Radiation Response of Emerging High Gain, Low Noise Detectors

Data illustrating the radiation response of emerging high gain, low noise detectors are presented. Ionizing dose testing of silicon internal discrete avalanche photodiodes, and 51-MeV proton testing of InGaAs/InAlAs avalanche photodiodes operated in Geiger mode are discussed.

avalanche photodiodes↗

Proton-induced radiation damage in germanium detectors

High-purity germanium (HPGe) detectors will be used in future space missions for gamma-ray measurements and will be subject to interactions with energetic particles. To simulate this process, several large-volume n-type HPGe detectors were incrementally exposed to a particle fluence of up to 10 to the 8th protons/sq cm (proton energy: 1.5 GeV) at different operating temperatures (90 to 120 K) to induce radiation damage. Basic scientific and engineering data on detector performance were collected. During the incremental irradiation, the peak shape produced by the detectors showed a significant change from a Gaussian shape to a broad complex structure. After the irradiation, all detectors were thoroughly characterized by measuring many parameters. To remove the accumulated radiation damage, the detectors were stepwise-annealed at temperatures below 110 C, while kept in their specially designed cryostats. This study shows that n-type HPGe detectors can be used in charged-particle environments as high-energy resolution devices until a certain level of radiation damage is accumulated and that the damage can be removed at moderate annealing temperatures and the detector returned to operating condition.

Brueckner, J.↗

GAMMA SPECTRUM STABILIZATION FOR ENVIRONMENTAL RADIATION MONITORING STATIONS USING NAI(TL) DETECTOR

Abstract Gamma spectrum measured by an NaI(Tl) detector is known to be unstable with the in situ temperature. In the present work, an advanced method has been applied to stabilize the gamma spectrum measured by the NaI(Tl) detector at environmental radiation monitoring (ERM) stations. The method is based on experimental data obtained under controlled conditions in laboratory. In the temperature range from 4 to 45°C, the relative deviation of the peak positions within the stabilized gamma spectrum is less than 2%. To test this method in a real scenario, it has been integrated into the ERM station at the Military Institute of Chemical and Environmental Engineering in Hanoi, Vietnam. The results show that the proposed method is ready for a real application.

Hung, Dinh Tien↗

CEPS - A Compact Electron-Proton Spectrometer

Small mass/power sensors are needed for autonomous Moon surface ops that provide alerts to impending adverse space weather conditions. In order to use current operational forecasting tools, a sensor capable of measuring both high-energy electrons and protons is needed. By combining high-TRL Timepix technology with a CdTe layer, this project leverages known technology to fill a critical gap for surface operations. The proposed work will bring ability to provide warnings to crews to shelter with a device that can easily be carried on the Lunar and Martian surfaces.

Radiation↗

High-energy proton radiation damage of high-purity germanium detectors

Quantitative studies of radiation damage in high-purity germanium gamma-ray detectors due to high-energy charged particles have been carried out; two 1.0 cm thick planar detectors were irradiated by 6 GeV/c protons. Under proton bombardment, degradation in the energy resolution was found to begin below 7 x 10 to the 7th protons/sq cm and increased proportionately in both detectors until the experiment was terminated at a total flux of 5.7 x 10 to the 8th protons/sq cm, equivalent to about a six year exposure to cosmic-ray protons in space. At the end of the irradiation, the FWHM resolution measured at 1332 keV stood at 8.5 and 13.6 keV, with both detectors of only marginal utility as a spectrometer due to the severe tailing caused by charge trapping. Annealing these detectors after proton damage was found to be much easier than after neutron damage.

Pehl, R. H.↗

Extreme γ –Ray Radiation Tolerance of Spectrometer–Grade CsPbBr 3 Perovskite Detectors

The perovskite compound CsPbBr 3 has recently been discovered as a promising room-temperature semiconductor radiation detector, offering an inexpensive and easy-to-manufacture alternative to the current benchmark material Cd 1–x Zn x Te (CZT). The performance of CsPbBr 3 sensors is evaluated under harsh conditions, such as high radiation doses often found in industrial settings and extreme radiation in space. Results show minimal degradation in detector performance after exposure to 1 Mrad of Co-60 gamma radiation, with no significant change to energy resolution or hole mobility and lifetime. Additionally, many of the devices are still functional after being exposed to a 10 Mrad dose over 3 days, and those that do not survive can still be refabricated into working detectors. Notably, these results suggest that the failure mode in these devices is likely related to the interface between the electrode and material and their reaction, or the electrode itself and not the material itself. Overall, the study suggests that CsPbBr 3 has high potential as a reliable and efficient radiation detector in various applications, including those involving extreme fluxes and energies of gamma-ray radiation.

36 MATERIALS SCIENCE↗

A simulation pipeline for fast neutron imaging and spectroscopy using quantified detector attributes

Radiation imaging capabilities, essential in the nuclear nonproliferation regime, facilitate source localization and, in certain cases, spectroscopy. Scatter-based neutron cameras, which can measure the neutron signatures from special nuclear material, hold particular interest. Systems incorporating organic scintillators can extract neutron energy spectra, potentially distinguishing fission neutron sources from others, such as alpha-neutron sources. The development and testing of a scatter-based neutron imager, however, can be challenging without having an accurate simulation model or first constructing a prototype. This work describes a simulation pipeline that takes output from MCNPX-PoliMi simulations and creates the expected back-projection neutron images and neutron energy spectra. This pipeline was developed to improve the modeling of fast neutron imagers and bridge the current gap in literature, which predominantly focuses on gamma-ray Compton imager models. This work also reports on the significance of various real-world system considerations and their effects on the simulated detector responses. The pipeline was verified and validated with experimental data collected using a 252 Cf spontaneous fission source using a fast neutron scattering imager developed at the University of Michigan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SNAP-8 post shutdown gamma radiation approximations

Detector responses were calculated for normalized sources in the Perkins and King energy group structure for a SNAP 8 power system on a NASA space station. Gamma decay rates were then calculated by using an expanded, updated list of isotopic decay data, and from these, actual detector responses were found for the SNAP 8 system. The results indicate that energy-dependent calculations must be made to determine decay gamma dose rates for actual reactor configurations. A simplified method for making these calculations has been devised.

Byrn, N. R.↗

Radiation damage of the HEAO C-1 germanium detectors

The effects of radiation damage from proton bombardment of the four HEAO C-1 high purity germanium detectors have been measured and compared to predictions. Because of the presence of numerous gamma-ray lines in the detector background spectra and because of the relatively long exposure time of the HEAO 3 satellite to cosmic-ray and trapped protons, it has been possible to measure both the energy and time dependence of radiation damage. After 100 d in orbit, each of the four detectors has been exposed to approximately 3 x 10 to the 7th protons/sq cm, and the average energy resolution at 1460 keV had degraded from 3.2 keV fwhm to 8.6 keV fwhm. The lines were all broadened to the low energy side although the line profile was different for each of the four detectors. The damage-related contribution to the degradation in energy resolution was found to be linear in energy and proton influence.

Mahoney, W. A.↗

Variable-Temperature Cryostat For Radiation-Damage Testing Of Germanium Detectors

Variable-temperature cryostats developed to study radiation damage to, and annealing of, germanium gamma-ray detectors. Two styles: one accommodates large single detector and one accommodates two medium-sized detectors. New cryostats allow complete testing of large-volume germanium gamma-ray detectors without breaking cryostat vacuum and removing detectors for annealing.

Floyd, Samuel R.↗

Radiation Damage and Mitigation by Minority Carrier Injection in InAsSb/AlAsSb Heterojunction Barrier Mid-Wave Infrared Detector

Here, the effects of gamma and proton irradiation, and of forward bias minority carrier injection, on photo-response were investigated for InAsSb/AlAsSb pBn mid-wave infrared (MWIR) detectors with an engineered majority-carrier barrier. Room-temperature gamma irradiation had an insignificant effect on 77 K photo-response. Gamma irradiation at 77 K detector temperature, however, decreased in situ photo-response by 19% after a cumulative dose of ~ 500 krad(Si). Subsequent forward bias minority carrier injection had no effect on photo-response. The 77 K detectors irradiated with 30 MeV protons up to 2 Mrad(Si) had photo-response degraded by up to 70%, but here forward bias minority carrier (hole) injection caused up to 12% recovery that persisted more than 30 min. These results suggest a mitigation strategy for maintaining the photo-response of similar detectors in radiation environments that cause displacement damage defects.

36 MATERIALS SCIENCE↗

A Radiation-Hard Silicon Drift Detector Array for Extraterrestrial Element Mapping

Measurement of x-rays from the surface of objects can tell us about the chemical composition Absorption of radiation causes characteristic fluorescence from material being irradiated. By measuring the spectrum of the radiation and identifying lines in the spectrum, the emitting element (s) can be identified. This technique works for any object that has no absorbing atmosphere and significant surface irradiation : Our Moon, the icy moons of Jupiter, the moons of Mars, the planet Mercury, Asteroids and Comets

Gaskin, Jessica↗

Characterization of Low Gain Avalanche Detector Prototypes’ Response to Gamma Radiation

Motivated by the need for fast timing detectors to withstand up to 2 MGy of ionizing dose at the High Luminosity Large Hadron Collider, prototype low gain avalanche detectors (LGADs) have been fabricated in a single pad configuration, 2 × 2 arrays, and related p-i-n diodes, and exposed to Co-60 sources for study. Devices were fabricated with a range of dopant layer concentrations, and for the arrays, a variety of inter-pad distances and distances from the active area to the edge. Measurements of capacitance versus voltage and leakage current versus voltage have been made to compare pre- and post-irradiation characteristics in gain layer depletion voltage, full bulk depletion voltage, and breakdown voltage. Conclusions are drawn regarding the effects of the gammas on both surface and interface states and on their contribution to acceptor removal through non-ionizing energy loss from Compton electrons or photoelectrons. Comparison of the performances of members of the set of devices can be used to optimize gain layer parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗