Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RF ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Design and Preliminary Performance Testing of Electronegative Gas Plasma Thruster

In classical gridded electrostatic ion thrusters, positively charged ions are generated from a plasma discharge of noble gas propellant and accelerated to provide thrust. To maintain overall charge balance on the propulsion system, a separate electron source is required to neutralize the ion beam as it exits the thruster. However, if high-electronegativity propellant gases (e.g., sulfur hexafluoride) are instead used, a plasma discharge can result consisting of both positively and negatively charged ions. Extracting such electronegative plasma species for thrust generation (e.g., with time-varying, bipolar ion optics) would eliminate the need for a separate neutralizer cathode subsystem. In addition for thrusters utilizing a RF plasma discharge, further simplification of the ion thruster power system may be possible by also using the RF power supply to bias the ion optics. Recently, the PEGASES (Plasma propulsion with Electronegative gases) thruster prototype successfully demonstrated proof-of-concept operations in alternatively accelerating positively and negatively charged ions from a RF discharge of a mixture of argon and sulfur hexafluoride.i In collaboration with NASA Marshall Space Flight Center (MSFC), the Georgia Institute of Technology High-Power Electric Propulsion Laboratory (HPEPL) is applying the lessons learned from PEGASES design and testing to develop a new thruster prototype. This prototype will incorporate design improvements and undergo gridless operational testing and diagnostics checkout at HPEPL in April 2014. Performance mapping with ion optics will be conducted at NASA MSFC starting in May 2014. The proposed paper discusses the design and preliminary performance testing of this electronegative gas plasma thruster prototype.

Liu, Thomas M.↗

Performance Study of K2CsSb Photocathode inside a DC High Voltage Gun

In the past decade, there has been considerable interest in the generation of tens of mA average current in a photoinjector. Until recently, GaAs:Cs cathodes and K2CsSb cathodes have been tested successfully in DC and RF injectors respectively for this application. Our goal is to test the GaAs:Cs in RF injector and the K2CsSb cathode in the DC gun in order to widen our choices. Since the multialkali cathode is a compound with uniform stochiometry over its entire thickness, we anticipate that the life time issues seen in GaAs:Cs due surface damage by ion bombardment would be minimized with this material. Hence successful operation of the K2CsSb cathode in DC gun could lead to a relatively robust electron source capable of delivering ampere level currents. In order to test the performance of K2CsSb cathode in a DC gun, we have designed and built a load lock system that would allow the fabrication of the cathode at BNL and its testing at JLab. In this paper, we will present the design of the load-lock system, cathode fabrication, and the cathode performance in the preparation chamber and in the DC gun.

43 PARTICLE ACCELERATORS↗

Using a TE011 Cavity as a Magnetic Momentum Monitor

The Jefferson Lab Electron-Ion Collider (JLEIC) design relies on cooling of the ion beam with bunched electron beam constrained in a pair of long solenoids. The high current cooling electron beam needs to be generated in a magnetized electron source, and the beam's magnetization needs to be maintained during the acceleration and transport to the cooling channel. A non-invasive real time monitoring system is highly desired to quantify electron beam magnetization. The authors propose to use a passive copper RF cavity in TE011 mode as such a monitor. In this paper, we present the mechanism and scaling law of this device, as well as the design and preliminary test results of the prototype cavity.

Guo, Jiquan↗

In situ SRF cavity processing using optical ionization of gases

A system and method for the in situ processing of internal SRF cavity surfaces to reduce field emission and improve maximum gradient. An electromagnetic radiation source is introduced in the bore of a superconducting cavity to enhance ionization or dissociation of gases which then remove contaminants from the surface of the cavity, either through direct surface bombardment, chemical reaction or through the production of radiation which interacts with the contaminants. An RF or low frequency electromagnetic field may be established in the cavity which further enhances the ionization or dissociation process and may cause the ions to bombard sites with enhanced electric fields. The invention removes the requirement that the RF field be sufficient by itself to ionize gas in the cavity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of tantalum deposition and growth on TiB2 and ZrB2 from PISCES-RF deuterium and helium plasma exposures

Deuterium and helium plasma exposures on bulk TiB2 and ZrB2 samples were performed using the PISCES-RF linear plasma device. 40 and 90 eV deuterium ion plasma exposures were performed at 240 and 800 °C sample temperatures, and 80 eV helium ion plasma exposures were performed at 800 °C sample temperatures. Following plasma exposures, it was discovered that two plasma conditions (90 eV deuterium and 80 eV helium at 800 °C) resulted in thick (>200 nm) tantalum-rich (>10 at%) surface features on the targets, presumably from tantalum sourced from a tantalum adapter mask or cap used as part of the target holder. This work aims to characterize these tantalum-rich features and examine the mechanisms of impurity deposition.Plasma-induced surface morphology of the tantalum-rich surface layers depends on plasma properties and target temperature and chemistry. Greater titanium sputtering compared to zirconium resulted in more distinct surface features in the TiB2 samples compared to the ZrB2 samples via increased, prompt deposition onto tantalum surface impurities. There is still uncertainty as to why thick tantalum deposition only occurred under some plasma exposure conditions but not others; it is likely due to tantalum sputtering by a combination of boron molecules from the targets and carbon-impurities in the tantalum mask or targets. Impurity driven surface features are a well-documented phenomena in samples exposed to plasma from linear plasma device facilities—this work confirms the occurrence of this and emphasizes the need for chemistry characterization of isolated post-mortem surface features in plasma-exposed samples.

Nuckols, Lauren↗

Radio-frequency sheath voltages and slow wave electric field spatial structure

We investigate theoretically how sheath radio-frequency (RF) oscillations relate to the spatial structure of the RF parallel electric field emitted by Ion Cyclotron (IC) wave launchers, using a simple model of Slow Wave (SW) evanescence coupled with Direct Current (DC) plasma biasing via sheath boundary conditions in a plasma-filled 2-dimensional (parallel, radial) rectangle. Within a “wide sheaths” asymptotic regime, valid for large-amplitude near RF fields, our model becomes partly linear: the sheath oscillating voltage at open field line boundaries is a linear combination of elementary contributions by every source point of the radiated RF field map. These individual contributions are all the more intense as the SW emission point is toroidally nearer to the sheath walls. A limit formula is given for a source infinitely close to the sheaths. The decay of sheath RF voltages with the sheath/source parallel distance is quantified as a function of two characteristic SW evanescence lengths. Decay lengths are smaller than antenna parallel extensions. The sheath RF voltages at an IC antenna side limiter are therefore mainly sensitive to SW emission near this limiter, as recent observations suggest. Toroidal proximity effects could also explain why sheath oscillations persist with antisymmetric strap toroidal phasing, despite the parallel anti-symmetry of the radiated field map. They could also justify current attempts at reducing the RF fields induced near antenna boxes to attenuate sheath oscillations in their vicinity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Production of Cf-252 and other transplutonium isotopes at Oak Ridge National Laboratory

In 1957 Glenn T. Seaborg conceived and advocated for the construction of the High Flux Isotope Reactor (HFIR) and the Transuranium Processing Plant (since then renamed the Radiochemical Engineering Development Center, or REDC) at Oak Ridge National Laboratory. There, heavily shielded hot cells, glove boxes, and laboratories allow recovery of transuranium elements produced in substantial quantities. Seaborg’s vision of HFIR and REDC producing milligram quantities of berkelium, californium, and einsteinium has been fulfilled beginning in 1966 through May 2019 with 78 production campaigns yielding a cumulative totals of 1.2 g of 249 Bk, 10.2 g of 252 Cf, 39 mg of 253 Es, and 15 pg of 257 Fm. Notably, 252 Cf is a neutron source used in many industrial applications including oil exploration; process control systems for the cement industry, coal analysis, and power production; sources to start nuclear reactors and perform nondestructive materials analyses; homeland security and national defense detection devices; and medical research. Isotopes made available through transplutonium production at HFIR/REDC have enabled scientists to study the nuclear properties and reactions, chemical properties, optical properties, and solid-state properties of transplutonium elements. Long-lived isotopes have served as targets in heavy ion accelerators to produce heavier elements leading to the discovery of 104 Rf, 105 Db, 106 Sg, 113 Nh, 114 Fl, 115 Mc, 116 Lv, 117 Ts, and 118 Og. This paper reviews the evolution of the processing flowsheets to produce, separate, and purify transplutonium isotopes, which have evolved over 50 years of operation at HFIR and REDC, and summarizes directions of future work to improve the efficiency of the production operations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The Design of a High Charge Polarized Preinjector for the Electron-Ion Collider

The design of the electron pre-injector of the Electron-Ion Collider (EIC) project to generate 4 x 7 nC bunch has been advancing to meet the requirements for injection into the Rapid Cycling Synchrotron (RCS). The major challenges are high charge transport and achieving small energy spread from 3 GHz traveling-wave plate(TWP). The designed preinjector includes the polarized electron source, bunching section, TWP Linac, zigzag phase space manipulation and spin rotator. In this report, we will discuss the RF frequency selection and the way to reduce energy spread down to 0.2% by longitudinal phase space manipulate. We will also report the results of beamline simulation using space charge code and the conceptual design of spin rotator.

Wang, E.↗

Status of high current R&D Energy Recovery LINAC at Brookhaven National Laboratory

An ampere class 20 MeV superconducting Energy Recovery Linac (ERL) is under construction at Brookhaven National Laboratory (BNL) for testing of concepts relevant for high-energy coherent electron cooling and electron-ion colliders. One of the goals is to demonstrate an electron beam with high charge per bunch ({approx} 5 nC) and low normalized emittance ({approx} 5 mm-mrad) at an energy of 20 MeV. Flexible lattice of ERL loop provides a test-bed for investigating issues of transverse and longitudinal instabilities, and diagnostics for intense CW e-beam. The superconducting 703 MHz RF photoinjector is considered as an electron source for such a facility. We will start with a straight pass (gun - 5 cell cavity - beam stop) test for the SRF Gun performance studies. Later, we will install and test a novel injection line concept for emittance preservation in a lower energy merger. In this paper we present the status and our plans for construction and commissioning of this facility.

43 PARTICLE ACCELERATORS↗

Collaboration with NSTX in Calculations of Radiofrequency and Neutral Beam Heating and Current Drive

The overall objective of this project was to advance the understanding of heating and current drive necessary for toroidal magnetic confinement fusion energy reactors, and to provide accurate models for these sources to aid in understanding magneto-hydrodynamic, transport and boundary physics issues. Increased understanding is provided by computer simulation using the underlying physics laws, and will lead to greater reliability and increased efficiency of a power producing fusion reactor. The proposed work entailed applications of existing CompX Fokker-Planck, ray tracing, full-wave microwave, and particle diffusion calculator codes to the National Spherical Torus Experiment at Princeton Plasma Physics Laboratory. Special features of NSTX include that large ion orbits are emphasized in its geometry and thus offer a major opportunity within fusion research for focused exploration of their ubiquitous effects, including comparison with simulation codes. The CompX CQL3D Fokker-Planck code was be further adapted to the finite-orbit-width physics. Comparison with experiment ensured that the computer codes have sufficient accuracy to accurately model the experiments. Nonthermal distributions of energetic ions are produced in experiments-- and modeled with the codes-- exhibiting the signatures of auxiliary heating, transport, and radiation processes within the plasma. Using physics-based modeling, in conjunction with experimental data, nonthermal distributions can provide keys to validation and quantification of auxiliary heating physics. Nonthermal distributions also hold particular information on radial transport processes, not obscured by the smoothing Maxwellization effects of Coulomb collisions. Generally, radial transport is not well understood but is a key to efficient fusion energy production. By comparison with Fokker-Planck modeling, the velocity dependence of radial transport coefficients becomes experimentally accessible, particularly in cases of well-modeled sources such as neutral beams, fast wave power, or the toroidal electric field. It is clear from modeling of fast-wave interactions with ions that finite-orbit-width effects play a significant role. For example, a different set of ions is computed to intersect a given cyclotron resonance depending on whether or not radial orbit drifts are taken into account. Also, radial transport, associated bootstrap current, and alpha channeling depend on radial drifts. Ion cyclotron heating above the first harmonic interacts preferentially with higher velocity ions, giving large radial drifts. The CQL3D Fokker-Planck code, maintained by the proposers, is a physics based model used extensively within the US fusion community to compare with and interpret experimental observations. At the beginning of this grant, bounce-averages of the rf quasilinear and other operators have been performed neglecting the radial drifts which give finite orbit widths to the particle orbits. The proposed work included a major upgrade to CQL3D to include finite-orbit-width effects be accounted for by performing the bounce-averages of rf and neutral beam fast ions along guiding center orbits. This CQL3D enhancement provided microwave and neutral beam contributions to neoclassical radial transport coefficients for nonthermal distributions, and substantially increased the comprehensiveness of the ion model. Additional work validated Fokker-Planck and ray tracing modeling of neutral beam and high harmonic fast wave absorption and current drive against the NSTX experiment, as had been very successful for electron cyclotron current drive in the DIII-D tokamak at General Atomics and lower hybrid waves on C-Mod at MIT. The validation work was in conjunction with staff and graduate students at Princeton Plasma Physics Laboratory. This DOE grant supported fusion energy research, a potential long-term solution to the world's energy needs. The research grant under consideration, DE-SC0006614, provided research support at the 0.3 Full-Time-Equivalent level for application of computer models to aid in understanding and projecting efficacy of heating and current drive sources in the National Spherical Torus Experiment, a tokamak variant, at the Princeton Plasma Physics Laboratory. The NSTX experiment explores the physics of very tight aspect ratio, almost spherical tokamaks, aiming at producing steady-state fusion plasmas. The current drive is an integral part of the steady-state concept, maintaining the magnetic geometry in the steady-state tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The feasibility of electron beam slip stacking in EIC Rapid Cycling Synchrotron

Announced in 2020, the Electron Ion Collider will be constructed at Brookhaven National Lab (BNL) by modifying the existing Relativistic Heavy Ion Collider (RHIC) facility. Among the alterations include the installation of an electron storage ring (ESR) and a Rapid Cycling Synchrotron (RCS) in the existing RHIC tunnel. The RCS will accelerate polarized electrons from 400MeV to 5GeV,10GeV and 18 GeV and transfer it to the ESR. The LINAC source produces 7nC per shot meanwhile the RCS requires 28nC per bunch of charge. Currently, it is planned to inject 4 bunches into adjacent RF buckets and then merge them into a single RF bucket using fields from several RF cavities. However, this requires a kicker with an exceptionally fast rise and fall time to inject into adjacent RF bucket without disturbing the existing circulating bunch and this requires harmonic RF kickers. Our study focuses on determining the feasibility of an alternate particle injection method that will utilize slip stacking, a method that accommodates the circulation of multiple beams with different momentum in the same azimuthal space of the beampipe, thus permitting the accumulation of charge from several shots into a single RF bucket. We find the momentum aperture required for slip stacking using current RCS beam parameters exceeds the RCS’s momentum deviation limit,dp/p = 1.5%. We determine the appropriate dimensions the beam must have to enable slip stacking and conduct a literature review of slip stacking schemes in other facilities. The literature review tentatively indicates that slip stacking has not been attempted on electron beams at a major accelerator facility.. The slip stacking approach has the potential to save the cost of the harmonic RF kicker and bunch merging cavities.

43 PARTICLE ACCELERATORS↗

RHIC Polarized proton operation

The Relativistic Heavy Ion Collider (RHIC) operation as the polarized proton collider presents unique challenges since both luminosity(L) and spin polarization(P) are important. With longitudinally polarized beams at the experiments, the figure of merit is LP{sup 4}. A lot of upgrades and modifications have been made since last polarized proton operation. A 9 MHz rf system is installed to improve longitudinal match at injection and to increase luminosity. The beam dump was upgraded to increase bunch intensity. A vertical survey of RHIC was performed before the run to get better magnet alignment. The orbit control is also improved this year. Additional efforts are put in to improve source polarization and AGS polarization transfer efficiency. To preserve polarization on the ramp, a new working point is chosen such that the vertical tune is near a third order resonance. The overview of the changes and the operation results are presented in this paper. Siberian snakes are essential tools to preserve polarization when accelerating polarized beams to higher energy. At the same time, the higher order resonances still can cause polarization loss. As seen in RHIC, the betatron tune has to be carefully set and maintained on the ramp and during the store to avoid polarization loss. In addition, the orbit control is also critical to preserve polarization. The higher polarization during this run comes from several improvements over last run. First we have a much better orbit on the ramp. The orbit feedback brings down the vertical rms orbit error to 0.1mm, much better than the 0.5mm last run. With correct BPM offset and vertical realignment, this rms orbit error is indeed small. Second, the jump quads in the AGS improved input polarization for RHIC. Third, the vertical tune was pushed further away from 7/10 snake resonance. The tune feedback maintained the tune at the desired value through the ramp. To calibrate the analyzing power of RHIC polarimeters at any energy above injection, the polarized hydrogen jet target runs for every fill with both beams. Based on the known analyzing power, there is very little polarization loss between injection and 100 GeV. An alternative way is to measure the asymmetry at 100 GeV followed by ramping up to 250 GeV and back down to 100 GeV and then to measure the asymmetry again at 100 GeV. If the asymmetry after the down ramp is similar to the measurement before the up ramp, polarization was also preserved during the ramp to 250 GeV. The analyzing power at storage energy can then be extracted from the asymmetries measured at 100 GeV and 250 GeV. The tune and orbit feedbacks are essential for the down ramp to be possible. The polarized proton operation is still going on. We will push bunch intensity higher until reaching the beam-beam limit. The even higher intensity will have to wait for the electron lenses to compensate the beam-beam effect. To understand the details of spin dynamics in RHIC with two snakes, spin simulation with the real magnet fields have been developed recently. The study will provide guidance for possible polarization loss schemes. Further polarization gain will requires a polarized source upgrade; more careful setup jump quads in the AGS to get full benefit; and control emittance in the whole accelerator chain.

08 HYDROGEN↗

Initial experimental test of a helicon plasma based mass filter

High throughput plasma mass separation requires rotation control in a high density multi-species plasmas. A preliminary mass separation device based on a helicon plasma operating in gas mixtures and featuring concentric biasable ring electrodes is introduced. Plasma profile shows strong response to electrode biasing. In light of floating potential measurements, the density response is interpreted as the consequence of a reshaping of the radial electric field in the plasma. This field can be made confining or de-confining depending on the imposed potential at the electrodes, in a way which is consistent with single particle orbit radial stability. In conclusion, concurrent spatially resolved spectroscopic measurements suggest ion separation, with heavy to light ion emission line ratio increasing with radius when a specific potential gradient is applied to the electrodes.

42 ENGINEERING↗

Performance Study of K2CsSb Photocathode Inside a DC High Voltage Gun

In the past decade, there has been considerable interest in the generation of tens of mA average current in a photoinjector. Until recently, GaAs:Cs cathodes and K{sub 2}CsSb cathodes have been tested successfully in DC and RF injectors respectively for this application. Our goal is to test the K{sub 2}CsSb photocathode inside a DC gun. Since the multialkali cathode is a compound with constant characteristics over its entire thickness, we anticipate that the lifetime issues seen in GaAs:Cs due to surface damage by ion bombardment would be minimized. Hence successful operation of the K{sub 2}CsSb cathode in a DC gun could lead to a relatively robust electron source capable of delivering ampere level currents. In order to test the performance of a K{sub 2}CsSb cathode in a DC gun, we have designed and built a load lock system that allows the fabrication of the cathode at Brookhaven National Lab (BNL) and its testing at Jefferson Lab (JLab). In this paper, we will present the performance of the K{sub 2}CsSb photocathode in the preparation chamber and in the DC gun.

43 PARTICLE ACCELERATORS↗

The local structure, magnetic, and transport properties of Cr-doped In{sub 2}O{sub 3} films

Cr-doped In{sub 2}O{sub 3} films were deposited on Si (100) substrates by RF-magnetron sputtering technique. The local structure, magnetic, and transport properties of films are investigated by X-ray diffraction, X-ray photoelectron spectroscopy, X-ray absorption fine structure, Hall effect, R-T, and magnetic measurements. Structural analysis clearly indicates that Cr ions substitute for In{sup 3+} sites of the In{sub 2}O{sub 3} lattice in the valence of +2 states and Cr-related secondary phases or clusters as the source of ferromagnetism is safely ruled out. The films with low Cr concentration show a crossover from semiconducting to metallic transport behavior, whereas only semiconducting behavior is observed in high Cr concentration films. The transport property of all films is governed by Mott variable range hopping behavior, suggesting that the carriers are strongly localized. Magnetic characterizations show that the saturated magnetization of films increases first, and then decreases with Cr doping, while carrier concentration n{sub c} decreases monotonically, implying that the ferromagnetism is not directly induced by the mediated carriers. It can be concluded the ferromagnetism of films is intrinsic and originates from electrons bound in defect states associated with oxygen vacancies.

36 MATERIALS SCIENCE↗

A Dual Source Ion Trap Mass Spectrometer for the Mars Organic Molecule Analyzer of ExoMars 2018

We present details on the objectives, requirements, design and operational approach of the core mass spectrometer of the Mars Organic Molecule Analyzer (MOMA) investigation on the 2018 ExoMars mission. The MOMA mass spectrometer enables the investigation to fulfill its objective of analyzing the chemical composition of organic compounds in solid samples obtained from the near surface of Mars. Two methods of ionization are realized, associated with different modes of MOMA operation, in a single compact ion trap mass spectrometer. The stringent mass and power constraints of the mission have led to features such as low voltage and low frequency RF operation [1] and pulse counting detection.

Brickerhoff, William B.↗

Deployment of Cesium Recovered from High Level Liquid Waste for Irradiation - Indian Scenario - 13128

Recovery of Cs-137 from HLW and its utilisation as source pencil in place of Co-60 is vital for medical and sewage treatment applications in India. For separation of Cs, specific ion exchange resins as well as 'Calyx crown' solvent have been developed and synthesized indigenously. A flow sheet involving separation of Cs from acidic HLW using Ammonium Molybdo Phosphate (AMP) resins, recovery of Cs from the loaded AMP column by dissolving it in alkali, ion exchange purification of Cs rich alkaline solution using Resorcinol-Formaldehyde Poly condensate (RF) resins and its elution in cesium nitrate form was developed and demonstrated. Solvent extraction route employing 0.03 Molar, 1-3-octyl oxy Calyx (4) arene crown-6 in 30% isodecyl alcohol and dodecane was also established using mixer settlers. Cesium lithium borosilicate glass based formulations have been considered as a glass matrix for Cs irradiation pencils. While choosing this vitreous matrix, attributes addressing maximum possible Cs-137 loading, low glass pouring temperature to minimise Cs volatility, reasonably good mechanical strength and good chemical durability have been considered. Recovered cesium nitrate solution was vitrified along with glass additives in an induction heated metallic melter and subsequently poured into 12 numbers of Cs irradiation pencils positioned on turn-table equipped with the load cell. The complete cycle involving recovery of Cs from HLW followed by its conversion into Cs pencil was demonstrated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion heating and short wavelength fluctuations in a helicon plasma source

For typical helicon source parameters, the driving antenna can couple to two plasma modes; the weakly damped 'helicon' wave, and the strongly damped, short wavelength, slow wave. Here, we present direct measurements, obtained with two different techniques, of few hundred kHz, short wavelength fluctuations that are parametrically driven by the primary antenna and localized to the edge of the plasma. The short wavelength fluctuations appear for plasma source parameters such that the driving frequency is approximately equal to the lower hybrid frequency. Measurements of the steady-state ion temperature and fluctuation amplitude radial profiles suggest that the anomalously high ion temperatures observed at the edge of helicon sources result from damping of the short wavelength fluctuations. Additional measurements of the time evolution of the ion temperature and fluctuation profiles in pulsed helicon source plasmas support the same conclusion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗