Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFRACTIVE INDEX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Analysis of microwave leaky modes propagating through laser plasma filaments column waveguide

A plasma column waveguide formed by a bundle of closely spaced plasma filaments induced by the propagation of ultrafast laser pulses in air and revived by a longer infrared laser pulse is shown to support microwave radiation. We consider values of both the plasma electron density and microwave frequency for which the refractive index of plasma is lower than the refractive index of air; therefore, a leaky plasma waveguide can be realized in extremely high frequency band. The guiding mechanism does not require high conductance of the plasma and can be easily excited by using commercial femtosecond laser sources. A theoretical study of leaky mode characteristics of isotropic and homogeneous plasma column waveguides is investigated with several values of plasma and waveguide structure parameters. The microwave transmission loss was found to be mainly caused by the microwave leakage through the air-plasma interface and is weakly dependent on the plasma absorption. In spite of losses of microwaves caused by leakage and plasma absorption, it is shown to be much lower than both that accompanying to surface waves attaching to single conducting plasma wire and the free space propagation over distances in the order of the filament length, which opens exciting perspectives for short distance point to point wireless transmission of pulsed-modulated microwaves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Glancing angle deposition of SiO{sub 2} thin film microstructures: Investigations of optical and morphological properties

In present work, the optical and the morphological properties of micro-structured SiO{sub 2} thin films fabricated by using glancing angle deposition (GLAD) technique has been carried out. The results are compared with the normally deposited SiO{sub 2} films for the gained advantages. The influence of the glancing angle on the refractive index of porous SiO{sub 2} film was investigated by the spectral transmission measurement in 400–950 nm wavelength regimes. The refractive index has been found to be 1.14@532 nm for the porous SiO{sub 2} film deposited at a glancing angle of 85°. The density and surface qualities of these samples were primarily investigated by using grazing angle X-ray reflectivity (GIXR) and atomic force microscope (AFM) measurements. Results indicate a substantial decrease in film density and refractive index and increase in surface roughness and grain size for GLAD SiO{sub 2} compared to normally deposited SiO{sub 2} films.

36 MATERIALS SCIENCE↗

Dynamic refractometer

A refractometer computer controls the rotation of a rotary plate upon which are mounted a prism optically coupled via an optical window to a spectroscopic cell holding a resin exhibiting a dynamic refractive index during photocuring. The computer system positions the prism and spectroscopic cell relative to a visible light laser which illuminates the prism-resin interface at selected incidence angles. A photodetector mounted on the plate generates a signal to the computer proportional to intensity of an internally reflected light beam. A curing light is selectively transmitted through the prism and into the photocurable resin. The refractometer determines the intensity of the internally reflected beam a selected incidence angles and determines the effective refractive index curve of the resin at an uncured state and, optionally, at a completely cured state. Next, an amount of uncured resin and selected optical components to be joined by the resin is placed in the spectroscopic cell and irradiated with the UV light. The refractometer is fixed at a selected incidence angle and measures the intensity of an internally reflected light beam of light throughout the cure cycle. The refractometer determines the resin's refractive index of the polymeric mixture by means of extrapolation of a horizontal shift in the effective refractive index curve of the resin from an uncured state to a selected point in the cure cycle.

Curley, Michael J.↗

New versions of old flow visualization systems

A small, modified Mach-Zehnder interferometer placed in series with a much larger schlieren optical system spanning the test section is examined. In one arm of the interferometer, light from the schlieren is focused through a pinhole and recollimating lens to produce a reference beam which interferes with the remaining object beam from the other arm. The object and reference beams are separated only over a small interval following the test section, and differential vibrations are greatly reduced. Color schlieren has technical, as well as aesthetic, advantages over black-and-white schlieren. Since each color is associated with a specific amount of refraction, quantitative evaluation of certain refractive-index fields becomes possible using very simple equations derived from ray trace theory. Rainbow schlieren of an acetylene flame, and the evaluated refractive index distribution are shown. Root-mean-square refractive index fluctuations in homogeneous, isotropic turbulence were determined using the rainbow schlieren, since these fluctuations determine the root-mean-square refraction, which is indicated by the overall color of the image.

Howes, W. L.↗

Two-Flux Method for Transient Radiative Transfer in a Semitransparent Layer

The two-flux method was used to obtain transient solutions for a plane layer including internal reflections and scattering. The layer was initially at uniform temperature, and was heated or cooled by external radiation and convection. The two-flux equations were examined as a means for evaluating the radiative flux gradient in the transient energy equation. Comparisons of transient temperature distributions using the two-flux method were made with results where the radiative flux gradient was evaluated from the exact radiative transfer equations. Good agreement was obtained for optical thicknesses from 0.5 to 5 and for refractive indices of 1 and 2. Illustrative results obtained with the two-flux method demonstrate the effect of isotropic scattering coupled with changing the refractive index. For small absorption with large scattering the maximum layer temperature is increased when the refractive index is increased. For larger absorption the effect is opposite, and the maximum temperature decreases with increased refractive index .

Siegel, Robert↗

Rational Design of Nanoplasmonic Array Geometries for Biosensing

Background: Molecular diagnostics provide early and accurate diagnosis, which is essential for the prevention and treatment of infectious as well as chronic diseases. These tests are designed to detect disease-specific bioanalytes such as nucleic acid (DNA or RNA) or protein (antigens, antibodies) biomarkers. In the context of infectious disease diagnosis, nucleic acid-based detection methods are known to provide more specific and sensitive results. Here, the presence of a unique sequence belonging to the pathogenic genomic material is targeted to identify species, organism, genera and/or antimicrobial resistant gene markers. The majority of the common nucleic acid based diagnostic techniques require amplification (polymerase chain reaction, isothermal amplification etc.) of the pathogenic genetic material prior to detection impacting diagnostic speed, complexity, and cost thereby limiting ease of use. Thus, the development of simplified nucleic acid-based diagnostics that can be even used in resource-poor settings may hugely benefit patients across the globe. Nanopath is a molecular diagnostics company utilizing a solid-state nanosensor to enable sequence-specific detection of target nucleic acids without the need of amplification. These nanostructures enable ultra-sensitive biomarker detection using geometric, feature-dependent properties highly dependent on the local dielectric environment, allowing them to be sensitive to low concentration binding events. This paper describes an application of this approach to provide highly relevant clinical information within a single doctor’s office visit. Intro: The Nanopath team is in collaboration with NASA (National Aeronautics and Space Administration) and NIST (National Institute of Standards and Technology) to push the bounds of the fundamental physics associated with their biosensing platform. The ability of metals to support electromagnetic surface waves gives rise to surface plasmons when optically illuminated. This property, and its strong sensitivity to changes in the local refractive index, allows for the use of metal nanoparticles as ultra-sensitive transducers. In prior work by members of this team, ensembles of randomly oriented nanoparticles (i.e., colloidal nanorods dispersed on chip) were employed for sequence-specific nucleic acid sensing (1-3). While these particle sensors have the advantage of rapid fabrication, they suffer from low sensitivity and quality factor due to the random particle dispersity. In contrast, in this study we employ ordered array nanoparticle ensembles which can be used to improve sensor sensitivity and figure-of-merit. Study Methods Overview: In this talk, we detail the results of sensing experiments and computational simulations to outline a rational design of the structure of these plasmonic nanoparticle arrays for biomolecular sensing. Through simulation and experiment, we iteratively tailor nanostructure dimension to provide high quality signal and large resonance shifts upon modeled nucleic acid binding. In particular, full-wave electromagnetic simulations were conducted using Lumerical photonic simulation software in which periodic boundary conditions were applied in the x- and y- dimensions for each of the nanoplasmonic sensor geometries. To simulate the resonance response to changes in the bulk solution in contact with the sensor surface, the refractive index of the surrounding media was changed appropriately. Nucleic acid hybridization events were modeled using either using spherical structures approximating the relevant radius of genomic material as estimated by polymer models, or as conformal layers with the known refractive indices for nucleic acids. On the basis of initial simulations, nanosensors were fabricated using traditional electron-beam lithography protocols at NIST. To evaluate consensus between simulations and experiments, bulk sensing experiments were carried out in which the resonance peaks were obtained by submerging the sensors in refractive index standards. Key nanosensor characteristics including resonance peak locations, resonance peak shifts as a function of refractive index, and figure of merit (FOM) of extinction curves were examined between the experimental and simulation results prior to proceeding with simulations on additional geometries and more complex solution conditions, and further device fabrication. This iterative process is repeated toward a rational design of nanoplasmonic array geometries for biosensing optimizing response for targeted disease detection. In summary, this study puts forth a methodology for rational design and characterization of regularly spaced nanoparticle arrays for optics-based biosensing. The results of this study will allow for more informed design of nanostructure geometries towards sequence-specific nucleic acid detection. These improved designs have the potential to improve clinical sensitivity and limit-of-detection across disease indication.

sensor↗

Optical characterization of the oceanic unicellular cyanobacterium Synechococcus grown under a day-night cycle in natural irradiance

The optical properties of the ocenanic cyanobacterium Synechococcus (clone WH8103) were examined in a nutrient-replete laboratory culture grown under a day-night cycle in natural irradiance. Measurements of the spectral absorption and beam attenuation coefficients, the size distribution of cells in suspension, and microscopic analysis of samples were made at intervals of 2-4 hours for 2 days. These measurements were used to calculate the optical properties at the level of a single 'mean' cell representative of the acutal population, specifically, the optical cross sections for spectral absorption bar-(sigma(sub a)), scattering bar-sigma(sub b))(lambda), and attentuation bar-(sigma(sub c))(lambda). In addition, concurrent determinations of chlorophyll a and particulate organic carbon allowed calculation of the Chl a- and C-specific optical coefficients. The refractive index of cells was derived from the observed data using a theory of light absorption and scattering by homogeneous spheres. Low irradiance because of cloudy skies resulted in slow division rates of cells in the culture. The percentage of dividing cells was unusually high (greater than 30%) throughout the experiment. The optical cross sections varied greatly over a day-night cycle, with a minimum near dawn or midmorning and maximum near dusk. During daylight hours, bar-(sigma(sub b)) and bar-(sigma(sub c)) can increase more than twofold and bar-(sigma(sub a) by as much as 45%. The real part of the refractive index n increaed during the day; changes in n had equal or greater effect than the varying size distribution on changes in bar-(sigma(sub c)) and bar-(sigma(sub b)). The contribution of changes in n to the increase of bar-(sigma(sub c))(660) during daylight hours was 65.7% and 45.1% on day 1 and 2, respectively. During the dark period, when bar-(sigma(sub c))(660) decreased by a factor of 2.9, the effect of decreasing n was dominant (86.3%). With the exception of a few hours during the second light period, the imaginary part of the refractive index n' showed little variation over a day-night cycle, and bar-(sigma(sub a)) was largely controlled by variations in cell size. The real part of the refractive index at lambda = 660 nm was correlated with the intracellular C concentration and the imaginary part at lambda = 678 nm with the intracellular Chl a concentration. The C-specfic attenuation coefficient showed significant diel variability, which has implications for the estimation of oceanic primary production from measurements of diel variability in beam attenuation. This study provides strong evidence that diel variability is an important component of the optical characterization of marine phytoplankton.

Stramski, Dariusz↗

Absorption and related optical dispersion effects on the spectral response of a surface plasmon resonance sensor

Surface plasmon resonance (SPR) sensing is an optical technique that allows real time detection of small changes in the physical properties, in particular in the refractive index, of a dielectric medium near a metal film surface. One way to increase the SPR signal shift is then to incorporate a substance possessing a strong dispersive refractive index in the range of the plasmon resonance band. In this paper, we investigate the impact of materials possessing a strong dispersive index integrated to the dielectric medium on the SPR reflectivity profile. We present theoretical results based on chromophore absorption spectra and on their associated refractive index obtained from the Lorentz approach and Kramers-Kroenig equations. As predicted by the theory, the experimental results show an enhancement of the SPR response, maximized when the chromophore absorption band coincides with the plasmon resonant wavelength. This shows that chromophores labeling can provide a potential way for SPR response enhancement.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Special pure germanium-rich Ga-Ge-As-Se glasses for active mid-IR fiber optics

Highlights: • Special pure Ga{sub x}Ge{sub 25}As{sub 15}Se{sub 60-x} (x = 0; 1; 2; 3; 4; 5) glasses were prepared and investigated. • The glasses have high glass transition temperature (>320 °C) and low tendency to crystallization. • The microstructure, the transmission region and the linear refractive index of glasses were studied. • Dispersion optical parameters of glasses were calculated using the Wemple-DiDomenico model. • For the first time, a single-index Ga{sub 3}Ge{sub 25}As{sub 15}Se{sub 57} glass fiber was fabricated and investigated. - Abstract: Special pure Ga{sub x}Ge{sub 25}As{sub 15}Se{sub 60-x} (x = 0; 1; 2; 3; 4; 5) glasses were prepared using various methods for purification of the glass-forming melt. The glasses are characterized by high transparency in the spectral range 0.8–15 μm, low impurity content, high glass transition temperature (>320 °C), and low tendency to crystallization. The microstructure, the transmission range edges, the optical band-gap energy, and the linear refractive index of the glasses are studied. The refractive index of Ga{sub x}Ge{sub 25}As{sub 15}Se{sub 60-x} (x = 0÷5) glasses measured by ellipsometry increases with the substitution of selenium by gallium. It is for the first time that a single-index Ga{sub 3}Ge{sub 25}As{sub 15}Se{sub 57} glass fiber was fabricated, its minimum optical loss was about 0.6 dB/m at a wavelength of 6.7 μm. High-purity germanium-rich Ga-Ge-As-Se glasses were shown to be a promising material for active mid-IR fiber optics.

36 MATERIALS SCIENCE↗

Spin Hall effect of a light beam in left-handed materials

We establish a general propagation model to describe the spin Hall effect of light beam in left-handed materials (LHMs). A spin-dependent shift of the beam centroid perpendicular to the refractive index gradient for the light beam through an air-LHM interface is demonstrated. For a certain circularly polarized component, whether the transverse shift is positive or negative depends on the magnitude of the refractive index gradient. Very surprisingly, the spin Hall effect in the LHM is unreversed, although the sign of refractive index gradient is reversed. The physics underlying this counterintuitive effect is that the spin angular momentum of photons is unreversed. Further, we reveal that the angular shift in the LHM is reversed due to the negative diffraction. These findings provide alternative evidence for that the linear momentum of photons is reversed, while the spin angular momentum is unreversed in the LHM.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser schlieren deflectometry for temperature analysis of filamentary non-thermal atmospheric pressure plasma

The heat convection generated by micro filaments of a self-organized non-thermal atmospheric pressure plasma jet in Ar is characterized by employing laser schlieren deflectometry (LSD). It is demonstrated as a proof of principle, that the spatial and temporal changes of the refractive index n in the optical beam path related to the neutral gas temperature of the plasma jet can be monitored and evaluated simultaneously. The refraction of a laser beam in a high gradient field of n(r) with cylindrical symmetry is given for a general real refraction index profile. However, the usually applied Abel approach represents an ill-posed problem and in particular for this plasma configuration. A simple analytical model is proposed in order to minimize the statistical error. Based on that, the temperature profile, specifically the absolute temperature in the filament core, the FWHM, and the frequencies of the collective filament dynamics are obtained for non-stationary conditions. For a gas temperature of 700 K inside the filament, the presented model predicts maximum deflection angles of the laser beam of 0.3 mrad which is in accordance to the experimental results obtained with LSD. Furthermore, the experimentally obtained FWHM of the temperature profile produced by the filament at the end of capillary is (1.5 {+-} 0.2) mm, which is about 10 times wider than the visual radius of the filament. The obtained maximum temperature in the effluent is (450 {+-} 30) K and is in consistence with results of other techniques. The study demonstrates that LSD represents a useful low-cost method for monitoring the spatiotemporal behaviour of microdischarges and allows to uncover their dynamic characteristics, e.g., the temperature profile even for challenging diagnostic conditions such as moving thin discharge filaments. The method is not restricted to the miniaturized and self-organized plasma studied here. Instead, it can be readily applied to other configurations that produce measurable gradients of refractive index by local gas heating and opens new diagnostics prospects particularly for microplasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Melt front propagation in dielectrics upon femtosecond laser irradiation: Formation dynamics of a heat-affected layer

Several studies in dielectrics have reported the presence of a thin heat-affected layer underneath the ablation crater produced by femtosecond laser irradiation. In this work, we present a time-resolved microscopy technique that is capable of monitoring the formation dynamics of this layer and apply it to the study of a phosphate glass exposed to single pulses below the ablation threshold. A few nanoseconds after laser excitation, a melt front interface can be detected, which propagates into the bulk, gradually slowing down its speed. By means of image analysis combined with optical modeling, we are able to determine the temporal evolution of the layer thickness and its refractive index. Initially, a strong transient decrease in the refractive index is observed, which partially recovers afterwards. The layer resolidifies after approximately 1 μs after excitation, featuring a maximum thickness of several hundreds of nanometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Acoustic methods of remote probing of the lower atmosphere

The potential usefulness of acoustic methods for the remote probing of the lower atmosphere is reviewed. Starting with a comparison of the effects of temperature, wind, and humidity fluctuations upon the refractive index of air to electromagnetic and acoustic waves, it is shown that the fluctuations in acoustic refractive index may be expected to be about one thousand times stronger than in the radio case. Since the scattered power is proportional to the square of the refractive index fluctuations, the scatter of acoustic waves may be expected to be roughly one million times stronger than for radio waves. In addition, the million-fold ratio between the velocities of electromagnetic and acoustic waves results in an acoustic system requiring one million times less bandwidth to interrogate a given atmospheric volume.

Little, C. G.↗

Third-order nonlinearity of Er3+-doped lead phosphate glass

The third-order optical susceptibility and dispersion of the linear refractive index of Er3+-doped lead phosphate glass were measured in the wavelength range between 400 and 1940 nm by using the spectrally resolved femtosecond Maker fringes technique. The nonlinear refractive index obtained from the third-order susceptibility was found to be five times higher than that of silica, indicating that Er3+-doped lead phosphate glass is a potential candidate to be used as the base component for the fabrication of photonic devices. For comparison purposes, the Z-scan technique was also employed to obtain the values of the nonlinear refractive index of E-doped lead phosphate glass at several wavelengths, and the values obtained using the two techniques agree to within 15%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the third harmonic generation in a medium with negative pump wave refraction

The propagation of the pump and its third harmonic pulses in a cubically nonlinear medium is considered theoretically, provided that the linear properties of the medium are characterized by a negative refractive index at the pump frequency and a positive refractive index at the harmonic frequency. For low-intensity interacting waves, the pump and third harmonic pulses propagate in opposite directions, but sufficiently intense pulses can produce a simulton-a solitary two-frequency wave that propagates in a certain direction as a single whole. The system of equations is investigated numerically for a model that, apart from the harmonic generation, includes the second-order group velocity dispersion and the nonlinear self- and cross-phase modulations of the interacting waves. The separation of the pump and harmonic pulses due to the difference in the directions of their group velocities and peculiarities of the Manley-Rowe relation for parametric processes in metamedia are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance analysis of higher mode spoof surface plasmon polariton for terahertz sensing

We investigated the spoof surface plasmon polaritons (SSPPs) on 1D grooved metal surface for terahertz sensing of refractive index of the filling analyte through a prism-coupling attenuated total reflection setup. From the dispersion relation analysis and the finite element method-based simulation, we revealed that the dispersion curve of SSPP got suppressed as the filling refractive index increased, which cause the coupling resonance frequency redshifting in the reflection spectrum. The simulated results for testing various refractive indexes demonstrated that the incident angle of terahertz radiation has a great effect on the performance of sensing. Smaller incident angle will result in a higher sensitive sensing with a narrower detection range. In the meanwhile, the higher order mode SSPP-based sensing has a higher sensitivity with a narrower detection range. The maximum sensitivity is 2.57 THz/RIU for the second-order mode sensing at 45° internal incident angle. The proposed SSPP-based method has great potential for high sensitive terahertz sensing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cryogenic High Accuracy Refraction Measurements Capabilities and New FUV Coating Mirror Technology Developments

This talk will emphasize the basic principles of refractive materials used in an optical telescope. In particular, the presentation will describe refractive index measurements that were performed for one of the instruments on the James Webb Space Telescope (JWST). A refractive system design was implemented in the Near-Infrared Camera (NIRCam) which is one of the main instruments on the JWST observatory. This camera was designed to make observations in the infrared part of the optical spectrum, and it is required to operate in a space environment at temperatures as low as 25K. Therefore, it was imperative to know the refractive index at those low cryogenic temperatures for the various glass substrates (ZnSe, LiF and BaF2) used in the system design of NIRCam. These cryogenic index of refraction measurements were carried out by using the world-class refractometer called the Cryogenic High Accuracy Refraction Measuring System (CHARMS) facility that was designed and built at the Goddard Space Flight Center (GSFC) in Greenbelt, MD. In the second part, there will be a discussion of the recent advances on the research and development activities of advanced and new mirror coating technologies that provide high reflectance performance in the far-ultraviolet (FUV) part of the optical spectrum. These new mirror coatings are envisioned for use on the reflecting mirrors of the next mission (beyond JWST) that will focus on astronomical observations in the FUV spectral range to deliver new and exciting discoveries about the origin of the cosmos.

Astronomy↗