Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

A cut cell method for the 3D simulation of Crookes radiometer

Devices involved in engineering applications, such as vacuum pumps or MEMS, may be made of several moving parts. This raise the issue of the simulation of rarefied gas flow around moving boundaries. We propose a simple process, known as cut cell method, to treat the motion of a solid body in the framework of the deterministic solving of a kinetic equation. Up to our knowledge, this is the first time that this approach has been used for this kind of simulations. The method is illustrated by the 2D and 3D simulations of a Crookes radiometer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Removing Biases from Rotating Shadowband Radiometers

Three types of biases are examined for a Rotating Shadowband Radiometer (RSR): temperature bias, spectral bias, and deviation from a Lambertian cosine response. A step by step method is presented to illustrate how to use this information to develop a model for adjustment algorithms for a RSR. Comparisons are made with a RSR adjusted using the model and measure direct normal, diffuse, and global irradiance.

14 SOLAR ENERGY↗

Improved Rotating Shadowband Radiometer Measurement Performance: Cooperative Research and Development Final Report, CRADA Number CRD-08-294

Under this Agreement, NREL will work with Participant to improve rotating shadowband radiometer (RSR) performance characterizations. This work includes, but is not limited to, research and development for making the RSR a more accurate and fully characterized instrument for solar power technology development and commercial solar power project site assessment. Cooperative R&D is proposed in three areas: instrument calibration, instrument field configuration and operation, and measurement extrapolation and interpolation using satellite images. This work will be conducted at NREL and Participant facilities.

14 SOLAR ENERGY↗

Microwave Radiometer Profiler (MWRP) Instrument Handbook

The Microwave Radiometer Profiler (MWRP) provides time-series measurements of brightness temperatures from 12 channels between 22.235 and 58.80 GHz. These channels are sensitive to the presence of liquid water and precipitable water vapor and to the atmospheric temperature and humidity profile.

47 OTHER INSTRUMENTATION↗

Broadband Outdoor Radiometer Calibration (BORCAL) Process for the Atmospheric Radiation Measurement (ARM) Program: Second Edition

The Atmospheric Radiation Measurement program (ARM) maintains a fleet of monitoring stations to aid in the improved scientific understanding of the basic physics related to radiative feedback processes in the atmosphere, particularly the interactions among clouds and aerosols. ARM obtains continuous measurements and conducts field campaigns to provide data products that aid in the improvement and further development of climate models. All of the measurement campaigns include a suite of solar measurements. The Solar Radiation Research Laboratory at the National Renewable Energy Laboratory supports ARM's full suite of stations in a number of ways, including troubleshooting issues that arise as part of the data-quality reviews; managing engineering changes to the standard setup; and providing calibration services and assistance to the full fleet of solar-related instruments, including pyranometers, pyrgeometers, pyrheliometers, as well as the temperature/relative humidity probes, multimeters, and data acquisition systems that are used in the calibrations performed at the Southern Great Plains Radiometer Calibration Facility. This paper discusses all aspects related to the support provided to the calibration of the instruments in the solar monitoring fleet.

14 SOLAR ENERGY↗

Solar Irradiances Measured using SPN1 Radiometers: Uncertainties and Clues for Development

The fast development of solar radiation and energy applications, such as photovoltaic and solar thermodynamic systems, has increased the need for solar radiation measurement and monitoring, not only for the global component but also the diffuse and direct. End users look for the best compromise between getting close to state-of-the-art measurements and keeping capital, maintenance and operating costs to a minimum. Among the existing commercial options, SPN1 is a relatively low cost solar radiometer that estimates global and diffuse solar irradiances from seven thermopile sensors under a shading mask and without moving parts. This work presents a comprehensive study of SPN1 accuracy and sources of uncertainty, which results from laboratory experiments, numerical modeling and comparison studies between measurements from this sensor and state-of-the art instruments for six diverse sites. Several clues are provided for improving the SPN1 accuracy and agreement with state-of-the-art measurements.

energy applications↗