Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

EVALUATION OF SILICON DIODES AS IN-SITU CRYOGENIC FIELD EMISSION DETECTORS FOR SRF CAVITY DEVELOPMENT

We performed in-situ cryogenic testing of four silicon diodes as possible candidates for field emission (FE) monitors of superconducting radio frequency (SRF) cavities during qualification testing and in accelerator cryo-modules. We evaluated diodes from 2 companies - from Hamamatsu corporation model S1223-01; and from OSI Optoelectronics models OSD35-LR-A, XUV-50C, and FIL-UV20. The measurements were done by placing the diodes in superfluid liquid helium near the top of a field emitting 9-cell cavity during its vertical test. For each diode, we will discuss their viability as a 2K cryogenic detector for FE mapping of SRF cavities and the directionality of S1223-01 in such environments. We will also present calibration curves between the diodes and JLab's standard radiation detector placed above the Dewar's top plate.

43 PARTICLE ACCELERATORS↗

Planetary-scan system

Mariner IV scanning system and radiation detector for locating and tracking Mars

MARINER IV SPACE PROBE↗

Note: Effect of photodiode aluminum cathode frame on spectral sensitivity in the soft x-ray energy band

Silicon photodiodes used for soft x-ray detection typically have a thin metal electrode partially covering the active area of the photodiode, which subtly alters the spectral sensitivity of the photodiode. As a specific example, AXUV4BST photodiodes from International Radiation Detectors have a 1.0 μm thick aluminum frame covering 19% of the active area of the photodiode, which attenuates the measured x-ray signal below ∼6 keV. This effect has a small systematic impact on the electron temperature calculated from measurements of soft x-ray bremsstrahlung emission from a high-temperature plasma. Although the systematic error introduced by the aluminum frame is only a few percent in typical experimental conditions on the Madison Symmetric Torus, it may be more significant for other instruments that use similar detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon bunching and the photon-noise-limited performance of infrared detectors

The photon-noise-limited performance of a radiation detector exposed to a thermal background of temperature T is analyzed by calculating the resulting specific detectivity. Both ideal photon detectors of arbitrary quantum efficiency eta and ideal thermal detectors of arbitrary emissivity eta are considered; and the effects of both shot noise and excess noise are taken into account. The relative contributions of these two sources depend on the quantum efficiency or emissivity of the system. For frequencies nu such that hnu/kT is much less than eta, excess noise can make an appreciable contribution to the total system noise. For the case of the detection of the narrow-band radiation, the specific detectivity is independent of eta in the limit hnu/kT is much less than eta.

Boyd, R. W.↗

Attribution of gamma-ray background collected by a mobile detector system to its surroundings using panoramic video

Mobile radiation detector systems are important tools for detecting radiological and nuclear sources outside of regulatory control, but due to their mobility, they are subject to complex and varying backgrounds in most realistic operational scenarios. Recent work has found correlations between non-radiological contextual information and gamma-ray spectral features that can be used to decrease false alarm rates, however a more complete understanding of background source terms has been elusive. A measurement campaign developed a full radiological characterization of a controlled facility that roughly corresponded to two city blocks. As part of the campaign, the Radiological Multi-sensor Analysis Platform (RadMAP) collected extensive multi-sensor data. In this work, RadMAP’s panoramic video data were used to visually identify several different materials and quantify the detector response to each material. A linear model was fit between the material responses and radiological features, and the results demonstrate reasonable agreement with ground truth flux measurements for each material. This paper will describe the data collection, processing, and analysis of the gamma-ray and video data from RadMAP. The paper will conclude with perspectives on the applicability of such a method to less controlled environments both with respect to achieving better understanding the sources of variability of background radiation in urban environments and whether such methods could be leveraged in operational scenarios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in imaging instrumentation for nuclear cardiology

Advances in imaging instrumentation and technology have greatly contributed to nuclear cardiology. Dedicated cardiac SPECT cameras incorporating novel, highly efficient detector, collimator, and system designs have emerged with the expansion of nuclear cardiology. Solid-state radiation detectors incorporating cadmium zinc telluride, which directly convert radiation to electrical signals and yield improved energy resolution and spatial resolution and enhanced count sensitivity geometries, are increasingly gaining favor as the detector of choice for application in dedicated cardiac SPECT systems. Additionally, hybrid imaging systems in which SPECT and PET are combined with X-ray CT are currently widely used, with PET/MRI hybrid systems having also been recently introduced. The improved quantitative SPECT/CT has the potential to measure the absolute quantification of myocardial blood flow and flow reserve. Rapid development of silicon photomultipliers leads to enhancement in PET image quality and count rates. In addition, the reduction of emission–transmission mismatch artifacts via application of accurate time-of-flight information, and cardiac motion de-blurring aided by anatomical images, are emerging techniques for further improvement of cardiac PET. This article reviews recent advances such as these in nuclear cardiology imaging instrumentation and technology, and the corresponding diagnostic benefits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Differences in the Impurity Ionization in Quasi-Classically Strong Constant and Alternating Electric Fields in a Two-Dimensional Superlattice Based on Graphene

The coefficient of the absorption of an electromagnetic wave in a two-dimensional superlattice based on graphene, in the presence of a constant electric field for the case of quasi-classically strong electric fields is investigated. The anisotropy of the absorption coefficient is revealed at different orientations of the vector of the constant electric field and the vector of polarization of the alternating electric field. It is demonstrated that the slow increase in the absorption coefficient at low frequencies is caused by impurity absorption, and its faster increase at higher frequencies is determined by miniband-to-miniband transitions. These peculiar properties can be used for the development of radiation detectors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Plural-wavelength flame detector that discriminates between direct and reflected radiation

A flame detector employs a plurality of wavelength selective radiation detectors and a digital signal processor programmed to analyze each of the detector signals, and determine whether radiation is received directly from a small flame source that warrants generation of an alarm. The processor's algorithm employs a normalized cross-correlation analysis of the detector signals to discriminate between radiation received directly from a flame and radiation received from a reflection of a flame to insure that reflections will not trigger an alarm. In addition, the algorithm employs a Fast Fourier Transform (FFT) frequency spectrum analysis of one of the detector signals to discriminate between flames of different sizes. In a specific application, the detector incorporates two infrared (IR) detectors and one ultraviolet (UV) detector for discriminating between a directly sensed small hydrogen flame, and reflections from a large hydrogen flame. The signals generated by each of the detectors are sampled and digitized for analysis by the digital signal processor, preferably 250 times a second. A sliding time window of approximately 30 seconds of detector data is created using FIFO memories.

Hall, Gregory H.↗

GaAs x-ray detectors with sub-nanosecond temporal response

Fast semiconductor radiation detectors operated in current mode provide a valuable diagnostic in pulsed power applications. Si detectors are common due to the availability of high-quality materials and mature fabrication processes, but they offer low absorption for hard x-rays above ∼10 keV. GaAs can provide increased hard x-ray absorption for the same detector volume due to a higher atomic number. GaAs photodiodes have been produced from epitaxial material grown at Sandia National Laboratories and fabricated at Sandia’s microfabrication facility. These detectors have significantly higher hard x-ray absorption (>10× at 15 keV) and nearly identical temporal impulse response to similarly sized Si detectors of 0.5 ns full-width half maximum.

Looker, Quinn (ORCID:0000000325820630)↗

Recovery of coincident frequency domain multiplexed detector pulses using sequential deconvolution

Multiplexing of radiation detector signals into a single channel significantly reduces the need for a large number of digitizer channels, which reduces the cost and the power consumption of a data acquisition system. We previously demonstrated frequency domain multiplexing by convolution using a prototype system that multiplexed two EJ-309 organic scintillators signals into a single channel. Each detector pulse was converted to a damped sinusoid which was then combined into a single channel. The combined signal was digitized and the original detector signal was recovered from the damped sinusoid by deconvolution. In this paper, we demonstrate the recovery of multiple detector signals that arrive during the same digitized record via a new sequential deconvolution method. Here, when two detectors produce signals in the same digitized record and their pulses do not overlap in time, we found that the charge, arrival time, and particle type can be estimated fairly precisely for the first pulse, but the second pulse exhibits substantial degradation in the precision of the estimated charge and arrival time. When the pulses overlap in time, we demonstrate both theoretically and experimentally that the part of the first pulse that does not overlap with the second can be recovered accurately, so the arrival time and amplitude of the first pulse can be estimated fairly precisely, but not the charge or particle type. None of these quantities can be estimated precisely for the second pulse when the two pulses overlap.

47 OTHER INSTRUMENTATION↗

Integration of the Kromek D3S Detector and Spot Robot For Secondary Inspections

Inspecting vehicles and containers for the presence of nuclear material is a challenging task for border control and security. When performed manually by inspectors, this task also has an associated risk of exposing the inspectors to unknown radiation. With the advent of agile, easy-to-program, quadruped robots like the Boston Dynamics Spot, automation of secondary inspection can improve the efficiency of the inspection process and alleviates the radiation risks to inspectors. In this project, Brookhaven National Laboratory and the University of Massachussetts at Lowell explored how to automate a simple secondary inspection mission. The Spot robot comes with its own software development kit (SDK) that allows clients/users to write custom code in the Python programming language to control the robot. Spot also has a payload computer called Spot-CORE, which runs the Ubuntu Linux operating system and allows users to integrate external sensors, such as a radiation detector, with Spot. In this study, the Kromek D3S detector has been integrated with Spot via the Spot-CORE, allowing Spot to capture gamma spectra and neutron counts for a specified acquisition period. Two custom routines, search and confirmation, have been developed and executed in this specified order. The search routine directs Spot to go around the nearest obstacle, e.g., vehicle and container, in a preset distance and step to collect gamma and neutron gross counts with the D3S detector. The radiation data and the robot location corresponding to each step are stored and fed to the confirmation routine at the end of the search. The confirmation routine then navigates Spot to the locations of the highest gamma or neutron counts to perform a long, e.g., one minute, measurement, and gives the operators the signature gamma spectra and neutron counts at the hotspots. This paper presents a detailed description of this automated system along with results of the preliminary tests in identifying the location and signature of a 137Cs radiation source in a vehicle.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Investigation of novel decay B _____ ____(2S)____K at BaBar

We investigate the undocumented B meson decay, B{sup +} {yields} {Psi}(2S){omega}K{sup +}. The data were collected with the BaBar detector at the SLAC PEP-II asymmetric-energy e{sup +}e{sup -} collier operating at the {gamma}(4S) resonance, a center-of-mass energy of 10.58 GeV/c{sup 2}. The {gamma}(4S) resonance primarily decays to pairs of B-mesons. The BaBar collaboration at the PEP-II ring was located at the SLAC National Accelerator Laboratory and was designed to study the collisions of positrons and electrons. The e{sup -}e{sup +} pairs collide at asymmetric energies, resulting in a center of mass which is traveling at relativistic speeds. The resulting time dilation allows the decaying particles to travel large distances through the detector before undergoing their rapid decays, a process that occurs in the in the center of mass frame over extremely small distances. As they travel through silicon vertex trackers, a drift chamber, a Cerenkov radiation detector and finally an electromagnetic calorimeter, we measure the charge, energy, momentum, and particle identification in order to reconstruct the decays that have occurred. While all well understood mesons currently fall into the qq model, the quark model has no a priori exclusion of higher configuration states such as qqqq which has led experimentalists and theorists alike to seek evidence supporting the existence of such states. Currently, there are hundreds of known decay modes of the B mesons cataloged by the Particle Data Group, but collectively they only account for approximately 60% of the B branching fraction and it is possible that many more exist.

36 MATERIALS SCIENCE↗

Evaluation of COTS Rad Detection Apps

Mobile applications are currently under distribution to smart phones utilizing the built-in charge coupled-device (CCD) camera as a radiation detector. The CCD detector has a very low but measurable gamma interaction cross section so the mechanism is feasible, especially for higher dose rate environments. Given that in a large release of radioactive material these ‘crowd sourced’ measurements will be put forth for consideration, a testing and evaluation of the accuracy and uncertainty of the Apps is a critical endeavor. Not only is the accuracy of the reported measurement of concern to the immediate user’s safety, a quantitative uncertainty is required for a government response such as the Federal Radiological Monitoring and Assessment Center (FRMAC) to accept the values for consideration in the determination of regions exceeding protective action guidelines. Already, prompted by the Fukushima nuclear material releases, several repositories of this crowd-sourced data have been created (http://japan.failedrobot.com, http://www.stubbytour.com/nuc/index_en.asp, and http://www.rdtn.org) although the question remains as to the reliability of measurements incorporated into these repositories. In cases of conflict between the real-time published crowd-sourced data and governmental protective actions prepared literature should be on-hand documenting why the difference, if any, exists. Four applications for iOS devices were obtained along with hardware to benchmark their performance. Gamma/X-Ray Detector by Stephan Hotto, Geiger Camera by Senscare, and RadioactivityCounter App by Hotray LTD are all the applications available for distribution within the US that utilize the CCD camera sensor for detection of radiation levels. The CellRad app under development by Idaho National Laboratory for the Android platform was evaluated. In addition, iRad Geiger with the associated hardware accessory was also benchmarked. Radiation fields were generated in a Cs-137 JL Shepherd Model 89 shielded calibration range. The accuracy of the exposure rate within the box calibrator is +/- 5% of the system settings and NIST traceable. This is the same calibration unit utilized for calibration of US DOE exposure rate meters. Measurements were performed from 0.2 to 40,000 mR/hr. Included in the following sections are discussions on each of the evaluated applications and their performance in reporting radiation field measurements. Unfortunately the applications do not provide a readily identifiable quality of the measurement in order to produce error bars or even out of range conditions. In general all the CCD based applications had issues detecting consistent measurements in radiation fields less than 5 mR/hr. This is most likely attributable to the electronic noise level on the CCD’s becoming comparable to the signal level due to the ionizing radiation photons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge carrier mobility of halide perovskite single crystals for ionizing radiation detection

Halide perovskites have recently emerged as promising semiconductor materials for several applications including solar cells, light-emitting diodes (LEDs), and radiation detectors. The charge carrier transport properties, which could be evaluated by the mobility-lifetime (mu-tau or μ-г) product, serve an important role for the development of halide perovskites for radiation detection applications. In this perspective, we firstly explain the charge transport mechanism and the limiting factors that determine the intrinsic charge carrier mobility in halide perovskite single crystals. Then, we overview the techniques and methods that have been employed for evaluating the charge carrier mobility (for both electrons and holes). Lastly, we discuss the discrepancy between the experimentally determined carrier mobility from the literature for halide perovskite single crystals and a perspective on future developments for carrier mobility enhancement is provided.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-rays from a microsecond X-pinch

The characteristics of x-rays emitted by X-pinches driven by discharging a current of ∼320 kA with a quarter period of 1 μs in crossed 25 μm wires have been investigated. The x-ray emissions are studied using filtered silicon photodiodes, diamond radiation detectors, and pinhole cameras. The results show that predominantly x-rays from the microsecond X-pinch tend to be emitted in two distinct sets of bursts. The first is predominantly “soft,” i.e., with photon energy hν < 5 keV, followed by a second set of bursts beginning up to 100 ns following the initial bursts, and usually consisting of higher photon energies. Our results show, however, that the x-ray emissions do not contain a significant component with hν > 10 keV as might be expected from electron beam activity within the plasma or from the X-pinch diode. High-resolution images obtained with the observed x-rays suggest a well-defined small source of soft x-rays that demonstrates the potential of the microsecond X-pinch.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗