Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pressure measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Pronghorn Porous Media Model Validation with Pressure Drop Measurements

The verification and validation (V&V) of Pronghorn is imperative to assert its accuracy when predicting the fluid velocity, temperature, and pressure in high temperature gas-cooled reactors. Pronghorn is a coarse-mesh, intermediate-fidelity, and multidimensional thermal-hydraulics (TH) code developed by the Idaho National Laboratory (INL). New pebble bed experiments are used to observe the details of the fluid motion and pressure drop in the porous bed under the reactor normal operation. This paper focuses on the validation of the Pronghorn compressible and incompressible Navier-Stokes equations using the pressure drop measurements performed at the engineering-scale pebble bed facility at the Texas A&M university (TAMU). Various pressure drop correlations and porosity functions are implemented in both Pronghorn and STAR-CCM+ to compare the pressure drop due to the combined viscous and inertial resistances in the porous bed. The correlations accounting for the near-wall effect are also utilized to observe if the pressure drop estimates can be improved. Pronghorn porous media models predict the pressure drop well relative to the STAR-CCM+ simulation results and 1D correlations, and both the finite element method (FEM) and finite volume method (FVM) perform accurately. Pronghorn models are also validated with the experimental measurements given the different Reynolds number ranges and specific aspect ratios. The likelihood of the statistical significance between the pressure drop measurements and specific correlations or simulations is low provided that the overlap of their confidence intervals is more than the half of a single arm. Several validation metrics are reasonable in regard to the similar studies from other literature. The precise average pebble bed porosity estimation has much impact on the pressure drop, and the Foumeny and Montillet (dense packing) models carry out the accurate pressure drop prediction by considering the near-wall effect.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Estimation of the viscosities of silicate liquids at high pressure from measurements of oxygen diffusivity

The dynamics and evolution of a magma ocean depend significantly on the structure and physical properties of silicate liquids at high pressure. Viscosity is particularly important because of its effect on the dynamics of convection and crystal setting. Traditionally, the viscosities of silicate liquids have been measured at high pressure by falling sphere viscometry but, due to some limitations of this technique, few measurements have been made at pressures exceeding 2.5 GPa. An alternative approach, which has previously been proven up to 2 GPa, is to use high pressure measurements of oxygen self-diffusivity (D) to estimate viscosity (eta) from the Eyring relationship eta = kT/D lambda (where k is the Boltzmann constant, T is absolute temperature, and lambda is the diffusive jump distance). We have performed preliminary experiments on Na2Si4O9 liquid in order to explore the feasibility of this method up to pressures in excess of 10 GPa. Diffusion couples were prepared from glass starting materials with one half of the sample enriched in O-18 and the other half containing the natural abundance (0.2 wt percent). Diffusion experiments were performed at 1600 to 1800 C at pressures in the range of 2.5 to 10 GPa for times up to 6 minutes using a 1200 ton multianvil apparatus. Oxygen diffusivities were derived from the resulting O-18 concentration profiles, which were analyzed using an ion microprobe. At 1800 C, oxygen diffusivities increase continuously from 1 x 10(exp -10) m(exp -2) s(exp -1) at 2.5 Gpa to 5 x 10(exp -10) m(exp -2) s(exp -1) at 10 GPa. From the Eyring relationship, the viscosity of Na2SiO9 liquid is predicted to decrease by approx. 0.7 log units over this pressure range at 1800 C. These trends, which can be related to changes in the structure of the liquid at high pressure, are in agreement with results of molecular dynamics calculations. These results suggest that it should be possible to estimate the viscosities of silicate liquids up to at least 15 GPa and 2200 C by this method.

Rubie, D. C.↗

Pressure-Distribution Measurements on Unyawed Swept-Back Wings

This report presents comprehensive pressure-distribution measurements on four (4) swept-back wings (phi = 0 deg, 15 deg, 30 deg, and 45 deg) of constant chord and over a large range of angles of attack with symmetrical air flow. The distributions, experimentally obtained, were compared with theoretical ones calculated by the methods of Weissinger and Multhopp.

Jacobs, W.↗

Voltage-To-Frequency Converter For Pressure Calibration

Measurements of pressures on walls of wind tunnels and on surfaces of models in wind tunnels made with help of electronically scanned pressure-measurement (ESP) system. Voltage-to-frequency converter circuit, designed to convert 0- to 5-Vdc analog output voltage from high-line-pressure, low-differential-pressure standard to required frequency range. Enables selection of wider variety of high-accuracy pressure standards to enhance accuracy of measurement of ESP instrumentation while requiring little modification of manufacturer's system and no modification of operating software of system. Useful primarily in wind-tunnel instrumentation and readily adaptable to commercial instruments currently in use.

Sealey, Bradley S.↗

Wide-range dynamic pressure sensor

Transducer measures pressure by sensing the damping of a vibrating diaphragm immersed in the atmosphere to be measured. Improved sensor can be included in rugged, lightweight package for use aboard aircraft, meteorological vehicles, and space probes.

Dimeff, J.↗

Optimization of measurements with pressure sensitive paints

Use of luminescent paints for the measurement of global pressures on wind tunnel model surfaces requires a full understanding of the inherent accuracy of the technique. Theoretical emission of the paint luminophor follows the well known Stern-Volmer relation. Inherent in this relation are fundamental limits to achievable sensitivity and accuracy. Equations for relative error in pressure as a function of relative signal intensity (emittance), relative error in pressure as a function of pressure, and the relationship between sensitivity and pressure are derived and represented graphically.

Oglesby, Donald M.↗

Measurements of pressures on the wing of an aircraft model during steady rotation

An investigation has been conducted in the Spin Tunnel Facility at the NASA Langley Research Center to measure the pressures on the wing surfaces of a model of a Basic Training Aircraft during steady rotation. The tests were made to determine the nature of the wing pressure distribution during rotations typical of spin entry and steady spin. Comparisons are made between the forces and moments obtained from integrating the pressure field with those measured directly during rotary balance force tests. The results are also compared with estimates determined from a simple numerical model of the wing aerodynamic forces.

Martin, Colin A.↗

Study of noise sources in a subsonic fan using measured blade pressures and acoustic theory

Sources of noise in a 1.4 m (4.6 ft) diameter subsonic tip speed propulsive fan running statically outdoors are studied using a combination of techniques. Signals measured with pressure transducers on a rotor blade are plotted in a format showing the space-time history of inlet distortion. Study of these plots visually and with statistical correlation analysis confirms that the inlet flow contains long, thin eddies of turbulence. Turbulence generated in the boundary layer of the shroud upstream of the rotor tips was not found to be an important noise source. Fan noise is diagnosed by computing narrowband spectra of rotor and stator sound power and comparing these with measured sound power spectra. Rotor noise is computed from spectra of the measured blade pressures and stator noise is computed using the author's stator noise theory. It is concluded that the rotor and stator sources contribute about equally at frequencies in the vicinity of the first three harmonics of blade passing frequency. At higher frequencies, the stator contribution diminishes rapidly and the rotor/inlet turbulence mechanism dominates. Two parametric studies are performed by using the rotor noise calculation procedure which was correlated with test. In the first study, the effects on noise spectrum and directivity are calculated for changes in turbulence properties, rotational Mach number, number of blades, and stagger angle. In the second study the influences of design tip speed and blade number on noise are evaluated.

Hanson, D. B.↗

Identification and measurement of combustion noise from a turbofan engine using correlation and coherence techniques

Fluctuating pressure measurements within the combustor and tailpipe of a turbofan engine are made simultaneously with far field acoustic measurements. The pressure measurements within the engine are accomplished with cooled semi-infinite waveguide probes utilizing conventional condenser microphones as the transducers. The measurements are taken over a broad range of engine operating conditions and for 16 far field microphone positions between 10 deg and 160 deg relative to the engine inlet axis. Correlation and coherence techniques are used to determine the relative phase and amplitude relationships between the internal pressures and far field acoustic pressures. The results indicate that the combustor is a low frequency source region for acoustic propagation through the tailpipe and out to the far field. Specifically, it is found that the relation between source pressure and the resulting sound pressure involves a 180 deg phase shift. The latter result is obtained by Fourier transforming the cross correlation function between the source pressure and acoustic pressure after removing the propagation delay time. Further, it is found that the transfer function between the source pressure and acoustic pressure has a magnitude approximately proportional to frequency squared. These results are shown to be consistent with a model using a modified source term in Lighthill's turbulence stress tensor, wherein the fluctuating Reynolds stresses are replaced with the pressure fluctuations due to fluctuating entropy.

Karchmer, A. M.↗

Instrument measures dynamic pressure fluctuations

Pressure probe instrument, incorporating "infinite line" principle, can be used to remotely measure dynamic pressure fluctuations in hot high-pressure environemnts too severe for sensors. System is designed and can be utilized for measurements in core of operating turbofan engine.

Coats, J. W.↗

Experimental Investigation of Unsteady Shock Wave Turbulent Boundary Layer Interactions About a Blunt Fin

A series of experiments were performed to investigate the effects of Mach number variation on the characteristics of the unsteady shock wave/turbulent boundary layer interaction generated by a blunt fin. A single blunt fin hemicylindrical leading edge diameter size was used in all of the experiments which covered the Mach number range from 2.0 to 5.0. The measurements in this investigation included surface flow visualization, static and dynamic pressure measurements, both on centerline and off-centerline of the blunt fin axis. Surface flow visualization and static pressure measurements showed that the spatial extent of the shock wave/turbulent boundary layer interaction increased with increasing Mach number. The maximum static pressure, normalized by the incoming static pressure, measured at the peak location in the separated flow region ahead of the blunt fin was found to increase with increasing Mach number. The mean and standard deviations of the fluctuating pressure signals from the dynamic pressure transducers were found to collapse to self-similar distributions as a function of the distance perpendicular to the separation line. The standard deviation of the pressure signals showed initial peaked distribution, with the maximum standard deviation point corresponding to the location of the separation line at Mach number 3.0 to 5.0. At Mach 2.0 the maximum standard deviation point was found to occur significantly upstream of the separation line. The intermittency distributions of the separation shock wave motion were found to be self-similar profiles for all Mach numbers. The intermittent region length was found to increase with Mach number and decrease with interaction sweepback angle. For Mach numbers 3.0 to 5.0 the separation line was found to correspond to high intermittencies or equivalently to the downstream locus of the separation shock wave motion. The Mach 2.0 tests, however, showed that the intermittent region occurs significantly upstream of the separation line. Power spectral densities measured in the intermittent regions were found to have self-similar frequency distributions when compared as functions of a Strouhal number for all Mach numbers and interaction sweepback angles. The maximum zero-crossing frequencies were found to correspond with the peak frequencies in the power spectra measured in the intermittent region.

Barnhart, Paul J.↗

Intramuscular pressure varies with depth. The tibialis anterior muscle studied in 12 volunteers

Pressures in the tibialis anterior muscle were recorded at rest and during exercise with transducer-tipped catheters in 12 volunteers while they were supine or standing. The recordings were repeated with venous stasis created by an inflated tourniquet cuff on the thigh. Catheters were placed at 3 different sites in the muscle: catheter I adjacent to the deep surface of the fascia over the anterior compartment; catheter II between the fascia and the central tendon; and catheter III deep in the muscle close to the interosseous membrane. In both the supine and standing positions the intramuscular pressure at rest and the muscle relaxation pressure during exercise, obtained by catheter II, were greater than the corresponding pressures measured by the superficially located catheter I in the normal as well as in the volume loaded limb. The same conditions for pressure measurement consistently revealed lower pressures recorded by catheter III compared to II, but the difference was not significant. Our results indicate that intramuscular pressure increases centripetally, as the centrally lying tendon is approached. We conclude that pressure measurements for diagnosis of acute and chronic compartment syndromes and in ergonomic studies should be based on recordings from a standard location of the catheter within the muscle and a standard posture of the subject.

NASA Discipline Musculoskeletal↗

High-Area-Ratio Rocket Nozzle at High Combustion Chamber Pressure: Experimental and Analytical Validation

Experimental data were obtained on an optimally contoured nozzle with an area ratio of 1025:1 and on a truncated version of this nozzle with an area ratio of 440:1. The nozzles were tested with gaseous hydrogen and liquid oxygen propellants at combustion chamber pressures of 1800 to 2400 psia and mixture ratios of 3.89 to 6.15. This report compares the experimental performance, heat transfer, and boundary layer total pressure measurements with theoretical predictions of the current Joint Army, Navy, NASA, Air Force (JANNAF) developed methodology. This methodology makes use of the Two-Dimensional Kinetics (TDK) nozzle performance code. Comparisons of the TDK-predicted performance to experimentally attained thrust performance indicated that both the vacuum thrust coefficient and the vacuum specific impulse values were approximately 2.0-percent higher than the turbulent prediction for the 1025:1 configurations, and approximately 0.25-percent higher than the turbulent prediction for the 440:1 configuration. Nozzle wall temperatures were measured on the outside of a thin-walled heat sink nozzle during the test fittings. Nozzle heat fluxes were calculated front the time histories of these temperatures and compared with predictions made with the TDK code. The heat flux values were overpredicted for all cases. The results range from nearly 100 percent at an area ratio of 50 to only approximately 3 percent at an area ratio of 975. Values of the integral of the heat flux as a function of nozzle surface area were also calculated. Comparisons of the experiment with analyses of the heat flux and the heat rate per axial length also show that the experimental values were lower than the predicted value. Three boundary layer rakes mounted on the nozzle exit were used for boundary layer measurements. This arrangement allowed total pressure measurements to be obtained at 14 different distances from the nozzle wall. A comparison of boundary layer total pressure profiles and analytical predictions show good agreement for the first 0.5 in. from the nozzle wall; but the further into the core flow that measurements were taken, the more that TDK overpredicted the boundary layer thickness.

Jankovsky, Robert S.↗

Pressure-Distribution Measurements of a Model of a Davis Wing Section with Fowler Flap Submitted by Consolidated Aircraft Corporation

Wing pressure distribution diagrams for several angles of attack and flap deflections of 0 degrees, 20 degrees, and 40 degrees are presented. The normal force coefficients agree with lift coefficients obtained in previous test of the same model, except for the maximum lifts with flap deflection. Pressure distribution measurements were made at Reynolds Number of about 6,000,000.

PRESSURE DISTRIBUTION - AIRFOILS - DAVIS↗

A High-speed Engine Pressure Indicator of the Balanced Diaphragm Type

This report describes a pressure-measuring device especially adapted for use in mapping indicator diagrams of high-speed internal combustion engines. The cards are obtained by a point-to-point method giving the average of a large number of engine cycles. The principle involved is the balancing of the engine cylinder pressure against a measured pressure on the opposite side of the metal a diaphragm of negligible stiffness. In its application as an engine indicator the phase of the engine cycle to which a pressure measurement corresponds is selected by a timing device. The report discusses briefly the errors which must be avoided in the development of an indicator for light high-speed engines, where vibration is serious, and outlines the principles underlying the design of this instrument in order to be free of such errors. A detailed description of the instrument and accessories follows together with operating directions.

Dickinson, H C↗

Beat-to-Beat Blood Pressure Monitor

This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes. Photoplethysmography, which measures changes in arterial blood volume, is commonly used to obtain heart rate and blood oxygen saturation. The digitized PPG signals are used as inputs into the beat-to-beat blood pressure measurement algorithm.

Lee, Yong Jin↗

Pressure-Distribution Measurements at Large Angles of Pitch on Fins of Different Span-Chord Ratio on a 1/40-Scale Model of the U. S. Airship "Akron."

Report presents the results of pressure-distribution measurements on a 1/40-scale model of the U. S. Airship "Akron" conducted in the NACA 20-foot wind tunnel. The measurements were made on the starboard fin of each of four sets of horizontal tail surfaces, all of approximately the same area but differing in span-chord ratio, for five angles of pitch varying from 11.6 degrees to 34 degrees, for four elevator angles, and at air speeds ranging from 56 to 77 miles per hour. Pressures were also measured at 13 stations along the rear half of the port side of the hull at one elevator setting for the same five angles of pitch and at an air speed of approximately 91 miles per hour. The normal force on the fin and the moment of forces about the fin root were determined. The results indicate that, ignoring the effect on drag, it would be advantageous from structural considerations to use a fin of lower span-chord ratio than that used on the "Akron."

Mchugh, James G↗