At least 523 records · Page 29

Characterization data of an (AlFeNiTiVZr) 1-x Cr x multi-principal element alloy continuous composition spread library

The data provided in this article is related to the research article entitled “Phase stabilization and oxidation of a continuous composition spread multi-principal element (AlFeNiTiVZr) 1-x Cr x alloy”. This data article describes the high-throughput synthesis and characterization processes of an (AlFeNiTiVZr) 1-x Cr x alloy system. Continuous composition spread (CCS) thin-film libraries were synthesized by co-depositing an AlFeNiTiVZr metal alloy target and Cr target via magnetron sputtering. Post-processing was performed on the sample libraries with a vacuum anneal at 873 K and an air anneal at 873 K. Compositional data was determined via WDS in order to verify parameters provided by an in-house sputter model. Crystallographic data was captured via synchrotron diffraction and diffractograms were compared as a function of the change in Cr concentration. These measurements were taken in order to observe phase behavior after oxidation throughout the composition library. Furthermore, vibrational spectrographic data is provided of the oxidized library to show surface speciation along the composition gradient of the alloy system. The structural and oxidative behavior of the (AlFeNiTiVZr) 1-x Cr x alloy can be analysed using the data provided in this article. Additionally, this characterization dataset can be utilized in machine learning algorithms for determining important features and parameters for future hypothesis generation of functional multi-principal element alloys (MPEAs).

36 MATERIALS SCIENCE↗

TPCpp-10M: Simulated proton-proton collisions in a time projection chamber for AI foundation models

Scientific foundation models hold great promise for advancing nuclear and particle physics by improving analysis precision and accelerating discovery. Yet, progress in this field is often limited by the lack of openly available large scale datasets, as well as standardized evaluation tasks and metrics. Furthermore, the specialized knowledge and software typically required to process particle physics data pose significant barriers to interdisciplinary collaboration with the broader machine learning community. This work introduces a large, openly accessible dataset of 10 million simulated proton-proton collisions, designed to support self-supervised training of foundation models. To facilitate ease of use, the dataset is provided in a common NumPy format. In addition, it includes 70,000 labeled examples spanning three well defined downstream tasks: track finding, particle identification, and noise tagging, to enable systematic evaluation of the foundation model's adaptability. The simulated data are generated using the Pythia Monte Carlo event generator at a center of mass energy of $\sqrt{s}$ = 200 GeV and processed with Geant4 to include realistic detector conditions and signal emulation in the sPHENIX Time Projection Chamber at the Relativistic Heavy Ion Collider, located at Brookhaven National Laboratory. This dataset resource establishes a common ground for interdisciplinary research, enabling machine learning scientists and physicists alike to explore scaling behaviors, assess transferability, and accelerate progress toward foundation models in nuclear and high energy physics. The complete simulation and reconstruction chain is reproducible with the sPHENIX software stack. All data and code locations are provided under Data Accessibility.

Data Analysis, Statistics and Probability (physics↗

The connection between the chromatic numbers of a hypergraph and its 1-intersection graph

A well known problem from an excellent book of Lovász states that any hypergraph with the property that no pair of hyperedges intersect in exactly one vertex can be properly 2-colored. Motivated by this as well as recent works of Keszegh and of Gyárfás et al. we study the 1-intersection graph of a hypergraph. The 1-intersection graph encodes those pairs of hyperedges in a hypergraph that intersect in exactly one vertex. We prove for k ϵ {2, 4} that all hypergraphs whose 1-intersection graph is k-partite can be properly k-colored.

1-intersection graph of hypergraphs↗

The impact of capillary heterogeneity on CO 2 flow and trapping across scales

Capillary heterogeneity has been identified over the last decade as a key control on subsurface CO 2 flow behavior during geological CO 2 sequestration. These heterogeneities can be formed in all sedimentary rocks, ranging from slight variations in the sand grain sizes to extensive sequences of interbedded sands, shales, and limestones. Capillary heterogeneity has been largely, although not entirely, overlooked in subsurface flow modeling because it is assumed to only directly influence fluid redistribution over scales of centimeters to meters. However, even small-scale fluid movements can result in dramatic impacts on the mobility and trapping of the CO 2 over kilometers. Therefore, neglecting capillary heterogeneity at multiple scales could potentially lead to errors in modeling and predicting field-scale plume migration. In this review paper, we aim to provide a consistent overview to (1) establish that capillary heterogeneity can have a major impact on CO 2 plume migration, (2) establish the respective length scales at which capillary heterogeneity matters, and (3) provide guidance for numerical modeling. This review covers pertinent literature and extracts key observations from the core to the field scales. Experimental studies have shown that millimeter-decimeter scale capillary heterogeneity can cause the so-called capillary heterogeneity trapping in addition to pore-scale residual trapping. Even at such a small scale, capillary heterogeneity can already lead to complex upscaled constitutive relationships, such as flow-rate dependent and anisotropic relative permeability, which affects field-scale CO 2 migration even when field-scale heterogeneities are present. Under gravity-dominated flow regimes, centimeter-meter scale capillary heterogeneity can entrap a significant amount of CO 2 at field scale, not just after imbibition but also during drainage. In certain cases, the presence of capillary heterogeneity can even completely stop the vertical movement of the CO 2 plume, hence greatly reducing leakage risks. At meter-kilometer scale, the influence of capillary heterogeneity is more pronounced and can hinder or redirect CO 2 migration in both lateral and vertical directions. The impact of capillary heterogeneity across multiple spatial scales poses a great challenge in modeling CO 2 migration at field scale, because it is practically impossible to build a field-scale earth model with grid blocks at millimeter scale. We recommend a hierarchical modeling approach to address this challenge. At field scale, earth models are built to capture geological features and heterogeneities in high but still practical grid resolutions. For each facies or rock type of the field-scale model, high- resolution meter-scale “conceptual” models are built with millimeter-scale grid blocks to capture representative fine-scale bedding geometries and heterogeneities in various environments of deposition, bridging the gap from subcore scale to the size of a field-scale simulation grid block. Upscaling is then used to preserve the smaller-scale flow dynamics of various rock types in field-scale simulations. Here, future work is needed to (1) refine, improve, and validate the hierarchical modeling approach; (2) build libraries of fine-scale bedding models for facies in various environments of deposition; (3) quantify multiscale capillary heterogeneity effects under subsurface uncertainties; (4) gain learning from different storage formations; and (5) establish best practices that balance accuracy and computational speed.

Capillary heterogeneity↗

Effect of Cu on the passivity of Ti–xCu (x = 0, 3 and 5 wt%) alloy in phosphate-buffered saline solution within the framework of PDM-II

The effect of copper content on the passivity of Ti–xCu alloys in a phosphate-buffered saline electrolyte (pH 7.4), in the steady-state condition, was examined using potentiostatic polarization, electrochemical impedance spectroscopy, and Mott-Schottky analysis. The study demonstrates that the oxide layer forms on the Ti–xCu alloys surface have n-type semiconducting character, and the steady-state thickness of the oxide layer is observed linearly and depends on the applied potential. The study observations are in line with the predictions of the Point Defect Model (PDM-II), which provides a physiochemically realistic description of the oxide layer formation on Ti–xCu alloys. The observations reveal that the Cu additions result in a decrease in the charge transfer resistance and capacitances associated with the hydroxide and barrier layer, an increase in the donor density, and reduce the electrochemical resistance of the Ti–xCu alloys. The study also exhibits that the decrease in the steady-state current density after the initial addition of 3 wt% of Cu is attributed to the progressive substitution of copper on the cation sublattice of the film resulting in enhanced electrostatic interaction between the immobilized copper $Cu^{x'}_{Ti}$, and the mobile cation interstitials $Cu^{+}_{i}$, which carries the excess current over and that conveyed by oxygen vacancies $V^{••}_o$ in the barrier layer. Moreover, it is also observed that over a hundred-year implant period, about 0.006 cm (0.06 mm) of Ti–3Cu alloy is predicted to lose due to steady-state corrosion in the PBS solution under the given set of conditions, it is further seen that, as the Cu amount increased from 3 wt% to 5 wt% in the Ti–xCu alloys, the steady-state corrosion rate decreases.

Electrochemical Impedance Spectroscopy↗

Emulation and detection of physical faults and cyber-attacks on building energy systems through real-time hardware-in-the-loop experiments

The increasing use of remote or mobile access, integrated wearable technologies, data exchange, and cloud-based data analytics in modern smart buildings is steering the building industry towards open communication technologies. The increased connectivity and accessibility could lead to more cyber-attacks in smart buildings. On the other hand, physical faults (e.g., HVAC -heating, ventilation, and air-conditioning faults) may have similar adverse impacts as those from the cyber-attacks on building energy systems, such as occupant discomfort, energy wastage, and equipment downtime. However, current physical behavior-based anomaly detection methods fail to differentiate between cyber-attacks and physical faults in building energy systems. Moreover, the challenge in collecting real-world threat data with ground truth has led researchers to rely on numerical models with user-defined assumptions, which may not accurately reflect real-world conditions due to the lack of in-situ experimental datasets. To address these challenges and gaps, this paper presents a flexible hardware-in-the-loop (HIL) testbed for generating cyber-attack and physical fault datasets and demonstrating threat detection algorithms in a real building automation system (BAS) environment. This testbed combines hardware (i.e., real BAS with local HVAC controllers and a physical network) with software (i.e., high-fidelity models to represent behaviors of building envelope and HVAC energy systems), enabling emulations of realistic threats. Five HIL experiments, including one baseline without any threats, two with physical faults, and two with cyber-attacks, were conducted to generate datasets containing detailed network traffic and system states. A joint classification framework, incorporating a network analyzer and a physical HVAC fault detector, was proposed to automatically detect cyber-physical abnormalities on BAS at both the network and the physical HVAC levels. The network analyzer comprises a conditional random fields (CRF) based command validator and a statistics-based detection strategy. The fault detector employs a weather and schedule-based pattern matching and feature-based principal component analysis (WPM-FPCA) method. Evaluation of the classification using four metrics from the multi-class confusion matrix revealed an average accuracy of 90.2%, recall of 89.7%, precision of 88.5% and F1-score of 89.2%. Finally, these results demonstrate that the proposed joint classification framework can effectively differentiate between specific types of cyber-attacks (e.g., device reinitialization attack, network Denial-of-Service attack) and physical faults (e.g., air handling unit operational fault, cooling coil valve stuck) in real time for improved building energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Maximizing oil production from water alternating gas (CO 2 ) injection into residual oil zones: The impact of oil saturation and heterogeneity

Residual oil zones (ROZs) are widespread reservoirs, characterized by oil at residual saturation, either underlying oil fields (brownfield) or lateral (greenfield) to such fields. These reservoirs have the potential to produce volumes of oil sufficiently significant to make appreciable impacts on the US’s oil reserves and associated incidental CO 2 sequestration. The objective of this study is to improve our understanding the impact of heterogeneous and low oil saturations, in brownfield ROZs, on the effectiveness of water alternating gas (WAG) injection strategies. ROZs occur in the Permian Basin and elsewhere, and operators are using CO 2 injection for enhanced oil recovery (EOR) in these zones. The consensus model for the formation of ROZs is that they were formed by the effect of faster regional aquifer flow, acting over millions of years. Both the magnitude of oil saturation and the spatial distribution of oil differ from water-flooded main pay zones (MPZs). To explore the most effective injection strategies, we conducted simulations of CO 2 injection into synthetic geologic reservoirs. These simulations focused on injection into reservoirs subject to either man-made waterflooding or long-term natural waterflooding. By exploring the impact of varying: oil saturation; well patterns; reservoir heterogeneity; and permeability anisotropy, we attempt to quantify the factors that most influence the effectiveness of WAG injection. WAG ratios (the ratio of injected water and CO 2 , in reservoir volumes) of interest are those that either minimize the net CO 2 utilization ratios or maximize oil production rates. In general, the most effective WAG ratios for ROZs, are consistently less than those observed undergoing CO 2 injection in the same geologic reservoir models after traditional (man-made) waterflooding. This work demonstrates that most favorable WAG ratios for oil production in ROZs are different from those in traditional MPZs because of oil saturation differences. Therefore, CO 2 injection into both zones or directly copying WAG injection designs from MPZs to ROZs might not maximize oil production.

04 OIL SHALES AND TAR SANDS↗

Simulation and analysis of the 3D double shock-induced recompression of spall using a hybrid PAGOSA with FLIP+MPM

In this work, an innovative hybrid algorithm PAGOSA with FLIP + MPM is first presented by coupling PAGOSA with the particle FLIP + MPM, and applied to systematically exploring the 3D recompression of spall induced by double-shock waves in ductile materials as the few existing studies are currently limited to the pure longitudinal recompression of spall, and ignore the 3D effects. This algorithm solves the difficulties the grid-based methods encounter when applied to capturing the fracture in material. We first validate the capabilities of PAGOSA with FLIP + MPM to predict different fracture/fragmentation cases by solving two benchmark problems and comparing with the analytical solutions or the experiment results. The convergences and the infinity-norm errors are also investigated. Subsequently, the 3D effects are demonstrated by simulating the spallation in material using PAGOSA with FLIP + MPM and comparing with those in the longitudinal cases. Additionally, some factors that affect the spallation with 3D effects are also discussed. Finally, the recompressions of spall in material with/without 3D effects are systematically simulated and analyzed. The recompression of spall driven by a high explosive is also simulated to show the ability of PAGOSA with FLIP + MPM to handle this kind of problem. The conditions that can lead to a recompression of spall are explored. Also, numerical results show that PAGOSA with FLIP + MPM can accurately predict different fracture cases, that the 3D effects play an important role in fracture/fragmentation, and the recompression of spall is very sensitive to the occurrence conditions, shows great differences when considering 3D effects in real applications. Moreover, the present hybrid method can be easily extended to other grid-based techniques employed for fracture in materials.

3D effects↗

Regulated lithium ionic flux through well-aligned channels for lithium dendrite inhibition in solid-state batteries

The utilization of solid electrolyte (SE) to suppress lithium (Li) dendrites is promising but still far from satisfactory due to the inhomogeneous Li plating/stripping. In this paper, we demonstrated a novel strategy to inhibit Li dendrites via regulating Li-ion flux in SE by using vertically aligned channels. The ion-insulating walls facilitated uniform distribution of Li-ion flux through the channels, leading to a homogeneous Li deposition, thus alleviating Li dendrite formation. As a result, symmetric cells with this SE exhibited excellent long-term stability (1000 h) against Li metal. In addition, Li4Ti5O12 (LTO)/Li cell with the developed SE achieved good battery performance over 100 cycles. The mechanism for dendrite suppression was further investigated by phase-field simulation. This work provides a novel strategy by manipulating uniform Li-ion flux to fabricate SE to inhibit Li dendrites and facilitates the development of high-performance rechargeable Li batteries.

25 ENERGY STORAGE↗

Fluorination effect for stabilizing cationic and anionic redox activities in cation-disordered cathode materials

We see that cation-disordered Li-excess cathodes with oxygen redox reactions are promising candidates for high-energy-density Li ion batteries. Nevertheless, the oxygen redox process that is required for the high capacity often comes with the oxygen loss, which leads to severe capacity degradation and voltage decay. In this work, we have successfully synthesized a series of Li-excess cation-disordered cathodes (Li 1.2 Mn 0.4+x Ti 0.4-x O 2-x Fx) (0 ≤ x ≤ 0.2) with different fluorine (F) contents. The electrochemical performance results show that the Li 1.2 Mn 0.55 Ti 0.25 O 1.85 F 0.15 (LMTOF0.15) exhibits the highest reversible capacity (275 mAh g -1 , under 30 mA g -1 ), cyclability, and voltage retentions. The mapping of resonant inelastic X-ray scattering (mRIXS) and differential electrochemical mass spectroscopy (DEMS) results reveal that the fluorination enhances the reversible lattice oxygen redox reaction while suppressing irreversible gas release and surface reactions. The X-ray Absorption Spectroscopy (XAS) during the initial two cycles shows that F-substitution alleviates the reduction of the Mn valence state during the whole (dis)charge processes in the bulk and at the surface of the material, results in higher average discharge voltage. In addition, the introduction of F improves the structural stability and suppresses local lattice distortion of the material. Therefore, LMTOF 0.15 is able to cycle with smaller polarization, less interfacial side reaction and Mn dissolution, and therefore results in enhanced cyclability. This work provides a comprehensive understanding of the fluorination effect on the cationic and anionic redox activities in cation-disordered Li-excess cathodes.

25 ENERGY STORAGE↗

Development of cathode-electrolyte-interphase for safer lithium batteries

Accompanied by the adoption of aggressive cathodes to continuously improve batteries energy density, enhancing their safety is becoming increasingly urgent for the electric vehicle development. In-situ controllable formation of robust cathode-electrolyte interphase (CEI) with high inorganic content seems to be the most promising strategy to address the thermal runaway concerns. Moreover, the in-situ formation strategy via suitable electrolyte replacement or electrolyte additives is extremely simple yet effective, especially for industrial manufacture of batteries. Here, this paper briefly reviews recent advanced CEIs formed by conventional carbonate-based electrolytes, fluorinated electrolytes, concentrated electrolytes, and solid state electrolytes. The focus on the thermal stability of the cathodes after CEI modification, and at the same time conduct safety tests at the material, cell, and module levels for comprehensive evaluation are encouraged. The review will provide inspiration for future developments in battery safety and push forward the practical applications of newly developed high-energy density batteries.

25 ENERGY STORAGE↗

Revisiting the initial irreversible capacity loss of LiNi 0.6 Co 0.2 Mn 0.2 O 2 cathode material batteries

Layered LiNi 0.6 Co 0.2 Mn 0.2 O 2 (NCM622) attracts widespread attention primarily due to its potential for high energy density and moderate thermal stability. However, the low initial coulombic efficiency (ICE) of the material limits the maximum utilization of their capacity. The capacity loss in the first cycle occurs under 4.0V and keep almost constant are considered as common characteristics for NCM-based materials. A clear cognition on the initial capacity loss may light the way to improve the practical reversible capacity of NCM622 at 4.0V. Conducting operando X-ray diffraction during galvanostatic charge/discharge cycling at different temperature (25 degrees C, 45 degrees C and 60 degrees C) and different current (0.1C, 0.01C, 1C=120 mA g -1 ) in the voltage range of 2.7-4.0V, we find that only 8% of the measured initial irreversible capacity loss is associated with parasitic reactions that form cathode/electrolyte interface, and that the dominant contributors include the slow Li + diffusion kinetics (similar to 46% contribution) and irreversible O3/H1-3 phase transition (similar to 46% contribution). Finally, this semi-quantitative study provides new insight on initial capacity loss, guiding further targeted modification and fully utilization of NCM622.

25 ENERGY STORAGE↗

Constructing O2/O3 homogeneous hybrid stabilizes Li-rich layered cathodes

With the advantages of high energy density and low manufacture cost, lithium-rich layered oxides (LLOs), typically with a layered O3-type structure, are regarded as promising cathodes for lithium-ion batteries (LIBs), but their broad usages are hindered by severe voltage decay over cycling. Although recent progress in O2-type LLOs has aroused interest for their less voltage decay, the critical barrier of unsatisfactory capacity retention has not been overcome yet. In this work, to tackle these handicaps, we design a new type of LLO (O2/O3-type LLO) with a homogeneous hybrid structure, where the O2 and O3 lattice stacking sequences are arranged alternatively. Benefitting from this novel O2/O3 hybrid structure, the designed material shows greatly improved voltage and capacity stability than that of pure O2- and O3-type LLOs. Revealed by in-situ synchrotron X-ray diffraction and operando differential electrochemical mass spectra, the O2/O3-hybrid LLO cathode shows a more reversible structural evolution, smaller volume change and suppressed oxygen loss during the electrochemical processes. Our approach has initiated a new way to reduce the capacity and voltage decay of LLOs, which endows great promise to the development of high-energy-density LIBs.

25 ENERGY STORAGE↗

Opening twisted polymer chains for simultaneously high printability and battery fast-charge

Fast-charging is key to the widespread adoption of battery-based electric vehicles. However, improving fast-charging through architecture optimization is expensive. To reduce costs and expand to commercialization, we applied roll-to-roll screen printing technology to create channels and decrease the tortuosity of electrodes. For the first time, this work successfully opened twisted polymer chains within high-solid-content inks to improve their screen printability and battery performance of as-printed electrodes. With LiNi 0.6 Mn 0.2 Co 0.2 O 2 as active materials, the 60% solid content ink presents superior screen printability after opening the twisted binder chains. As-printed electrode exhibits 33% higher charge capacity at 6 C than printed electrode with chains twisted ink at mass loading of 6.5 mg/cm 2 . Furthermore, coarse-grained molecular dynamics simulations are performed to study the underlying mechanism systematically. In conclusion, the new ink preparation procedure provides a scalable, effective strategy for manufacturing screen-printable battery ink and promotes screen-printed electrode technology.

25 ENERGY STORAGE↗

Solid-state interphases design for high-safety, high-voltage and long-cyclability practical batteries via ethylene carbonate-free electrolytes

In this study, ethylene carbonate (EC) plays a crucial role in current electrolytes for batteries. However, EC reacts exothermically with the electrode to trigger thermal runaway and undergoes continuous oxidative decomposition at high voltages, hindering it application for next-generation batteries. Here we report a simple and effective strategy to design sulfolane(SL)-based electrolyte with reshaped anions-dominated solvation structure, forming highly stable inorganic-dominated electrode-electrolyte interphases that efficiently stabilize nickel-rich cathode and graphite anode. Compared with the conventional electrolyte, practical pouch-type LiNi 0.8 Co 0.1 Mn 0.1 O 2 |Graphite cell with SL-based electrolyte significantly improve self-generated heat T 1 and thermal runaway triggering T 2 by 9.6 and 42.0 °C, respectively. More surprisingly, the pouch cell with SL-based electrolyte exhibits outstanding capacity retention of 88 % after 1000 cycles charged up to 4.5 V. The study brings new insights for unlocking advanced electrolyte candidates to build next-generation practical safer high-energy batteries.

25 ENERGY STORAGE↗