Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Practice Guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

TH-C-18C-01: MRI Safety

Clinical diagnostic medical physicists may be responsible for implementing and maintaining a comprehensive MR safety program. Accrediting bodies including the ACR, IAC, Radsite and The Joint Commission each include aspects of MR Safety into their imaging accreditation programs; MIPPA regulations further raise the significance of non-compliance. In addition, The Joint Commission recently announced New and Revised Diagnostic Imaging Standards for accredited health care organizations which include aspects of MR Safety. Hospitals and clinics look to the physicist to understand guidelines, regulations and accreditation requirements related to MR safety. The clinical medical physicist plays a significant role in a clinical practice by understanding the physical basis for the risks and acting as a facilitator to successfully implement a safety program that provides well-planned siting, allows for the safe scanning of certain implanted devices, and helps radiologists manage specific patient exams. The MRI scanning of specific devices will be discussed including cardiac pacemakers and neurostimulators such as deep brain stimulators. Furthermore for sites involved in MR guided interventional procedures, the MR physicist plays an essential role to establish safe practices. Creating a framework for a safe MRI practice includes the review of actual safety incidents or close calls to determine methods for prevention in the future. Learning Objectives: Understand the requirements and recommendations related to MR safety from accrediting bodies and federal regulations. Understand the Medical Physicist's roles to ensure MR Safety. Identify best practices for dealing with implanted devices, including pacemakers and deep brain stimulators. Review aspects of MR safety involved in an MR guided interventional environment. Understand the important MR safety aspects in actual safety incidents or near misses.

60 APPLIED LIFE SCIENCES↗

Non-routine adjustments – towards standardizing M&V approach for quantifying the effects of static factors

The success of an energy management program relies on ensuring that the energy savings can be verified with an adequate level of certainty. Energy savings cannot be directly measured and hence have to be deduced by comparing the pre-retrofit energy consumption with post-retrofit energy consumption data adjusted to account for differences in conditions. These adjustments are needed, since conditions that influence energy consumption may not stay the same between pre- and postinstallation phase of the project. These adjustments can often be routine when accounting for factors like production volume and weather that are expected to change and are included in the energy consumption adjustment model. Existing measurement and verification (M&V) resources and guidance mostly concentrate on developing models for routine adjustment of one or more factors that normally change. On the other hand, there are factors (static) like product mix, operating hours, gross square area, etc. that are assumed to stay constant during normal conditions. However, in order to adapt to dynamic market conditions, the industries are forced to react thereby leading to changes to these static factors. Identifying these static factors that warrant adjustment, called non-routine event, along with quantifying their effect on energy consumption can be complex and lack of proper guidance can exacerbate this issue. This paper reviews some of the current work in terms of how non-routine events are defined, characterized, detected and quantified based on a review of existing M&V guidelines, protocols and other relevant literature. This work also reviewed some of the existing non-routine events and adjustment practices to understand how these different aspects are addressed along with a discussion on some of the key challenges and gaps in the current guidance.

Earni, Shankar↗

Apollo experience report: Pressure vessels

The Apollo spacecraft pressure vessels, associated problems and resolutions, and related experience in evaluating potential problem areas are discussed. Information is provided that can be used as a guideline in the establishment of baseline criteria for the design and use of lightweight pressure vessels. One of the first practical applications of the use of fracture-mechanics technology to protect against service failures was made on Apollo pressure vessels. Recommendations are made, based on Apollo experience, that are designed to reduce the incidence of failure in pressure-vessel operation and service.

Ecord, G. M.↗

The prevention of electronical breakdown and electrostatic voltage problems in the space shuttle and its payloads. Part 2: Design guides and operations considerations

The specific electrical discharge problems that can directly affect the shuttle vehicle and its payloads are addressed. General design guidelines are provided to assist flight hardware managers in minimizing these kinds of problems. Specific data are included on workmanship practices and system testing while in low pressure environments. Certain electrical discharge problems that may be unique to the design of the shuttle vehicle itself and to its various mission operational models are discussed.

Whitson, D. W.↗

NASA reliability preferred practices for design and test

Given here is a manual that was produced to communicate within the aerospace community design practices that have contributed to NASA mission success. The information represents the best technical advice that NASA has to offer on reliability design and test practices. Topics covered include reliability practices, including design criteria, test procedures, and analytical techniques that have been applied to previous space flight programs; and reliability guidelines, including techniques currently applied to space flight projects, where sufficient information exists to certify that the technique will contribute to mission success.

Source record↗

Connected Lighting Systems Efficiency Study: PoE Cable Energy Losses, Part 2

DOE published a report in November 2017 (herein referred to as “Part 1”) summarizing the results of an exploratory study investigating power losses in Ethernet cables used between PoE switches and luminaires in PoE connected lighting systems. Testing was conducted at the Pacific Northwest National Laboratory (PNNL) Connected Lighting Test Bed (CLTB) in September 2017. The results were analyzed to explore the impact of cable selection on PoE lighting system energy efficiency, as well as the effectiveness of guidelines published by the American National Standards Institute (ANSI) C137 Lighting Systems Committee in 2017. The guidance offered in ANSI C137.3-2017 was found to be effective in limiting cable energy losses to 5% in PoE lighting applications, provided that the average cable length on a project does not exceed 50 m. This Part 2 report summarizes the results of a continued investigation of the power losses in Ethernet cables used between PoE switches and luminaires in PoE connected lighting systems. Testing was conducted at the PNNL CLTB in July-August 2018. A test setup comprising a PoE switch, a set of luminaires, and a reference meter was again used to test multiple cable models of varying design. The results were analyzed to explore the impact of cable selection and installation practices (e.g., cable bending, cable bundling, and installation in conduit) on PoE lighting system energy efficiency, as well as the effectiveness of the ANSI C137.3 guidelines. Notably, three cables—two of which were shielded—were previously excluded from the Part 1 study due to compatibility issues. All three cables were included in this Part 2 study, along with a fourth model cable introduced in Part 2. In addition, whereas no patch cords were used in Part 1, patch cords were used in some Part 2 testing. The ANSI C137.3 guidance was again shown to effectively limit power losses to less than 5% in the cables tested (varying in AWG, Category, shielding, fire rating, and manufacturer), and AWG again proved to be the most important cable design variable for energy performance, as expected. However, these findings should not be construed as being representative of all cable models and installation practices. For example, energy losses would be greater when cables are connected to patch cords, bundled in conduit, and loaded with powered devices (PDs) approaching 100 W input power. The other key finding was that with 44 W luminaires as PDs and room ambient temperatures below 30°C, cable energy losses were not substantially increased by cable bending or bundling in uninsulated conduit. However, environments with higher ambient temperatures will have greater energy losses due to increased conductor DCR. In addition, product selection and installation practices will have increased importance as PDs approaching 100 W input power—conveyed by a single Ethernet cable—are introduced following publication of the forthcoming Institute of Electrical and Electronics Engineers (IEEE) Standard 802.3bt. The report also provides recommendations and next steps, which include plans for additional PoE cable energy losses testing with higher-power PDs to more fully explore the potential of PoE lighting systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Value of Successful MBSE Adoption

The value of successful adoption of Model Based System Engineering (MBSE) practices is hard to quantify. Most engineers and project managers look at the success in terms of cost. But there are other ways to quantify the value of MBSE and the steps necessary to achieve adoption. The Glenn Research Center (GRC) has been doing Model-Based Engineering (design, structural, etc.) for years, but the system engineering side has not. Since 2010, GRC has been moving from documents centric to MBSE/SysML. Project adoption of MBSE has been slow, but is steadily increasing in both MBSE usage and complexity of generated products. Sharing of knowledge of lessons learned in the implementation of MBSE/SysML is key for others who want to be successful. Along with GRC's implementation, NASA is working hard to increase the successful implementation of MBSE across all the other centers by developing guidelines, templates and libraries for projects to utilize. This presentation will provide insight into recent GRC and NASA adoption efforts, lessons learned and best practices.

MBSE↗

TU-B-16A-01: To Which Journal Should I Submit My Paper

Research papers authored by Medical Physicists address a large spectrum of oncologic, imaging, or basic research problems; exploit a wide range of physical and engineering methodologies; and often describe the efforts of a multidisciplinary research team. Given the large number (about 100) competing journals accepting medical physics articles, it may not be clear to an individual author which journal is the best venue for disseminating their work to the scientific community. Relevant factors usually include the Journal’s audience and scientific impact, but also such factors as perceived acceptance rate, interest in their topic, and quality of service. The purpose of this symposium is to provide the medical physics community with an overview of scope, review processes, and article guidelines for the following journals: Medical Physics, International Journal of Radiation Biology and Physics, Journal of Applied Clinical Medical Physics, and Practical Radiation Oncology. The senior editors for each journal will provide details as to the journals review process, for example: single blind versus double blind reviews; the hierarchy of the review process in terms of editorial board structure; the reality of acceptance, in terms of acceptance rate; and the types of research the journal prefers to publish. The goal is to provide for authors guidance before they begin to write their papers, not only for proper formatting, but also that the readership is appropriate for the particular paper, hopefully increasing the likelihood of publication. Learning Objectives: To review each Journal’s submission and review process Guidance as to how to increase chances of acceptance To help decipher which journal is appropriate for a given work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Integrated Data Collection Analysis (IDCA) Program - RDX Type II Class 5 Standard, Data Set 1

This document describes the results of the first reference sample material—RDX Type II Class 5—examined in the proficiency study for small-scale safety and thermal (SSST) testing of explosive materials for the Integrated Data Collection Analysis (IDCA) Program. The IDCA program is conducting proficiency testing on homemade explosives (HMEs). The reference sample materials are being studied to establish the accuracy of traditional explosives safety testing for each performing laboratory. These results will be used for comparison to results from testing HMEs. This effort, funded by the Department of Homeland Security (DHS), ultimately will put the issues of safe handling of these materials in perspective with standard military explosives. The results of the study will add SSST testing results for a broad suite of different HMEs to the literature, potentially suggest new guidelines and methods for HME testing, and possibly establish what are the needed accuracies in SSST testing to develop safe handling practices. Described here are the results for impact, friction, electrostatic discharge, and scanning calorimetry analysis of a reference sample of RDX Type II Class 5. The results from each participating testing laboratory are compared using identical test material and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. These results are then compared to historical data from various sources. The performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Air Force Research Laboratory/ RXQL (AFRL), Indian Head Division, Naval Surface Warfare Center, (IHD-NSWC), and Sandia National Laboratories (SNL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when test protocols are not identical.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Long-Term Information Management (LTIM) of Safeguards Data at Repositories: Phase II

One of the challenges of implementing safeguards for geological repositories will be the long-term preservation of safeguards-related data for 100 years or more. While most countries considering the construction and operation of such facilities agree that safeguards information should be preserved, there are gaps with respect to standardized requirements, guidelines, timescales, and approaches. This study analyzes those gaps and explores research to clarify stakeholder needs, identify current policies, approaches, best practices and international standards, and explores existing safeguards information management infrastructure. The study also attempts to clarify what a safeguards data classification system might look like, how long data should be retained, and how information should be exchanged between stakeholders at different phases of a repository’s life cycle. The analysis produced a variety of recommendations on what information to preserve, how to preserve it, where to store it, retention options and how to exchange information in the long term. Key findings include the use of the globally recognized international records management standard, ISO15489, for guidance on the development of information management systems, and the development of a Key Information File (KIF). The KIF could be used to identify only the most relevant, high-level safeguards information and the history of decision making about the repository. The study also suggests implementing on-site and off-site records storage in digital and physical form; developing a safeguards data classification system; long-term records retention with periodic reviews every 5 to 10 years during each phase of the repository life cycle; and establishing transition procedures well in advance so that data shepherds and records officers can transfer information with incoming facility managers effectively and efficiently. These and other recommendations are further analyzed in this study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

As-Run Neutronic Calculations of HFIR Mini-Fuel Experiments: Guidelines for Analysts

This report provides guidelines for analysts performing radiation transport calculations for mini-fuel experiments irradiated in the High Flux Isotope Reactor (HFIR). Procedures, practical recommendations, and modeling conventions which are essential to ensuring consistency and high fidelity in as-run simulations have been compiled. The content is intended to be a portion of the official training material for new staff in this area, offering both technical references and practical guidance derived from previous experience. This report is a living document and will be periodically updated to incorporate new developments, methodological improvements, and lessons learned from ongoing and future irradiation campaigns.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computer systems and software engineering

The High Technologies Laboratory (HTL) was established in the fall of 1982 at the University of Houston Clear Lake. Research conducted at the High Tech Lab is focused upon computer systems and software engineering. There is a strong emphasis on the interrelationship of these areas of technology and the United States' space program. In Jan. of 1987, NASA Headquarters announced the formation of its first research center dedicated to software engineering. Operated by the High Tech Lab, the Software Engineering Research Center (SERC) was formed at the University of Houston Clear Lake. The High Tech Lab/Software Engineering Research Center promotes cooperative research among government, industry, and academia to advance the edge-of-knowledge and the state-of-the-practice in key topics of computer systems and software engineering which are critical to NASA. The center also recommends appropriate actions, guidelines, standards, and policies to NASA in matters pertinent to the center's research. Results of the research conducted at the High Tech Lab/Software Engineering Research Center have given direction to many decisions made by NASA concerning the Space Station Program.

Mckay, Charles W.↗

CLASSY. II. A Technical Overview of the COS Legacy Archive Spectroscopic Survey

The COS Legacy Archive Spectroscopic SurveY (CLASSY) is designed to provide the community with a spectral atlas of 45 nearby star-forming galaxies that were chosen to cover similar properties to those seen at high z (z > 6). The prime high-level science product of CLASSY is accurately coadded UV spectra, ranging from ∼1000 to 2000 Å, derived from a combination of archival and new data obtained with HST's Cosmic Origins Spectrograph (COS). This paper details the multistage technical processes of creating this prime data product and the methodologies involved in extracting, reducing, aligning, and coadding far-ultraviolet and near-ultraviolet (NUV) spectra. We provide guidelines on how to successfully utilize COS observations of extended sources, despite COS being optimized for point sources, and best-practice recommendations for the coaddition of UV spectra in general. Moreover, we discuss the effects of our reduction and coaddition techniques in the scientific application of the CLASSY data. In particular, we find that accurately accounting for flux calibration offsets can affect the derived properties of the stellar populations, while customized extractions of NUV spectra for extended sources are essential for correctly diagnosing the metallicity of galaxies via C iii] nebular emission. Despite changes in spectral resolution of up to ∼25% between individual data sets (due to changes in the COS line-spread function), no adverse affects were observed on the difference in velocity width and outflow velocities of isolated absorption lines when measured in the final combined data products, owing in part to our signal-to-noise regime of S/N < 20.

Bethan L. James↗

Experts' perspective on the performance of Chinese technical guidelines for Plan Environmental Impact Assessment

This research was to evaluate the Technical Guideline (HJ/T130-2003) effectiveness based on data resource from a questionnaire survey and interviews on EIA experts. The result demonstrated that the guideline served mainly as a quality control measure for PEIA products, and only a small proportion of experts considered it effective due to its inconsistency with the newly released Chinese PEIA Regulation (2009) and poor practicability. Current status of SEA implementation in China was also studied in terms of application fields, effectiveness evaluation, and major issues to affect SEA, to conclude that SEA implementation in China is premature, and with limited effectiveness. The major problem was the lack of effective methodologies and technical tools. Recommendations for revising the PEIA Guideline and advices to improving SEA implementation in China were accordingly proposed.

54 ENVIRONMENTAL SCIENCES↗

Expert Radiation Oncologist Interpretations of Involved-Site Radiation Therapy Guidelines in the Management of Hodgkin Lymphoma

Purpose: Recently, involved-site radiation therapy (ISRT) guidelines have been developed and published to replace the previous concept of involved-field radiation therapy for patients with lymphoma. However, these ISRT guidelines may be interpreted in different ways, posing difficulties for prospective clinical trials. This study reports survey results regarding interpretation of the ISRT guidelines. Methods and Materials: Forty-four expert lymphoma radiation oncologists were asked to participate in a survey that included 7 different cases associated with 9 questions. The questions pertained to ISRT contouring and asked respondents to choose between 2 different answers (no “correct” answer) and a third write-in option allowed. Results: Fifty-two percent of those surveyed responded to the questionnaire. Among those who responded, 72% have practiced for >10 years, 46% have treated >20 Hodgkin lymphoma cases annually, and 100% were familiar with the ISRT concept. Among the 9 questions associated with the 7 cases, 3 had concordance among the expert radiation oncologists of greater than 70%. Six of the questions had less than 70% concordance (range, 56%-67%). Conclusions: Even among expert radiation oncologists, interpretation of ISRT guidelines is variable. Further guidance for ISRT field design will be needed to reduce variability among practicing physicians.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Health Economics in Radiation Oncology: A Systematic Review

Purpose: Despite the rising costs in radiation oncology, the impact of health economics research on radiation therapy practice analysis patterns is unclear. We performed a systematic review of cost-effectiveness analyses (CEAs) and cost-utility analyses (CUAs) to identify trends in reporting quality in the radiation oncology literature over time. Methods and Materials: A systematic review of radiation oncology economic evaluations up to 2014 was performed, using MEDLINE and EMBASE databases. The Consolidated Health Economic Evaluation Reporting Standards guideline informed data abstraction variables including study demographics, economic parameters, and methodological details. Tufts Medical Center CEA registry quality scores provided a basis for qualitative assessment of included studies. Studies were stratified by 3 time periods (1995-2004, 2005-2009, and 2010-2014). The Cochran-Armitage trend test and linear trend test were used to identify trends over time. Results: In total, 102 articles were selected for final review. Most studies were in the context of a model (61%) or clinical trial (28%). Many studies lacked a conflict of interest (COI) statement (67%), a sponsorship statement (48%), a reported study time horizon (35%), and the use of discounting (29%). There was a significant increase over time in the reporting of a COI statement (P<.001), health care payer perspective (P=.019), sensitivity analyses using multivariate (P=.043) or probabilistic methods (P=.011), incremental cost-effectiveness threshold (P<.001), secondary source utility weights (P=.010), and cost effectiveness acceptability curves (P=.049). There was a trend toward improvement in Tuft scores over time (P=.065). Conclusions: Recent reports demonstrate improved reporting rates in economic evaluations; however, there remains significant room for improvement as reporting rates are still suboptimal. As fiscal pressures rise, we will rely on economic assessments to guide our practice decisions and policies. We recommend improved adherence to published guidelines and further research to determine the clinical implications of our findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-E-204-00: Where to Send My Manuscript

Research papers authored by Medical Physicists address a large spectrum of oncologic, imaging, or basic research problems; exploit a wide range of physical and engineering methodologies; and often describe the efforts of a multidisciplinary research team. Given dozens of competing journals accepting medical physics articles, it may not be clear to an individual author which journal is the best venue for disseminating their work to the scientific community. Relevant factors usually include the Journal’s audience and scientific impact, but also such factors as perceived acceptance rate, interest in their topic, and quality of service. The purpose of this symposium is to provide the medical physics community with an overview of scope, review processes, and article guidelines for the following journals: Radiology, Medical Physics, International Journal of Radiation Biology and Physics, Journal of Applied Clinical Medical Physics, and Practical Radiation Oncology. Senior members of the editorial board for each journal will provide details as to the journals review process, for example: single blind versus double blind reviews; open access policies, the hierarchy of the review process in terms of editorial board structure; the reality of acceptance, in terms of acceptance rate; and the types of research the journal prefers to publish. Other journals will be discussed as well. The goal is to provide for authors guidance before they begin to write their papers, not only for proper formatting, but also that the readership is appropriate for the particular paper, hopefully increasing the quality and impact of the paper and the likelihood of publication. Learning Objectives: To review each Journal’s submission and review process Guidance as to how to increase quality, impact and chances of acceptance To help decipher which journal is appropriate for a given work A. Karellas, Research collaboration with Koning, Corporation.

60 APPLIED LIFE SCIENCES↗

WE-E-204-01: ASTRO Based Journals

Research papers authored by Medical Physicists address a large spectrum of oncologic, imaging, or basic research problems; exploit a wide range of physical and engineering methodologies; and often describe the efforts of a multidisciplinary research team. Given dozens of competing journals accepting medical physics articles, it may not be clear to an individual author which journal is the best venue for disseminating their work to the scientific community. Relevant factors usually include the Journal’s audience and scientific impact, but also such factors as perceived acceptance rate, interest in their topic, and quality of service. The purpose of this symposium is to provide the medical physics community with an overview of scope, review processes, and article guidelines for the following journals: Radiology, Medical Physics, International Journal of Radiation Biology and Physics, Journal of Applied Clinical Medical Physics, and Practical Radiation Oncology. Senior members of the editorial board for each journal will provide details as to the journals review process, for example: single blind versus double blind reviews; open access policies, the hierarchy of the review process in terms of editorial board structure; the reality of acceptance, in terms of acceptance rate; and the types of research the journal prefers to publish. Other journals will be discussed as well. The goal is to provide for authors guidance before they begin to write their papers, not only for proper formatting, but also that the readership is appropriate for the particular paper, hopefully increasing the quality and impact of the paper and the likelihood of publication. Learning Objectives: To review each Journal’s submission and review process Guidance as to how to increase quality, impact and chances of acceptance To help decipher which journal is appropriate for a given work A. Karellas, Research collaboration with Koning, Corporation.

61 RADIATION PROTECTION AND DOSIMETRY↗