Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Flow Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Aqueous Bromide Discharges from U.S. Coal-Fired Power Plants: Points of Origin, Concentration Ranges, and Effluent Treatment Costs

Bromide discharges from coal-fired power plants have received increased attention from regulatory bodies due to their contribution to the formation of disinfection byproducts (DBPs) in downstream drinking water treatment plants. Here, this paper characterizes the relative contributions of bromide from coal feedstocks and bromine-based mercury control processes, estimates the distribution of bromide concentrations at 85 active coal-fired power plants across the United States (U.S.) with wet flue gas desulfurization units, and estimates the cost of bromide removal from wastewater discharge using year 2020 data. Bromide discharges are estimated at the plant level using a combination of the reported coal rank and composition combusted, estimates of bromide addition in mercury control techniques under multiple halogen addition scenarios, and the estimated flue gas desulfurization (FGD) wastewater flow rate. The median, simulated plant-level estimation of total FGD wastewater flow is 18.3 gallons/min at a bromide concentration of 319 mg/L, equivalent to ~11.6 tonnes/year of bromide discharges to the environment. Next, we evaluated the expected cost of employing the best available technology (BAT) to control bromide discharges in FGD wastewater to prevent contributions to DBP formation. Treatment would need to remove more than 99.8% of bromide to reach the 0.2 mg/L voluntary incentive program (VIP) limit. The total cost of treatment depends on whether disposal is on- or off-site; the average costs for all plants combined come to an average of $110 million ($95.2/kgal) in 2021 U.S. dollars for on-site disposal, or $134 million ($115/kgal) for off-site disposal.

01 COAL, LIGNITE, AND PEAT↗

Evaluation of bio-inspired flow fields in a mediated Li-S flow battery for grid energy storage

Lithium-sulfur is a redox flow battery with high energy density for applications in safe, reliable, and lasting scaling of energy. However, lithium-based batteries often encounter platting as a problem thanks to poor Li-ions deposition after cycling. Aiming to reduce this impact, a uniform and continuous flow of ions is needed. On this work, novel bio-inspired flow fields in the electrochemical cell were tested to improve ions flowability and lithium platting control, ultimately enhancing battery performance and life. To secure Li-S efficient, low-cost, and secure energy storage capabilities, we chose a configuration with decamethylferrocene and cobaltocene acting as redox mediators, Li metal as anode and sulfur kept in a separate catholyte reservoir. Flow test and battery results insinuated a beneficial influence of bio-inspired designs in flowing electrolyte uniformly with less pressure and pump power in comparison to other conventional designs used in the industry, with an encouraging ability to approach a cheap, safe, and reliable Li-S grid energy storage.

25 ENERGY STORAGE↗

Resilient Operating Constraints for Power Distribution Systems under Setpoint Attacks

Integration and operation of distributed generation (DG) and energy storage (ES) in power distribution systems are enabled by communication networks and embedded sensor and control devices that increase the vulnerability of the systems to cyber-threats, broadening the attack surface and making adversary actions more unpredictable. This paper proposes a methodology that uses ellipsoidal approximations to quantify the potential damage caused by successful attacks that affect, directly or indirectly, the desired operation setpoints and may drive the power distribution operation to unsafe states by violating the limits of voltage or line flows. More specifically, a new methodology is introduced to find the optimal non-symmetric operating constraints that can be imposed to each DG and ES in order to guarantee that the power distribution system is resilient to any malicious setpoints. The proposed method takes as inputs the system topology, DG and ES capabilities, and load limits to solve a convex optimization problem formulated using linear matrix inequalities (LMIs) and the power flow equations. The proposed solution is agnostic to the attacker's action or load profile and it does not require any assumption about the location or means of the attack. The numerical results on a test distribution feeder with several DG and ES illustrate how the proposed resilient operating constraints guarantee the security of the power distribution system under setpoint attacks.

Giraldo, Jairo↗

Cyber-Informed Engineering Case Study of an Integrated Hydrogen Generation Plant

Strategies for securing digital instrumentation and control (I&C) systems within the nuclear industry are provided by multiple standards and guidance documents. However, since selection and use of security controls outlined in these documents are frequently only considered during or after installation, there are often limitations on their use, such as technological constraints related to design or operation. Furthermore, alternative controls intended to provide the same or similar security countermeasure as the primary control may also be infeasible at these stages, leaving the I&C system vulnerable to cyber-attacks. The limitations associated with ‘bolting on’ security controls late in the systems engineering lifecycle can be reduced by integrating Cyber-Informed Engineering (CIE) into the process. This paper evaluates the use of CIE during the high-level design stage of a hydrogen generation project where heat and electricity are provided by a nuclear power plant. Applying CIE to this project highlighted potential cyber vulnerabilities of the initial design, leading to recommendations for process flow and I&C system design modifications to reduce, and at times eliminate, the risk from both deliberate and unintentional cyber incidents.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Rapid QSTS Simulations for High-Resolution Comprehensive Assessment of Distributed PV

The rapid increase in penetration of distributed energy resources on the electric power distribution system has created a need for more comprehensive interconnection modeling and impact analysis. Unlike conventional scenario-based studies, quasi-static time-series (QSTS) simulations can realistically model time-dependent voltage controllers and the diversity of potential impacts that can occur at different times of year. However, to accurately model a distribution system with all its controllable devices, a yearlong simulation at 1-second resolution is often required, which could take conventional computers a computational time of 10 to 120 hours when an actual unbalanced distribution feeder is modeled. This computational burden is a clear limitation to the adoption of QSTS simulations in interconnection studies and for determining optimal control solutions for utility operations. The solutions we developed include accurate and computationally efficient QSTS methods that could be implemented in existing open-source and commercial software used by utilities and the development of methods to create high-resolution proxy data sets. This project demonstrated multiple pathways for speeding up the QSTS computation using new and innovative methods for advanced time-series analysis, faster power flow solvers, parallel processing of power flow solutions and circuit reduction. The target performance level for this project was achieved with year-long high-resolution time series solutions run in less than 5 minutes within an acceptable error.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control System Upgrade for Battery State-of-Charge Indications

The Advanced Test Reactor (ATR) Complex at Idaho National Laboratory (INL) relies on Battery Backed Power (BBP) systems and Uninterruptible Power Supplies (UPS) to ensure continuous power supply to critical components. This project aims to enhance the reliability and functionality of the battery monitoring and control systems by updating the State-of-Charge (SOC) system, Programmable Logic Controller (PLC), and Human-Machine Interface (HMI) for the nuclear safety-related battery banks. The current system, while functional, has areas for improvement, particularly in recharging calculations and alarm functions. The project objectives include developing flow charts, programming the new PLC and HMI, conducting bench tests, and updating design documentation. Additionally, the project ensures compliance with safety standards, develops training materials, creates comprehensive documentation, and integrates seamlessly with existing ATR infrastructure. The new SOC system is designed to be scalable for future upgrades, improve efficiency, enhance data accuracy, implement redundancy features, and achieve project goals within budget constraints while considering environmental impact. The methodology involved familiarizing with BBP and UPS systems, collecting current readings, rescaling signals, learning ladder logic, and updating the HMI. The transition from SLC 5/03 PLC using RS Logix 500 to CompactLogix 5380 using Studio 5000 was a key step. Despite challenges in transferring outdated PLC ladder logic and HMI code, starting from scratch led to a more accurate and efficient monitoring system, contributing to improved safety and operational efficiency. The project is currently awaiting approval of the Engineering Calculation and Analysis Report (ECAR) before implementation.

42 - ENGINEERING↗

Modeling and Validation of a Residential Multi-Functional Variable Refrigerant Flow Heat Pump System with Heat Recovery

To bridge the existing gap in modeling the variable refrigerant flow heat pump systems with heat recovery (VRFHR), we developed a suite of dynamic VRFHR system models in Modelica. These models are specifically tailored for residential multi-functional VRFHR (MF-VRFHR) applications, including space conditioning and domestic hot water (DHW) heating, utilizing both the TIL library for HVAC equipment and the Buildings library for thermal load calculations. The development comprises essential component models, including the newly developed heat recovery unit (HRU), along with system models that integrate the heat pump system and building envelope. These system models accommodate various operational modes such as heating-only, cooling-only, and heating-recovery (including heating-dominant and cooling-dominant) modes. Furthermore, we propose an efficient optimization-based model calibration method that identifies critical model parameters while utilizing a small amount of data obtained from either real systems or manufacturer's specifications. We demonstrate the effectiveness of these models and the proposed calibration method for a MF-VRFHR system installed in Richland, WA. The developed models are calibrated and validated using data collected under different operational modes during both heating and cooling seasons. The results show that the models capture the system dynamics and achieve high accuracy, with the coefficient of the variation of the root-mean-square-error less than 15% for variables such as outdoor unit power consumption, compressor speed, space temperature and DHW temperature. The validated models serve as a reliable representation of the MF-VRFHR system, facilitating the development and validation of optimized controls needed to realize the full benefits of integrated heat pump systems. Future research will utilize these models to develop advanced controls and optimize system performance for improved energy efficiency and demand flexibility.

Modeling, Variable refrigerant flow (VRF) systems,↗

Equipment List Comparing Balance of Plant Containing a Heat Pump against a Reference Electricity Generating Plant

Approximately two-thirds of U.S. energy consumption in the industrial and transportation sectors relies on fossil fuels. These sectors require high-quality heat, i.e., thermal energy at very high temperatures, for molecular transformation processes. The Integrated Energy Systems (IES) program aims to assess the economic potential of utilizing nuclear-grade heat from Advanced Reactors (ARs) to meet the high-quality heat demands. By having industrial processes (IPs) supplied with nuclear-generated heat, manufacturers could benefit from more stable and potentially lower energy costs, reducing reliance on volatile fossil fuel markets. The main outcome of the FY24 research was the thermodynamic assessment and gap analysis of steam generation for IP applications. The study completed in June 2024 demonstrated that the required steam temperatures could be achieved by integrating a heat pump into an AR power plant. After identifying the thermal demands of target IPs, multiple balance of plant configurations for the Xe-100 reactor by X-energy, incorporating a heat pump, were analyzed. Their technical feasibilities were assessed, including the design of suitable axial compressors for these applications. Comparative performance analysis showed that thermal efficiency alone is insufficient to evaluate system suitability. To address this, a new indicator (heat factor) was introduced in the report released in September 2024 to quantify the low-quality thermal power needed to produce one unit of high-quality heat for the IP. Results showed that integrating heat pumps into Rankine cycles enables higher steam temperatures, though at the expense of increased thermal energy input. This report builds upon and completes the foundational work previously undertaken. It focuses on the design of two Balance of Plant (BOP) configurations, both based on Rankine energy conversion cycles: “Case 1”, which involves electricity generation only, and “Case 2”, which combines electricity and high-temperature heat generation for industrial use. For each configuration, a comprehensive equipment list was developed, detailing all major components such as turbines, compressors, heat exchangers, pumps, and control systems. These lists will serve as the basis for future comparative cost analyses, with the goal of assessing the number and type of components required to integrate a heat pump into the Rankine cycle and to establish a heat transport system capable of delivering thermal energy from the nuclear plant to an industrial facility. Using the constitutive equations presented in the June 2024 milestone, the operating conditions of all BOP components for both “Case 1” and “Case 2” were evaluated. These parameters—such as temperature, pressure, mass flow rate, and steam quality—served as the basis for calculating the associated thermal and mechanical power flows. The net power required from the heat pump to raise the steam temperature to the target level was also determined. The thermodynamic performance of the configuration was then assessed using the heat factor metric. The key outcome of this analysis is a comparative table that presents the equipment that was used in the “Case 1” and “Case 2” configurations. This study offers a preliminary comparison of the two designs, providing insight into the impact of integrating a heat pump in terms of component requirements and thermal efficiency. This equipment list, together with the evaluated operating conditions, also serves as a foundation for the economic analyses scheduled for the current fiscal year.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Study of Shock Formation Parameters With Drive Conditions in Magnetically Accelerated Plasma Flows

We present experimental data regarding the formation of high-energy-density shocks in magnetically accelerated plasma flows using pulsed power drivers. We quantify the flow velocity and temperature of the ablated plasma using optical Thomson scattering and gated emission imaging across two different generators. We show that, regardless of the drive parameters, the plasma flows show continuous acceleration over centimeter spatial scales, in line with trends in published simulation work. When stationary targets are placed in these supersonic flows, bow-shock formation is observed at all drive parameters in a range of materials. In the higher density flow generated on the 1-MA COBRA generator at Cornell University, heating of the upstream flow ahead of the shock is observed and quantified, which is not observed at the lower density flow on the 0.2-MA Bertha driver at UC San Diego. Here, when combined with previous work on the XP generator at Cornell, we can show that these three experimental setups allow control of the effect of radiation loss and upstream absorption on the formation of the bow shock.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transient simulation of biomass combustion in a circulating fluidized bed riser

Interest in circulating fluidized bed (CFB) boilers as a power generation technology has sky-rocketed in recent years because of several advantages this technology offers over conventional boilers, such as increased gas-solid mixing, which results in higher combustion efficiency and the ability to use lower rank fuels. CFB combustors are operated at lower temperatures than conventional thermal power generation combustors, thus reducing NO x emissions, while SO 2 emissions can be conveniently controlled through the addition of Ca-based sulfur sorbents within the combustor. Herin this paper summarizes the modeling effort on a 50 kW th CFB combustor designed, built, and operated at CanmetENERGY in Ottawa, Canada. The numerical model employs the multiphase particle-in-cell (PIC) approach in the open-source Multiphase Flow with Interphase eXchanges (MFiX) Software Suite. The MFiX-PIC model parameters for the simulation are tuned against cold-flow experiments from CanmetENERGY using olivine sand as the inert bed material. It is shown that for the relatively coarse fluid meshes and large parcel sizes necessitated by the scale of the simulation, filter size dependent corrections to the drag law must be incorporated to ensure accuracy of the simulation results. The validated cold flow model is extended to simulate reacting flow with torrefied hardwood as the feedstock and to validate the combustion reaction scheme. The species concentrations at the riser outlet are compared against CanmetENERGY’s experiments and show satisfactory agreement. The simulations demonstrate the ability of MFiX-PIC to accurately capture both the physics and chemistry of a CFB combustor at bench scales, which can be further extended to pilot- and industrial-scale systems.

09 BIOMASS FUELS↗

Stability and Performance of an Undersea Kite Operating in a Turbulent Flow Field

In this paper, we examine the effects of flow disturbances resulting from turbulence on the dynamic behavior of an underwater energy-harvesting kite system that executes periodic figure-8 flight. Due to the periodic nature of the kite’s operation, we begin by assessing orbital stability using the Floquet analysis and stroboscopic intersection analysis of a Poincaré section, with the former analysis performed on a simplified “unifoil” model and the latter performed on a six-degree-of-freedom (6-DOF)/flexible tether model. With periodic stability established, a frequency-domain analysis based on a linearization about the kite’s path is used to predict the quality of flight path tracking as a function of the turbulence frequency. To validate the accuracy of these simulation-based predictions under flow disturbances, we compare the predictions of the kite’s behavior against the results of small-scale tow testing experiments performed in a controlled pool environment.

13 HYDRO ENERGY↗

Assembly Bowing Reactivity Calculation Methodology Applied to Lead Fast Reactor

Ducted assemblies bow during operation due to power and temperature gradients which can be influenced by operating flow rates. For fast spectrum cores using ducted assemblies, the bowing behavior follows that of the duct and because there are gaps between the ducts, the bowing can result in compaction or expansion of the active core. This local displacement can have a positive or negative impact and knowing the net effect during transients is important for system reactivity control. Keeping the net bowing reactivity worth low is possible with attentive placement of load pads above the active core and selecting load pad gap thicknesses that result in a desired behavior at standard operating conditions. This paper considers a Lead Fast Reactor (LFR) concept fueled by HALEU UO2 developed by Westinghouse Electric Company (WEC) and applies a workflow of Argonne-developed codes to estimate the core bowing reactivity worth. Using orifice flow rates grouped by assembly type, the net reactivity impact due to core assembly bowing for the LFR was found to be small and in line with other liquid metal fast reactors: +29/+32/+35 pcm, or about +$0.049/+$0.055/+$0.059, for BOEC/MOEC/EOEC, respectively.

bowing reactivity↗

Design and Analysis of Liquid Lithium Plasma Facing Components

In this study, liquid metal (LM) on plasma-facing components (PFCs) creates a renewable protective cover enhancing power exhaust and protecting the solid substrate. Additionally, energy confinement improvement through particle pumping can be achieved in the case of liquid lithium (LL). A new variant of PFCs was recently introduced at Princeton Plasma Physics Laboratory (PPPL) where a porous wall is used to stabilize the LM surface, while using magnetohydrodynamic (MHD) drive to push the LM flow inside the component. This arrangement allows efficient heat exhaust, and enhanced control of the LM surface temperature, leading to spatial control of evaporation and condensation of LL on the plasma interface. This feature is particularly attractive when vapor shielding is introduced to allow heat flux redistribution. This system has the advantage that as the heat flux increases, the evaporation rate will increase, while decreasing heat flux will decrease the evaporation rate of lithium, ideally creating a feedback effect which could self-regulate the amount of lithium evaporated. Analytical and numerical models for LL PFCs were developed in PPPL. To calculate the target temperature distribution for the case of evaporation from the divertor, we apply an iterative process allowing two-way coupling between the fluid-kinetic analysis of plasma using SOLPS-ITER code and the flow and heat transfer analysis of the PFC using an analytical model. In the last stage, the results are validated using computational fluid dynamics (CFD) analysis with customized version of the CFX code from ANSYS. CFX was modified at PPPL to allow MHD analysis at the high magnetic field typical for fusion applications. Results of the analysis for NSTX-U tokamak conditions will be presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of Quaternary Pumped Storage Hydropower on Frequency Response of U.S. Western Interconnection with High Renewable Penetrations

As renewable penetration increases in the United States, maintaining stability and reliability of low-inertia power grid by providing sufficient frequency control capability becomes a challenge. Advanced pumped storage hydro technologies (APSH) will be expected to play an important role for future grid as not only an energy supplier, but also as an ancillary services provider. This paper studies the impact of using quaternary pumped storage hydropower (Q-PSH), as one of the newly proposed APSH technology, to provide primary frequency response. To quantify the impact of Q-PSH on frequency response of the U.S. Western Interconnection, a user-defined dynamic model of Q-PSH is developed on the GE Positive Sequence Load Flow (PSLF) platform and is implemented in a set of detailed U.S. Western Electricity Coordination Council (WECC) planning cases in which renewable penetration levels are 20%, 40%, 60% and 80%. Simulation results show that Q-PSH can help improve frequency nadir and settling frequency comparing to the conventional PSH.

frequency response↗

Impact of Quaternary-Pumped Storage Hydropower on Frequency Response of U.S. Western Interconnection with High Renewable Penetrations: Preprint

As renewable penetration increases in the United States, maintaining stability and reliability of low-inertia power grid by providing sufficient frequency control capability becomes a challenge. Advanced pumped storage hydro technologies (APSH) will be expected to play an important role for future grid as not only an energy supplier, but also as an ancillary services provider. This paper studies the impact of using quaternary pumped storage hydropower (Q-PSH), as one of the newly proposed APSH technology, to provide primary frequency response. To quantify the impact of Q-PSH on frequency response of the U.S. Western Interconnection, a user-defined dynamic model of Q-PSH is developed on the GE Positive Sequence Load Flow (PSLF) platform and is implemented in a set of detailed U.S. Western Electricity Coordination Council (WECC) planning cases in which renewable penetration levels are 20%, 40%, 60% and 80%. Simulation results show that Q-PSH can help improve frequency nadir and settling frequency comparing to the conventional PSH.

frequency response↗

Optimal electric-distribution-grid planning considering the demand-side flexibility of thermal building systems for a test case in Singapore

The planning of district-scale electric grids, i.e., distribution grids, has traditionally relied on finding the most cost-effective design such that they are able to supply the peak loads in a district. With the advent of electric demand side flexibility (DSF), there is the opportunity to reshape peak loads such that the investment cost of the electric grid decreases in exchange for a minor increase in the operation cost. This paper formulates an optimal planning approach for the electric grid at the district scale, which incorporates the DSF from thermal building systems, e.g., heating ventilation and air-conditioning (HVAC) systems. The problem is formulated as a mixed-integer linear program (MILP) and aims at minimizing the investment cost for the grid along with the operation cost of the flexible loads. This is subjected to the fixed electricity demand and thermal comfort constraints of building occupants. To this end, linear models for the thermal comfort in the buildings and the power flow in electric grid are considered. The approach is tested on a district planning test case based in Singapore, where the results show up to 30.9 % reductions in investment cost and up to 3.7 % reduction in total annualized cost. Urban planning authorities, developers and utility companies can all benefit from the presented approach to make optimized investment decisions. For building operators, the results point to the need of adopting their control systems for DSF.

Troitzsch, Sebastian↗

SpinQuest Polarized Target System

The SpinQuest experiment at Fermilab uses a solid-state polarized ammonia target held at a magnetic field of 5 T, immersed in liquid helium-4, which is held at approximately 1K by the evaporation refrigerator. The refrigerator provides the required cooling power during the dynamic nuclear polarization (DNP) process and the high intensity interaction with the 120 GeV proton beam from the Fermilab main injector. The refrigerator was designed in compliance with the American Society of Mechanical Engineers (ASME) to operate safely at Fermilab. The high pumping capacity ($17,000 \:m^3/h$) roots stack provides the required pumping speed during DNP production data taking and a custom-made radiation hard flow control valve regulates the refrigerator temperature during the thermal equilibrium calibration measurements. The frequency of the microwave generator, an Extended Interaction Oscillator (EIO), is automated to keep the maximum polarization while the (Nuclear Magnetic Resonance) NMR system continuously measures the polarization of the target material. In this talk, an overview of the SpinQuest polarized target system will be presented as well as a brief report of recent commissioning activities and target performance during the early production runs in 2024.

Bandara, Vibodha [Colombo U.]↗