Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Prototype”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Performance of a Front End prototype ASIC for picosecond precision time measurements with LGAD sensors

For the High-Luminosity phase of LHC, the ATLAS experiment is proposing the addition of a High Granularity Timing Detector (HGTD) in the forward region, to mitigate the effects of the increased pile-up. The chosen detection technology is Low Gain Avalanche Detector (LGAD) silicon sensors that can provide an excellent timing resolution below 50 ps. The front-end read-out ASIC must exploit the large signal derivative and small noise provided by the sensor, while keeping low power consumption. This paper presents the results on the first prototype of a front-end ASIC, named ALTIROC0, which contains the analog stages (preamplifier and discriminator) of the read-out chip. The ASIC was characterised both alone and as part of a module with a 2×2 LGAD array of 1.1×1.1 mm 2 pads bump-bonded to it. The various contributions of the electronics to the time resolution were investigated in test-bench measurements with a calibration setup. Both when the ASIC is alone or with a bump-bonded sensor, the jitter of the ASIC is better than 20 ps for an injected charge of 10 fC. The time walk effect, which arises from the different preamplifier response for various injected charges, can be corrected up to 10 ps using a Time Over Threshold measurement. The combined performance of the ASIC and the LGAD sensor, which was measured during a beam test campaign in October 2018 with pions of 120 GeV energy at the CERN SPS, is around 40 ps for all measured modules. All tested modules show good efficiency and time resolution uniformity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the CMS Endcap Timing Layer readout chip prototype with charge injection

We present the characterization of a readout Application-Specific Integrated Circuit (ASIC) for the CMS Endcap Timing Layer (ETL) of the High-Luminosity LHC upgrade with charge injection. The ASIC, named ETROC and developed in a 65 nm CMOS technology, reads out a 16× 16 pixel matrix of the Low-Gain Avalanche Detector (LGAD). The jitter contribution from ETROC is required to be below 40 ps to achieve the 50 ps overall time resolution per hit. The analog readout circuits in ETROC consist of the preamplifier and the discriminator. The preamplifier handles the LGAD charge signal with the most probable value of around 15 fC. The discriminator generates the digital pulse, which provides the Time-Of-Arrival (TOA, leading edge) and Time-Over-Threshold (TOT, pulse width) information. The prototype of ETROC (ETROC0) that implements a single channel of analog readout circuits has been evaluated with charge injection. The jitter of the analog readout circuits, measured from the discriminator's leading edge, is better than 16 ps for a charge larger than 15 fC with the sensor capacitance. The time walk resulting from different pulse heights can be corrected using the TOT measurement. The time resolution distribution has a standard deviation of 29 ps after the time-walk correction from the charge injection. At room temperature, the preamplifier's power consumption is measured to be 0.74 mW and 1.53 mW per pixel in the low- and high-power mode, respectively. Finally, the measured power consumption of the discriminator is 0.84 mW per pixel. With the ASIC alone or the LGAD sensor, The characterization performances fulfill the ETL's challenging requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of Michigan sMDT prototype chambers for the HL-LHC ATLAS muon detector upgrade

A new small-diameter Monitored Drift Tube (sMDT) chamber has been developed for the muon spectrometer of the ATLAS experiment to handle the higher collision rates expected at the CERN High Luminosity Large Hadron Collider (HL-LHC). This paper presents measurements of the tracking resolution and hit efficiency of two prototype sMDT chambers constructed at the University of Michigan. Using cosmic-ray muons the sMDT tracking resolution of 103.7 ± 8.1 μm was measured for one chamber and 101.8 ± 7.8 μm for the other, compared with a design resolution of 106 μm. A further tracking resolution improvement to 83.4 ± 7.8 μm was obtained by using new high-gain readout electronics which will be added for HL-LHC. An average tracking efficiency of (98.5 ± 0.2)% was found for both chambers. The methodology used to determine the detector tracking resolution and efficiency, including reconstruction of sMDT data and a Geant4 simulation of the test chamber, is presented in detail.

43 PARTICLE ACCELERATORS↗

Readout electronics for the CMS Phase II Endcap Calorimeter: system overview and prototyping experience

Abstract The frontend readout system for the silicon section of the CMS Phase II Endcap Calorimeter faces unique challenges due to the high channel count and associated bandwidth, limited physical space, as well as radiation tolerance requirements. I will give an overview of the frontend electronics design and will discuss the recent experience obtained from the first test system that integrates the HGCROC2 readout ASIC, lpGBT, and VTRX+ in a realistic manner, linking together prototypes of the hexaboard, engine, and wagon boards.

Instruments & Instrumentation↗

Timing Performance of the CMS High Granularity Calorimeter Prototype

This paper describes the experience with the calibration,reconstruction and evaluation of the timing capabilities of the CMSHGCAL prototype in the beam tests in 2018. The calibrationprocedure includes multiple steps and corrections ranging from tensof nanoseconds to a few hundred picoseconds. The timing performanceis studied using signals from positron beam particles with energiesbetween 20 GeV and 300 GeV. The performance is studied as afunction of particle energy against an external timing reference aswell as standalone by comparing the two different halves of theprototype. The timing resolution is found to be 60 ps forsingle-channel measurements and better than 20 ps for full showersat the highest energies, setting excellent perspectives for theHGCAL calorimeter performance at the HL-LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First operation of a multi-channel Q-Pix prototype: measuring transverse electron diffusion in a gas time projection chamber

We report measurements of the transverse diffusion of electrons in P-10 gas (90% Ar, 10% CH 4 ) in a laboratory-scale time projection chamber (TPC) utilizing a novel pixelated signal capture and digitization technique known as Q-Pix. The Q-Pix method incorporates a precision switched integrating transimpedance amplifier whose output is compared to a threshold voltage. Upon reaching the threshold, a comparator sends a 'reset' signal, initiating a discharge of the integrating capacitor. The time difference between successive resets is inversely proportional to the average current at the pixel in that time interval, and the number of resets is directly proportional to the total collected charge. We developed a 16-channel Q-Pix prototype fabricated from commercial off-the-shelf components and coupled them to 16 concentric annular anode electrodes to measure the spatial extent of the electron swarm that reaches the anode after drifting through the uniform field of the TPC. The swarm is produced at a gold photocathode using pulsed UV light. The measured transverse diffusion agrees with simulations in PyBoltz across a range of operating pressures (200–1500 Torr). These results demonstrate that a Q-Pix readout can successfully reconstruct the ionization topology in a TPC.

47 OTHER INSTRUMENTATION↗

ETROC1: the first full chain precision timing prototype ASIC for CMS MTD endcap timing layer upgrade

We present the design and characterization of the first fullchain precision timing prototype ASIC, named ETL Readout Chipversion 1 (ETROC1) for the CMS MTD endcap timing layer (ETL)upgrade. The ETL utilizes Low Gain Avalanche Diode (LGAD) sensors todetect charged particles, with the goal to achieve a time resolutionof 40–50 ps per hit, and 30–40 ps per track with hits from twodetector layers. The ETROC1 is composed of a 5 × 5 pixelarray and peripheral circuits. The pixel array includes a4 × 4 active pixel array with an H-tree shaped networkdelivering clock and charge injection signals. Each active pixel iscomposed of various components, including a bump pad, a chargeinjection circuit, a pre-amplifier, a discriminator, adigital-to-analog converter, and a time-to-digital converter. Thesecomponents play essential roles as the front-end link in processingLGAD signals and measuring timing-related information. Theperipheral circuits provide clock signals and readoutfunctionalities. The size of the ETROC1 chip is7 mm× 9 mm. ETROC1 has been fabricated in a 65 nmCMOS process, and extensively tested under stimuli of chargeinjection, infrared laser, and proton beam. The time resolution ofbump-bonded ETROC1 + LGAD chipsets reaches 42–46 ps per hit in thebeam test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam test performance studies of CMS Phase-2 Outer Tracker module prototypes

A new tracking detector will be installed as part of thePhase-2 upgrade of the CMS detector for the high-luminosity LHC era.This tracking detector includes the Inner Tracker, equipped withsilicon pixel sensor modules, and the Outer Tracker, consisting ofmodules with two parallel stacked silicon sensors. The Outer Trackerfront-end ASICs will be able to correlate hits from chargedparticles in these two sensors to perform on-module discriminationof transverse momenta (p$_{T}$). The p$_{T}$information is generated at a frequency of 40 MHz and will be usedin the Level-1 trigger decision of CMS. Prototypes of theso-called 2S modules were tested at the Test Beam Facility at DESYHamburg between 2019 and 2020. These modules use the finalfront-end ASIC, the CMS Binary Chip (CBC), and for the firsttime the Concentrator Integrated Circuit (CIC), optical readoutand on-module power conversion. In total, seven modules were tested,one of which was assembled with sensors irradiated with protons. Animportant aspect was to show that it is possible to read out modulessynchronously. A cluster hit efficiency of about 99.75 % wasachieved for all modules. The CBC p$_{T}$ discriminationmechanism has been verified to work together with the CIC andoptical readout. The measured module performance meets therequirements for operation in the upgraded CMS tracking detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CMS Phase-2 Fast Beam Condition Monitor prototype test with beam

The Fast Beam Condition Monitor (FBCM) is a standalone luminometer for the High Luminosity LHC (HL-LHC) program of the CMS Experiment at CERN. The detector is under development and features a new, radiation-hard, front-end application-specific integrated circuit (ASIC) designed for beam monitoring applications. The achieved timing resolution of a few nanoseconds enables the measurement of both the luminosity and the beam-induced background. The ASIC, called FBCM23, features six channels with adjustable shaping times, enabling in-field fine-tuning. Each ASIC channel outputs a single binary asynchronous signal encoding time-of-arrival and time-over-threshold information. The FBCM is based on silicon-pad sensors, with two sensor designs presently being considered. This paper presents the results of tests of the FBCM detector prototype using both types of silicon sensors with hadron, muon, and electron beams. Irradiated FBCM23 ASICs and silicon-pad sensors were also tested to simulate the expected conditions near the end of the detector's lifetime in the HL-LHC radiation environment. Based on test results, direct bonding between the sensor and ASIC was chosen, and an optimal bias voltage and ASIC threshold for FBCM operation were proposed. The current design of the front-end test board was validated following the beam test and is now being used for the first front-end module, which is expected to be produced in summer 2025. These results represent a major step forward in validating the FBCM concept, first version of the firmware and establishing a reliable design path for the final detector.

Beam-line instrumentation (beam position and profi↗

Sensor Development and Readout Prototyping for the STAR Pixel Detector

The STAR experiment at the Relativistic Heavy Ion Collider (RHIC) is designing a new vertex detector. The purpose of this upgrade detector is to provide high resolution pointing to allow for the direct topological reconstruction of heavy flavor decays such as the D{sup 0} by finding vertices displaced from the collision vertex by greater than 60 microns. We are using Monolithic Active Pixel Sensor (MAPS) as the sensor technology and have a coupled sensor development and readout system plan that leads to a final detector with a <200 {micro}s integration time, 400 M pixels and a coverage of -1 < {eta} < 1. We present our coupled sensor and readout development plan and the status of the prototyping work that has been accomplished.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prototype ATLAS IBL modules using the FE-I4A front-end readout chip

The ATLAS Collaboration will upgrade its semiconductor pixel tracking detector with a new Insertable B-layer (IBL) between the existing pixel detector and the vacuum pipe of the Large Hadron Collider. The extreme operating conditions at this location have necessitated the development of new radiation hard pixel sensor technologies and a new front-end readout chip, called the FE-I4. Planar pixel sensors and 3D pixel sensors have been investigated to equip this new pixel layer, and prototype modules using the FE-I4A have been fabricated and characterized using 120 GeV pions at the CERN SPS and 4 GeV positrons at DESY, before and after module irradiation. Beam test results are presented, including charge collection efficiency, tracking efficiency and charge sharing.

3D sensors↗

A MRPC prototype for SOLID-TOF in Jlab

A prototype of Multi-gap Resistive Plate Chamber (MRPC) for the future SoLID time of flight system at JLab has been developed. The counter, trapezoidal in shape, is assembled with the newly developed low-resistive Chinese glass. It has 10 × 0.25 mm gas gaps and 11 readout strips of different lengths. The strip width is 2.5 cm with a strip-to-strip interval of 3 mm. Preliminary tests performed with cosmic-rays showed an efficiency higher than 95% and a time resolution around 50 ps. Results under diffuse/uniform irradiation performed at JLab with scattered high energy electrons showed a time resolution of 70–80 ps and over-95% efficiency up to an incoming flux of 15 kHz/cm{sup 2}. These performances meet the requirements of the new time of flight system SoLID-TOF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FIRST SPECTROSCOPIC IMAGING OBSERVATIONS OF THE SUN AT LOW RADIO FREQUENCIES WITH THE MURCHISON WIDEFIELD ARRAY PROTOTYPE

We present the first spectroscopic images of solar radio transients from the prototype for the Murchison Widefield Array, observed on 2010 March 27. Our observations span the instantaneous frequency band 170.9- 201.6 MHz. Though our observing period is characterized as a period of 'low' to 'medium' activity, one broadband emission feature and numerous short-lived, narrowband, non-thermal emission features are evident. Our data represent a significant advance in low radio frequency solar imaging, enabling us to follow the spatial, spectral, and temporal evolution of events simultaneously and in unprecedented detail. The rich variety of features seen here reaffirms the coronal diagnostic capability of low radio frequency emission and provides an early glimpse of the nature of radio observations that will become available as the next generation of low-frequency radio interferometers come online over the next few years.

79 ASTRONOMY AND ASTROPHYSICS↗

Prototype reactor-antineutrino detector based on 6 Li-doped pulse-shape-discriminating plastic scintillator

An aboveground 60-kg reactor-antineutrino detector prototype, comprising a two-dimensional array of 36 6 ⁢Li-doped pulse-shape-sensitive plastic scintillator bars, is described. Each bar is 50 cm long with a square cross section of 5.5 cm. Doped with 6 ⁢Li at 0.1% by mass, the detector is capable of identifying correlated energy depositions for the detection of reactor antineutrinos via the inverse-𝛽-decay (IDB) reaction. Each bar is wrapped with a specular reflector that directs photons toward photomultiplier tubes mounted at both ends of the bar. Here, this paper highlights the construction, key features, and main performance characteristics of the system. The system, which relies on multiple observables such as pulse-shape discrimination, energy, position, and timing, is capable of detecting IBD-like neutron-correlated backgrounds, long-lived decay chains, and cosmogenic isotopes.

Physics↗

First Search for Axion Dark Matter with a MADMAX Prototype

This Letter presents the first search for dark matter axions with mass in the ranges 76.56 to 76.82 μ⁢eV and 79.31 to 79.53 μ⁢eV using a prototype setup for the MAgnetized Disk and Mirror Axion eXperiment (MADMAX). The experimental setup employs a dielectric haloscope consisting of three sapphire disks and a mirror to resonantly enhance the axion-induced microwave signal within the magnetic dipole field provided by the 1.6 T Morpurgo magnet at CERN. Over 14.5 days of data collection, no axion signal was detected. A 95% CL upper limit on the axion-photon coupling strength down to |𝑔 𝑎⁢𝛾 |∼2×10 −11 GeV −1 is set in the targeted mass ranges, surpassing previous constraints, assuming a local axion dark matter density 𝜌 𝑎 of 0.3 GeV/cm 3 . This study marks the first axion dark matter search using a dielectric haloscope.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prototypes of Nonrelativistic Spin Splitting and Polarization in Symmetry Broken Antiferromagnets

Antiferromagnets that break both space-time reversal and translation-spin-rotation symmetries were recently predicted [L.-D. Yuan, Z. Wang, J.-W. Luo, E. I. Rashba, and A. Zunger, Phys. Rev. B 102, 014422 (2020)] to possess splitting between the otherwise spin-degenerate energy bands even without the relativistic spin-orbit coupling (SOC). Here, we point out that such nonrelativistic spin splitting (NRSS)—in particular, “spin splitting type 4” (SST-4) symmetry-broken antiferromagnets—can be divided into subgroups having distinct patterns of spin splitting and spin textures, depending on additional auxiliary symmetries of spin interconversion and polarity. These SST-4 subgroups include the 𝛼-type (no spin-interconverting symmetry) having spin splitting at the Brillouin zone center, as well as the 𝛽 subgroup in which a rotation symmetry is applied and determines the alternating spin texture and the 𝛾 subgroup having exclusively reflection spin-interconverting symmetry. Unlike ferrimagnets, the 𝛼-type compounds are shown to have tiny net magnetization at finite temperature and thus avoid the adverse effect of the stray field. The 𝛼 and 𝛽 subgroups can be either polar or nonpolar, whereas the 𝛾 subgroup is polar only, providing a basis for possible switching by external fields. The combination of NRSS-enabling and auxiliary symmetries is used here as a filter for identifying previously synthesized compounds as specific prototypes. Their characteristic splitting and spin polarization are calculated by density functional theory to the benefit of potential future experimental testing. Interesting results are as follows: (i) SOC-independent NRSS can exceed the magnitude of the SOC-induced Rashba and Dresselhaus spin splitting in semiconductors. (ii) Examples of predicted 𝛼-type insulating compounds include BiCrO 3 (nonpolar) and Mn 2 ⁢ScSbO 6 (polar), the latter having spin splitting of 158 meV and 160 meV in the valence and conduction bands, respectively. (iii) The 𝛽-type (Cu 2 ⁢Y 2 ⁢O 5 and FeF 2 ) and 𝛾-type compounds (Mn 4 ⁢Nb 2 ⁢O 9 and FeScO 3 ) are distinguished both by their auxiliary symmetries and polarity. The spin textures of 𝛾-type compounds are mirror reflected with spin degeneracy of the wave vectors on that mirror. These observations will likely broaden the experimental playing field of NRSS physics significantly.

antiferromagnets↗

Ba 0.4 Rb 0.6 Mn 2 As 2 : A prototype half-metallic ferromagnet

Half-metallic ferromagnetism (FM) in single-crystal Ba 0.39(1) Rb 0.61(1) Mn 2 As 2 below its Curie temperature T C = 103(2) K is reported. The magnetization M versus applied magnetic field H isotherm data at 1.8 K show complete polarization of the itinerant doped-hole magnetic moments that are introduced by substituting Rb for Ba. Here, the material exhibits extremely soft FM, with unobservably small remanent magnetization and coercive field. Surprisingly, and contrary to typical itinerant FMs, the M(H) data follow the Arrott-plot paradigm that is based on a mean-field theory of local-moment FMs. The in-plane electrical resistivity data are fitted well by an activated-T 2 expression for T ≤ T C , whereas the data sharply deviate from this model for T > T C . Hence the activated-T 2 resistivity model is an excellent diagnostic for determining the onset of half-metallic FM in this compound, which in turn demonstrates the presence of a strong correlation between the electronic transport and magnetic properties of the material. Together with previous data on 40% hole-doped Ba 0.6 K 0.4 Mn 2 As 2 , these measurements establish 61%-doped Ba 0.39 Rb 0.61 Mn 2 As 2 as a prototype for a class of half-metallic ferromagnets in which all the itinerant carriers in the material are ferromagnetic.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

kg-mass prototype demonstrator for dual gravitational wave detector: Optomechanical excitation and cooling

The next generation of gravitational wave (gw) detectors is expected to fully enter into the quantum regime of force and displacement detection. With this aim, it is important to scale up the experiments on opto-mechanical effects from the microscopic regime to large mass systems and test the schemes that should be applied to reach the quantum regime of detection. In this work we present the experimental characterization of a prototype of massive gw detector, composed of two oscillators with a mass of the order of the kg, whose distance is read by a high finesse optical cavity. The mechanical response function is measured by exciting the oscillators through modulated radiation pressure. We demonstrate two effects crucial for the next generation of massive, cryogenic gw detectors (DUAL detectors): (a) the reduction of the contribution of 'local' susceptibility thanks to an average over a large interrogation area. Such effect is measured on the photo-thermal response thanks to the first implementation of a folded-Fabry-Perot cavity; (b) the 'backaction reduction' due to negative interference between acoustic modes. Moreover, we obtain the active cooling of an oscillation mode through radiation pressure, on the described mechanical device which is several orders of magnitude heavier than previously demonstrated radiation-pressure cooled systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗