Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Langmuir probe diagnostic suite in the C-2 field-reversed configuration

Several in situ probes have been designed and implemented into the diagnostic array of the C-2 field-reversed configuration (FRC) at Tri Alpha Energy [M. Tuszewski et al. (the TAE Team), Phys. Rev. Lett. 108, 255008 (2012)]. The probes are all variations on the traditional Langmuir probe. They include linear arrays of triple probes, linear arrays of single-tipped swept probes, a multi-faced Gundestrup probe, and an ion-sensitive probe. The probes vary from 5 to 7 mm diameter in size to minimize plasma perturbations. They also have boron nitride outer casings that prevent unwanted electrical breakdown and reduce the introduction of impurities. The probes are mounted on motorized linear-actuators allowing for programmatic scans of the various plasma parameters over the course of several shots. Each probe has a custom set of electronics that allows for measurement of the desired signals. High frequency ( > 5MHz) analog optical-isolators ensure that plasma parameters can be measured at sub-microsecond time scales while providing electrical isolation between machine and data acquisition systems. With these probes time-resolved plasma parameters (temperature, density, spatial potential, flow, and electric field) can be directly/locally measured in the FRC jet and edge/scrape-off layer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The role of probe oxide in local surface conductivity measurements

Local probe methods can be used to measure nanoscale surface conductivity, but some techniques including nanoscale four point probe rely on at least two of the probes forming the same low resistivity non-rectifying contact to the sample. Here, the role of probe shank oxide has been examined by carrying out contact and non-contact I V measurements on GaAs when the probe oxide has been controllably reduced, both experimentally and in simulation. In contact, the barrier height is pinned but the barrier shape changes with probe shank oxide dimensions. In non-contact measurements, the oxide modifies the electrostatic interaction inducing a quantum dot that alters the tunneling behavior. For both, the contact resistance change is dependent on polarity, which violates the assumption required for four point probe to remove probe contact resistance from the measured conductivity. This has implications for all nanoscale surface probe measurements and macroscopic four point probe, both in air and vacuum, where the role of probe oxide contamination is not well understood.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Planetary Probe Entry Models for Concurrent and Integrated Interplanetary Mission Design

There are many prospective mission opportunities involving atmospheric entry probes. The Planetary Science Deep Space SmallSat Studies (PSDS3) re-cently selected probe missions to Venus, Mars, and the outer planets as part of the 10 selected studies. Two of the six themes in the most recent New Fron-tiers call were a Saturn probe and a Venus in situ explorer. The 2013-2022 Planetary Science Decadal Survey includes probe missions at Venus, Mars, Saturn, Titan, Uranus, and Neptune. Across mission destinations and mission classes there is growing interest in planetary probes. While interplanetary trajectory specialists may like to use a broad sweep of low-fidelity solutions to find a wide array of trajectory options, probe specialists typically start off with mid- to high-fidelity point designs for the entry probe since the equations of motion for atmospheric probes require numerical integration and are so directly linked with some of the probe's subsystem design. Cur-rently, there are no alternatives to this design ap-proach as there are no tools capable of automatical-ly and concurrently designing interplanetary and atmospheric trajectories. Unfortunately, this makes us reliant on point designs in the early stages of the mission design process. The reliance on point de-signs for atmospheric probes hinders the flexibility of the design, making the design process cumber-some and restricting decision-making down the road. The research presented here addresses this problem by providing low-fidelity models for the automated, rapid design of atmospheric trajectories and probe's models which may be solved concur-rently with the interplanetary trajectory.

atmospheric probes↗

Pioneer Venus probe models instrumented prop tests

Models of both the small and large Pioneer Venus probes were dropped from a helicopter to simulate the conditions of Mach and Reynolds numbers to be encountered by the probes upon entry into the Venus atmosphere. The models were dropped at an average Mach number of .10 and at an average Reynolds number of 2.84 million for the small probe and 2.90 million for the large probe. After the large amplitude launching oscillations were damped, the small probe oscillations in angle of attack and in sideslip were generally less than 2 degrees. The large probe oscillations were generally less than 10 degrees. Both exhibited distinct frequencies. The motion of the small probe in a place perpendicular to the z axis was random while the large probe rotated (corkscrewed) at 1.1 cycles per second about the z axis. The average drag coefficients of the probe models were .714 for the small probe and .663 for the large probe.

Muirhead, V. U.↗

Seven hole probe measurement of leading edge vortex flows

This paper discusses the use of a seven-hole probe on measurements of leading edge vortices of highly sweep delta wing planforms. Intrusive probe data taken with the pressure probe were compared with nonintrusive measurements made with laser Doppler anemometry system. In addition to probe size, the natural position of breakdown and the sweep angle of the wing are also factors in determining sensitivity of the flow to probe interference. At low angles of attach vortex breakdown does not occur in the vicinity of the model and the seven hole probe was found to yield reasonably accurate measurements. When the angle of attack of the model was increased so that vortex breakdown was near the trailing edge, introducing the probe over the wing would cause the breakdown position to move ahead of the probe. However, when breakdown naturally occurred ahead of the mid-chord of the wing the vortices were found to be less sensitive to a probe placed behind the breakdown point. Vortex breakdown on a lower swept wing is found to be more sensitive to interference. Near the breakdown region, seven hole probe measurement is less accurate due to a combination of probe interference and flow reversal.

Payne, F. M.↗

Novel, Miniature Multi-Hole Probes and High-Accuracy Calibration Algorithms for their use in Compressible Flowfields

Two new calibration algorithms were developed for the calibration of non-nulling multi-hole probes in compressible, subsonic flowfields. The reduction algorithms are robust and able to reduce data from any multi-hole probe inserted into any subsonic flowfield to generate very accurate predictions of the velocity vector, flow direction, total pressure and static pressure. One of the algorithms PROBENET is based on the theory of neural networks, while the other is of a more conventional nature (polynomial approximation technique) and introduces a novel idea of local least-squares fits. Both algorithms have been developed to complete, user-friendly software packages. New technology was developed for the fabrication of miniature multi-hole probes, with probe tip diameters all the way down to 0.035". Several miniature 5- and 7-hole probes, with different probe tip geometries (hemispherical, conical, faceted) and different overall shapes (straight, cobra, elbow probes) were fabricated, calibrated and tested. Emphasis was placed on the development of four stainless-steel conical 7-hole probes, 1/16" in diameter calibrated at NASA Langley for the entire subsonic regime. The developed calibration algorithms were extensively tested with these probes demonstrating excellent prediction capabilities. The probes were used in the "trap wing" wind tunnel tests in the 14'x22' wind tunnel at NASA Langley, providing valuable information on the flowfield over the wing. This report is organized in the following fashion. It consists of a "Technical Achievements" section that summarizes the major achievements, followed by an assembly of journal articles that were produced from this project and ends with two manuals for the two probe calibration algorithms developed.

Rediniotis, Othon K.↗

Understanding of Jupiter's Atmosphere After the Galileo Probe Entry

Instruments on the Galileo probe measured composition, cloud properties, thermal structure. winds, radiative energy balance, and electrical properties of the Jovian atmosphere. As expected the probe results confirm some expectations about Jupiter's atmosphere, refute others, and raise new questions which still remain unanswered. This talk will concentrate on those aspects of the probe observations which either raised new questions or remain unresolved. The Galileo probe observations of composition and clouds provided some of the biggest surprises of the mission. Helium abundance measured by the probe differed significantly from the remote sensing derivations from Voyager. discrepancy between the Voyager helium abundance determinations for Jupiter and the Galileo probe value have now led to a considerably increased helium determination for Saturn. Global abundance of N in the form of ammonia was observed to be supersolar by approximately the same factor as carbon, in contrast to expectations that C/N would be significantly larger than solar. This has implications for the formation and evolution of Jupiter. The cloud structure was not what was generally anticipated, even though most previous remote sensing results below the uppermost cloud referred to 5 micron hot spots, local regions with reduced cloud opacity. The Galileo probe descended in one of these hot spots. Only a tenuous, presumed ammonium hydrosulfide, cloud was detected, and no significant water cloud or super-solar water abundance was measured. The mixing ratios as a function of depth for the condensibles ammonia, hydrogen sulfide, and water, exhibited no apparent correlation with either condensation levels or with each other, an observation that is still a puzzle, although there are now dynamical models of hot spots which show promise in being able to explain such behavior. Probe tracked zonal winds show that wind magnitude increases with depth to pressures of about 4 bars, with the winds extending to at least as deep as the probe made measurements, 22 bars. Models of hot spot dynamics raise the possibility that the variation with depth of the probe measured zonal winds between 0.4 and 4 bars reflect the dynamics of the hot spot rather than the global wind pattern. Galileo upper atmosphere measurements established that there is a sharp temperature rise with altitude between about 350 and 800 km above the 1 bar pressure level, with the upper atmosphere reaching, temperatures near 900 K. The energy sources for this upper atmosphere heating are not clearly established, but various mechanisms have been proposed. These and other aspects of the Galileo probe data will be discussed.

Young, Richard E.↗

Understanding of Jupiter's Atmosphere after the Galileo Probe Entry

Instruments on the Galileo probe measured composition, cloud properties, thermal structure, winds, radiative energy balance, and electrical properties of the Jovian atmosphere. As expected the probe results confirm some expectations about Jupiter's atmosphere, refute others, and raise new questions which still remain unanswered. This talk will concentrate on those aspects of the probe observations which either raised new questions or remain unresolved. The Galileo probe observations of composition and clouds provided some of the biggest surprises of the mission. Helium abundance measured by the probe differed significantly from the remote sensing derivations from Voyager. Discrepancy between the Voyager helium abundance determinations for Jupiter and the Galileo probe value have now led to a considerably increased helium determination for Saturn. Global abundance of N in the form of ammonia was observed to be super-solar by approximately the same factor as carbon, in contrast to expectations that C/N would be significantly larger than solar. This has implications for the formation and evolution of Jupiter. The cloud structure was not what was generally anticipated, even though most previous remote sensing results below the uppermost cloud referred to 5 micron hot spots, local regions with reduced cloud opacity. The Galileo probe descended in one of these hot spots. Only a tenuous, presumed ammomium hydrosulfide, cloud was detected, and no significant water cloud or super-solar water abundance was measured. The mixing ratios as a function of depth for the condensibles ammonia, hydrogen sulfide, and water, exhibited no apparent correlation with either condensation levels or with each other, an observation that is still a puzzle, although there are now dynamical models of hot spots which show promise in being able to explain such behavior. Probe tracked zonal winds show that wind magnitude increases with depth to pressures of about 4 bars, with the winds extending to at least as deep as the probe made measurements, 22 bars. Models of hot spot dynamics raise the possibility that the variation with depth of the probe measured zonal winds between 0.4 and 4 bars reflect the dynamics of the hot spot rather than the global wind pattern. Galileo upper atmosphere measurements established that there is a sharp temperature rise with altitude between about 350 and 800 km above the 1 bar pressure level, with the upper atmosphere reaching temperatures near 900 K. The energy sources for this upper atmosphere heating are not clearly established, but various mechanisms have been proposed. These and other aspects of the Galileo probe data will be discussed.

Fonda, Mark↗

Application of a Split-Fiber Probe to Velocity Measurement in the NASA Research Compressor

A split-fiber probe was used to acquire unsteady data in a research compressor. The probe has two thin films deposited on a quartz cylinder 200 microns in diameter. A split-fiber probe allows simultaneous measurement of velocity magnitude and direction in a plane that is perpendicular to the sensing cylinder, because it has its circumference divided into two independent parts. Local heat transfer considerations indicated that the probe direction characteristic is linear in the range of flow incidence angles of +/- 35. Calibration tests confirmed this assumption. Of course, the velocity characteristic is nonlinear as is typical in thermal anemometry. The probe was used extensively in the NASA Glenn Research Center (GRC) low-speed, multistage axial compressor, and worked reliably during a test program of several months duration. The velocity and direction characteristics of the probe showed only minute changes during the entire test program. An algorithm was developed to decompose the probe signals into velocity magnitude and velocity direction. The averaged unsteady data were compared with data acquired by pneumatic probes. An overall excellent agreement between the averaged data acquired by a split-fiber probe and a pneumatic probe boosts confidence in the reliability of the unsteady content of the split-fiber probe data. To investigate the features of unsteady data, two methods were used: ensemble averaging and frequency analysis. The velocity distribution in a rotor blade passage was retrieved using the ensemble averaging method. Frequencies of excitation forces that may contribute to high cycle fatigue problems were identified by applying a fast Fourier transform to the absolute velocity data.

Lepicovsky, Jan↗

Rigid spine reinforced polymer microelectrode array probe and method of fabrication

A rigid spine-reinforced microelectrode array probe and fabrication method. The probe includes a flexible elongated probe body with conductive lines enclosed within a polymeric material. The conductive lines connect microelectrodes found near an insertion end of the probe to respective leads at a connector end of the probe. The probe also includes a rigid spine, such as made from titanium, fixedly attached to the probe body to structurally reinforce the probe body and enable the typically flexible probe body to penetrate and be inserted into tissue, such as neural tissue. By attaching or otherwise fabricating the rigid spine to connect to only an insertion section of the probe body, an integrally connected cable section of the probe body may remain flexible.

47 OTHER INSTRUMENTATION↗

Prevention of nanoscale wear in atomic force microscopy through the use of monolithic ultrananocrystaline diamond probes.

Nanoscale wear is a key limitation of conventional atomic force microscopy (AFM) probes that results in decreased resolution, accuracy, and reproducibility in probe-based imaging, writing, measurement, and nanomanufacturing applications. Diamond is potentially an ideal probe material due to its unrivaled hardness and stiffness, its low friction and wear, and its chemical inertness. However, the manufacture of monolithic diamond probes with consistently shaped small-radius tips has not been previously achieved. The first wafer-level fabrication of monolithic ultrananocrystalline diamond (UNCD) probes with <5-nm grain sizes and smooth tips with radii of 30-40 nm is reported, which are obtained through a combination of microfabrication and hot-filament chemical vapor deposition. Their nanoscale wear resistance under contact-mode scanning conditions is compared with that of conventional silicon nitride (SiN{sub x}) probes of similar geometry at two different relative humidity levels ({approx}15 and {approx}70%). While SiN{sub x} probes exhibit significant wear that further increases with humidity, UNCD probes show little measurable wear. The only significant degradation of the UNCD probes observed in one case is associated with removal of the initial seed layer of the UNCD film. The results show the potential of a new material for AFM probes and demonstrate a systematic approach to studying wear at the nanoscale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal and structural analysis of a new WEST reciprocating probe head with Titanium-Zirconium-Molybdenum armour material

The Tore Supra tokamak was transformed into an X-point divertor fusion device in the frame of the WEST (W-for tungsten-Environment in Steady-state Tokamak) project, launched in support of the ITER tungsten divertor strategy. WEST began operation in 2017. A new reciprocating probe head, equipped with a Titanium-Zirconium-Molybdenum (TZM) heat shield, was recently built and operated on WEST during the C9 Campaign in early 2024. TZM was chosen as armour material for its very good mechanical properties between 700 °C and 1400 °C. This material was already extensively used for probe heads and other plasma facing components on the Alcator C-Mod tokamak. Here, this paper presents the design of the new WEST probe head. It is equipped with tungsten filaments that can be heated to emit electrons and provide a direct measurement of the plasma potential in the scrape-off layer, and it is also equipped with a pair of Langmuir probes. The probe plunges vertically into the plasma, reaches its maximum dive depth, then returns to its protected resting position in about 0.25 s. Thermal loads are calculated using as input the thermal properties of TZM and radial profiles of the heat flux measured in the past by other reciprocating probes, and scaled upwards to the expected heat loads in the WEST scrape-off layer. An analytical estimation of Electromagnetic (EM) loads will also be presented, as well as a thermal and structural analysis of the probe for 15 cycles at maximum plunge depth. The probe is observed by an infrared camera. Comparisons between the heat flux deduced by the Langmuir probe and the infrared radiance of the probe housing during plasma exposure are finally presented.

Diagnostic↗

Laser-heated emissive plasma probe

Emissive probes are standard tools in laboratory plasmas for the direct determination of the plasma potential. Usually they consist of a loop of refractory wire heated by an electric current until sufficient electron emission. Recently emissive probes were used also for measuring the radial fluctuation-induced particle flux and other essential parameters of edge turbulence in magnetized toroidal hot plasmas [R. Schrittwieser et al., Plasma Phys. Controlled Fusion 50, 055004 (2008)]. We have developed and investigated various types of emissive probes, which were heated by a focused infrared laser beam. Such a probe has several advantages: higher probe temperature without evaporation or melting and thus higher emissivity and longer lifetime, no deformation of the probe in a magnetic field, no potential drop along the probe wire, and faster time response. The probes are heated by an infrared diode laser with 808 nm wavelength and an output power up to 50 W. One probe was mounted together with the lens system on a radially movable probe shaft, and radial profiles of the plasma potential and of its oscillations were measured in a linear helicon discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sub-diffusion and trapped dynamics of neutral and charged probes in DNA-protein coacervates

The physical mechanism leading to the formation of large intermolecular DNA-protein complexes has been studied. Our study aims to explain the occurrence of fast coacervation dynamics at the charge neutralization point, followed by the appearance of smaller complexes and slower coacervation dynamics as the complex experiences overcharging. Furthermore, the electrostatic potential and probe mobility was investigated to mimic the transport of DNA / DNA-protein complex in a DNA-protein complex coacervate medium [N. Arfin and H. B. Bohidar, J. Phys. Chem. B 116, 13192 (2012)] by assigning neutral, negative, or positive charge to the probe particle. The mobility of the neutral probe was maximal at low matrix concentrations and showed random walk behavior, while its mobility ceased at the jamming concentration of c = 0.6, showing sub-diffusion and trapped dynamics. The positively charged probe showed sub-diffusive random walk followed by trapped dynamics, while the negatively charged probe showed trapping with occasional hopping dynamics at much lower concentrations. Sub-diffusion of the probe was observed in all cases under consideration, where the electrostatic interaction was used exclusively as the dominant force involved in the dynamics. For neutral and positive probes, the mean square displacement 〈R{sup 2}〉 exhibits a scaling with time as 〈R{sup 2}〉 ∼ t{sup α}, distinguishing random walk and trapped dynamics at α = 0.64 ± 0.04 at c = 0.12 and c = 0.6, respectively. In addition, the same scaling factors with the exponent β = 0.64 ± 0.04 can be used to distinguish random walk and trapped dynamics for the neutral and positive probes using the relation between the number of distinct sites visited by the probe, S(t), which follows the scaling, S(t) ∼ t{sup β}/ln (t). Our results established the occurrence of a hierarchy of diffusion dynamics experienced by a probe in a dense medium that is either charged or neutral.

36 MATERIALS SCIENCE↗

Direct Vlasov simulations of electron-attracting cylindrical Langmuir probes in flowing plasmas

Current collection by positively polarized cylindrical Langmuir probes immersed in flowing plasmas is analyzed using a non-stationary direct Vlasov-Poisson code. A detailed description of plasma density spatial structure as a function of the probe-to-plasma relative velocity U is presented. Within the considered parametric domain, the well-known electron density maximum close to the probe is weakly affected by U. However, in the probe wake side, the electron density minimum becomes deeper as U increases and a rarified plasma region appears. Sheath radius is larger at the wake than at the front side. Electron and ion distribution functions show specific features that are the signature of probe motion. In particular, the ion distribution function at the probe front side exhibits a filament with positive radial velocity. It corresponds to a population of rammed ions that were reflected by the electric field close to the positively biased probe. Numerical simulations reveal that two populations of trapped electrons exist: one orbiting around the probe and the other with trajectories confined at the probe front side. The latter helps to neutralize the reflected ions, thus explaining a paradox in past probe theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High resolution field effect sensing of ferroelectric charges.

Nanoscale manipulation of surface charges and their imaging are essential for understanding local electronic behaviors of polar materials and advanced electronic devices. Electrostatic force microscopy and Kelvin probe force microscopy have been extensively used to probe and image local surface charges responsible for electrodynamics and transport phenomena. However, they rely on the weak electric force modulation of cantilever that limits both spatial and temporal resolutions. Here we present a field effect transistor embedded probe that can directly image surface charges on a length scale of 25 nm and a time scale of less than 125 {micro}s. On the basis of the calculation of net surface charges in a 25 nm diameter ferroelectric domain, we could estimate the charge density resolution to be as low as 0.08 {micro}C/cm{sup 2}, which is equivalent to 1/20 electron per nanometer square at room temperature.

36 MATERIALS SCIENCE↗

Measurement of probe displacement to the thermal resolution limit in photonic force microscopy using a miniature quadrant photodetector

A photonic force microscope comprises of an optically trapped micro-probe and a position detection system to track the motion of the probe. Signal collection for motion detection is often carried out using the backscattered light off the probe-however, this mode has problems of low S/N due to the small backscattering cross sections of the micro-probes typically used. The position sensors often used in these cases are quadrant photodetectors. To ensure maximum sensitivity of such detectors, it would help if the detector size matched with the detection beam radius after the condenser lens (which for backscattered detection would be the trapping objective itself). To suit this condition, we have used a miniature displacement sensor whose dimensions makes it ideal to work with 1:1 images of micrometer-sized trapped probes in the backscattering detection mode. The detector is based on the quadrant photo-integrated chip in the optical pick-up head of a compact disc player. Using this detector, we measured absolute displacements of an optically trapped 1.1 {mu}m probe with a resolution of {approx}10 nm for a bandwidth of 10 Hz at 95% significance without any sample or laser stabilization. We characterized our optical trap for different sized probes by measuring the power spectrum for each probe to 1% accuracy, and found that for 1.1 {mu}m diameter probes, the noise in our position measurement matched the thermal resolution limit for averaging times up to 10 ms. We also achieved a linear response range of around 385 nm with cross talk between axes {approx_equal}4% for 1.1 {mu}m diameter probes. The detector has extremely high bandwidth (few MHz) and low optical power threshold-other factors that can lead to its widespread use in photonic force microscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atomic Force Microscope Active Optical Probe for Single-Molecule Imaging and Time-Resolved Optical Spectroscopy (DOE SBIR Phase II/IIA Final Report)

Actoprobe LLC reports on the results of its DOE SBIR Phase II/IIA project on the development of Atomic Force Microscope Active Optical Probe for Single-Molecule Imaging and Time-Resolved Optical Spectroscopy. While chemistry science and technology greatly benefit from Atomic Force Microscopy in surface characterization, time-resolved chemical imaging on the single-molecule level lags far behind. Current scanning probe microscopy only obtains information about mechanical but not optical/chemical properties. To address this problem, the Actoprobe LLC research team has proposed a novel class of Atomic Force Microscopy probes, Ultra-Fast Pulsed Active Atomic Force Microscopy Optical Probes (UFP AAOPs), that will allow ultrafast time-resolved optical and chemical imaging at the nanoscale. As envisioned, these unique optical probes will perform the functions of conventional Atomic Force Microscopy probes and, in addition, will simultaneously provide chemical information about molecular scale interactions. This innovation is accomplished by integrating an ultrafast pulsed Quantum Dot laser source into an Atomic Force Microscopy probe. This report describes our progress with the fabrication of an ultrafast micrometer-size semiconductor laser, based on “artificial atoms” - Quantum Dots, integrated with an Atomic Force Microscopy probe. In this Phase II/IIA project, we have demonstrated the feasibility of the UFP AAOP concept by fabricating a first prototype of the UFP AAOP. The excellent performance of the probe has been proven in terms of AFM and optical spatial resolution through rigorous tests. The UFP AAOP provides pulses with less than 4 ps duration and higher than 11 GHz repetition rate, and spatial resolution better than 300 nm at 1240 nm wavelength. Technically, it is possible to reduce the pulse width to less than 1 ps and to improve lateral resolution to ~ 0.5 nm, which implies the potential capability for the probe to characterize chemical compounds with single-molecule resolution. The UFP AAOP fabrication procedure has been developed for wafer-scale production of multiple devices, with the yield of the process estimated to be lower than 1% with the limited fabrication capabilities and equipment available for use in the research project. However, using high-volume production tools and special GaAs processing equipment, the yield can be significantly improved, theoretically to ~ 50%. Finally, economic feasibility and scale-up manufacturing potential were analyzed for UFP AAOP and found to be very promising. In summary, the Actoprobe team has successfully demonstrated the feasibility of the UFP AAOP concept.

36 MATERIALS SCIENCE↗