Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “R MATRIX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Observation Error Specification for Near-Surface Soil Moisture Assimilation: Does It Matter?

The observation error variances assumed in the data assimilation (DA) of remotely sensed near-surface soil moisture observations are known to have unrealistic spatial patterns. The temporal variability in the errors is also typically neglected. Soil moisture errors cannot be directly calculated at large scales, and the globally distributed errors are unknown. We apply several approaches to estimating the observation errors (R matrix) for near-surface soil moisture DA experiments, to establish whether the assumed errors are important to the DA performance, and hence whether uncertainty in the observation error specification is a likely source of uncertainty in soil moisture DA output.

Draper, Clara↗

State estimation of an acid gas removal (AGR) plant as part of an integrated gasification combined cycle (IGCC) plant with CO2 capture

An accurate estimation of process state variables not only can increase the effectiveness and reliability of process measurement technology, but can also enhance plant efficiency, improve control system performance, and increase plant availability. Future integrated gasification combined cycle (IGCC) power plants with CO2 capture will have to satisfy stricter operational and environmental constraints. To operate the IGCC plant without violating stringent environmental emission standards requires accurate estimation of the relevant process state variables, outputs, and disturbances. Unfortunately, a number of these process variables cannot be measured at all, while some of them can be measured, but with low precision, low reliability, or low signal-to-noise ratio. As a result, accurate estimation of the process variables is of great importance to avoid the inherent difficulties associated with the inaccuracy of the data. Motivated by this, the current paper focuses on the state estimation of an acid gas removal (AGR) process as part of an IGCC plant with CO2 capture. This process has extensive heat and mass integration and therefore is very suitable for testing the efficiency of the designed estimators in the presence of complex interactions between process variables. The traditional Kalman filter (KF) (Kalman, 1960) algorithm has been used as a state estimator which resembles that of a predictor-corrector algorithm for solving numerical problems. In traditional KF implementation, good guesses for the process noise covariance matrix (Q) and the measurement noise covariance matrix (R) are required to obtain satisfactory filter performance. However, in the real world, these matrices are unknown and it is difficult to generate good guesses for them. In this paper, use of an adaptive KF will be presented that adapts Q and R at every time step of the algorithm. Results show that very accurate estimations of the desired process states, outputs or disturbances can be achieved by using the adaptive KF.

97 MATHEMATICS AND COMPUTING↗

New Resolved Resonance Region Evaluation for 63Cu and 65Cu for Nuclear Criticality Safety Program

A new resolved resonance region evaluation of 63Cu and 65Cu was done in the energy region from 10-5 eV to 99.5 keV. The R-Matrix SAMMY method using the Reich-Moore approximation was used to create a new set of consistent resonance parameters. The new evaluation was based on three experimental transmission data sets; two measured at ORELA and one from MITR, and two radiative capture experimental data sets from GELINA. A total of 141 new resonances were identied for 63Cu and 117 for 65Cu. The corresponding set of external resonances for each isotope was based on the identied resonances above 99.5 keV from the ORELA transmission data. The negative external levels (bound levels) were determined to match the dierential thermal cross section measured at the MITR. Double dierential elastic scattering cross sections were calculated from the new set of resonance parameters. Benchmarking calculations were carried out on a set of ICSBEP benchmarks. This work is in support of the DOE Nuclear Criticality Safety Program.

Sobes, Vladimir↗

Evaluation of Tungsten Neutron Cross Sections in the Resolved Resonance Regions

We generated a preliminary set of resonance parameters for 182-184,186W in the neutron energy range of thermal up to several keV. The evaluation methodology uses the Reich-Moore approximation to t, with the R-matrix code SAMMY, the high-resolution measurements performed in 2010 and 2012 at the GEel LINear Accelerator (GELINA) facility. Particularly for 183W, the transmission data and the capture cross sections calculated with the set of resonance parameters are compared with the experimental values, and some of the average properties of the resonance parameters are discussed. In the analyzed energy range, this work almost doubles the existing resolved resonance evaluations in the ENDF/B-VII.1 library. The analysis of the performance of the calculated cross sections based on criticality benchmarks is still in progress and it is only briefly discussed.

Pigni, Marco T↗

Benchmark Testing of a New 56 Fe Evaluation for Criticality Safety Applications

The SAMMY code was used to evaluate resonance parameters of the 56 Fe cross section in the resolved resonance energy range of 0–2 MeV using transmission data, capture, elastic, inelastic, and double differential elastic cross sections. The resonance analysis was performed with the code SAMMY that fits R-matrix resonance parameters using the generalized least-squares technique (Bayes’ theory). The evaluation yielded a set of resonance parameters that reproduced the experimental data very well, along with a resonance parameter covariance matrix for data uncertainty calculations. Benchmark tests were conducted to assess the evaluation performance in benchmark calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bayesian Monte Carlo Evaluation Framework for Imperfect Data and Models [Abstract]

Nuclear data evaluation methods conventionally make the following assumptions: prior and posterior probability distribution functions (PDFs) of all model parameters and data are normal (Gaussian); the linear approximation is sufficiently accurate for minimization of a cost function (even for non-linear models); and that both the model (of, e.g., neutron cross section) and experimental data (including their covariance data) are perfect. These assumptions are inherent to the well-known generalized linear least squares (GLLS) minimization method commonly used for evaluations of resolved resonance region (RRR) neutron cross sections. However, these assumptions are often not justified due to the presence of non-normal PDFs, non-linear models (e.g. R -matrix formalism), and inherent imperfections in data and models (e.g. discrepant data sets, discrepancies between the previous evaluation and newly measured data, or imperfect covariance data). We remove the said assumptions in a mathematical framework of Bayes’ theorem, and implement it using the Metropolis-Hastings Monte Carlo method. Parameters of a new kind are introduced to parameterize inherent imperfections, e.g. , any discrepancies between the theoretical model and measured data. These new parameters enable evaluators to quantify their expert judgement about any discrepancies or imperfections in a reproducible manner. We demonstrate the framework with an ongoing evaluation of 233 U in the eV region using the ENDF-B/VIII library and transmission data measured by Guber, et al. , and compare the posterior parameters to those obtained by conventional evaluation methods.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Updates and Validation for the n+ 63,65 Cu Cross Sections [Abstract]

The neutron induced total, elastic, and capture cross sections of 63,65 Cu isotopes were selected for evaluation in the resolved and unresolved resonance energy ranges by the National Criticality Safety Program to resolve discrepancies related to benchmark performance. This is especially evident for the series of ZEUS benchmarks in which copper is used as a reflector. Because copper is also used as structural material in both fission and fusion reactors, the need to address benchmark discrepancies linked to nuclear data deficiencies is a task of primary importance. The aim of this work is to describe the steps of evaluation work towards a consistent improvement of the benchmark performance. The R-matrix analysis with the SAMMY code focused on the 63 Cu(n,γ) reaction channel between 100-300 keV coupled to unresolved resonance region parameters up to 650 keV to fit average cross section data from a recent experiment. Due to the high sensitivity of many benchmarks to elastic scattering angular distribution data, especially for the 65 Cu isotope, the impact of these data was tested by generating Legendre coefficients from both resonance parameters and the Hauser-Feshbach model. Guided by the findings of Shaw et al., the performance of the current evaluation for 65 Cu was compared to that of ENDF/B-VII.1 and ENDF/B-VIII.0 by testing the reactivity coefficients corresponding to the validation suite of experimental criticality benchmarks for thermal, intermediate, and fast systems taken from the International Criticality Safety Benchmark Experiments Project Handbook. The benchmark performance is especially sensitive to 63 Cu(n,γ) and 65 Cu elastic scattering for neutron energies in the 100–500 keV region, whereas 100 keV is the upper limit of the resolved resonance region in the ENDF/B-VIII.0 evaluations for 63,65 Cu. The results highlight the need to handle the transition from the resolved resonance region to the high energy region carefully.

07 ISOTOPE AND RADIATION SOURCES↗

Finalizing the {sup 63}Cu and {sup 65}Cu Resonance Evaluations for the ENDF/B-VIII Release

The resolved resonance region evaluation for the only two natural isotopes of copper ({sup 63}Cu and {sup 65}Cu) was carried out at the Oak Ridge National Laboratory (ORNL) in support of the US Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). The particular interest in the isotope of copper arose because it was linked with poor performance of the Zeus series of integral benchmarks from the International Criticality Safety Benchmark Evaluation Project (ICSBEP). Good agreement between the calculated and experimentally measured values for the ICSBEP benchmarks is essential to the NCSP because the ICSBEP benchmarks are used for validation purposes of criticality safety calculations. The particular set of four Zeus experiments had a highly-enriched uranium core with a thick copper-reflector resulting in a large sensitivity of the criticality of these systems to the cross section of copper in the intermediate energy range. Sobes et al. presented the effect of the newly resolved resonance region evaluations for the two isotopes of copper on the Zeus integral benchmarks, as well as 23 other benchmarks from the ICSBEP during the 2016 ANS Annual Meeting. The results presented in Ref. were calculated with the ENDF/B-VII.1 cross section libraries used for all other materials. However, it is suggested that the resolved resonance region evaluations for the isotopes of copper should not be judged only on their performance in the integral benchmark calculations especially when the ENDF/B-VII.1 cross sections are used for all of the other isotopes. Three reasons are provided for this. First and foremost, a new evaluation is an assessment of the physics of the nucleus of the particular isotope, and the goal of an application agnostic nuclear data evaluation is to improve evaluation by fitting state-of-the art R-Matrix formalism to highly precise experimental cross section measurements. The improved performance in the integral benchmarks should only come as a consequence of the improvement in the physics of the evaluation. Secondly, there is some uncertainty in the nuclear data evaluation of the cross section of all isotopes, so there could be some error in evaluating another isotope used in calculating the integral benchmark experiment. Such an error may have been having a compensating effect, in combination with the previous evaluations for the isotopes of copper. Thirdly, with the two isotopes of copper proposed for inclusion in the upcoming release of the ENDF/B-VIII library, performance of the new resonance evaluation for copper should be evaluated based on the calculation of the integral benchmarks with all of the evaluations proposed for inclusion in the ENDF/B-VIII release. These benchmarking results using the ENDF/B-VIII evaluations as they converge closer to their final form will be presented at the conference. This summary stresses the importance of the physics of the evaluation and reviews some of the steps taken in finalizing a resolved resonance region evaluation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multilevel Algorithm for Atmospheric Data Assimilation

A multiscale algorithm for the problem of optimal statistical interpolation of observed data has been developed. This problem includes the calculation of the vector of the 'analyzed' (best estimated) atmosphere flow field w(sup a) by the formula: w(sup a) = w(sup f) + P(sup f) H(sup T) y, where the quantity y is defined by the equation (H P(sup f) H(sup T) + R)y = w(sup o) - H w(sup f), using the given model forecast first guess w(sup f) and the vector of observations w(sup o); H is an interpolation operator from the regular grid to the observation network, P(sup f) is the forecast error covariance matrix, and R is the observation error covariance matrix. At this initial stage the case of univariate analysis of single level radiosonde height data is considered. The matrix R is assumed to be diagonal, and the matrix P(sup f) is assumed to be given by the formula P(sub ij)(sup f) = sigma(sub i)(sup f) mu(sub ij) sigma(sub j)(sub f), where mu(sub ij) is a smooth, decreasing function of the distance between the i-th and the j-th points. In this paper we describe a multiscale iterative process based on a multiresolution, simultaneous displacement technique and a localized variational calculation of iteration parameters.

Brandt, Achi↗

Design of an achromatic and uncoupled medical gantry for radiation therapy

We are presenting the layout and the optics of a beam line to be used as a medical gantry in radiation therapy. The optical properties of the gantry's beam line are such as to make the beam line achromatic and uncoupled. These two properties make the beam spot size, which is delivered and focused by the gantry, on the tumor of the patient, independent of the angular orientation of the gantry. In this paper we present the layout of the magnetic elements of the gantry, and also present the theoretical basis for the optics design of such a gantry. A medical gantry, as it is used in the radiation treatment of cancer patients, is the last part of the beam optical system, of the accelerator complex, which delivers and focuses the beam on the tumor. The curved line shown in figure 1 is a schematic diagram of a gantry which can rotate about a horizontal axis. The particle beam (green arrow in fig. 1) enters the gantry, and is guided by the gantry on the tumor (red spot in fig. 1). As the gantry rotates about the axis shown in figure 1, the beam exiting the gantry always lies on a plane normal to the rotation axis at the point of the icocenter. Thus the gantry facilitates the ability of the beam delivery system, to deliver the beam at the tumor, which is placed at the icocenter, from any angle on this vertical plane, which is normal to the rotation angle of the gantry as stated earlier. The gantry consists of dipoles and quadrupoles elements whose median symmetry plane lies on a plane which contains the rotation axis of the gantry. In this paper we define this plane as the 'plane of the gantry'. As the beam is transported along the axis of rotation of the gantry and before it enters the gantry, it is focused by 'normal' quadrupoles and experiences no linear beam coupling. Subsequently the beam enters the gantry, and is transported by the gantry to the delivery point which is the tumor. The transported beam at the tumor is still linearly uncoupled as long as the plane of the gantry lies either, on the horizontal, or the vertical plane. In these two orientations of the gantry the dipoles and the quadrupoles are 'normal' therefore the linear R-transport-matrix appears linearly uncoupled. As the gantry rotates about this horizontal axis, to irradiate the tumor at a different angle, the linear beam coupling is unavoidable since the coordinate system of the gantry's quadrupoles is rotated with respect to the coordinate system of the quadrupoles at the entrance of the gantry which are located along the axis of rotation. As a result, in this rotated coordinate system, the beam will be linearly coupled as it is transported by the gantry to the tumor and the beam size at the location of the tumor will vary in size depending on the orientation of the gantry. In this paper we present a method which makes the beam transport R-matrix linearly uncoupled, achromatic and independent of the orientation angle of the gantry as is proven in the following section.

43 PARTICLE ACCELERATORS↗

Status of the n+ 35 Cl Cross Sections [Slides]

In the recently released ENDF/B-VIII.0 library, the 35 Cl(n,p) cross section above 100 keV significantly differs from the ENDF/B-VII.0 library. This resulted in large differences in the predicted reactivity in nuclear reactor simulations. The lack of experimental data for incident neutron energies above 100 keV does not allow a precise evaluation of the 35 Cl(n,p) reaction channel. Evaluation of 35 Cl(n,p) cross section was included as one of the highest priorities in recent DOE calls for proposals within the Nuclear Data Interagency Working Group / Research Program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Distributed non-equilibrium Green’s function algorithms for the simulation of nanoelectronic devices with scattering

Through the non-equilibrium Green’s function (NEGF) formalism, quantum-scale device simulation can be performed with the inclusion of electron-phonon scattering. Yet, the simulation of realistically sized devices under the NEGF formalism typically requires prohibitive amounts of memory and computation time. Two of the most demanding computational problems for NEGF simulation involve mathematical operations with structured matrices called semiseparable matrices. In this work, we present parallel approaches for these computational problems which allow for efficient distribution of both memory and computation based upon the underlying device structure. This is vital when simulating realistically sized devices due to the aforementioned computational burdens. First, we consider determining a distributed compact representation for the retarded Green’s function matrix G R . This compact representation is exact and allows for any entry in the matrix to be generated through the inherent semiseparable structure. The second parallel operation allows for the computation of electron density and current characteristics for the device. Specifically, matrix products between the distributed representation for the semiseparable matrix G R and the self-energy scattering terms in Σ < produce the less-than Green’s function G < . As an illustration of the computational efficiency of our approach, we stably generate the mobility for nanowires with cross-sectional sizes as large as 4.5 nm, assuming an atomistic model with scattering.

47 OTHER INSTRUMENTATION↗

Practical auxiliary basis implementation of Rung 3.5 functionals

Approximate exchange-correlation functionals for Kohn-Sham density functional theory often benefit from incorporating exact exchange. Exact exchange is constructed from the noninteracting reference system's nonlocal one-particle density matrix γ(r{sup -vector},r{sup -vector}′). Rung 3.5 functionals attempt to balance the strengths and limitations of exact exchange using a new ingredient, a projection of γ(r{sup -vector},r{sup -vector} ′) onto a semilocal model density matrix γ{sub SL}(ρ(r{sup -vector}),∇ρ(r{sup -vector}),r{sup -vector}−r{sup -vector} ′). γ{sub SL} depends on the electron density ρ(r{sup -vector}) at reference point r{sup -vector}, and is closely related to semilocal model exchange holes. We present a practical implementation of Rung 3.5 functionals, expanding the r{sup -vector}−r{sup -vector} ′ dependence of γ{sub SL} in an auxiliary basis set. Energies and energy derivatives are obtained from 3D numerical integration as in standard semilocal functionals. We also present numerical tests of a range of properties, including molecular thermochemistry and kinetics, geometries and vibrational frequencies, and bandgaps and excitation energies. Rung 3.5 functionals typically provide accuracy intermediate between semilocal and hybrid approximations. Nonlocal potential contributions from γ{sub SL} yield interesting successes and failures for band structures and excitation energies. The results enable and motivate continued exploration of Rung 3.5 functional forms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recursive Factorization of the Inverse Overlap Matrix in Linear Scaling Quantum Molecular Dynamics Simulations

We present a reduced complexity algorithm to compute the inverse overlap factors required to solve the generalized eigenvalue problem in a quantum-based molecular dynamics (MD) simulation. Our method is based on the recursive iterative re nement of an initial guess Z of the inverse overlap matrix S. The initial guess of Z is obtained beforehand either by using an approximate divide and conquer technique or dynamically, propagated within an extended Lagrangian dynamics from previous MD time steps. With this formulation, we achieve long-term stability and energy conservation even under incomplete approximate iterative re nement of Z. Linear scaling performance is obtained using numerically thresholded sparse matrix algebra based on the ELLPACK-R sparse matrix data format, which also enables e cient shared memory parallelization. As we show in this article using selfconsistent density functional based tight-binding MD, our approach is faster than conventional methods based on the direct diagonalization of the overlap matrix S for systems as small as a few hundred atoms, substantially accelerating quantum-based simulations even for molecular structures of intermediate size. For a 4,158 atom water-solvated polyalanine system we nd an average speedup factor of 122 for the computation of Z in each MD step.

36 MATERIALS SCIENCE↗

Generating Ultrashort Coherent Soft X-ray Radiation in Storage Rings Using Angular-modulated Electron Beams

A technique is proposed to generate ultrashort coherent soft x-ray radiation in storage rings using angular-modulated electron beams. In the scheme a laser operating in the TEM01 mode is first used to modulate the angular distribution of the electron beam in an undulator. After passing through a special beam line with non-zero transfer matrix element R{sub 54}, the angular modulation is converted to density modulation which contains considerable higher harmonic contents of the laser. It is found that the harmonic number can be one or two orders of magnitude higher than the standard coherent harmonic generation method which relies on beam energy modulation. The technique has the potential of generating femtosecond coherent soft x-ray radiation directly from an infrared seed laser and may open new research opportunities for ultrafast sciences in storage rings.

43 PARTICLE ACCELERATORS↗