Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Simulations of the implosion and stagnation of compact wire arrays

Wire array z-pinches have been used successfully for many years as a powerful x-ray source, as a dynamic hohlraum, and as an intense K-shell radiation source. Significant progress has been made in the effective modeling of these three-dimensional (3D) resistive plasmas. However, successful modeling also requires an accurate representation of the power delivered to these loads from the generator, which is an uncertainty potentially as large as the magnetohydrodynamic (MHD) implosion dynamics. We present 3D resistive MHD simulations of wire arrays that are coupled to transmission line equivalent models of the Z generator, driven by voltage sources derived directly from electrical measurements. Significant (multi-mega-ampere) current losses are shown to occur in both the convolute and the final feed. This limits the array performance and must be correctly accounted for to accurately represent the generator response to the load. Our simulations are validated against data for compact: 20 mm diameter, 10 mm long wire arrays that have produced the highest x-ray power densities on Z. This is one of the most comprehensive experimental data sets for single and nested wire arrays and includes voltage, current, x-ray power and energy, and multiple mass distribution measurements. These data tightly constrain our simulation results and allow us to describe in detail both the implosion and stagnation, and how energy is delivered to, and radiated from z-pinch loads. We show that the radiated power is consistent with the kinetic energy delivered to a distributed 3D mass profile over its implosion and stagnation. We also demonstrate how the local inductance of the transmission line connecting to the wire array is responsible for delivering more than 50% of the total radiated power. This makes the power output dependent on the design of specific elements of the generator, and their response to the imploding load, and not just on the peak current that can be delivered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Boosted High-Harmonics Pulse from a Double-Sided Relativistic Mirror

An ultrabright high-power x- and gamma-radiation source is proposed. A high-density thin plasma slab, accelerating in the radiation pressure dominant regime by an ultraintense electromagnetic wave, reflects a counterpropagating relativistically strong electromagnetic wave, producing extremely time-compressed and intensified radiation. The reflected light contains relativistic harmonics generated at the plasma slab, all upshifted with the same factor as the fundamental mode of the incident light. The theory of an arbitrarily moving thin plasma slab reflectivity is presented.

07 ISOTOPE AND RADIATION SOURCES↗

The Use Of Full-Field XRF For Simultaneous Elemental Mapping

The characteristics of a Full-Field X-ray Fluorescence (FF-XRF) set-up for element-specific imaging, installed at the HASYLAB synchrotron radiation source, were determined. A lateral resolution of 10 {mu}m and limits of detection in the percentage range were found. Further potential developments in CCDs available for FF-XRF are discussed and the use of polycapillary lenses as image transfer optics is illustrated in some explorative experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a virtual Z{sub eff} diagnostic for the W7-X stellarator

For the W7-X stellarator a diagnostic system for measurement of local Z{sub eff} values from the visible bremsstrahlung continuum is foreseen. The method is based on passive, absolute measurement of the bremsstrahlung intensity along several lines of sight. In order to eliminate the spurious impact of other radiation sources of different spectral intensity distribution than the bremsstrahlung, like the line radiation, it is intended to spectrally resolve the detected radiation, e.g., by use of microspectrometers. The visible bremsstrahlung background can be extracted by making use of the 1/{lambda}{sup 2} dependence of its intensity (expressed in unit W/m{sup 3} sr nm) in the high temperature plasmas by using Bayesian data analysis techniques. In a second step, the local values of Z{sub eff} as a function of the effective plasma radius are derived by inversion, using different regularization methods, of the line-integrated bremsstrahlung signals with the knowledge of the magnetic flux surfaces. Inversion of the full model based on statistical methods allows taking into account all conceivable uncertainties accompanying Z{sub eff} measurement and provides uncertainties of the local Z{sub eff} values and valuable information on other uncertain parameters of the model. In this paper we show the first steps in developing a virtual Z{sub eff} diagnostic for W7-X which allows the optimization of the statistical model as well as of the future diagnostic setup.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A multicenter study to quantify systematic variations and associated uncertainties in source positioning with commonly used HDR afterloaders and ring applicators for the treatment of cervical carcinomas

Purpose: The reconstruction of radiation source position in the treatment planning system is a key part of the applicator reconstruction process in high dose rate (HDR) brachytherapy treatment of cervical carcinomas. The steep dose gradients, of as much as 12%/mm, associated with typical cervix treatments emphasize the importance of accurate and precise determination of source positions. However, a variety of methodologies with a range in associated measurement uncertainties, of up to ±2.5 mm, are currently employed by various centers to do this. In addition, a recent pilot study by Awunor et al. [“Direct reconstruction and associated uncertainties of {sup 192}Ir source dwell positions in ring applicators using gafchromic film in the treatment planning of HDR brachytherapy cervix patients,” Phys. Med. Biol. 58, 3207–3225 (2013)] reported source positional differences of up to 2.6 mm between ring sets of the same type and geometry. This suggests a need for a comprehensive study to assess and quantify systematic source position variations between commonly used ring applicators and HDR afterloaders across multiple centers. Methods: Eighty-six rings from 20 European brachytherapy centers were audited in the form of a postal audit with each center collecting the data independently. The data were collected by setting up the rings using a bespoke jig and irradiating gafchromic films at predetermined dwell positions using four afterloader types, MicroSelectron, Flexitron, GammaMed, and MultiSource, from three manufacturers, Nucletron, Varian, and Eckert & Ziegler BEBIG. Five different ring types in six sizes (Ø25–Ø35 mm) and two angles (45° and 60°) were used. Coordinates of irradiated positions relative to the ring center were determined and collated, and source position differences quantified by ring type, size, and angle. Results: The mean expanded measurement uncertainty (k = 2) along the direction of source travel was ±1.4 mm. The standard deviation associated with the source position reproducibility was within ±1.0 mm for all afterloaders. Maximum source positional variations of 2.1 and 3.9, 1.8 and 5.4, and 2.3 and 3.4 mm were observed at standard treatment positions for the Ø26, Ø30, and Ø32 mm sized 45° and 60° rings, respectively. Mean positional differences between a majority of the rings were within ±1.0 mm. Mean positional differences between a majority of the intracenter ring sets were within the expanded measurement uncertainty. When comparing the 45°–60° source paths, mean differences of 1.6, 0.9, and 0.9 mm were observed across the Ø26, Ø30 (MicroSelectron), and Ø32 mm (GammaMed) rings, respectively. When comparing to manufacturer source path models, maximum offsets of 1.9 and 2.1, 2.6 and 2.3, and 0.8 and 1.6 mm were observed for the Ø26, Ø30 (MicroSelectron), and Ø30 mm (Flexitron) sized 45° and 60° rings, respectively. When comparing the audit to ring commissioning data of participating centers, mean differences of up to 2.4 mm were observed. Conclusions: A majority of the audited rings showed a good degree of manufacturer consistency; however, substantial positional variation observed between some rings emphasizes the importance of commissioning each ring before clinical use. Differences observed between audit and commissioning data also indicate some variation in source treatment positions across centers.

60 APPLIED LIFE SCIENCES↗

25+2 poles, 4.3 T wiggler at BMIT – 7 years operational experience

The research program at the Biomedical Imaging and Therapy (BMIT) Facility at the Canadian Light Source (CLS) required a unique radiation source that would provide a wide beam fan with high critical energy and high dose rates. A superconductive wiggler was the only practical solution that could be installed inside the CLS ring. Design requirements were defined in 2005 [1-2]. The wiggler, optimized for a 3 GeV ring, was to match operating parameters of an equivalent hard X-ray source on a 6 GeV ring. Manufacturing started in 2006 and the wiggler was installed in November of 2007 [3-5]. Several modifications to external hardware and to the power supplies’ controls were implemented to address the air leaks into the He space and to provide the ability to change the field of the wiggler during normal operation without affecting other research groups. The original burst disk and pressure relief valves were replaced with commercial units. Most of the buna O-rings were replaced with metal O-rings, helping to provide air-tightness of external connections. Over the years, the nominal, no-load temperatures went up by 0.3 K at the LHe space and up by 4 K at the 50 K shield space due to deterioration of thermal links and insulation, resulting from thermal cycling and vibrations generated by cryo-coolers. In October of 2014 the wiggler went through major maintenance to improve the thermal links operation, to improve the LHe transfer line connection, to install additional heaters to mitigate potential ice growth, and to provide a separate exhaust path for the rupture disk port.

43 PARTICLE ACCELERATORS↗

A watt-class 1-THz backward-wave oscillator based on sine waveguide

A novel backward wave oscillator was proposed by utilizing a concise sine waveguide slow-wave structure combined with sheet electron beam to operate at terahertz frequency band. First, the design method was described, and the dispersion curve and interaction impedance of the sine waveguide were calculated, then the device oscillation frequency and operating voltage were determined. Next, the circuit transmission losses were learned over the tunable frequency range. Finally, the particle-in-cell simulation method was applied to predict its signal generation performance. The investigation results show that, the backward wave oscillator can produce over 1.9 -W peak power output at the central operating frequency of 1-THz under 27-kV operating voltage and 5-mA beam current. And the interaction efficiency at 1-THz is more than 1.4% with a circuit length of 7.2-mm. It, therefore, will be considered as a promising watt-class terahertz radiation source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photoconductive detectors with fast temporal response for laser produced plasma experiments

Processes during laser plasma experiments typically have time scales that are less than 100 ps. The measurement of these processes requires x-ray detectors with fast temporal resolution. We have measured the temporal responses and linearity of several different x-ray sensitive photoconductive detectors (PCDs). The active elements of the detectors investigated include both diamond (natural and synthetic) and GaAs crystals. The typical time responses of the GaAs PCDs are approximately 60 ps, respectively. Some characterizations using x-ray radiation from a synchrotron radiation source are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of transit dose profile for a {sup 192}Ir HDR source

Purpose: Several studies have reported methodologies to calculate and correct the transit dose component of the moving radiation source for high dose rate (HDR) brachytherapy planning systems. However, most of these works employ the average source speed, which varies significantly with the measurement technique used, and does not represent a realistic speed profile, therefore, providing an inaccurate dose determination. In this work, the authors quantified the transit dose component of a HDR unit based on the measurement of the instantaneous source speed to produce more accurate dose values. Methods: The Nucletron microSelectron-HDR Ir-192 source was characterized considering the Task Group 43 (TG-43U1) specifications. The transit dose component was considered through the calculation of the dose distribution using a Monte Carlo particle transport code, MCNP5, for each source position and correcting it by the source speed. The instantaneous source speed measurements were performed in a previous work using two optical fibers connected to a photomultiplier and an oscilloscope. Calculated doses were validated by comparing relative dose profiles with those obtained experimentally using radiochromic films. Results: TG-43U1 source parameters were calculated to validate the Monte Carlo simulations. These agreed with the literature, with differences below 1% for the majority of the points. Calculated dose profiles without transit dose were also validated by comparison with ONCENTRA{sup Registered-Sign} Brachy v. 3.3 dose values, yielding differences within 1.5%. Dose profiles obtained with MCNP5 corrected using the instantaneous source speed profile showed differences near dwell positions of up to 800% in comparison to values corrected using the average source speed, but they are in good agreement with the experimental data, showing a maximum discrepancy of approximately 3% of the maximum dose. Near a dwell position the transit dose is about 22% of the dwell dose delivered by the source dwelling 1 s and reached 104.0 cGy per irradiation in a hypothetical clinical case studied in this work. Conclusions: The present work demonstrated that the transit dose correction based on average source speed fails to accurately correct the dose, indicating that the correct speed profile should be considered. The impact on total dose due to the transit dose correction near the dwell positions is significant and should be considered more carefully in treatments with high dose rate, several catheters, multiple dwell positions, small dwell times, and several fractions.

60 APPLIED LIFE SCIENCES↗

Radiation protection and instrumentation

Radiation was found not to be an operational problem during the Apollo program. Doses received by the crewmen of Apollo missions 7 through 17 were small because no major solar-particle events occurred during those missions. One small event was detected by a radiation sensor outside the Apollo 12 spacecraft, but no increase in radiation dose to the crewmen inside the spacecraft was detected. Radiation protection for the Apollo program was focused on both the peculiarities of the natural space radiation environment and the increased prevalence of manmade radiation sources on the ground and onboard the spacecraft. Radiation-exposure risks to crewmen were assessed and balanced against mission gain to determine mission constraints. Operational radiation evaluation required specially designed radiation detection systems onboard the spacecraft in addition to the use of satellite data, solar observatory support, and other liaison. Control and management of radioactive sources and radiation-generating equipment was important in minimizing radiation exposure of ground-support personnel, researchers, and the Apollo flight and backup crewmen.

J. Vernon Bailey↗

Performance of the AILES THz-Infrared beamline at SOLEIL for High resolution spectroscopy

The new THz beamline (AILES) located at the third generation Synchrotron Radiation source SOLEIL is now operating for applications in a wide variety of research themes. In particular, this source with its adapted optics allows high resolution spectroscopic measurements of molecules in the entire infrared and THz range. This presentation focuses on the performances concerning flux, spectral range and stability for molecular spectroscopy. Thanks to these performances, the coupling of synchrotron radiation from a highly stable third generation source with high resolution FTIR spectrometer and with a long path cell (150 m or more) can be particularly advantageous. This fact is related to the optics of the beamline permitting the entire source to be used without aperture stop (entrance iris), even for measurements at highest-resolution of approx0.1 mueV (10{sup -3} cm{sup -1}).

43 PARTICLE ACCELERATORS↗

High-intensity source of extreme ultraviolet

High intensity ultraviolet radiation source was developed which is suitable for emission below 500 A. Source, useful for 100 to 1000 A range, is simple and inexpensive to construct, easy to operate, and very stable. Because of sufficiently intense output spectrum, source can be used with monochromator at wavelengths as low as 160 A.

Paresce, E.↗

Photon counts from stellar occultation sources

The feasibility of using stars as radiation sources for Earth atmospheric occultation experiments is investigated. Exoatmospheric photon counts of the order of 10 to the 6th power photons/sq cm/sec are realized for the 15 visually brightest stars. Most photon counts appear to be marginally detectable unless photomultiplier or cascade detection devices can be used.

Buglia, James J.↗

Superconducting switch concept applied to superconducting undulator phase-error correction

Superconducting undulator (SCU) technology has the potential to significantly enhance the performance of synchrotron radiation sources for storage ring and FEL applications. Since 2002, our team at Lawrence Berkeley National Laboratory has been performing R and D on superconducting undulators, including the fabrication of three Nb{sub 3}Sn prototypes. We have demonstrated experimentally the possibility to provide the prototype with trim coils that could be used for phase error correction. The research effort that we report here demonstrates the possibility to add degrees of freedom to the field correction provided by these coils in a cryogenic environment. By means of bridge of superconducting switches, we can modify the current direction through a trim coil. Here we describe the design of the experimental bridge we fabricated, the results we obtained and finally the generalized concept one could plan to apply to correct the phase errors with trim coils connected to a network of superconducting bridges.

43 PARTICLE ACCELERATORS↗

Generating a heated fluid using an electromagnetic radiation-absorbing complex

A vessel including a concentrator configured to concentrate electromagnetic (EM) radiation received from an EM radiation source and a complex configured to absorb EM radiation to generate heat. The vessel is configured to receive a cool fluid from the cool fluid source, concentrate the EM radiation using the concentrator, apply the EM radiation to the complex, and transform, using the heat generated by the complex, the cool fluid to the heated fluid. The complex is at least one of consisting of copper nanoparticles, copper oxide nanoparticles, nanoshells, nanorods, carbon moieties, encapsulated nanoshells, encapsulated nanoparticles, and branched nanostructures. Further, the EM radiation is at least one of EM radiation in an ultraviolet region of an electromagnetic spectrum, in a visible region of the electromagnetic spectrum, and in an infrared region of the electromagnetic spectrum.

36 MATERIALS SCIENCE↗

Refraction Introscopy Imaging at Synchrotron Radiation for Medical Diagnostics

The technique of X-ray refraction introscopy imaging is reviewed. Experiments on the refraction imaging carried out at the Kurchatov Synchrotron Radiation Source with mammographic phantom, small laboratory animals, and model objects are described. Contrast enhancement compared to conventional imaging is demonstrated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

End-to-end calculation of the radiation characteristics of VVER-1000 spent fuel assemblies

The results of end-to-end calculation of the radiation characteristics of VVER-1000 spent nuclear fuel are presented. Details of formation of neutron and gamma-radiation sources are analyzed. Distributed sources of different types of radiation are considered. A comparative analysis of calculated radiation characteristics is performed with the use of nuclear data from different ENDF/B and EAF files and ANSI/ANS and ICRP standards.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗