level ten times lower than in ANAIS-0 has been determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ranchero Armature Test LA-43-CT-2: PBXN-110 Explosive with no smoothing layer. Lower Slobovia, 6/13/13

This test, documented as LA-43-CT-2, was performed to verify calculations which indicate that the smoothing layer employed for Ranchero Armatures is not required when the slapper point spacing is 18 mm (“On the efficacy of an acrylic layer in the Ranchero armature,” Bob Watt, published in “Ranchero Status Report” LA-14463). [Naming this test –CT-2 acknowledges the previous test performed during 1/11 as the initial test in the series, and we will refer to that test as LA-43-CT-1 in the future.] In addition, higher velocity is achieved when the volume occupied by the smoother is replaced by HE. Two framing cameras were used on the shot, and a 20 point PDV array was fielded to ascertain armature performance in specific conditions. The conclusions are that the armature is smooth enough, and the terminal velocity is increased from ~3.1 mm/μs to ~3.3 mm/μs. The armature tested had casting voids in the HE that were observed in pre-test inspections, and were expected to cause ruptures. (See Appendix 3 of the Ranchero Status Report.) Such “blowouts” were observed in all three locations identified in pre-shot inspection. In addition, ruptures occurred in locations having no pre-shot indication of a problem. These unpredicted blowouts have a difference in appearance from those typically seen. Further visual examination of the inspection radiographs do not reveal the cause, and that is a serious concern for future efforts with such castings. A path forward will include attempting to digitize the inspection x-rays for the charge tested, to see if the cause of the “new” ruptures can be found via computer enhancement. In addition, there are two additional armatures from the same casting lot, and these might also be tested to see if there is some problem with the HE or the armature material in this batch. For now, this plan is on hold, pending the outcome of tests and cost estimates related to using PBX-9501 in place of the PBXN-110. Casting issues would be eliminated in such configurations.

42 ENGINEERING↗

TH-AB-202-07: Radar Tracking of Respiratory Motion in Real Time

Purpose: To propose a method of real time tracking of respiratory motion in patients undergoing radiation therapy. Radar technology can be employed to detection the movement of diaphragm and thoracic anatomy. Methods: A radar transceiver was specially designed. During experiment, the radar device was securely attached to a fixed frame. Respiratory motion was simulated with: 1) Varian RPM phantom, 2) Standard Imaging Respiratory Gating Platform. Signals recorded with radar equipment were compared with those measured with Varian RPM system as a reference. Results: Motion generated by Varian RPM phantom was recorded by the radar device, and compared to the signals recorded by RPM camera. The results showed exact agreement between the two monitoring equipments. Motion was also generated by Standard Imaging Respiratory Motion Platform. The results showed the radar device was capable of measuring motion of various amplitudes and periods. Conclusion: The proposed radar device is able to measure movements such as respiratory motion. Compared to state-of-the-art respiratory detection instrument, the radar device is shown to be equally precise and effective for monitoring respiration in radiation oncology patients.

60 APPLIED LIFE SCIENCES↗

TH-CD-207A-02: Implementation of Live EPID-Based Inspiration Level Assessment (LEILA) for Deepinspiration Breath-Hold (DIBH) Monitoring Using MV Fluoroscopy

Purpose: As prior work has shown that current DIBH monitoring approaches using surrogate measures (marker block on chest) do not always correspond with the clinical quantity of interest (lung depth, LD), a software tool and workflow are introduced to use MV fluoroscopy during treatment for real-time / Live EPID-based Inspiration Level Assessment (LEILA). Methods: A prototype software tool calculates and displays the LD during the treatment of left sided breast cancer. Calculations are based on MV cine images which are acquired with the treatment beam thereby not incurring any additional imaging dose. Image capture and processing are implemented using a dedicated frame grabber computer. The calculation engine automatically detects image orientation and includes provisions for large treatment fields that exceed the size of the EPID panel. LD is measured along a line profile in the middle of the field. LEILA’s interface displays the current MV image, a reference image (DRR), the current LD, as well as a trace of LD over treatment time. The display includes patient specific LD tolerances. Tolerances are specified for each field and loaded before the treatment. A visual warning is generated when the tolerance is exceeded. LEILA is initially run in parallel with current DIBH techniques. When later run by itself DIBH setup will be done using skin marks and room laser. Results: Offline tests of LEILA confirmed accurate automatic LD measurement for a variety of patient geometries. Deployment of the EPID during all left sided breast treatments was well tolerated by patients and staff during a multi-month pilot. The frame grabber provides 11 frames-per-second; the MATLAB based LEILA prototype software can analyze five frames-per-second standalone on standard desktop hardware. Conclusion: LEILA provides an automated approach to quantitatively monitor LD on MV images during DIBH treatment. Future improvements include a database and further speed optimization.

60 APPLIED LIFE SCIENCES↗

A CLOSE-PAIR ANALYSIS OF DAMP MERGERS AT INTERMEDIATE REDSHIFTS

We have studied the kinematics of {approx}2800 candidate close-pair galaxies at 0.1 < z < 1.2 identified from the Canada-France-Hawaii Telescope Legacy Survey fields. Spectra of these systems were obtained using spectrometers on the 6.5 m Magellan and 5 m Hale telescopes. These data allow us to constrain the rate of dry mergers at intermediate redshifts and to test the 'hot halo' model for quenching of star formation. Using virial radii estimated from the correlation between dynamical and stellar masses published by Leauthaud et al., we find that around 1/5 of our candidate pairs are likely to share a common dark matter halo (our metric for close physical association). These pairs are divided into red-red, blue-red, and blue-blue systems using the rest-frame colors classification method introduced in Chou et al.. Galaxies classified as red in our sample have very low star formation rates, but they need not be totally quiescent, and hence we refer to them as 'damp', rather than 'dry', systems. After correcting for known selection effects, the fraction of blue-blue pairs is significantly greater than that of red-red and blue-red pairs. Red-red pairs are almost entirely absent from our sample, suggesting that damp mergers are rare at z {approx} 0.5. Our data support models with a short merging timescale (<0.5 Gyr) in which star formation is enhanced in the early phase of mergers, but quenched in the late phase. Hot halo models may explain this behavior, but only if virial shocks that heat gas are inefficient until major mergers are nearly complete.

79 ASTRONOMY AND ASTROPHYSICS↗

Toward a new description of triaxial nuclei

The liquid drop Hamiltonian is amended with a potential which allows us to separate, in the intrinsic frame, the equations for {beta} and {gamma} coordinates. The Schroedinger equation for {beta} is that for a sextic oscillator plus a centrifugal term, while that for {gamma} is just the equation for the Mathieu function. The total energy has a compact form. The operator for the electric quadrupole transitions is considered in the intrinsic frame and involves two parameters accompanying the harmonic and anharmonic components. The parameters determining the energies as well as those defining the transition operator are to be determined by a fitting procedure. Applications refer to five isotopes: {sup 188}Os, {sup 190}Os, {sup 192}Os, {sup 228}Th, and {sup 230}Th. Results are in good agreement with the corresponding experimental data. Results are also compared with those obtained within the coherent state model. A possible connection between the two formalisms is pointed out.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Submillimeter observations of CLASH 2882 and the evolution of dust in this galaxy

Two millimeter observations of the MACS J1149.6+2223 cluster have detected a source that was consistent with the location of the lensed MACS 1149-JD galaxy at z = 9.6. A positive identification would have rendered this galaxy as the youngest dust forming galaxy in the universe. Follow up observation with the AzTEC 1.1 mm camera and the IRAM NOrthern Extended Millimeter Array (NOEMA) at 1.3 mm have not confirmed this association. In this paper we show that the NOEMA observations associate the 2 mm source with [PCB2012] 2882,{sup 12} source number 2882 in the Cluster Lensing And Supernova survey with Hubble (CLASH) catalog of MACS J1149.6+2223. This source, hereafter referred to as CLASH 2882, is a gravitationally lensed spiral galaxy at z = 0.99. We combine the Goddard IRAM Superconducting 2-Millimeter Observer (GISMO) 2 mm and NOEMA 1.3 mm fluxes with other (rest frame) UV to far-IR observations to construct the full spectral energy distribution of this galaxy, and derive its star formation history, and stellar and interstellar dust content. The current star formation rate of the galaxy is 54μ{sup −1} M{sub ⊙} yr{sup −1}, and its dust mass is about 5 × 10{sup 7}μ{sup −1} M{sub ⊙}, where μ is the lensing magnification factor for this source, which has a mean value of 2.7. The inferred dust mass is higher than the maximum dust mass that can be produced by core collapse supernovae and evolved AGB stars. As with many other star forming galaxies, most of the dust mass in CLASH 2882 must have been accreted in the dense phases of the interstellar medium.

79 ASTRONOMY AND ASTROPHYSICS↗

On-the-fly generation of differential resonance scattering probability distribution functions for Monte Carlo codes

Current Monte Carlo codes use one of three models to model neutron scattering in the epithermal energy range: (1) the asymptotic scattering model, (2) the free gas scattering model, or (3) the S({alpha},{beta}) model, depending on the neutron energy and the specific Monte Carlo code. The free gas scattering model assumes the scattering cross section is constant over the neutron energy range, which is usually a good approximation for light nuclei, but not for heavy nuclei where the scattering cross section may have several resonances in the epithermal region. Several researchers in the field have shown that using the free gas scattering model in the vicinity of the resonances in the lower epithermal range can under-predict resonance absorption due to the up-scattering phenomenon. Existing methods all involve performing the collision analysis in the center-of-mass frame, followed by a conversion back to the laboratory frame. In this paper, we will present a new sampling methodology that (1) accounts for the energy-dependent scattering cross sections in the collision analysis and (2) acts in the laboratory frame, avoiding the conversion to the center-of-mass frame. The energy dependence of the scattering cross section was modeled with even-ordered polynomials to approximate the scattering cross section in Blackshaw's equations for the moments of the differential scattering PDFs. These moments were used to sample the outgoing neutron speed and angle in the laboratory frame on-the-fly during the random walk of the neutron. Results for criticality studies on fuel pin and fuel assembly calculations using these methods showed very close comparison to results using the reference Doppler-broadened rejection correction (DBRC) scheme. (authors)

97 MATHEMATICS AND COMPUTING↗

TH-E-17A-10: Markerless Lung Tumor Tracking Based On Beams Eye View EPID Images

Purpose: Dynamic tumor tracking or motion compensation techniques have proposed to modify beam delivery following lung tumor motion on the flight. Conventional treatment plan QA could be performed in advance since every delivery may be different. Markerless lung tumor tracking using beams eye view EPID images provides a best treatment evaluation mechanism. The purpose of this study is to improve the accuracy of the online markerless lung tumor motion tracking method. Methods: The lung tumor could be located on every frame of MV images during radiation therapy treatment by comparing with corresponding digitally reconstructed radiograph (DRR). A kV-MV CT corresponding curve is applied on planning kV CT to generate MV CT images for patients in order to enhance the similarity between DRRs and MV treatment images. This kV-MV CT corresponding curve was obtained by scanning a same CT electron density phantom by a kV CT scanner and MV scanner (Tomotherapy) or MV CBCT. Two sets of MV DRRs were then generated for tumor and anatomy without tumor as the references to tracking the tumor on beams eye view EPID images. Results: Phantom studies were performed on a Varian TrueBeam linac. MV treatment images were acquired continuously during each treatment beam delivery at 12 gantry angles by iTools. Markerless tumor tracking was applied with DRRs generated from simulated MVCT. Tumors were tracked on every frame of images and compared with expected positions based on programed phantom motion. It was found that the average tracking error were 2.3 mm. Conclusion: This algorithm is capable of detecting lung tumors at complicated environment without implanting markers. It should be noted that the CT data has a slice thickness of 3 mm. This shows the statistical accuracy is better than the spatial accuracy. This project has been supported by a Varian Research Grant.

60 APPLIED LIFE SCIENCES↗

Evolution of intermittent filaments in the scrape-off layer of NSTX

Filamentary structures naturally arise from background turbulence in the scrape-off layer (SOL) of plasmas, leading to significant particle and heat transport that can degrade overall plasma confinement. This enhanced transport can contribute to unacceptably high heat loads on plasma-facing components. As such, understanding the physics of SOL plasma filaments is critical for predicting and mitigating their effects in future fusion devices. On the National Spherical Torus Experiment (NSTX), plasma filaments—commonly referred to as “blobs”—were investigated using the gas-puff imaging (GPI) diagnostic in the edge and SOL regions. The analysis involved identifying, segmenting, and tracking the characteristic contours of the blobs in each frame of the GPI video sequences. Their evolution was characterized through shape descriptors, velocity, and angular velocity derived from their contour coordinates. The results indicate that as the blob area increases, their shapes become more concave and less circular, suggesting reduced structural stability in larger blobs. This result aligns with previous theoretical results where it was shown that larger blobs are more susceptible to instabilities [Krasheninnikov et al., J. Plasma Phys. 74, 679–717 (2008) and D'Ippolito et al., Phys. Plasmas 18, 060501 (2011)]. A positive correlation was observed between radial velocity and radial position, suggesting radially outward acceleration of the filaments, potentially driven by decreasing viscous drag toward the far SOL. Interestingly, blobs in background SOL turbulence exhibited minimal spinning in contrast to filaments originating from edge localized modes, which show substantial rotation during their paths [Lampert et al., Phys. Plasmas 29, 102502 (2022)]. Statistical analysis of the solidity and total curvature shape descriptors, along with their temporal evolution, revealed relatively broad, near-Gaussian distributions. This suggests that blob morphology is strongly influenced by stochastic turbulent processes in the surrounding plasma environment. Blob parameters were also compared with bulk plasma and radial profile measurements. Notable trends were found between blob rotation and poloidal velocity with collisionality and line-integrated density. These findings contribute to a deeper understanding of blob dynamics and provide valuable insights for refining SOL turbulence models.

Covariance and correlation↗

Measurement of inclusive jet production and nuclear modifications in pPb collisions at $\sqrt{s_{_\mathrm {NN}}} =5.02\,\mathrm{TeV} $

In this study, inclusive jet production in pPb collisions at a nucleon–nucleon (NN) center-of-mass energy of √ s NN = 5.02 TeV is studied with the CMS detector at the LHC. A data sample corresponding to an integrated luminosity of 30.1 nb -1 is analyzed. The jet transverse momentum spectra are studied in seven pseudorapidity intervals covering the range -2.0 < η CM < 1.5 in the NN center-of-mass frame. The jet production yields at forward and backward pseudorapidity are compared and no significant asymmetry about ηCM=0 is observed in the measured kinematic range. The measurements in the pPb system are compared to reference jet spectra obtained by extrapolation from previous measurements in pp collisions at √s = 7 TeV. In all pseudorapidity ranges, nuclear modifications in inclusive jet production are found to be small, as predicted by next-to-leading order perturbative QCD calculations that incorporate nuclear effects in the parton distribution functions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗