Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIOTHERAPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

520 records · Page 29

Proton Therapy in Supradiaphragmatic Lymphoma: Predicting Treatment-Related Mortality to Help Optimize Patient Selection

In some patients with Hodgkin lymphoma (HL), proton beam therapy (PBT) may reduce the risk of radiation-related cardiovascular disease (CVD) and second cancers (SC) compared with photon radiation therapy (RT). Our aim was to identify patients who benefit the most from PBT in terms of predicted 30-year absolute mortality risks (AMR{sub 30}) from CVD and SC, taking into account individual background, chemotherapy, radiation, and smoking-related risks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patterns of Initial Relapse from a Phase 3 Study of Response-Based Therapy for High-Risk Hodgkin Lymphoma (AHOD0831): A Report from the Children's Oncology Group

The Children's Oncology Group protocol AHOD0831, for pediatric patients with high-risk classical Hodgkin lymphoma (cHL), used response-adapted radiation fields, rather than larger involved-field radiation therapy (IFRT) that were historically used. This retrospective analysis of patterns of relapse among patients enrolled in the study was conducted to study the potential effect of a reduction in RT exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Association of Short-term Patient-reported Outcomes With Long-term Oncologic Outcomes in Localized Prostate Cancer Patients Treated With Radiation Therapy and Androgen Deprivation Therapy in a Randomized Controlled Trial

Both oncologic outcomes and patient-reported outcomes are pivotal in prostate cancer (PCa). However, it remains unknown if there is any association between these 2 outcomes. In this secondary analysis of a randomized controlled trial, we investigated the association of short-term changes in patient-reported outcome with long-term event-free survival (EFS) and metastasis-free survival (MFS) in localized PCa.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Randomized Phase 3, Double-blind, Placebo-controlled Study of Prophylactic Gabapentin for the Reduction of Oral Mucositis Pain During the Treatment of Oropharyngeal Squamous Cell Carcinoma

The purpose of this paper is to determine whether prophylactic gabapentin usage in patients undergoing definitive concurrent chemotherapy and radiation therapy (chemoRT) for oropharyngeal cancer (OPC) improves treatment-related oral mucositis pain, opioid use, and feeding tube (FT) placement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Variation in Proton Craniospinal Irradiation Practice Patterns in the United States: A Pediatric Proton Consortium Registry (PPCR) Study

Craniospinal irradiation (CSI) is commonly used for pediatric brain tumors with a propensity for spread in craniospinal fluid, principally medulloblastoma. Evolving technology has led to the use of highly conformal radiation therapy (RT) techniques for CSI, including proton therapy. Target delineation and plan coverage are critical for CSI, but there is ongoing controversy and variability in these realms, with little available data on practice patterns. We sought to characterize proton CSI practice patterns in the United States by examining CSI plans in the Pediatric Proton/Photon Consortium Registry (PPCR).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deciphering the Dynamic Molecular Program of Radiation-Induced Endothelial Senescence

Radiation-induced cellular senescence is a double-edged sword, acting as both a tumor suppression process limiting tumor proliferation, and a crucial process contributing to normal tissue injury. Endothelial cells play a role in normal tissue injury after radiation therapy. Recently, a study observed an accumulation of senescent endothelial cells (ECs) around radiation-induced lung focal lesions following stereotactic radiation injury in mice. However, the effect of radiation on EC senescence remains unclear because it depends on dose and fractionation, and because the senescent phenotype is heterogeneous and dynamic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The NRG3/ERBB4 signaling cascade as a novel therapeutic target for canine glioma

Highlights: • miR-190a was downregulated in canine brain tumors. • miR-190a functioned as a tumor-suppressor through targeting NRG3. • A pan-ERBB inhibitor exhibited a tumor suppressive effect in canine glioma cells. Canine glioma is a common brain tumor with poor prognosis despite surgery and/or radiation therapy. Therefore, newer and more effective treatment modalities are needed. Neuregulin 3 (NRG3) has known to be a ligand of ERBB4. This study aimed to investigate the usefulness of the NRG3/ERBB4 signaling cascade as a novel therapeutic target in canine glioma. We found out that microRNA (miR)-190a was downregulated in canine brain tumor tissues, including glioma and meningioma. miR-190a directly targeted NRG3 and inhibited the growth of canine glioma cells. The level of p-Akt, which is a downstream target of ERBB4 signaling, was decreased by transfection with miR-190a. NRG3 silencing also suppressed cell growth and decreased the levels of p-Akt and p-ERK1/2, and NRG3 overexpression exhibited opposed effects in canine glioma J3T-1 cells. The mRNA level of erbb4 was significantly upregulated in glioma tissues compared with that in normal brain tissues and meningioma tissues. Furthermore, compared with gefitinib and lapatinib, afatinib exerted a greater inhibitory effect on the growth of canine glioma cells. In conclusion, NRG3/ERBB4 signaling is negatively regulated by miR-190a and contributes to the growth of canine glioma cells, indicating that it may be a promising therapeutic target in canine glioma.

60 APPLIED LIFE SCIENCES↗

Demonstration of an intense lithium beam for forward-directed pulsed neutron generation

Abstract As an alternative to research nuclear reactors, a compact accelerator-driven neutron generator that uses a lithium beam driver could be a promising candidate since it produces almost no undesired radiation. However, providing an intense lithium-ion beam has been difficult, and it has been thought that the practical application of such a device would be impossible. The most critical problem of insufficient ion fluxes has been solved by applying a direct plasma injection scheme. In this scheme, a pulsed high-density plasma from a metallic lithium foil generated by laser ablation is efficiently injected and accelerated by a radio-frequency quadrupole linear accelerator (RFQ linac). We have obtained a peak beam current of 35 mA accelerated to 1.43 MeV, which is two orders of magnitude higher than a conventional injector and accelerator system can deliver.

43 PARTICLE ACCELERATORS↗

Ultra-high dose rate FLASH irradiator at the radiological research accelerator facility

The Radiological Research Accelerator Facility has modified a decommissioned Varian Clinac to deliver ultra-high dose rates: operating in 9 MeV electron mode ( FLASH mode), samples can be irradiated at a Source-Surface Distance (SSD) of 20 cm at average dose rates of up to 600 Gy/s (3.3 Gy per 0.13 µs pulse, 180 pulses per second). In this mode multiple pulses are required for most irradiations. By modulating pulse repetition rate and irradiating at SSD = 171 cm, dose rates below 1 Gy/min can be achieved, allowing comparison of FLASH and conventional irradiations with the same beam. Operating in 6 MV photon mode, with the conversion target removed ( SuperFLASH mode), samples are irradiated at higher dose rates (0.2–150 Gy per 5 µs pulse, 360 pulses per second) and most irradiations can be performed with a single very high dose rate pulse. In both modes we have seen the expected inverse relation between dose rate and irradiated area, with the highest dose rates obtained for beams with a FWHM of about 2 cm and ± 10% uniformity over 1 cm diameter. As an example of operation of the ultra-high dose rate FLASH irradiator, we present dose rate dependence of dicentric chromosome yields.

43 PARTICLE ACCELERATORS↗

Extending deterministic transport capabilities for very-high and ultra-high energy electron beams

Focused Very-High Energy Electron (VHEE, 50–300 MeV) and Ultra-High Energy Electron (UHEE, > 300 MeV) beams can accurately target both large and deeply seated human tumors with high sparing properties, while avoiding the spatial requirements and cost of proton and heavy ion facilities. Advanced testing phases are underway at the CLEAR facilities at CERN (Switzerland), NLCTA at Stanford (USA), and SPARC at INFN (Italy), aiming to accelerate the transition to clinical application. Currently, Monte Carlo (MC) transport is the sole paradigm supporting preclinical trials and imminent clinical deployment. In this paper, we propose an alternative: the first extension of the nuclear-reactor deterministic chain Njoy-Dragon for VHEE and UHEE applications. We have extended the Boltzmann-Fokker-Planck (BFP) multigroup formalism and validated it using standard radio-oncology benchmarks, complex assemblies with a wide range of atomic numbers, and comprehensive irradiation of the entire periodic table. We report that 99% of water voxels exhibit a BFP-MC deviation below 2% for electron energies under 1.5 GeV. Additionally, we demonstrate that at least 97% of voxels of bone, lung, adipose tissue, muscle, soft tissue, tumor, steel, and aluminum meet the same criterion between 50 MeV and 1.5 GeV. For water, the thorax, and the breast intra-operative benchmark, typical average BFP-MC deviations of 0.3% and 0.4% were observed at 300 MeV and 1 GeV, respectively. By irradiating the entire periodic table, we observed similar performance between lithium (Z = 3) and cerium (Z = 58). Deficiencies observed between praseodymium (Z = 59) and einsteinium (Z = 99) have been reported, analyzed, and quantified, offering critical insights for the ongoing development of the Evaluated Nuclear Data File mode in NJOY.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FLASH-therapy suitable single-pulse proton generation using TiH 2 under nanosecond laser irradiation

We investigated proton emission from titanium hydride (TiH 2 ) targets irradiated in vacuum by a 6-ns, 1064-nm Nd:YAG laser. Time-of-flight measurements with a Faraday cup and an electrostatic ion analyzer resolved distinct proton peaks at high pulse energies, with yields on the order of 10 9 protons per shot. Systematic scans over pulse energy and up to 1000 repeated shots showed that, while the peak amplitude gradually decreased, the integrated proton number remained nearly constant. This behavior is consistent with surface-induced broadening of the plasma expansion while bulk hydrogen is replenished by diffusion and repeated ablation of fresh TiH 2 layers. Using the measured proton numbers and pulse widths, a simple direct-plasma-injection-style scaling indicates peak currents of ∼100 mA and sub-microsecond pulse durations. The pulse structure and yield satisfy key ultra-high-dose-rate criteria and, together with sustained output over 1000 shots, support TiH 2 -based laser ion sources as practical candidates for FLASH-therapy (ultra-high-dose-rate)-oriented studies and injector development using direct plasma injection.

43 PARTICLE ACCELERATORS↗

Beam characterization at NSRL for radiobiological experiments—phase 1

An experimental campaign was carried out at the NASA Space Radiation Laboratory to perform an additional, independent dosimetric characterization of the beams of protons, helium and carbon ions for radiobiological experiments. The campaign was undertaken by the request and with the support from the National Cancer Institute, U.S. In this initial phase, the goals were to obtain a first assessment of the dosimetric reproducibility of the beam control system, including analysis of spatial homogeneity and evaluation of ion beam contamination. They should facilitate the design of further experimental campaigns for beam characterization for radiobiological experiments. Measurements included reference dosimetry with comparison of in-house and external ionization chambers and electrometers, lateral-dose profile measurements in air, depth-dose profile in a water tank, evaluation of water equivalent thickness of a HDPE binary range shifter and estimation of impurities of the investigated helium-ion beam. The experiments and results are presented.

43 PARTICLE ACCELERATORS↗

Development of radiopharmaceuticals for targeted alpha therapy: Where do we stand?

Targeted alpha therapy is an oncological treatment, where cytotoxic doses of alpha radiation are locally delivered to tumor cells, while the surrounding healthy tissue is minimally affected. This therapeutic strategy relies on radiopharmaceuticals made of medically relevant radionuclides chelated by ligands, and conjugated to targeting vectors, which promote the drug accumulation in tumor sites. This review discusses the state-of-the-art in the development of radiopharmaceuticals for targeted alpha therapy, breaking down their key structural components, such as radioisotope, targeting vector, and delivery formulation, and analyzing their pros and cons. Moreover, we discuss current drawbacks that are holding back targeted alpha therapy in the clinic, and identify ongoing strategies in field to overcome those issues, including radioisotope encapsulation in nanoformulations to prevent the release of the daughters. Lastly, we critically discuss potential opportunities the field holds, which may contribute to targeted alpha therapy becoming a gold standard treatment in oncology in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗