Completed and Interpreted Baseline Seismic Survey Report (SECARB Phase III Work Product 4.2.2.b)

Advanced Resources presents the results of the seismic survey performed at the SECARB Citronelle project in Alabama. The CO 2 monitoring effort for the Anthropogenic Test includes two wellbore seismic methods, specifically time-lapse crosswell seismic and vertical seismic profiles (VSP). Due to the unique challenges presented by this test (injection depth of 9,500+ ft. into thin, stacked reservoir sands and limited injection volumes) surface seismic was eliminated as a Monitoring, Verification, and Accounting (MVA) tool. However, the newly drilled project wells provided ample casing diameters (prior to running tubing) to accommodate wellbore seismic receivers (wireline and tubing deployed) and a crosswell source. Baseline surveys were conducted in 2012 prior to the onset of CO 2 injection operations. Reports document the results from the baseline vertical seismic profile (VSP) and crosswell seismic surveys performed by SR2020 and Schlumberger Carbon Services, respectively.

54 ENVIRONMENTAL SCIENCES↗

PSU ESI Review

A guide to developing an Energy Service Interface (ESI) was created as part of the Grid Modernization Laboratory Consortium 2.5.2 ESI project. The approach applies device-agnostic and service-oriented ESI principles and leverages documents such as the Interoperability Maturity Model and Common Grid Service Definitions to provide a methodology to review, develop, and update standards and profiles to engage distributed energy resources (DER) to provide grid services. This document evaluates the ESI developed by Portland State University’s Power Engineering Group under the Electric Grid of Things project funded by the U.S. Department of Energy. The evaluation explores the compliance of this specific implementation with the GMLC ESI principles to provide an example of an ESI profile and gap analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wire Scanner Beam Profile Measurements for the LANSCE Facility

The Los Alamos Neutron Science Center (LANSCE) is replacing beam profile measurement systems, commonly known as Wire Scanners (WS). Using the principal of secondary electron emission, the WS measurement system moves a wire or fiber across an impinging particle beam, sampling a projected transverse-beam distribution. Because existing WS actuators and electronic components are either no longer manufactured or home-built with antiquated parts, a new WS beam profile measurement is being designed, fabricated, and tested. The goals for these new WS's include using off-the-shelf components while eliminating antiquated components, providing quick operation while allowing for easy maintainability, and tolerating external radioactivation. The WS measurement system consists of beam line actuators, a cable plant, an electronics processor chassis, and software located both in the electronics chassis (National Instruments LabVIEW) and in the Central Control Room (EPICS-based client software). This WS measurement system will measure Hand H{sup +} LANSCE-facility beams and will also measure less common beams. This paper describes these WS measurement systems.

43 PARTICLE ACCELERATORS↗

1 H NMR-based metabolomics of antimalarial plant species traditionally used by Vha-Venda people in Limpopo Province, South Africa and isolation of antiplasmodial compounds

The Vha-Venda people living in rural areas of Limpopo Province of South Africa regularly use traditional plant-based medicines to treat malaria. In our earlier publication, twenty indigenous plant species used to treat malaria or its symptoms by Vha-Venda people were evaluated for antiplasmodial activity. The main objective of the current paper was to assess the robustness of NMR-based metabolomics in discriminating classes of secondary compounds that are responsible for the observed antimalarial activity and the isolation of antiplasmodial compounds. Twenty dichloromethane extracts were reconstituted in CDCl 3 , subjected to 1 H NMR-based metabolomic analysis on a Varian 600 MHz spectrometer and the acquired 1 H NMR spectra were then evaluated collectively using multivariate data analysis (MDA). Principal Component Analysis (PCA) and Orthogonal Projections to Latent Structures–Discriminant Analysis (OPLS-DA) were used to ‘globally’ discern antiplasmodial profiles. A contribution plot was then generated from the OPLS-DA scoring plot in an attempt to determine the classes of compounds that are responsible for the observed grouping. Further phytochemical analyses were conducted on the lipophilic extracts of Tabernaemontana elegans and Vangueria infausta subsp. infausta. These best candidates were fractionated, purified and their isolated compounds identified based on conventional chromatographic and spectroscopic techniques. The PCA did not separate the acquired profiles according to the detected antiplasmodial bioactivity. Application of a supervised OPLS-DA on the 1 H NMR profiles resulted in a discrimination pattern that could be correlated to the observed antimalarial bioactivity. A contribution plot generated from the OPLS-DA scoring plot illustrated the classes of compounds responsible for the observed grouping. Prominent peaks were observed in the aromatic, sugar-based/N-containing and aliphatic spectral regions of the contribution plot. Two known indole alkaloids were isolated from T. elegans, and identified as tabernaemontanine (IC 50 = 12.0±0.8 µM) and dregamine (IC 50 = 62.0±2.4 µM). Friedelin (IC 50 = 7.20±0.5 µM) and morindolide (IC 50 = 107.1±0.6 µM) were isolated from V. infausta subsp. infausta. This is the first report of the rare iridoid lactone, morindolide's antimalarial activity. While these two compounds have been previously identified, this is the first account of their occurrence in the genus Vangueria. The study illustrated the potential of NMR-based metabolomics in discriminating classes of compounds that may be attributed to antiplasmodial activity. Finally and additionally, the study demonstrated the potential of discovering novel antiplasmodial scaffolds from medicinal plants and the rationale for the bioprospecting antimalarial plant species used by Vha-Venda people.

59 BASIC BIOLOGICAL SCIENCES↗

SHEAR-SELECTED CLUSTERS FROM THE DEEP LENS SURVEY. III. MASSES FROM WEAK LENSING

We present weak lensing mass estimates of seven shear-selected galaxy cluster candidates from the deep lens survey. The clusters were previously identified as mass peaks in convergence maps of 8.6 deg{sup 2} of R-band imaging, and followed up with X-ray and spectroscopic confirmation, spanning a redshift range 0.19-0.68. Most clusters contained multiple X-ray peaks, yielding 17 total mass concentrations. In this paper, we constrain the masses of these X-ray sources with weak lensing, using photometric redshifts from the full set of BVRz' imaging to properly weight background galaxies according to their lensing distance ratios. We fit both NFW and singular isothermal sphere profiles, and find that the results are insensitive to the assumed profile. We also show that the results do not depend significantly on the assumed prior on the position of the mass peak, but that this may become an issue in future larger samples. The inferred velocity dispersions for the extended X-ray sources range from 250 to 800 km s{sup -1}, with the exception of one source for which no lensing signal was found. This work further establishes shear selection as a viable technique for finding clusters, but also highlights some unresolved issues such as determination of the mass profile center without biasing the mass estimate, and fully accounting for line-of-sight projections. A follow-up paper will examine the mass-X-ray scaling relations of these clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the normalized U 238 ( n , f ) / U 235 ( n , f ) cross section ratio from threshold to 30 MeV with the NIFFTE fission Time Projection Chamber

We present that the normalized 238 U(n,f)/ 235 U(n,f) cross section ratio has been measured using the NIFFTE fission Time Projection Chamber (fissionTPC) from the reaction threshold to 30 MeV . The fissionTPC is a two-volume MICROMEGAS time projection chamber that allows for full three-dimensional reconstruction of fission-fragment ionization profiles from neutron-induced fission. The measurement was performed at the Los Alamos Neutron Science Center, where the neutron energy is determined from neutron time of-flight. The 238 U(n,f)/ 235 U(n,f) ratio reported here is the first cross section measurement made with the fissionTPC, and will provide new experimental data for evaluation of the 238 U(n,f) cross section, an important standard used in neutron-flux measurements. Use of a development target in this work prevented the determination of an absolute normalization, to be addressed in future measurements. Instead, the measured cross section ratio has been normalized to ENDF/B-VIII.β5 at 14.5 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Rutherford-in-Copper-Channel Conductor for the MARCO Solenoidal Detector Magnet

MARCO will be a superconducting solenoid for a new particle physics detector of the upcoming Electron Ion Collider (EIC) at Brookhaven National Laboratory (NY, USA). The design field at the interaction point is 2.0 T with a nominal current of about 4 kA at 4.5 K. For this magnet, an aluminumstabilized conductor was considered at the very preliminary design phase. After that, since the lack of manufacturers able to deal with aluminum extrusion, copper has been chosen as stabilizer. Thanks to a dedicated design effort, the copper stabilizer and accompanying material choices provided acceptable hadronic interaction length. The conductor is based on a NbTi Rutherford cable that is soldered in a U-shaped copper profile. Here, this paper goes through the definition of the conductor crosssection according to the project requirements and the supplier capabilities. Its characteristics will be detailed and discussed, in particular the RRR and the yield strength of the copper channel needed for protection and mechanics respectively. Finally, a proposal on how to make the joint between two conductors is presented.

Stacchi, Francesco [Commissariat a l'Energie Atomi↗

SU-G-JeP1-13: Innovative Tracking Detector for Dose Monitoring in Hadron Therapy: Realization and Monte Carlo Simulations

Purpose: Development of strategies to monitor range uncertainties is necessary to improve treatment planning in Charged Particle Therapy (CPT) and fully exploit the advantages of ion beams. Our group developed (within the framework of the INSIDE project funded by the Italian research ministry) and is currently building a compact detector Dose Profiler (DP) able to backtrack charged secondary particles produced in the patient during the irradiation. Furthermore we are studying monitoring strategy exploiting charged secondary emission profiles to control the range of the ion beam. Methods: This contribution reports on the DP detector design and construction status. The detector consists of a charged secondary tracker composed of scintillating fiber layers and a LYSO calorimeter for particles energy measurement.The detector layout has been optimized using the FLUKA Monte Carlo (MC) simulation software. The simulation of a 220 MeV Carbon beam impinging on a PMMA target has been performed to study the detector response, exploiting previous secondary radiation measurements performed by our group. The emission profile of charged secondary particles was reconstructed backtracking the particles to their generation point to benchmark the DP performances. Results: The DP construction status, including the technological details will be presented. The feasibility of range monitoring with DP will be demonstrated by means of MC studies. The correlation of the charged secondary particles emission shape with the position of the Bragg peak (BP) will be shown, as well as the spatial resolution achievable on the BP position estimation (less than 3 mm) in the clinical like conditions. Conclusion: The simulation studies supported the feasibility of an accurate range monitoring technique exploiting the use of charged secondary fragments emitted during the particle therapy treatment. The DP experimental tests are foreseen in 2016, at CNAO particle therapy center in Pavia.

60 APPLIED LIFE SCIENCES↗

Y-12 Site Sustainability Plan

Y-12 is committed to achieving the sustainable energy and transportation goals established in Executive Orders 13423 and 13514. Although complete accomplishment of the present goals would exceed existing funding levels, Y-12 will continue to execute projects as funding becomes available or as they can be accomplished incrementally within current funding profiles. All efforts will be made to integrate energy and sustainability initiatives with ongoing site mission objectives.

99 GENERAL AND MISCELLANEOUS↗

Multi-shock design tools in double shell models

The essence of the project was to implement a program in python that demonstrated certain models put forth by fusion physicists. Across the time spent at Los Alamos National Laboratory, much was spent programming. Though fundamentally programmatical in nature, the task contained considerable difficulty hid within mathematically deriving and manipulating the models while maintaining data discretization. The result of solving these complications gave invaluable experience in applied mathematics. The final product, a piece of lengthy code, ended up having the full range of desired capabilities, with plans for more. Given the laser power history from a pulse shot on NIF, Omega, or any other Inertial Confinement Fusion facility, the code maps the terrain of radiation temperature inside the hohlraum throughout the period of the shot. Additionally, shock wave convergence prediction was implemented as additional capability. As the name of the project suggests, this tool acts as a compass of direction for researchers designing laser power profiles. Further development of this tool will undoubtedly assist in the research conducted on single and double-shell indirect ICF, consequently expanding the capabilities of operating stewardship over the national nuclear stockpile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ARPA-E PERFORM datasets

Time-coincident load, wind, and solar data including actual and probabilistic forecast datasets at 5-min resolution for ERCOT, MISO, NYISO, and SPP. Wind and solar profiles are supplied for existing sites as well as planned sites based on interconnection queue projects as of 2021. For ERCOT actuals are provided for 2017 and 2018 and forecasts for 2018, and for the remaining ISOs actuals are provided for 2018 and 2019 and forecasts for 2019. There datasets were produced by NREL as part of the ARPA-E PERFORM project, an ARPA-E funded program that aim to use time-coincident power and load seeks to develop innovative management systems that represent the relative delivery risk of each asset and balance the collective risk of all assets across the grid. For more information on the datasets and methods used to generate them see https://github.com/PERFORM-Forecasts/documentation.

5-min data↗

The Quantum Nature and Mass of the Neutrino. FY20 Annual Laboratory Continuation Progress Report

Over the last 100 years we have learned a much about the neutrino, but there remain interesting questions about this weakly interacting particle. In particular, at LLNL we are developing experiments to measure the mass and the quantum nature of the neutrino. The 2015 long range plan recommended tonne-scale neutrinoless double beta decay experiments as the top new project priority and this experiment will target the quantum nature of the neutrino. The LLNL team is motivated and focused on developing the best technology for this experiment which is a liquid xenon time project chamber called nEXO. On a longer time scale, LLNL is also developing technology to measure the neutrino mass with tritium decay experiments. Work on nEXO at LLNL started in 2015 with an LDRD and program development funds to develop the nEXO concept, publish sensitivity predictions, explore alternatives and risks, and to build a credible project team and this effort is on going. In addition, we received research funding from DOE-SC NP and LLNL manages pre-conceptual R&D for the nEXO collaboration a portion of which is executed at LLNL. The Project 8 effort is solely funded by LLNL LDRD, and ends this year. A second LDRD effort is focused on repurposing cyclotron radiation emission spectroscopy for eV-scale X-ray detection. This second effort, while separated from Project 8, still has scientific and technical commonalities with Project 8. The funding for this X-ray detection effort will continue for one more year. LLNL has a long history of building large projects, science projects and time projection chambers, but nEXO is in fact the first project of this scale that LLNL is prepared to lead for DOE-SC NP.We have the tools, skills, people and motivation to make nEXO a reality. The current program development dollars are used to prepare the nEXO concept for down select and CD1. These internal LLNL dollars pay for a number of things including project staff to organize the nEXO collaboration for the various reviews that lie ahead, to develop the draft plans and structure to manage the project as well as setting up an external advisory committee. The current LDRD is exploring alternatives that effect the risk profile as well as possible performance improvements. The DOE-SC NP base funding is targeted at simulation and analysis of the nEXO concept in preparation for the down select and refinement of the understanding of the detector as well as scientific effort on the large xenon test stand (LXTS) that will burn down one of the largest risks to the nEXO project. Lastly, LLNL is leading the pre-conceptual R&D effort and managing the funds for the nEXO collaboration. The results of this effort are reported elsewhere, but the scope of this executed at LLNL will be reported here and is primarily the engineering and construction of the LXTS experiment. The primary technical contribution of LLNL to the Project 8 concept is the formation and study of atomic tritium. Atomic tritium is necessary for Project 8 to reach the ultimate sensitivity. LLNL has considerable experience with tritium and is well suited for this crucial work. Although the focus of this work is strictly fundamental science, there has already been one significant spinoff to develop a new means to measure radio xenon in the air

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

LANSCE harp upgrade: analysis, design, fabrication and installation

The primary goal of this newly installed beam profile measurement is to provide the facility operators and physicists with a reliable horizontal and vertical projected beam distribution and location with respect to the proton beam target and beam aperture. During a 3000-hour annual run cycle, 5 {mu}C of charge is delivered every 50 milliseconds through this harp to the downstream TRMS Mark III target. The resulting radioactive annual dose near this harp is at least 6 MGy. Because of this harsh environment, the new harp design has been further optimized for robustness. For example, compared to an earlier design, this harp has half of the sensing wires and utilizes only a single bias plane. The sensing fibers are 0.079-mm diameter SiC fibers. To hold these fibers to a rigid ceramic structure, a collet fiber-clamping device accomplishes the three goals of maintaining a mechanical fiber clamp, holding the sense fibers under a slight tensile force, and providing a sense-fiber electrical connection. This paper describes the harp analysis and design, and provides fabrication, assembly, and some installation information, and discusses wiring alterations.

43 PARTICLE ACCELERATORS↗

SU-E-I-20: Dead Time Count Loss Compensation in SPECT/CT: Projection Versus Global Correction

Purpose: To compare projection-based versus global correction that compensate for deadtime count loss in SPECT/CT images. Methods: SPECT/CT images of an IEC phantom (2.3GBq 99mTc) with ∼10% deadtime loss containing the 37mm (uptake 3), 28 and 22mm (uptake 6) spheres were acquired using a 2 detector SPECT/CT system with 64 projections/detector and 15 s/projection. The deadtime, Ti and the true count rate, Ni at each projection, i was calculated using the monitor-source method. Deadtime corrected SPECT were reconstructed twice: (1) with projections that were individually-corrected for deadtime-losses; and (2) with original projections with losses and then correcting the reconstructed SPECT images using a scaling factor equal to the inverse of the average fractional loss for 5 projections/detector. For both cases, the SPECT images were reconstructed using OSEM with attenuation and scatter corrections. The two SPECT datasets were assessed by comparing line profiles in xyplane and z-axis, evaluating the count recoveries, and comparing ROI statistics. Higher deadtime losses (up to 50%) were also simulated to the individually corrected projections by multiplying each projection i by exp(-a*Ni*Ti), where a is a scalar. Additionally, deadtime corrections in phantoms with different geometries and deadtime losses were also explored. The same two correction methods were carried for all these data sets. Results: Averaging the deadtime losses in 5 projections/detector suffices to recover >99% of the loss counts in most clinical cases. The line profiles (xyplane and z-axis) and the statistics in the ROIs drawn in the SPECT images corrected using both methods showed agreement within the statistical noise. The count-loss recoveries in the two methods also agree within >99%. Conclusion: The projection-based and the global correction yield visually indistinguishable SPECT images. The global correction based on sparse sampling of projections losses allows for accurate SPECT deadtime loss correction while keeping the study duration reasonable.

60 APPLIED LIFE SCIENCES↗

SU-E-I-21: Deformation Mapping and Shape Prediction with 3D Tumor Volume Morphing

Purpose: To compare projection-based versus global correction that compensate for deadtime count loss in SPECT/CT images. Methods: SPECT/CT images of an IEC phantom (2.3GBq 99mTc) with ∼10% deadtime loss containing the 37mm (uptake 3), 28 and 22mm (uptake 6) spheres were acquired using a 2 detector SPECT/CT system with 64 projections/detector and 15 s/projection. The deadtime, Ti and the true count rate, Ni at each projection, i was calculated using the monitor-source method. Deadtime corrected SPECT were reconstructed twice: (1) with projections that were individually-corrected for deadtime-losses; and (2) with original projections with losses and then correcting the reconstructed SPECT images using a scaling factor equal to the inverse of the average fractional loss for 5 projections/detector. For both cases, the SPECT images were reconstructed using OSEM with attenuation and scatter corrections. The two SPECT datasets were assessed by comparing line profiles in xyplane and z-axis, evaluating the count recoveries, and comparing ROI statistics. Higher deadtime losses (up to 50%) were also simulated to the individually corrected projections by multiplying each projection i by exp(-a*Ni*Ti), where a is a scalar. Additionally, deadtime corrections in phantoms with different geometries and deadtime losses were also explored. The same two correction methods were carried for all these data sets. Results: Averaging the deadtime losses in 5 projections/detector suffices to recover >99% of the loss counts in most clinical cases. The line profiles (xyplane and z-axis) and the statistics in the ROIs drawn in the SPECT images corrected using both methods showed agreement within the statistical noise. The count-loss recoveries in the two methods also agree within >99%. Conclusion: The projection-based and the global correction yield visually indistinguishable SPECT images. The global correction based on sparse sampling of projections losses allows for accurate SPECT deadtime loss correction while keeping the study duration reasonable.

60 APPLIED LIFE SCIENCES↗

Observational needs for estimating Alaskan soil carbon stocks under current and future climate

Abstract Representing land surface spatial heterogeneity when designing observation networks is a critical scientific challenge. Here we present a geospatial approach that utilizes the multivariate spatial heterogeneity of soil‐forming factors—namely, climate, topography, land cover types, and surficial geology—to identify observation sites to improve soil organic carbon (SOC) stock estimates across the State of Alaska, USA. Standard deviations in existing SOC samples indicated that 657, 870, and 906 randomly distributed pedons would be required to quantify the average SOC stocks for 0–1 m, 0–2 m, and whole‐profile depths, respectively, at a confidence interval of 5 kg C m −2 . Using the spatial correlation range of existing SOC samples, we identified that 309, 446, and 484 new observation sites are needed to estimate current SOC stocks to 1 m, 2 m, and whole‐profile depths, respectively. We also investigated whether the identified sites might change under future climate by using eight decadal (2020–2099) projections of precipitation, temperature, and length of growing season for three representative concentration pathway (RCP 4.5, 6.0, and 8.5) scenarios of the Intergovernmental Panel on Climate Change. These analyses determined that 12 to 41 additional sites (906 + 12 to 41; depending upon the emission scenarios) would be needed to capture the impact of future climate on Alaskan whole‐profile SOC stocks by 2100. The identified observation sites represent spatially distributed locations across Alaska that captures the multivariate heterogeneity of soil‐forming factors under current and future climatic conditions. This information is needed for designing monitoring networks and benchmarking of Earth system model results.

54 ENVIRONMENTAL SCIENCES↗

Implantation of sodium ions into germanium

The donor properties of Na atoms introduced by ion implantation into p-Ge with the resistivity 20-40 {Omega} cm are established for the first time. Na profiles implanted into Ge (the energies 70 and 77 keV and the doses (0.8, 3, 30) Multiplication-Sign 10{sup 14} cm{sup -2}) are studied. The doses and annealing temperatures at which the thermoprobe detects n-type conductivity on the sample surface are established. After implantation, the profiles exhibit an extended tail. The depth of the concentration maximum is in good agreement with the calculated mean projected range of Na ions R{sub p}. Annealing for 30 min at temperatures of 250-700 Degree-Sign C brings about a redistribution of Na atoms with the formation of segregation peaks at a depth, which is dependent on the ion dose, and is accompanied by the diffusion of Na atoms to the surface with subsequent evaporation. After annealing at 700 Degree-Sign C less than 7% of the implanted ions remain in the matrix. The shape of the profile tail portions measured after annealing at temperatures 300-400 Degree-Sign C is indicative of the diffusion of a small fraction of Na atoms into the depth of the sample.

36 MATERIALS SCIENCE↗