Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Polarimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Accurate determination of the electron spin polarization in magnetized iron and nickel foils for Møller polarimetry

The Møller polarimeter in Hall A at Jefferson Lab in Newport News, VA, has provided reliable measurements of electron beam polarization for the past two decades. Past experiments have typically required polarimetry at the 1% level of absolute uncertainty which the Møller polarimeter has delivered. However, the upcoming proposed experimental program including MOLLER and SoLID have stringent requirements on beam polarimetry precision at the level of 0.4% (The MOLLER Collaboration, 2014; The SoLID collaboration, 2019), requiring a systematic re-examination of all the contributing uncertainties. Møller polarimetry uses the double polarized scattering asymmetry of a polarized electron beam on a target with polarized atomic electrons. The target is a ferromagnetic material magnetized to align the spins in a given direction. In Hall A, the target is a pure iron foil aligned perpendicular to the beam and magnetized out of plane parallel or antiparallel to the beam direction. The acceptance of the detector is engineered to collect scattered electrons close to 90° in the center of mass frame where the analyzing power is a maximum (-7/9). One of the leading systematic errors comes from determination of the target foil polarization. Polarization of a magnetically saturated target foil requires knowledge of both the saturation magnetization and g', the electron g-factor which includes components from both spin and orbital angular momentum from which the spin fraction of magnetization is determined. Target foil polarization has been previously addressed in a 1997 publication “A precise target for Møller polarimetry” by de Bever et al. (1997) at a level of precision sufficient for experiments up to this point. Several shortcomings with the previous published value require revisiting the result prior to MOLLER. Here, we utilize the existing world data to provide a best estimate for target polarization for both nickel and iron foils including uncertainties in magnetization, high-field and temperature dependence, and fractional contribution to magnetization from orbital effects. We determine the foil electron spin polarization at 294 K to be 0.08020 ± 0.00018 (@4 T applied field) for iron and 0.018845+/-0.000053 (@2 T applied field) for nickel. Finally, we conclude with a brief discussion of additional systematic uncertainties to Møller polarimetry using this technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First measurement of polarisation transfer $C$$^{n}_{x'}$ in deuteron photodisintegration

A first measurement of the polarisation transfer from a circularly-polarised photon to the final state neutron ($C$$^{n}_{x'}$) in deuterium photodisintegration has been carried out. This quantity is determined over the photon energy range 370 – 700 MeV and for neutron centre-of-mass breakup angles ~ 45 – 120°. The polarisation of the final state neutrons was determined by an ancillary large-acceptance nucleon polarimeter, surrounding a cryogenic liquid deuterium target within the Crystal Ball detector at MAMI. The polarimeter characterised (n, p) charge exchange of the ejected neutrons to determine their polarisation. The new $C$$^{n}_{x'}$ data are also compared to a theoretical model based on nucleonic and nucleon resonance degrees of freedom constrained by the current world-database of deuterium photodisintegration measurements. Structures in $C$$^{n}_{x'}$ observed in the region of the d*(2380) could not be explained by conventional models of deuteron photodisintegration.

79 ASTRONOMY AND ASTROPHYSICS↗

A high-efficiency spin-resolved photoemission spectrometer combining time-of-flight spectroscopy with exchange-scattering polarimetry

We describe a spin-resolved electron spectrometer capable of uniquely efficient and high energy resolution measurements. Spin analysis is obtained through polarimetry based on low-energy exchange scattering from a ferromagnetic thin-film target. This approach can achieve a similar analyzing power (Sherman function) as state-of-the-art Mott scattering polarimeters, but with as much as 100 times improved efficiency due to increased reflectivity. Performance is further enhanced by integrating the polarimeter into a time-of-flight (TOF) based energy analysis scheme with a precise and flexible electrostatic lens system. The parallel acquisition of a range of electron kinetic energies afforded by the TOF approach results in an order of magnitude (or more) increase in efficiency compared to hemispherical analyzers. The lens system additionally features a 90 degrees bandpass filter, which by removing unwanted parts of the photoelectron distribution allows the TOF technique to be performed at low electron drift energy and high energy resolution within a wide range of experimental parameters. The spectrometer is ideally suited for high-resolution spin- and angle-resolved photoemission spectroscopy (spin-ARPES), and initial results are shown. The TOF approach makes the spectrometer especially ideal for time-resolved spin-ARPES experiments.

36 MATERIALS SCIENCE↗

Correlation polarimetry for broadband magnetic fluctuation measurements

Correlation techniques have been successfully utilized for plasma diagnostics like electron cyclotron emission to reduce measurement noise. Herein we present the first application of such a technique to Faraday-effect polarimetry measurements on the Madison Symmetric Torus (MST). The MST far infrared (FIR) interferometer-polarimeter diagnostic utilizes 11 vertical chords with a chord separation of 7-8 cm and a heterodyne detection system for fluctuation measurements up to several hundred kHz. The planar-diode mixers viewing each chord represent independent noise sources; modifying the optical setup so that two different mixers view the same chord allows cross correlation between the two independent signals to reduce the noise floor in fluctuation measurements. In this manner, the noise floor in both interferometry and polarimetry measurements in reversed-field pinch discharges has been reduced by a factor of 20-30. The correlation polarimeter provides a sensitive measurement of broadband magnetic fluctuations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Motional Stark effect imaging first results on the DIII-D tokamak

A motional Stark effect (MSE) imaging diagnostic was benchmarked against existing conventional MSE polarimeters on the DIII-D tokamak and delivered new capabilities for measuring the magnetic pitch angle from 2 neutral beams and on the high field side of DIII-D. Line integration across flux surfaces was considerable for the radial view utilised; yet, the imaging MSE measurements from both beams were self-consistent and in close agreement with conventional MSE measurements. The ferroelectric liquid crystal waveplate used in the imaging polarimeter was discovered to have spatially non-uniform retardance; thus, it is required for the calibration source to replicate the ray paths of the neutral beam emission through the optical system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BAYESIAN INFERENCE OF SOLAR AND STELLAR MAGNETIC FIELDS IN THE WEAK-FIELD APPROXIMATION

The weak-field approximation is one of the simplest models that allows us to relate the observed polarization induced by the Zeeman effect with the magnetic field vector present on the plasma of interest. It is usually applied for diagnosing magnetic fields in the solar and stellar atmospheres. A fully Bayesian approach to the inference of magnetic properties in unresolved structures is presented. The analytical expression for the marginal posterior distribution is obtained, from which we can obtain statistically relevant information about the model parameters. The role of a priori information is discussed and a hierarchical procedure is presented that gives robust results that are almost insensitive to the precise election of the prior. The strength of the formalism is demonstrated through an application to IMaX data. Bayesian methods can optimally exploit data from filter polarimeters given the scarcity of spectral information as compared with spectro-polarimeters. The effect of noise and how it degrades our ability to extract information from the Stokes profiles is analyzed in detail.

79 ASTRONOMY AND ASTROPHYSICS↗

BICEP2/KECK ARRAY V: MEASUREMENTS OF B-MODE POLARIZATION AT DEGREE ANGULAR SCALES AND 150 GHz BY THE KECK ARRAY

The Keck Array is a system of cosmic microwave background polarimeters, each similar to the Bicep2 experiment. In this paper we report results from the 2012 to 2013 observing seasons, during which the Keck Array consisted of five receivers all operating in the same (150 GHz) frequency band and observing field as Bicep2. We again find an excess of B-mode power over the lensed-ΛCDM expectation of >5σ in the range 30 < ℓ < 150 and confirm that this is not due to systematics using jackknife tests and simulations based on detailed calibration measurements. In map difference and spectral difference tests these new data are shown to be consistent with Bicep2. Finally, we combine the maps from the two experiments to produce final Q and U maps which have a depth of 57 nK deg (3.4 μK arcmin) over an effective area of 400 deg{sup 2} for an equivalent survey weight of 250,000 μK{sup −2}. The final BB band powers have noise uncertainty a factor of 2.3 times better than the previous results, and a significance of detection of excess power of >6σ.

79 ASTRONOMY AND ASTROPHYSICS↗

The proton form factor measurements at Jefferson Lab, past and future

Use of the double-polarization technique to obtain the elastic nucleon form factors has resulted in a dramatic improvement of the quality of two of the four nucleon electromagnetic form factors, G{sub Ep} and G{sub En}. It has also changed our understanding of the proton structure, having resulted in a distinctly different Q{sup 2}-dependence for both G{sub Ep} and G{sub Mp}, contradicting the prevailing wisdom of the 1990’s based on cross section measurements, namely that G{sub Ep} and G{sub Mp} obey a “scaling” relation μG{sub Ep} ∼ G{sub Mp}. A related consequence of the faster decrease of G{sub Ep} revealed by the Jefferson Lab (JLab) polarization results was the disappearance of the early scaling F{sub 2}/F{sub 1} ∼ 1/Q{sup 2} predicted by perturbative QCD. In three experiments, GEp(1), GEp(2) and GEp(3), in Halls A and C at JLab, the ratio of the proton’s electromagnetic elastic form factors, G{sub Ep}/G{sub Mp}, was measured up to four momentum transfer Q{sup 2} of 8.5 GeV{sup 2} with high precision, using the recoil polarization technique. The initial discovery that the proton form factor ratio measured in these three experiments decreases approximately linearly with four-momentum transfer, Q{sup 2}, for values above ∼ 1 GeV{sup 2}, was modified by the GEp(3) results, which suggests a slowing down of this decrease. There is an approved experiment, GEp(5), to continue these measurements to 15 GeV{sup 2}. A dedicated experimental setup, the super bigbite spectrometer (SBS), will be built for this purpose. It will be equipped with a new focal plane polarimeter to measure the polarization of the recoil protons. In this presentation, I will review the status of the proton elastic electromagnetic form factors, mention succinctly a number of theoretical approaches to describe results and show some features required for the future GEp(5) experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precise polarization measurements via detection of compton scattered electrons

The Qweak experiment at Jefferson Lab aims to make a 4% measurement of the parity-violating asymmetry in elastic scattering at very low Q{sup 2} of a longitudinally polarized electron beam off a proton target. One of the dominant experimental systematic uncertainties in Qweak will result from determining the beam polarization. A new Compton polarimeter was installed in the fall of 2010 to provide a non-invasive and continuous monitoring of the electron beam polarization in Hall C at Jefferson Lab. The Compton-scattered electrons are detected in four planes of diamond micro-strip detectors. We have achieved the design goals of <1% statistical uncertainty per hour and expect to achieve <1% systematic uncertainty.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hadron Polarimetry for the Electron-Ion Collider

The Electron-Ion Collider (EIC) will be the first collider to use both polarized electron beams and polarized proton and light ion beams. It will therefore offer unique opportunities to study the structure of nucleons and to answer fundamental questions in QCD. The uncertainties on the polarization measurement translate directly into the uncertainties of final physics observables. Hence, a precise measurement of the hadron beam polarization and a good control of systematic uncertainties are critical for the success of the spin program at the EIC. Contrary to the case of electron beam polarimetry, which uses physical processes derived from first principles that allow a high precision extraction of the electron beam polarization, for hadron beams no such process is available. The currently best used methods rely on the process of elastic scattering in the Coulomb-Nuclear Interference (CNI) region, for which there are only effective models available. The experience from RHIC, the only existing polarized proton collider, will be detailed and the challenges of the measurements at the EIC will be addressed. In particular, measurements of the present RHIC polarimeters and simulations of the future EIC polarimeters will be presented.

Nunes, Ana Sofia↗

Characterizing Aerosol Distributions and Optical Properties Using the NASA Langley High Spectral Resolution Lidar

The objective of this project was to provide vertically and horizontally resolved data on aerosol optical properties to assess and ultimately improve how models represent these aerosol properties and their impacts on atmospheric radiation. The approach was to deploy the NASA Langley Airborne High Spectral Resolution Lidar (HSRL) and other synergistic remote sensors on DOE Atmospheric Science Research (ASR) sponsored airborne field campaigns and synergistic field campaigns sponsored by other agencies to remotely measure aerosol backscattering, extinction, and optical thickness profiles. Synergistic sensors included a nadir-viewing digital camera for context imagery, and, later in the project, the NASA Goddard Institute for Space Studies (GISS) Research Scanning Polarimeter (RSP). The information from the remote sensing instruments was used to map the horizontal and vertical distribution of aerosol properties and type. The retrieved lidar parameters include profiles of aerosol extinction, backscatter, depolarization, and optical depth. Products produced in subsequent analyses included aerosol mixed layer height, aerosol type, and the partition of aerosol optical depth by type. The lidar products provided vertical context for in situ and remote sensing measurements from other airborne and ground-based platforms employed in the field campaigns and was used to assess the predictions of transport models. Also, the measurements provide a data base for future evaluation of techniques to combine active (lidar) and passive (polarimeter) measurements in advanced retrieval schemes to remotely characterize aerosol microphysical properties. The project was initiated as a 3-year project starting 1 January 2005. It was later awarded continuation funding for another 3 years (i.e., through 31 December 2010) followed by a 1-year no-cost extension (through 31 December 2011). This project supported logistical and flight costs of the NASA sensors on a dedicated aircraft, the subsequent analysis and archival of the data, and the presentation of results in conferences, workshops, and publications. DOE ASR field campaigns supported under this project included: • MAX-Mex /MILAGRO (2006), • TexAQS 2006/GoMACCS (2006), • CHAPS (2007), • RACORO (2009), and • CARE/CalNex (2010). In addition, data acquired on HSRL airborne field campaigns sponsored by other agencies were used extensively to fulfill the science objectives of this project and the data acquired have been made available to other DOE ASR investigators upon request.

99 GENERAL AND MISCELLANEOUS↗

Polarimetry at RHIC: RHIC polarized beam in Run 2011

In 2011 Run polarized proton beam collisions of a total energy Sqrt S=500 GeV and peak luminosity up to 1.6*10^32 cm -2 sec -1 was delivered to experiments for intermediate boson W production studies with the longitudinally polarized beams. The average beam polarization of a 48% was measured with the H-jet polarimeter. Apparently, there are no polarization losses during acceleration to 100 GeV energy, where a 55-60% polarization was measured in Run 2009. Polarization losses at further acceleration to 250 GeV are caused by the presence depolarizing resonances. As a result, significant polarization profiles of the beams are also generated. Polarization profiles were measured by the p-Carbon CNI polarimeters in the scanning mode of operation. Polarized beam luminosity is weighted by the polarization profiles and “effective” polarization, as seen in collisions was about 53% in Run 2011.

43 PARTICLE ACCELERATORS↗

PRECISION MØLLER POLARIMETRY AND APPLICATIONS AT JEFFERSON LABORATORY

Jefferson Lab's cutting-edge parity-violating electron scattering program has increasingly stringent requirements for systematic errors. Beam polarimetry is often one of the dominant systematic errors in these experiments. A new Møller Polarimeter in Hall A of Jefferson Lab (JLab) was installed in 2015 and has taken first measurements for a polarized scattering experiment. Upcoming parity violation experiments in Hall A include CREX, PREX-II, MOLLER and SOLID with the latter two requiring <0.5% precision on beam polarization measurements, a precision which has not been achieved to date. The polarimeter measures the Møller scattering rates of the polarized electron beam incident upon an iron target placed in a saturating magnetic field. The spectrometer consists of four quadrupoles and one momentum selection dipole. The detector is designed to measure the scattered and knock out target electrons in coincidence. Beam polarization is extracted by constructing an asymmetry from the scattering rates when the incident electron spin is parallel and antiparallel to the target electron spin. The largest systematic errors associated with Møller polarimetry comes from the precision that the target polarization and the detector acceptance is known will be discussed. Other errors including the Levchuk effect, beam stability, and target heating will be addressed.

Henry, William↗

A New Spin on Photoemission Spectroscopy

The electronic spin degree of freedom is of general fundamental importance to all matter. Understanding its complex roles and behavior in the solid state, particularly in highly correlated and magnetic materials, has grown increasingly desirable as technology demands advanced devices and materials based on ever stricter comprehension and control of the electron spin. However, direct and efficient spin dependent probes of electronic structure are currently lacking. Angle Resolved Photoemission Spectroscopy (ARPES) has become one of the most successful experimental tools for elucidating solid state electronic structures, bolstered by-continual breakthroughs in efficient instrumentation. In contrast, spin-resolved photoemission spectroscopy has lagged behind due to a lack of similar instrumental advances. The power of photoemission spectroscopy and the pertinence of electronic spin in the current research climate combine to make breakthroughs in Spin and Angle Resolved Photoemission Spectroscopy (SARPES) a high priority . This thesis details the development of a unique instrument for efficient SARPES and represents a radical departure from conventional methods. A custom designed spin polarimeter based on low energy exchange scattering is developed, with projected efficiency gains of two orders of magnitude over current state-of-the-art polarimeters. For energy analysis, the popular hemispherical analyzer is eschewed for a custom Time-of-Flight (TOF) analyzer offering an additional order of magnitude gain in efficiency. The combined instrument signifies the breakthrough needed to perform the high resolution SARPES experiments necessary for untangling the complex spin-dependent electronic structures central to today's condensed matter physics.

36 MATERIALS SCIENCE↗

Electron polarimetry at EIC

The Electron-Ion Collider will be the first collider to use both polarized electron beams and po&#x2;larized protons and light ions . This will offer unique opportunities to study the structure of pro&#x2;tons and nuclei and answer fundamental questions in QCD. The uncertainties on the polarization measurement translate directly into the uncertainties of final physics observables. Hence, a pre&#x2;cise measurement of the hadron beam polarization and a good control of the uncertainties are critical for the success of the spin program at the EIC. The requirements for beam polarimetry are non-destructive with uncertainty less than 1%. At the Electron Storage Ring (ESR) and the Rapid Cycling Synchrotron (RCS), the electron beam polarization will be measured using well&#x2;established Compton polarimetry techniques. However, the EIC Compton polarimeter will face unique challenges, demanding further developments. A Mott polarimeter will also be employed at the source for initial polarization measurements. Both longitudinal and transverse polarization will be measured, with the capability to monitor polarization on a bunch-by-bunch basis. Achieving these precise measurements will be critical to controlling systematic uncertainties and ensuring the overall success of the EIC’s physics objectives.

Zhang, Zhengqiao (ORCID:0009000742521735)↗

Point source polarimetry with the Gemini Planet Imager: Sensitivity characterization with T5.5 dwarf companion HD 19467 B

Detecting polarized light from self-luminous exoplanets has the potential to provide key information about rotation, surface gravity, cloud grain size, and cloud coverage. While field brown dwarfs with detected polarized emission are common, no exoplanet or substellar companion has yet been detected in polarized light. With the advent of high contrast imaging spectro-polarimeters such as GPI and SPHERE, such a detection may now be possible with careful treatment of instrumental polarization. In this paper, we present 28 minutes of H-band GPI polarimetric observations of the benchmark T5.5 companion HD 19467 B. We detect no polarization signal from the target, and place an upper limit on the degree of linear polarization of p{sub CL99.73%}⩽2.4%. We discuss our results in the context of T dwarf cloud models and photometric variability.

79 ASTRONOMY AND ASTROPHYSICS↗

Stellar X-ray polarimetry on OSO-1

The importance of stellar X-ray polarimetry is reviewed. A graphite crystal polarimeter sensitive near 2.6 and 5.2 keV which was designed for the OSO-1 satellite is described. The instrument's predicted performance for many stellar X-ray sources is presented, and the fundamental questions that can be resolved with the OSO-1 polarimeter are considered. The sensitivity of the instrument is such that, during an observation time of 24 hours, the polarization of the Crab nebula can be measured with an accuracy of 0.6 percent.

Landecker, P. B.↗

Multidisciplinary research in the space sciences. Scope B: Experimental X-ray astronomy

A research program to design and develop instruments suitable for rocket-borne X-ray astronomy experiments is discussed. Successful designs that were implemented are summarized. The designs include the following: (1) a large area modular X-ray focusing system, (2) incoherent scattering polarimeters, (3) Bragg crystal spectrometers and polarimeters, and (4) a focusing collector for long wavelength. The applications of these instruments to the observation of X-ray sources in rocket-borne experiments are analyzed.

Novick, R.↗