Direct comparison of gamma, electron beam and X-ray irradiation doses on characteristics of low-density polyethylene, polypropylene homopolymer, polyolefin elastomer and chlorobutyl rubber medical device polymers

There is a growing need for increased efficiency in the sterilization of single use medical devices and other products that contain polymer components. Gamma radiation is widely used for devices suited for radiation sterilization; however, safety, throughput and cobalt-60 source availability are challenging the prospect of relying on gamma radiation to meet the anticipated needs of the industry. Use of electron beam (e-beam) and X-rays as alternatives to gamma for radiation sterilization have been hampered in part by a concern that these modalities may adversely affect polymer integrity and performance relative to the gamma method, for which the industry has had much more experience. To address this concern, the effects of sterilization-relevant doses of ebeam, X-ray and gamma radiation were directly compared using common medical device polymers found in two prototypical commercial devices currently sterilized using cobalt-60 gamma irradiation. The Becton, Dickinson and Company (BD) Vacutainer™ Plus tube contains low-density polyethylene and chlorobutyl rubber components, while the BD Vacutainer™ Push Button Blood Collection Set contains polypropylene homopolymer and polyolefin elastomer components. Injection-molded samples prepared from the polymers used in these products were exposed to target doses of 15, 35, 50 and 80 kGy using gamma, e-beam and X-ray radiation. Changes in coloration, tensile properties and hardness were measured for each condition, and the effects of e-beam and X-ray irradiation compared with the effects of gamma irradiation on these properties. Both e-beam and X-ray appear as viable alternatives to gamma irradiation for sterilization of the polymers tested.

sterilization, gamma, X-ray, electron beam, radiat↗

Electron Radiation-Induced Nickel Nanoparticle Formation in KCl-ZnCl 2 Eutectic Molten Salt Using X-ray Absorption Spectroscopy

Understanding the speciation and local structure of metal solutes in molten salts is essential for predicting thermal properties and the redox and corrosion potentials of molten salts for next-generation nuclear reactors and concentrated solar power plant applications. Here, we employ X-ray absorption spectroscopy combined with electron paramagnetic resonance (EPR) measurements to investigate the effects of electron irradiation on 0.1 wt % NiCl 2 dissolved in molten eutectic KCl-ZnCl 2 salt. Radiation-driven reduction of Ni 2+ leading to nucleation and growth of Ni nanoparticles is studied as a function of electron dose (3–15 MGy) and temperature. Quantitative X-ray absorption near edge structure and linear combination fitting are utilized to investigate the extent of reduction as a function of the electron dose and temperature. A multiple-scattering (MS) approach is used for extended X-ray absorption fine structure analysis to deduce the size of the Ni nanoparticles formed and to understand the effect of the dose on the local structure of the nanoparticles. EPR studies on solidified NiCl 2 dissolved in molten eutectic KCl-ZnCl 2 salt show the formation of magnetic Ni nanoparticles.

36 MATERIALS SCIENCE↗

O-Mode Instability for Non-Thermal Continuum Radiation Generated Near the Plasmapause

Analysis of the ordinary mode (O-mode) instability is performed to comprehend the nonthermal continuum (NTC) radiation near the plasmapause, taking into account the relativistic wave-electron resonance effect. The energy source is the anisotropy in the velocity of the minority suprathermal electron population. Numerical solutions demonstrate that the O-mode can be unstable with multiple narrow frequency bands located close to harmonics of the electron cyclotron frequency above the local electron plasma frequency. These waves have narrow beaming angle bands of nearly 90° relative to the ambient magnetic field. Our findings indicate that NTC radiation generated by this wave-electron resonance instability near the plasmapause can propagate nearer to the magnetic equator with multiple harmonics, which is in agreement with a recent statistical study using Van Allen Probes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of X-Rays, Electron Beam, and Gamma Irradiation on Chemical and Physical Properties of EVA Multilayer Films

Gamma-ray irradiation, using the cobalt-60 isotope, is the most common radiation modality used for medical device and biopharmaceutical products sterilization. Although X-ray and electron-beam (e-beam) sterilization technologies are mature and have been in use for decades, impediments remain to switching to these sterilization modalities because of lack of data on the resulting radiation effects for the associated polymers, as well as a lack of education for manufacturers and regulators on the viability of these sterilization alternatives. For this study, the compatibility of ethylene vinyl acetate (EVA) multilayer films with different ionizing radiation sterilization (X-ray, e-beam, and gamma irradiation) is determined by measuring chemical and physical film properties using high performance liquid chromatography, differential scanning calorimetry, Fourier-Transform InfraRed spectroscopy (FTIR), surface energy measurement, and electron spin resonance techniques. The results indicate that the three irradiation modalities induce no differences in thermal properties in the investigated dose range. Gamma and X-Ray irradiations generate the same level of reactive species in the EVA multilayer film, whereas e-beam generates a reduced quantity of reactive species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The effective penetration distance of ultrahigh-energy electrons and photons traversing a cosmic blackbody photon gas

The effective average energy loss for an energetic (at least about 10 to the 15th power eV) particle traversing the microwave background radiation is evaluated. Electron-photon transformations by Compton scattering and pair production (in photon-photon collisions) are computed, with the energy loss considered to be carried away by the least energetic of the outgoing particles. Considering the most energetic of the outgoing particles as the high-energy particle, the relative probability and mean time for the particle to be a photon or electron (or positron) is evaluated. The effects of synchrotron losses for electrons and positrons are emphasized and compared with Compton losses to determine a critical energy (for given magnetic field) above which synchrotron losses dominate. Magnetic deflections are also treated for the case where the magnetic field is disordered, having a characteristic 'cell' size.

Gould, R. J.↗

Ring-based electron cooler for EIC

An Electron Ion Collider (EIC) at Brookhaven National Laboratory (BNL) is being proposed as a new discovery machine for the nuclear physics and quantum chromodynamics. The hadron beam cooling plays an important role in the EIC machine to achieve its physics goals. The most challenging is cooling of protons at the highest energy in the EIC. In this paper, we present a possible design of a ring-based electron cooler for the high energy hadron beam cooling. In proposed approach, the electrons will cool the hadrons while being cooled themselves by radiation damping in the storage ring. For design of the cooler using storage ring approach several aspects becomes very important, including electron ring optics design, chromaticity correction, calculate the dynamic aperture, radiation damping, quantum excitation, and intrabeam scattering (IBS). In addition, such effects as beam-beam scattering (BBS) due to interaction of electrons with hadrons become of special concern. In this paper, we discuss and take into design all the effects above, as well as introduce generalized treatment of the BBS and 3-D quantum lifetime. A special feature of our design is an effective use of dispersion in the cooling section, both for the ions and electrons, to redistribute the cooling rate between the longitudinal and horizontal planes. Finally, the cooling performance is simulated for proton beam at the top energy of the EIC. Our conclusion is that such ring-based cooler could be a feasible approach to provide required parameters of hadron beam at the top energy of 275 GeV for the EIC.

43 PARTICLE ACCELERATORS↗

Pulsed-Beam Transmission Electron Microscopy and Radiation Damage

Here, we review the use of pulsed electron-beams in transmission electron microscopes (TEMs) for the purpose of mitigating specimen damage. We begin by placing the importance of TEMs with respect to materials characterization into proper context, and we provide a brief overview of established methods for reducing or eliminating the deleterious effects of beam-induced damage. We then introduce the concept of pulsed-beam TEM, and we briefly describe the basic methods and instrument configurations used to create so-called temporally structured electron beams. Following a brief overview of the use of high-dose-rate pulsed-electron beams in cancer radiation therapy, we review historical speculations and more recent compelling but mostly anecdotal findings of a pulsed-beam TEM damage effect. This is followed by an in-depth technical review of recent works seeking to establish cause-and-effect relationships, to conclusively uncover the presence of an effect, and to explore the practicality of the approach. These studies, in particular, provide the most compelling evidence to date that using a pulsed electron beam in the TEM is indeed a viable way to mitigate damage. Throughout, we point out current gaps in understanding, and we conclude with a brief perspective of current needs and future directions.

36 MATERIALS SCIENCE↗

Electron cyclotron emission measurements and modeling in optically semi-transparent plasma on the HSX stellarator

On the Helically Symmetric Experiment (HSX), electron cyclotron emission (ECE) at the second harmonic of the electron gyrofrequency is measured with a 16-channel heterodyne receiver. An ECE radiometer diagnostic has been calibrated with a broadband frequency source, allowing independent measurements of the electron temperature. The antenna pattern has a significant impact on the measurements, and modeling its effect is necessary to produce an ECE radiation temperature spectrum. Measurements, calibration results, and modeling of the ECE data are presented in this paper. At a relatively high plasma density, HSX plasmas are thermal, and the radiation temperature measured by the radiometer is in good agreement with the electron temperature measured by a Thomson scattering diagnostic. At a relatively low plasma density, the deviation from a Maxwellian distribution is large, and asymmetry in the radiation temperature profile is measured. These measurements are supported by single-pass and multi-pass ray tracing calculations of the electron cyclotron emission using the TRAVIS ray tracing code. Thermal and nonthermal electron populations exist in HSX, and the effect of these populations on the asymmetry in the measured emission is presented.

Cyclotron radiation↗

Characterization of radiation-induced damage in high performance polymers by electron paramagnetic resonance imaging spectroscopy

The potential for long-term human activity beyond the Earth's protective magnetosphere is limited in part by the lack of detailed information on the effectiveness and performance of existing structural materials to shield the crew and spacecraft from highly penetrating space radiations. The two radiations of greatest concern are high energy protons emitted during solar flares and galactic cosmic rays which are energetic ions ranging from protons to highly oxidized iron. Although the interactions of such high-energy radiations with matter are not completely understood at this time, the effects of the incident radiation are clearly expected to include the formation of paramagnetic spin centers via ionization and bond-scission reactions in the molecular matrices of structural materials. Since this type of radiation damage is readily characterized by Electron Paramagnetic Resonance (EPR) spectroscopy, the NASA Langley Research Center EPR system was repaired and brought on-line during the 1991 ASEE term. A major goal of the 1992 ASEE term was to adapt the existing core of the LaRC EPR system to meet the requirements for EPR Imaging--a powerful new technique which provides detailed information on the internal structure of materials by mapping the spatial distribution of unpaired spin density in bulk media. Major impetus for this adaptation arises from the fact that information derived from EPRI complements other methods such as scanning electron microscopy which primarily characterize surface phenomena. The modification of the EPR system has been initiated by the construction of specially designed, counterwound Helmholtz coils which will be mounted on the main EPR electromagnet. The specifications of the coils have been set to achieve a static linear magnetic field gradient of 10 gauss/mm/amp along the principal (Z) axis of the Zeeman field. Construction is also in progress of a paramagnetic standard in which the spin distribution is known in all three dimensions. This sample will be used to assess the linearity of the magnetic field gradient and to ensure authentic image reconstruction. A second major task was to secure the computer capability to enable image reconstruction from projection data generated by the magnetic field gradients. To this end, commercially available and public domain software packages which perform inverse Fourier Transform and convoluted (filtered) back projection functions are being integrated into the existing EPR data processing system.

Suleman, Naushadalli K.↗

Improving Predictive Capability in REHEDS Simulations with Fast, Accurate, and Consistent Non-Equilibrium Material Properties

Predictive design of REHEDS experiments with radiation-hydrodynamic simulations requires knowledge of material properties (e.g. equations of state (EOS), transport coefficients, and radiation physics). Interpreting experimental results requires accurate models of diagnostic observables (e.g. detailed emission, absorption, and scattering spectra). In conditions of Local Thermodynamic Equilibrium (LTE), these material properties and observables can be pre-computed with relatively high accuracy and subsequently tabulated on simple temperature-density grids for fast look-up by simulations. When radiation and electron temperatures fall out of equilibrium, however, non-LTE effects can profoundly change material properties and diagnostic signatures. Accurately and efficiently incorporating these non-LTE effects has been a longstanding challenge for simulations. At present, most simulations include non-LTE effects by invoking highly simplified inline models. These inline non-LTE models are both much slower than table look-up and significantly less accurate than the detailed models used to populate LTE tables and diagnose experimental data through post-processing or inversion. Because inline non-LTE models are slow, designers avoid them whenever possible, which leads to known inaccuracies from using tabular LTE. Because inline models are simple, they are inconsistent with tabular data from detailed models, leading to ill-known inaccuracies, and they cannot generate detailed synthetic diagnostics suitable for direct comparisons with experimental data. This project addresses the challenge of generating and utilizing efficient, accurate, and consistent non-equilibrium material data along three complementary but relatively independent research lines. First, we have developed a relatively fast and accurate non-LTE average-atom model based on density functional theory (DFT) that provides a complete set of EOS, transport, and radiative data, and have rigorously tested it against more sophisticated first-principles multi-atom DFT models, including time-dependent DFT. Next, we have developed a tabular scheme and interpolation methods that compactly capture non-LTE effects for use in simulations and have implemented these tables in the GORGON magneto-hydrodynamic (MHD) code. Finally, we have developed post-processing tools that use detailed tabulated non-LTE data to directly predict experimental observables from simulation output.

36 MATERIALS SCIENCE↗

Effect of Oblique Electromagnetic Ion Cyclotron Waves on Relativistic Electron Scattering: CRRES Based Calculation

We consider the effect of oblique EMIC waves on relativistic electron scattering in the outer radiation belt using simultaneous observations of plasma and wave parameters from CRRES. The main findings can be s ummarized as follows: 1. In 1comparison with field-aligned waves, int ermediate and highly oblique distributions decrease the range of pitc h-angles subject to diffusion, and reduce the local scattering rate b y an order of magnitude at pitch-angles where the principle absolute value of n = 1 resonances operate. Oblique waves allow the absolute va lue of n > 1 resonances to operate, extending the range of local pitc h-angle diffusion down to the loss cone, and increasing the diffusion at lower pitch angles by orders of magnitude; 2. The local diffusion coefficients derived from CRRES data are qualitatively similar to the local results obtained for prescribed plasma/wave parameters. Conseq uently, it is likely that the bounce-averaged diffusion coefficients, if estimated from concurrent data, will exhibit the dependencies similar to those we found for model calculations; 3. In comparison with f ield-aligned waves, intermediate and highly oblique waves decrease th e bounce-averaged scattering rate near the edge of the equatorial lo ss cone by orders of magnitude if the electron energy does not excee d a threshold (approximately equal to 2 - 5 MeV) depending on specified plasma and/or wave parameters; 4. For greater electron energies_ ob lique waves operating the absolute value of n > 1 resonances are more effective and provide the same bounce_averaged diffusion rate near the loss cone as fiel_aligned waves do.

Gamayunov, K. V.↗

Mechanical Design and Configuration of Penetrations for the Europa Clipper Avionics Vault Structure

The main purpose of the Avionics Vault is to shield radiation sensitive electronics for the Europa Clipper Spacecraft. The vault is a box structure made out of aluminum panels. The panels are roughly 10 mm thick in order to shield the electronics from the orbital total ionizing radiation around Jupiter. The vault requires an electromagnetic interference (EMI) shielding effectiveness (SE) of at least 70 dB in order to mitigate EMI with the spacecraft radar receiver. Overall, the vault accommodates four main types of penetrations: receptacle connectors, pass-through cables, fluid lines, and vent holes. More than 150 cables penetrate the vault panels to connect to electronic boxes inside. Fluid pipes enter and exit the vault to transfer heat to the rest of the spacecraft. Vent holes provide a path for air to escape from the vault during launch. Several novel penetrations designs were created to meet EMI and radiation shielding requirements. Receptacle connectors interface to the vault panels using 1.3 mm thick Ta10W plates. Pass-through cables penetrate the vault using aluminum clamshells after being wrapped with Teflon cushion tape, Kapton tape, and copper tape. Vent hole penetrations consist of a copper mesh for EMI shielding and an aluminum radiation shield bracket to direct air out of the vault during launch. Fluid lines terminate at the vault wall using mechanical fittings that resemble a nut and bolt interface. In addition, most mechanical seams and penetrations utilize EMI gaskets to ensure proper EMI shielding. To reduce risk and confirm that the vault penetration designs were appropriate for EMI shielding, an EMI chamber at the Jet Propulsion Laboratory (JPL) was used to test a mock-up vault panel with multiple variations of all four main types of vault penetrations. This EMI SE test also incorporated different methods for bundling pass-through cables, and a comparison of flange mounted connectors versus jam nut connectors. A low noise preamplifier and a Rohde & Schwarz spectrum analyzer measured E-field levels transmitting through the mock-up vault panel. The results showed a shielding effectiveness of 77 dB for the mock-up vault panel, which exceeds the 70 dB target for Europa Clipper. Both the flange mounted connectors and jam nut connectors exhibited similar EMI SE results at the measured frequencies, and all variations of vault penetrations showed favorable EMI SE levels. Since the flight panels will be much larger and include many more penetrations, there will be testing of the flight vault to confirm its EMI SE is compliant with environmental requirements.

Giersch, Louis↗

Radiation-Hardened GaN-Based Wireless Communications Architectures for Terrestrial Nuclear Reactor Sensing and Instrumentation

Wireless technologies have become increasingly common in applications, ranging from close proximity inductive communication links in medical devices to short-range Bluetooth and WiFi communications and longer-range cellular communications. Nonetheless, these technologies are unsuitable for use in or around nuclear reactors due to the extreme radiation and temperatures inherent in these environments and their associated significant degradative effects on electronics hardware. However, recent work in wide bandgap– based electronics has shown promise for gallium nitride (GaN) as an emerging technology for the realization of practical wireless communications systems for use in harsh environments. This report presents initial progress on the development of wireless communications architectures designed specifically for nuclear reactor application, based on inherently radiation-hardened (rad-hard) GaN technology. Prior work on rad-hard analog communications topologies is reviewed, and several digital modulation and encoding schemes that utilize GaN-based electronics devices are newly proposed for application in reactor environments. Continuous-time and discrete-time system simulations were performed, and results are presented for the preliminary transmitter and receiver designs, respectively. In addition, an overview of a software-defined radio testbed, designed for communications protocol development, is provided. Future work will focus on implementing candidate radiation-resistant wireless architectures using a research AlGaN/GaN high electron mobility transistor (HEMT) integrated circuit process, which is available at the Ohio State University, and irradiation studies will be carried out to assess the true potential of this technology for reactor application.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NASA Engineering and Safety Center Technical Bulletin No. 19-01-1: Mitigating Risks of Single-Event Effects in Space Applications

Since most Electrical, Electronic, and Electromechanical (EEE) parts are intended for terrestrial applications, they are susceptible to a range of radiation threats in the space environment if the resulting effects are not properly characterized and mitigated. Even specially designed radiation-hardened parts may not be tolerant to all types of radiation effects. Radiation hardness is a multi-dimensional property of any part that describes intrinsic abilities to tolerate various radiation environments [1,2]. Effects to be concerned with include total ionizing dose, total non-ionizing dose, and single-event effects (SEE) – all of which depend on the mission, environment, application, and lifetime. Radiation effects concerns may be the same whether a EEE part is Commercial-Off-The-Shelf (COTS), MIL-SPEC, or some other variant, all of which are susceptible to the same radiation threats [3]. SEE consequences range from recoverable faults to catastrophic failure. Like other random faults, SEE can be mitigated with informed circuit design practices at the device, card, and/or system level.

Single-event effects↗

Collisional-Radiative Nonequilibrium and Precursor Effects in a Nitrogen Shock Wave

Improvements to a plasma code with a Collisional-Radiative (CR) non-equilibrium model are made, allowing for a more accurate description of the physical processes. The code allows for non-Boltzmann distributions of the electronic excited states by convecting separately each excited state, as a pseudo-specie. Each molecular state has also its own vibrational temperature, while a global rotational temperature is assumed. The free electron temperature is different from those of the excited states, and the electron heat conduction is also included. The CR model also uses a unique coupling between chemistry and vibrational energy (C-V coupling), which is fully coherent, and has the property of establishing thermal equilibrium as well as chemical equilibrium, on its own. We have also included a coupling between electronic excitations and vibrational energy (X-V coupling), which can have a strong influence on the vibrational temperature of some states. The recent improvements include the multi- temperature dependence of the chemical rates for associative ionization, as well as the estimation of the internal energies transferred during this process. Additionally, the distribution of energy into different translational modes (electron and heavy particles) is now correctly modeled. This provides a very rapid heating mechanism for the free electrons, since it is found that the electrons are generated with an average thermal energy of the same order as the heavy particle translational energy. This effect was observed by Gorelov et al in a recent paper, and lead to pronounced peaks in electron temperature immediately behind the shock. We will attempt ro reproduce this phenomenon. The last modification concerns the inclusion of the radiative terms into the calculations, thus enabling us to observe the effect of radiative losses and radiation transport. Preliminary tests have shown that the radiative losses are not negligible, i.e. the shock velocity drops when the radiative emission is included. In addition, we have observed some precursor excitation and ionization phenomena. These may be important at high shock velocities, and this will be investigated in detail. Precursor phenomena were also observed (in air) by Gorelov et al, and our results (for pure nitrogen) will be qualitatively compared with theirs.

Cambier, Jean-Luc↗