SU-B-BRF-01: Professional Council Symposium: The Evolving US Healthcare Delivery Model, How Will the Medical Physics Profession Be Impacted and How Should We Respond?

The United States' healthcare delivery model is undergoing significant change. Insurance and reimbursement models are rapidly evolving, federal allocations are shifting from specialty services to preventive and generalpractice services, and Accountable Care Organizations are gaining in prominence. One area of focus is on the perceived over-utilization of expensive services such as advanced imaging and, in some cases, radiation therapy. Reimbursement incentives are increasingly aimed at quality metrics, leading to an increased interest in the core concepts of High Reliability Organizations. With the shift in federal resources away from specialty services and the increasing prominence of Accountable Care Organizations, we will likely be challenged to re-assess our traditional model for delivering medical physics services. Medical physicists have a unique combination of education and training in physics principles, radiation physics applications in medicine, human anatomy, as well as safety analysis and quality control methods. An effective medical physicist recognizes that to advance the institution's mission, the medical physicist must join other professional leaders within the institution to provide clear direction and perspective for the entire team. To do that, we must first recognize the macro changes in our healthcare delivery system and candidly assess how the medical physics practice model can evolve in a prudent way to support the institution's objectives while maintaining the traditionally high level of quality and safety. This year's Professional Council Symposium will explore the many facets of the changing healthcare system and its potential impact on medical physics. Dr. Shine will provide an overview of the developing healthcare delivery and reimbursement models, with a focus on how the physician community has adapted to the changing objectives. Mr. White will describe recent changes in the reimbursement patterns for both imaging and radiation therapy services, the underlying imperatives that will influence additional changes in the near-term future, and the broader changes in the medical physics workforce that may arise due to many (often conflicting) directives and incentives both internal and external to the profession. Maintaining the integrity of the medical physics profession and the high quality of medical physics services will require a shared understanding of the changing practice environment and a firm commitment to protecting the key priorities of clinical medical physics as the healthcare system transitions to a new and very different model. To be effective as medical physicists, we must learn how to provide leadership in our respective institutions. Learning Objectives: Understand the macro changes occurring in the US healthcare delivery system. Understand the likely near-term, and possible longer-term, impact on the medical physics profession. Understand some strategies for providing leadership during this period of significant change.

07 ISOTOPE AND RADIATION SOURCES↗

Cultured cardiac fibroblasts and myofibroblasts express Sushi Containing Domain 2 and assemble a unique fibronectin rich matrix

Highlights: • Cultured cardiac fibroblasts and myofibroblasts derived from normal human hearts express the novel marker SUSD2. • Under high density culture conditions, human cardiac myofibroblasts deposit a matrix scaffold rich in fibronectin. • Cultured dermal fibroblasts do not express SUSD2 and did not for form scaffolds in vitro. Cardiac fibroblasts and myofibroblasts assemble and maintain extracellular matrix during normal development and following injury. Culture expansion of these cells yield a bioengineered matrix that could lead to intriguing therapeutic opportunities. For example, we reported that cultured rat cardiac fibroblasts form a matrix that can be used to delivery therapeutic stem cells. Furthermore, we reported that matrix derived from cultured human cardiac fibroblasts/myofibroblasts converted monocytes into macrophages that express interesting anti-inflammatory and pro-angiogenic properties. Expanding these matrix investigations require characterization of the source cells for quality control. In these efforts, we observed and herein report that Sushi Containing Domain 2 (SUSD2) is a novel and consistent marker for cultured human cardiac fibroblast and myofibroblasts.

60 APPLIED LIFE SCIENCES↗

The Microbase Value-Added Product: A Baseline Retrieval of Cloud Microphysical Properties

This report describes the Atmospheric Radiation Measurement (ARM) Climate Research Facility baseline cloud microphysical properties (MICROBASE) value-added product (VAP). MICROBASE uses a combination of millimeter-wavelength cloud radar, microwave radiometer, and radiosonde observations to estimate the vertical profiles of the primary microphysical parameters of clouds including the liquid/ice water content and liquid/ice cloud particle effective radius. MICROBASE is a baseline algorithm designed to apply to most conditions and locations using a single set of parameterizations and a simple determination of water phase based on temperature. This document provides the user of this product with guidelines to assist in determining the accuracy of the product under certain conditions. Quality control flags are designed to identify outliers and indicate instances where the retrieval assumptions may not be met. The overall methodology is described in this report through a detailed description of the input variables, algorithms, and output products.

54 ENVIRONMENTAL SCIENCES↗

Raman Lidar Profiles Best Estimate Value-Added Product Technical Report

The ARM Raman lidars are semi-autonomous ground-based systems that transmit at a wavelength of 355 nm with 300 mJ, ~5 ns pulses, and a pulse repetition frequency of 30Hz. Signals from the various detection channels are processed to produce time- and height-resolved estimates of several geophysical quantities, such as water vapor mixing ratio, relative humidity, aerosol scattering ratio, backscatter, optical depth, extinction, and depolarization ratio. Data processing is currently handled by a suite of six value-added product (VAP) processes. Collectively, these processes are known as the Raman Lidar Profiles VAP (RLPROF). The top-level best-estimate (BE) VAP process was introduced in order to bring together the most relevant information from the intermediate-level VAPs. As such, the BE process represents the final stage in data processing for the Raman lidar. Its principal function is to extract the primary variables from each of the intermediate-level VAPs, perform additional quality control, and combine all of this information into a single output file for the end-user. The focus of this document is to describe the processing performed by the BE VAP process.

54 ENVIRONMENTAL SCIENCES↗

Methods Used to Calculate Doses Resulting from Inhalation of Capstone Depleted Uranium Aerosols

The methods used to calculate radiological and toxicological doses to hypothetical persons inside either a United States Army Abrams tank or Bradley Fighting Vehicle that has been perforated by depleted uranium munitions is described. Data from time- and particle-size-resolved measurements of depleted uranium aerosol as well as particle-size resolved measurements of aerosol solubility in lung fluids for aerosol produced in the breathing zones of the hypothetical occupants were used. The aerosol was approximated as a mixture of nine monodisperse (single particle size) components corresponding to particle size increments measured by the eight stages plus backup filter of the cascade impactors used. A Markov Chain Monte Carlo Bayesian analysis technique was employed, which straightforwardly calculates the uncertainties in doses. Extensive quality control checking of the various computer codes used is described.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-rate x-ray spectroscopy in mammography with a CdTe detector: A digital pulse processing approach

Purpose:Direct measurement of mammographic x-ray spectra under clinical conditions is a difficult task due to the high fluence rate of the x-ray beams as well as the limits in the development of high resolution detection systems in a high counting rate environment. In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate x-ray spectroscopy in mammography. Methods: The DPP system performs a digital pile-up inspection and a digital pulse height analysis of the detector signals, digitized through a 14-bit, 100 MHz digitizer, for x-ray spectroscopy even at high photon counting rates. We investigated on the response of the digital detection system both at low (150 cps) and at high photon counting rates (up to 500 kcps) by using monoenergetic x-ray sources and a nonclinical molybdenum anode x-ray tube. Clinical molybdenum x-ray spectrum measurements were also performed by using a pinhole collimator and a custom alignment device. Results: The detection system shows excellent performance up to 512 kcps with an energy resolution of 4.08% FWHM at 22.1 keV. Despite the high photon counting rate (up to 453 kcps), the molybdenum x-ray spectra, measured under clinical conditions, are characterized by a low number of pile-up events. The agreement between the attenuation curves and the half value layer values, obtained from the measured spectra, simulated spectra, and from the exposure values directly measured with an ionization chamber, also shows the accuracy of the measurements. Conclusions: These results make the proposed detection system a very attractive tool for both laboratory research and advanced quality controls in mammography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual-headed SPECT for awake animal brain imaging

Motion-corrected awake animal imaging is needed for normal-state investigations of models of neurological disease and brain activity. The awake animal brain SPECT/CT system, AwakeSPECT at Johns Hopkins University has in the past used a single gamma camera for imaging. Enhancements have been made by adding a pinhole collimator to the second gamma camera at the opposite side which has been previously equipped parallel hole collimator. Geometry calibration was performed using a custom built quality control phantom containing three Co-57 point sources and applied to the tomographic reconstruction code. Hot-rod phantom scans with Tc-99m were performed to test sensitivity and resolution improvements. The reconstruction results show significant resolution and sensitivity improvements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low background techniques applied in the BOREXINO experiment

The BOREXINO detector, located in the Gran Sasso National Laboratory in Italy, has been designed for real-time spectroscopy of low-energy solar neutrinos. Within the experiment several novel background reduction and assay techniques have been established. In many cases they are still the most sensitive world-wide. Developed methods and apparatus provided tools for a strict quality control program during the construction phase of the BOREXINO detector, which was the key to meet the background requirements. Achievement of extremely low background rate opened the possibility to probe in realtime almost entire spectrum of the solar neutrinos.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermoluminescent Dosimeter Use for Environmental Surveillance at the Hanford Site, 1971–2005

This report describes the use of thermo luminescent dosimeters for environmental surveillance of external radiation on and around the Hanford Site for the period of 1970 to 2005. It addresses changes in the technology and associated quality control and assurance used in this work and summarizes the results of the 35 year period of external radiation surveillance. The appendices to this report provide trend plots for each location that comprised the shoreline, onsite, perimeter, and offsite sample design.

54 ENVIRONMENTAL SCIENCES↗

Specific recommendations for accurate and direct use of PET-CT in PET guided radiotherapy for head and neck sites

Purpose: To provide specific experience-based guidance and recommendations for centers wishing to develop, validate, and implement an accurate and efficient process for directly using positron emission tomography-computed tomography (PET-CT) for the radiotherapy planning of head and neck cancer patients. Methods: A PET-CT system was modified with hard-top couch, external lasers and radiotherapy immobilization and indexing devices and was subject to a commissioning and quality assurance program. PET-CT imaging protocols were developed specifically for radiotherapy planning and the image quality and pathway tested using phantoms and five patients recruited into an in-house study. Security and accuracy of data transfer was tested throughout the whole data pathway. The patient pathway was fully established and tested ready for implementation in a PET-guided dose-escalation trial for head and neck cancer patients. Results: Couch deflection was greater than for departmental CT simulator machines. An area of high attenuation in the couch generated image artifacts and adjustments were made accordingly. Using newly developed protocols CT image quality was suitable to maintain delineation and treatment accuracy. Upon transfer of data to the treatment planning system a half pixel offset between PET and CT was observed and corrected. By taking this into account, PET to CT alignment accuracy was maintained below 1 mm in all systems in the data pathway. Transfer of structures delineated in the PET fusion software to the radiotherapy treatment planning system was validated. Conclusions: A method to perform direct PET-guided radiotherapy planning was successfully validated and specific recommendations were developed to assist other centers. Of major concern is ensuring that the quality of PET and CT data is appropriate for radiotherapy treatment planning and on-treatment verification. Couch movements can be compromised, bore-size can be a limitation for certain immobilization techniques, laser positioning may affect setup accuracy and couch deflection may be greater than scanners dedicated to radiotherapy. The full set of departmental commissioning and routine quality assurance tests applied to radiotherapy CT simulators must be carried out on the PET-CT scanner. CT image quality must be optimized for radiotherapy planning whilst understanding that the appearance will differ between scanners and may affect delineation. PET-CT quality assurance schedules will need to be added to and modified to incorporate radiotherapy quality assurance. Methods of working for radiotherapy and PET staff will change to take into account considerations of both parties. PET to CT alignment must be subject to quality control on a loaded and unloaded couch preferably using a suitable emission phantom, and tested throughout the whole data pathway. Data integrity must be tested throughout the whole pathway and a system included to verify that delineated structures are transferred correctly. Excellent multidisciplinary team communication and working is vital, and key staff members on both sides should be specifically dedicated to the project. Patient pathway should be clearly devised to optimize patient care and the resources of all departments. Recruitment of a cohort of patients into a methodology study is valuable to test the quality assurance methods and pathway.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Japanese Structure Survey of Radiation Oncology in 2005 Based on Institutional Stratification of Patterns of Care Study

Purpose: To evaluate the structure of radiation oncology in Japan in terms of equipment, personnel, patient load, and geographic distribution to identify and improve any deficiencies. Methods and Materials: A questionnaire-based national structure survey was conducted between March 2006 and February 2007 by the Japanese Society of Therapeutic Radiology and Oncology. These data were analyzed in terms of the institutional stratification of the Patterns of Care Study. Results: The total numbers of new cancer patients and total cancer patients (new and repeat) treated with radiotherapy in 2005 were estimated at approximately 162,000 and 198,000, respectively. In actual use were 765 linear accelerators, 11 telecobalt machines, 48 GammaKnife machines, 64 {sup 60}Co remote-controlled after-loading systems, and 119 {sup 192}Ir remote-controlled after-loading systems. The linear accelerator systems used dual-energy function in 498 systems (65%), three-dimensional conformal radiotherapy in 462 (60%), and intensity-modulated radiotherapy in 170 (22%). There were 426 Japanese Society of Therapeutic Radiology and Oncology-certified radiation oncologists, 774 full-time equivalent radiation oncologists, 117 medical physicists, and 1,635 radiation therapists. Geographically, a significant variation was found in the use of radiotherapy, from 0.9 to 2.1 patients/1,000 population. The annual patient load/FTE radiation oncologist was 247, exceeding the Blue Book guidelines level. Patterns of Care Study stratification can clearly discriminate the maturity of structures according to their academic nature and caseload. Conclusions: The Japanese structure has clearly improved during the past 15 years in terms of equipment and its use, although the shortage of manpower and variations in maturity disclosed by this Patterns of Care Study stratification remain problematic. These constitute the targets for nationwide improvement in quality assurance and quality control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determining moisture content of Traditional Chinese Medicines using a near-infrared LED-based moisture content sensor with spectrum analysis

In Traditional Chinese Medicine (TCM), moisture content (MC) inspection using voltage level or a lock-in amplifier, with a features-based near-infrared light-emitting diode sensor is possible. Abundant absorption response in a wide frequency range and information in both the time-domain and frequency-domain can be obtained, with the square excitation method. However, planeness, heterogeneous particle sizes, and measurement noise negatively affect the time-domain feature during MC inspection. In this work, spectrum analysis (SA) for feature extraction is investigated, to precisely measure the MC of Dutong pills. The principal components for low and high frequencies, are aimed at counteracting the dimensional methods, which are used for supplying the lower dimensional features. The SA experimental results demonstrate that the low frequency components, ranging from the base to the 3rd harmonic components, have a high linear correlation with the MC. The calibration and validation experimental results reveal that the MC can be a monotonic function about the SA amplitudes or first principal component (PC1), with the proposed sensor. This method has the potential to be used for gauging automatic, in situ MCs, particularly for quality control and Process Analytical Technology in TCM. Future research opportunities include improving accuracy and application of the method under field conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiobiology of Hadrons

Radiobiological studies of hadrons beams are essential for optimizing tumour treatments. Whit hadrons when clinical facilities are running radiobiological studies are also done to ensure beam optimization and quality control as well as for the understanding of tumour and normal tissue reactions and late effects. Beam characteristic determinations nowadays are carried out according to well established radiobiological standard parameters and using well established biological reference systems. Some of the most recent studies on the topic are reported here.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combining Image and Non-Image Data for Automatic Detection of Retina Disease in a Telemedicine Network

A telemedicine network with retina cameras and automated quality control, physiological feature location, and lesion/anomaly detection is a low-cost way of achieving broad-based screening for diabetic retinopathy (DR) and other eye diseases. In the process of a routine eye-screening examination, other non-image data is often available which may be useful in automated diagnosis of disease. In this work, we report on the results of combining this non-image data with image data, using the protocol and processing steps of a prototype system for automated disease diagnosis of retina examinations from a telemedicine network. The system includes quality assessments, automated physiology detection, and automated lesion detection to create an archive of known cases. Non-image data such as diabetes onset date and hemoglobin A1c (HgA1c) for each patient examination are included as well, and the system is used to create a content-based image retrieval engine capable of automated diagnosis of disease into 'normal' and 'abnormal' categories. The system achieves a sensitivity and specificity of 91.2% and 71.6% using hold-one-out validation testing.

59 BASIC BIOLOGICAL SCIENCES↗

Use of a Heat Flow Meter to Determine Active PCM Content in an Insulation

Residential and commercial roofs and walls are currently designed and tested using steady-state criteria. The resulting R-values, based on the apparent thermal conductivity, are used by building standards as an important measure of energy performance. Building envelope components, however, are subject to dynamic environmental conditions. This mismatch between the steady-state principles used in design and code requirements and their dynamic operation results in relatively low thermal efficiencies. Although several research centers have developed experimental methods for transient analysis of building envelopes, there are no standardized testing procedures available for screening materials and systems for which performance depends on dynamic response. For example, a full-scale dynamic evaluation of phase change materials (PCMs) is needed to assess their energy saving benefits. A nationally accepted small-scale (one to two foot size specimens) testing procedure is not available for the analysis of dynamic thermal characteristics of conventional thermal mass systems or PCM-enhanced materials. At the same time, data on these characteristics are necessary for whole-building simulations, energy analysis, and energy code work. The transient characteristics of PCM-enhanced products depend on the PCM content and quality. The only readily available method of thermal evaluation uses the differential scanning calorimeter. Unfortunately, this method requires small, relatively uniform test specimens. This requirement is unrealistic in the case of PCM-enhanced building envelope products such as PCM-cellulose, PCM-glass fiber, or PCM-gypsum blends. Small specimens are not representative of PCM-based blends, since these materials are not homogeneous. Jan Kosny and David Yarbrough, Oak Ridge National Laboratory, P.O. Box 2008, MS 6070, Oak Ridge, TN 37831-6070. Elizabeth Kossecka, Polish Academy of Sciences, Institute of Fundamental Technological Research, Pawinskiego 5 B, 02-106, Warsaw, Poland. A procedure for making dynamic heat-flow measurements using existing instrumentation has been developed to analyze the benefits of thermal storage. This small-scale testing method is useful for thermal analysis and as a potential quality control method for producers of PCM-enhanced building materials. The research may provide the basis for consensus standard development. This paper uses as an example a dynamic testing process for PCM-enhanced cellulose insulation.

25 ENERGY STORAGE↗

Defining WAC for interim storage dedicated to tritium decay - 15164

Considering the high mobility of tritium through the package in which it is contained, the new 50-year storage concepts proposed by the CEA currently provide a solution adapted to the management of waste with high tritium concentrations, associated with adapted disposal sites. The 50-year intermediate storage corresponds to 4 tritium radioactive periods i.e. a tritium reduction by a factor 16. The waste acceptance criteria (WAC) for this interim storage concept will take into account the safety of the facility, the reference scheme for the management of tritiated waste in France, and the criteria applicable at Andra disposal centers. This will lead to define a set of waste specifications that describe the generic criteria such as acceptable waste forms, general principles and specific issues, e.g. conditioning, radioactive content, tritium content, waste tracking system, and quality control. This paper details how the work by the CEA has led to a storage facility project that not only takes into account the specificity of tritium, but also the producers' needs and Andra's disposal requirements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Process-based quality management for clinical implementation of adaptive radiotherapy

Purpose: Intensity-modulated adaptive radiotherapy (ART) has been the focus of considerable research and developmental work due to its potential therapeutic benefits. However, in light of its unique quality assurance (QA) challenges, no one has described a robust framework for its clinical implementation. In fact, recent position papers by ASTRO and AAPM have firmly endorsed pretreatment patient-specific IMRT QA, which limits the feasibility of online ART. The authors aim to address these obstacles by applying failure mode and effects analysis (FMEA) to identify high-priority errors and appropriate risk-mitigation strategies for clinical implementation of intensity-modulated ART. Methods: An experienced team of two clinical medical physicists, one clinical engineer, and one radiation oncologist was assembled to perform a standard FMEA for intensity-modulated ART. A set of 216 potential radiotherapy failures composed by the forthcoming AAPM task group 100 (TG-100) was used as the basis. Of the 216 failures, 127 were identified as most relevant to an ART scheme. Using the associated TG-100 FMEA values as a baseline, the team considered how the likeliness of occurrence (O), outcome severity (S), and likeliness of failure being undetected (D) would change for ART. New risk priority numbers (RPN) were calculated. Failures characterized by RPN ≥ 200 were identified as potentially critical. Results: FMEA revealed that ART RPN increased for 38% (n = 48/127) of potential failures, with 75% (n = 36/48) attributed to failures in the segmentation and treatment planning processes. Forty-three of 127 failures were identified as potentially critical. Risk-mitigation strategies include implementing a suite of quality control and decision support software, specialty QA software/hardware tools, and an increase in specially trained personnel. Conclusions: Results of the FMEA-based risk assessment demonstrate that intensity-modulated ART introduces different (but not necessarily more) risks than standard IMRT and may be safely implemented with the proper mitigations.

60 APPLIED LIFE SCIENCES↗