Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reducing heat load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Study of Mechanical Properties, Microstructure, and Residual Stresses of AISI 304/304L Stainless Steel Submerged Arc Weld for Spent Fuel Dry Storage Systems

The confinement boundaries of spent nuclear fuel (SNF) canisters are typically fusion welded. Welded microstructures, strain hardening, and residual stresses combined with a chemically aggressive, chloride-rich environment led to concerns that the welded canister may be susceptible to chloride-induced stress corrosion cracking (CISCC). A comprehensive understanding of the modification of stainless steel (SS) metallurgical and mechanical properties by fusion welding could accelerate the predictive analysis of CISCC susceptibility. This paper describes a submerged arc welding (SAW) procedure that was developed and qualified on 12.7 mm (0.5 in.) thick AISI 304/304L SS to produce joints in a way similar to actual SNF canister manufacturing. This procedure has the potential to reduce the production cost and weld CISCC susceptibility by using fewer welding passes and lower heat input than current industrial applications. Global and local mechanical behaviors and properties, as well as residual stress distributions on the welded joint, were studied. The results indicate that hardness values in the fusion zone (FZ) and heat-affected zone (HAZ) are slightly higher than that of the base metal. Strain localization was presented in the HAZ before the tensile stress reached its maximum value, and then it shifted to the FZ. The specimen finally broke in the FZ. High tensile residual stresses exhibited in the FZ and the nearby HAZ suggest the highest CISCC-susceptible spots. The maximum tensile residual stresses were along the welding direction, indicating that if cracks occur, they would be perpendicular to the welding direction. This study involved developing and qualifying a SAW procedure for SNF canister production. The new procedure yielded cost savings (SAW working efficiency increased by about 80%), improved mechanical properties, and presented moderate residual stresses. Analysis revealed that the welded joint’s low-stress and high-stress damage assessments may be affected by shifts in the strain localization spot under loading.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sample problems for Section III, Division 5 design by inelastic analysis of Grade 91 components

This report works through two sample design analyses of representative Grade 91 components using the ASME Boiler & Pressure Vessel Code Section III, Division 5, Appendix HBB-T rules for the strain and deformation and creep-fatigue design criteria using a design by inelastic analysis approach. The component geometries and loadings were selected to span a wide variety of potential applications. The sample components are an endplate geometry, which is fairly representative of typical pressure vessel construction, and a core block, representing a critical component in a heat pipe microreactor, which has a complicated geometry and complex thermal stress history. These sample problems serve several functions. First, they are complete worked examples of how to apply the current design by inelastic analysis rules. Second, they serve as test cases to evaluate the current rules and provide feedback on how they could be optimized to deal with complicated component geometries or to be better automated in modern finite element analysis software. Finally, the analysis here uses an inelastic constitutive model for Grade 91 developed by Argonne National Laboratory and proposed for inclusion in the ASME Boiler & Pressure Vessel Code Section III, Division 5 rules as a reference constitutive model. Using this constitutive model in the sample problem analyses tests the model in the context of the ASME Code rules. The final conclusions of this report are that the material model and the current Code rules are satisfactory, but that the Code rules could be optimized to simplify automation and reduce over conservatism. Future work should address the specific optimization topics discussed in this report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancing building energy performance by effectively using phase change material and dynamic insulation in walls

Deploying phase change materials (PCMs) in building envelopes can be efficacious in reducing space heating/cooling loads and providing load shedding and shifting capacity. However, the full potential of PCM-integrated envelopes can only be harnessed if the PCM undergoes phase change using free ambient heating/cooling, and the stored energy is effectively transferred between the exterior and the interior environments. Traditional thermal insulation (with a fixed thermal resistance) limits PCM utilization, which restrains the energy saving potential of a PCM-integrated envelope to a small percentage. Proposed dynamic insulation material and system (DIMS) provides the option of varying its thermal resistance based on the indoor and outdoor conditions. Although it has been established that employing PCM as well as DIMS in building envelopes separately improves buildings’ energy performance, no prior studies that analyzed the combined influence of both technologies were identified. In this study, we examine a novel wall design, comprising a layer of PCM between two layers of DIMS. We note that the PCM-DIMS-integrated wall provides significantly higher energy saving potential than the DIMS-only integrated wall or the PCM-only integrated wall in all the climates and wall orientations analyzed in this study. Depending on the climate, the PCM-DIMS-integrated wall could provide 15–72% reduction in annual heat gain and 7–38% reduction in annual heat loss. The analysis presented in this study supports the need to develop scalable dynamic insulations combined with thermal energy storage systems for buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analyzing the Impact of Future Weather Data on Energy Consumption in Weatherization Assistant

This study supports the mission of the U.S. Department of Energy’s Weatherization Assistance Program (WAP), which aims to increase the energy efficiency of dwellings and reduce their total residential expenditures. Specifically, we examine how projected future climate conditions may affect residential building energy performance by integrating future weather data into the National Energy Audit Tool (NEAT). Since WAP evaluates the cost-effectiveness of retrofit measures over lifespans of up to 30 years, accounting for evolving climate conditions is increasingly important. To reflect future household energy demands, this study replaces historically based Typical Meteorological Year (TMY3) weather inputs with Future Typical Meteorological Year (fTMY) datasets derived from global climate model (GCM) projections. A simulation-based framework was established to enable NEAT analysis under future weather conditions. This workflow involves converting EPW-format weather files into JSON inputs compatible with NEAT and generating degree-hour metrics needed for load calculations. The fTMY dataset used in this study was developed by Oak Ridge National Laboratory through downscaling of six GCMs under different emission scenarios and covers the period from 2020 to 2100. In contrast, the TMY3 dataset is based on historical weather data from 1961 to 1990. Simulations were conducted for benchmark single-family prototype buildings across ASHRAE climate zones 1–7, which cover all regions of the U.S. except the subarctic Zone 8 in northern Alaska, evaluating both heating and cooling loads under TMY3 and fTMY conditions. Four foundation types were tested, while heating systems were standardized, as NEAT does not differentiate thermal energy load by HVAC system type in its load calculations. Results show that fTMY weather input consistently yield lower heating loads and higher cooling loads across most locations, aligning with expected climate warming trends. Notably, colder regions such as zones 6A, 6B, and 7 experience marked reductions in heating load, while warmer and transitional zones, such as 2A (Lufkin, TX) and 3C (San Francisco, CA), have substantial increases in cooling loads. Although this study does not directly assess the performance of retrofit measures under future climate conditions, it provides a critical foundation for doing so. By quantifying shifts in baseline (i.e., pre-retrofit case) energy loads between historical and future weather files, the study highlights the importance of integrating climate-responsive data into audit tools. These findings will inform future efforts to evaluate the long-term effectiveness and cost-effectiveness of weatherization measures under changing climate conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Requirements for Integration of Nuclear Reactors with Iron and Steel Plants

This report identifies energy needs of heavy energy users within the domestic iron and steel industry and suggests solutions for integrating nuclear energy. The iron and steel industry, composed of several types of plants which perform different processes with varied energy demands and vectors, is a heavy consumer of electric power and fossil fuels including coke and natural gas. Almost all major process temperatures exceed the temperatures of direct heat available from advanced reactors, and so electricity and hydrogen were considered instead. Reference units were adopted and estimated energy demands computed for the blast furnace (BF), direct reduced iron (DRI) unit, electric arc furnace (EAF), and reheat furnaces. By utilizing production capacity data from industry reports, the ranges of power demands were estimated, including for hydrogen production by high temperature steam electrolysis (HTSE). For the EAF and DRI unit, more detailed integration studies with thermodynamic modeling were also conducted and determined a possible solution with a specific reactor design and number of modules. Furthermore, because many unit processes are co-located, entire plants were considered by adding the energy demands of the unit processes to form four hypothetical reference plants. The range of power needs for the reference plants is compatible with multi-unit banks of microreactors at the low end, and would create a need for multiple larger-capacity SMRs at the high end (1 GWe plus 0.14 GWt). Although the overall power need at the high end is well-matched with one present-day large reactor offering (1.1 GWe), redundancy considerations may require a minimum of two reactors, potentially eliminating the single large reactor from consideration. Auxiliary or house loads would increase the reference plant estimates. Finally, the report provides total estimated energy needs under integration of all U.S. units of each process (BF, DRI, EAF, and reheat furnaces), representing a national potential for nuclear energy in the industry. U.S. iron and steel plants may be candidates for integration with nuclear reactors via electricity and hydrogen, and many sites have energy requirements that correspond well to the capacities of several advanced nuclear power designs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Computational analysis of flame initiation, quenching, and re-ignition in a prechamber natural gas engine under varying EGR-dilution levels

The on-road natural-gas (NG) fueled transportation relies on stoichiometric spark-ignition engines for the advantages of simple after-treatment system despite the efficiency penalty relative to lean-burn combustion strategies. Exhaust gas recirculation (EGR) has the potential to reduce this efficiency gap at low to moderate loads without the need for complex lean-exhaust aftertreatment systems. However, EGR dilution leads to reduced combustion stability and increased cycle-to-cycle variability. A promising technology that has the potential to achieve reliable operation under diluted conditions is the prechamber ignition (or turbulent jet ignition) which uses chemically active turbulent jets generated from combustion inside a prechamber to initiate, stabilize and accelerate combustion of the mixture inside the main chamber. The present work focusses on developing a RANS-based CFD approach to accurately reproduce in-cylinder phenomena in a stoichiometric NG prechamber-assisted heavy-duty engine without relying on complex combustion models that account for turbulence-chemistry interactions. This is necessary because reactive prechamber jets at high EGR dilution tend to extinguish while emerging into the main chamber, which is followed by a phase of re-ignition — a phenomenon that conventional G-equation or well-stirred reactor combustion models cannot reproduce. With addition of a damping multiplier to the well-stirred reactor model, the predictions are seen to show good agreement with experimental pressure evolution and combustion images acquired from a single cylinder Cummins N-14 optical diesel engine retrofitted with a prechamber ignition system. Model predictions of local heat release in the flame and temperature evolution inside the flame are used to investigate combustion dynamics in the prechamber and the main chamber. It is seen that the well-stirred reactor model with the inclusion of damping is able to reproduce the temporary reduction in heat release within the flame, which can be considered equivalent to quenching of jets, and the subsequent re-ignition of the flame inside the main chamber. The delay between quenching and re-ignition depends on the amount of dilution, as explained by an illustration of flame evolution in a Borghi diagram.

Prechamber ignition↗

Leak detection in a subcritical boiler

Thermal power plants experience cycling duty leading to the fatigue of the boiler and heat exchanger tubes. As a result, tube failures occur frequently in coal fired fleets leading to forced outages. Furthermore, because the tube leaks have been the major source of unwanted shutdowns and the number of outages is increasing, present work focuses on the detection and isolation of the leak in a subcritical boiler based upon the process data from a commercial coalfired power plant. The mass balance equation around the steam drum was analyzed using timeseries data collected from a 300 MW power plant. The ratio of the feed water mass flow rate to the steam mass flow rate was defined as a key parameter for detecting leaks. The difference in slope between the feedwater and steam mass flow rate during the normal and faulty operations was established as the upper control limit for real time monitoring. To reduce false alarm rates that arise when raw signal is directly compared against the threshold due to common process fluctuations, an optimal filter was derived for smoothing. It was found that the optimal filter reacted much more quickly to process changes than an exponential moving average filter, around 8 h earlier on average. Occurrence of relatively high false alarm rates even in the filtered responses was related to the cycling of the boiler from the base load condition. Variable threshold was established to keep false alarm rates to the minimum while maintaining the leak detection rate. Finally, the leak was located at the economizer and this could readily be isolated by investigating the magnitude of the mass flow rates ratio and the temperature at the economizer outlet.

42 ENGINEERING↗

Energy burden aware and thermal resilience informed thermal energy storage system planning for disadvantaged communities

Disadvantaged communities often face a disproportionate energy burden because they need to allocate a higher percentage of their income to energy costs. More importantly, climate change-induced extreme weather events, such as heat waves and severe cold snaps, exacerbate these communities’ energy burdens. As a result, low- and medium-income communities are more likely to experience energy supply disruptions, increased health risks, and elevated energy bills because of inadequate thermal insulation and airtightness in their houses. Thermal energy storage (TES) systems, such as large-scale (community-level) geothermal energy storage and small-scale (building-level) phase change material (PCM)–based storage, have a great potential to improve building energy efficiency and to enhance thermal comfort, load shifting, and integration with renewable energy. The objective of this study is to optimally allocate building level PCM-based TES systems at the community level by considering energy equity and extreme weather effects. To this end, we developed an energy burden and thermal resilience–informed TES system planning framework, which includes three modules: (1) a community-level energy burden and thermal resilience assessment module, (2) building-level a TES system integration and assessment module, and (3) a community-level optimal planning module. Case studies were conducted on four disadvantaged communities in Montgomery and Shelby Counties in Tennessee with energy burdens >10% and with high percentages of people of color. The results indicate that this comprehensive planning framework can assist disadvantaged communities in reducing their energy burden and in bolstering their resilience against the adverse effects of climate change.

Shen, Zhenglai↗

Experimental Characterization of Hydrocarbons and Nitrogen Oxides Production in a Heavy-Duty Diesel–Natural Gas Reactivity-Controlled Compression Ignition Engine

Reactivity-Controlled Compression Ignition (RCCI) combustion is considered one of the most promising Low-Temperature Combustion (LTC) concepts aimed at reducing greenhouse gases for the transportation and power generation sectors. Due to the spontaneous combustion of a lean, nearly homogeneous mixture of air and low-reactivity fuel (LRF), ignited through the direct injection of a small quantity of high-reactivity fuel (HRF), RCCI (dual-fuel) shows higher efficiency and lower pollutants compared to conventional diesel combustion (CDC) if run at very advanced injection timing. Even though a HRF is used, the use of advanced injection timing leads to high ignition delays, compared to CDC, and generates high cycle-to-cycle variability, limited operating range, and high pressure rise rates at high loads. This work presents an experimental analysis performed on a heavy-duty single-cylinder compression ignited engine in dual-fuel diesel–natural gas mode. The objective of the present work is to investigate and highlight the correlations between combustion behavior and pollutant emissions, especially unburned hydrocarbons (HC) and oxides of nitrogen (NOx). Based on the analysis of crank-resolved pollutants measurements performed through fast FID and fast NOx systems under different engine operating conditions, two correlations were found demonstrating a good accordance between pollutant production and combustion behavior: Net Cyclic Hydrocarbon emission—cyclic IMEP variations (R 2 = 0.86), and Cyclic NOx—maximum value of the Rate of Heat Released (R 2 = 0.82).

33 ADVANCED PROPULSION SYSTEMS↗

Scaling Demand Flexibility: Building on 30 Years of Energy Efficiency Success

With electricity consumption across the United States (US) and Canada anticipated to grow, energy efficiency program administrators have a key role to play in helping to ensure energy affordability and reliability in support of the broader economic systems utilities and grid support. Connected, demand side load balancing solutions, such as load shifting heating, ventilation and air conditioning (HVAC) systems and managed charging for electric vehicles (EVs), can dynamically manage energy, allowing for more volumetric electricity consumption without incurring the expense of upgraded transmission and distribution capabilities. When combined, or aggregated, many small loads can be managed to have meaningful impact on energy demand on the grid. Utilities and their partners have an opportunity to leverage decades of experience and the infrastructure needed to assess, design, implement, and measure programs to scale up the adoption of equipment with built-in load flexibility capabilities. Current efforts among a wide variety of electricity system service providers, utilities, standards agencies, regulators, national labs and private industry stakeholders aim to identify common standards, metrics, and methodologies for valuing grid services offered by demand side equipment. By combining those efforts with decades of proven energy efficiency resources, utilities are poised to effectuate a scaling up of equipment with energy management capabilities installed in homes and businesses across the US and Canada. This paper will provide an overview of how utilities are approaching this era of load growth and new peak demands across the United States and Canada. It will highlight the specific strategies that program administrators are employing to advance market transformation for grid-enabled products and devices that have the greatest potential to reduce energy use and increase load flexibility.

Grant, Peter↗

High Efficiency and Transient Air Systems for Affordable Load-Following Heavy Duty Truck Fuel Cells

Hydrogen fuel cell powered vehicles are one of the potential paths to reducing vehicle emissions. An important subsystem of the hydrogen fuel cell system is an air handling system that provides the needed oxygen (in air) to react with hydrogen in the fuel cell stack for electric power generation. Today’s systems use an electric motor to power an air compressor that supplies oxygen to the fuel cell stack. This process requires significant electrical power and is the largest parasitic power loss in hydrogen fuel cell vehicles. In addition to parasitic power loss, hydrogen fuel cell systems often have reliability issues associated with the air handling system. Reliability is of significant concern for heavy duty applications (especially long-haul applications). This project aims to improve both the electrical power consumption and reliability of hydrogen fuel cell air handling systems to meet the needs of heavy duty on-highway vehicle applications.

08 HYDROGEN↗

Open Building Control

Best practice control sequences are often not implemented correctly, or are not implemented at all, in large commercial buildings. This typically leads to 10-30 percent energy waste, along with reduced occupant productivity and unnecessary equipment wear. The current process of designing and implementing such control sequences is a manual process that starts with designers who often don’t have adequate training, then requires controls programmers to interpret and program a verbose written sequence. This process has been shown to fail to deliver high performance control sequences at scale. The Open Building Control project digitizes the current control delivery process. The project is developing tools for system designers to select control sequences, assess their energy performance and load flexibility potential using whole building simulation, specify the sequence for implementation using machine-to-machine translation by a control provider and formally testing the as-installed sequences by a commissioning agent. The project developed tools for each stage of this delivery process. The key innovation of the project is the development of the Control Description Language, a language that allows such a digitized control delivery process with end-to-end verification. Libraries of control sequences have been implemented using the Control Description Language, and their performance has been demonstrated using whole building energy simulation. An automated translation of such sequences to a commercial control product line has been conducted using a prototype translator. Tools for formal verification of as-installed control sequences relative to their specification have been developed and demonstrated. The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) started the process of forming a committee to make this language an ASHRAE/ANSI Standard. This new standard will complement existing and emerging ASHRAE standards for building communication and semantic modeling by providing a standard for expressing the control logic - the actual brain of the building. We expect this language and the process it enables to be an important contribution to the deployment of high performance building control sequences at scale because it allows taming the complexity of the control delivery process, which is continually increasing due to the need for higher performance and increased load flexibility to meet goals for net zero energy and increased renewable integration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Study of 120-volt Heat Pump Water Heaters in the Big Easy

To meet long-term goals for reducing carbon emissions and lessen the impacts of climate change, the U.S. plans to decarbonize its building stock, which includes the replacement of fossil fuel-burning end uses with energy efficient electric alternatives. As part of this strategy, the replacement of fossil fuel water heaters with heat pump water heaters (HPWH) has the potential to avoid substantial carbon emissions. An estimated 10-15 million single-family homes with fossil fuel water heaters do not have the electrical panel capacity to install a 240-volt, 30-amp HPWH. For these homes, a technology recently introduced to the market, the 120-volt plug-in HPWH, can provide energy efficient electrification of water heating without an expensive panel and wiring retrofit. This paper presents the results of an ongoing 120-volt HPWH field study conducted in 17 homes in New Orleans, LA. Key installation scenarios are profiled for retrofitting from gas-fired water heaters to 120-volt HPWHs, accounting for space, air volume, air temperature, condensate drainage, and electrical. Each HPWH had its surrounding air temperature, relative humidity, inlet and outlet water temperature, flow, and energy consumption monitored. Using these data, hot water delivery and energy efficiency performance were analyzed based on home characteristics. Hot water run outs were investigated to understand how hot water usage, inlet water temperature, and surrounding air temperature impact the HPWH’s ability to meet load. From these results, best practices for 120-volt HPWH siting, sizing, and installation were developed. In addition, results are explored further to add insight for electrification policies and product development.

heat pump water heater, 120-volt, Residential buil↗

Membrane Adsorbents Comprising Self-Assembled Inorganic Nanocages (SINCs) for Super-fast Direct Air Capture Enabled by Passive Cooling

The objectives of the proposed project were to develop highly porous membrane adsorbents comprising CO 2 -philic polymers and self-assembled inorganic nanocages (SINCs) for rapid temperature swing adsorption using electricity-free solar heating and radiative cooling, enabling an economically viable approach for direct air capture (DAC). Our core technical activities combine three key innovations. (1) Highly porous flat-sheet membrane adsorbents contain CO 2 -philic amines that can be easily produced using a phase inversion method. (2) CO 2 -philic SINCs can be easily dispersed in the polymers with great stability (compared with the metal-organic frameworks or MOFs). (3) The adsorption and desorption are integrated with solar heating and radiative cooling for rapid continuous operation, in contrast to traditional long-cycle separate operation. The membrane adsorbents containing amines, polymers, and SINCs were produced using a one-step industrial process. The porous membranes coupled with porous SINCs offer low resistance for gas flow and fast CO 2 sorption/desorption cycles, while the incorporation of the additional amine groups provides high CO 2 sorption capacity. The key achievements are summarized below. (1) Membrane adsorbents with high PEI loading (>40%), high porosity of >80%, and low gasflow resistance were prepared in one step using commercially available, low-cost materials. (2) Membrane adsorbents based on Solupor and PEI show CO 2 sorption capacity of >1.5 mmol/g using air containing 400 ppm at a relative humidity of 15%. (3) Effect of the adsorbent compositions (such as PEI type, PEI content, SINC content, porosity) on the CO 2 sorption was systematically investigated. (4) Effect of the processing conditions (such as CO 2 content, temperature, and relative humidity) on the CO 2 sorption was systematically investigated; (5) The stability of the membrane adsorption against many cycles of sorption and desorption was studied. The higher molecular weight of PEI (PEI25k) shows better stability than PEI800. (6) Advanced materials with radiative cooling were developed, which can decrease the temperature by 5-7 °C compared to the ambient temperature. (7) Preliminary techno-economic analysis shows that our process may achieve a capture cost of $1,343/tonne CO 2 with a total OPEX cost of $1,112/tonne CO 2 . The adsorbent replacement cost accounted for 52% of the total OPEX cost. Membrane adsorbents with lower costs and longer operation life can significantly decrease the cost. The proposed project directly addresses the requirement of DE-FOA-0002188, i.e., novel materials with CO 2 adsorption capacity for direct air capture with integrated solar heating and radiative cooling to reduce the cost of the DAC. Our future work will focus on the development of low-cost adsorbents that can be stable at the sorption and desorption conditions for long term.

14 SOLAR ENERGY↗

Transformative Efficiency and Automation in Modular Homes (TEAMH)

This report documents the Transformative Efficiency and Automation in Modular Homes (TEAMH) project, which evaluates the integration of advanced building envelope technologies and automation-assisted modular construction to improve residential energy performance and construction efficiency. The study investigates high-performance insulation systems, including vacuum insulation panels (VIPs), combined with light gauge steel (LGS) modular construction and factory automation. Laboratory testing, whole-building energy modeling across multiple climate zones, and factory demonstrations were conducted to assess thermal performance, energy savings, and production efficiency. Results indicate that upgraded envelope assemblies can achieve up to ~50% heating and ~34% cooling energy savings relative to IECC 2018 code-compliant homes, while automation-assisted construction can reduce wall assembly time by 24%–46% compared to conventional wood framing. The findings demonstrate the potential for scalable, high-performance modular homes that deliver significant energy savings with competitive projected costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of Thermal Expansion Coefficient, Viscosity and Melting Range in Simulation of PCM Embedded Heat Exchangers With and Without Fins

Phase change material heat exchangers (PCMHX) have an important role in integrating renewable energy systems. PCMHX can offer high storage density at various temperatures of interest and can be used for grid load shifting purposes. Numerical models enable engineers to estimate PCMHX performance for different design parameters and operating conditions. Modeling phase change phenomena is challenging due to the complex time-dependent nature of the process. The accuracy of models is highly sensitive to PCM thermo-physical properties. Thermal expansion coefficient (β), viscosity (μ) and melting temperature range (MR) of a PCM are important properties, especially when natural convection is not negligible. In PCMHX modeling, using less than accurate values for these properties can have significant impact on the simulation outcomes. These properties and discussions thereof are not readily available in the literature. This paper presents a brief review of the literature and a numerical study investigating the model sensitivity to the above-mentioned properties for PCMHX with and without fins. CFD is used to evaluate the charging (melting) phenomena. The study quantifies the impact of uncertainty in these properties on the melting rate and temperature profile. Constant wall temperature was considered as heat source with no heat loss to ambient. Here, the results show that β and μ has significant effect on the melting rate and evolution of the melting front. For a non-finned domain when comparing results for different published values of β and μ, the deviation in melting time can be up to 12.9% and 57.6% respectively. For high wall temperatures, change in melting range did not impact melting time. But when the wall temperature is reduced, up to 9.8% deviation in melting time is observed.

CFD↗

Designing Ceria/Alumina for Efficient Trapping of Platinum Single Atoms

Cerium oxide (ceria) has been shown to be very effective at trapping platinum atoms, due to formation of stable surface complexes at step edges, where coordinatively unsaturated cerium cations are present. But ceria loses its effectiveness when heated to high temperatures, due to loss of surface area and growth in particle size associated with sintering of the oxide. Being a rare-earth, and with limited supplies worldwide, it is important to develop methods to improve the effectiveness of ceria as a catalyst support. Here we explore the performance for trapping Pt atoms when the ceria is supported on a high surface area alumina carrier. This helps create a more sustainable catalyst formulation, especially if we can retain the high dispersion of Pt seen on ceria supports. For this work, we studied the atom trapping efficacy of ceria/alumina samples with increasing ceria content (8 wt% - 50%) and contrasted the behavior with pure ceria. Electron microscopy reveals that when dispersed on alumina, ceria is present in the form of crystalline nanoparticles as well as isolated cerium ions. These two forms of ceria differ markedly in their ability to trap Pt atoms. Atomically dispersed cerium is present in the form of Ce 3+ cations on alumina, however this form of ceria is not effective for trapping Pt atoms. Our results show that the atom trapped Pt resides primarily on crystalline ceria nanoparticles. CO oxidation was used as a probe reaction to evaluate the performance of these Pt AT /ceria-alumina catalysts. As a result, we conclude that over the range of ceria loadings we investigated, 50% ceria/alumina represents the optimal catalyst support for achieving high surface area and atom trapping efficiency while helping reduce the total ceria content in this catalyst system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗