Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRESSURE DROP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Convective heat transfer in a high aspect ratio minichannel heated on one side

Experimental results are presented for single-phase heat transfer in a narrow rectangular minichannel heated on one side. The aspect ratio and gap thickness of the test channel were 29:1 and 1.96 mm, respectively. Friction pressure drop and Nusselt numbers are reported for the transition and fully turbulent flow regimes, with Prandtl numbers ranging from 2.2 to 5.4. Turbulent friction pressure drop for the high aspect ratio channel is well-correlated by the Blasius solution when a modified Reynolds number, based upon a laminar equivalent diameter, is utilized. The critical Reynolds number for the channel falls between 3500 and 4000, with Nusselt numbers in the transition regime being reasonably predicted by Gnielinski's correlation. The dependence of the heat transfer coefficient on the Prandtl number is larger than that predicted by circular tube correlations, and is likely a result of the asymmetric heating. The problem of asymmetric heating condition is approached theoretically using a boundary layer analysis with a two-region wall layer model, similar to that originally proposed by Prandtl. The analysis clarifies the influence of asymmetric heating on the Nusselt number and correctly predicts the experimentally observed trend with Prandtl number. Furthermore, a semi-analytic correlation is derived from the analysis that accounts for the effect of aspect ratio and asymmetric heating, and is shown to predict the experimental results of this study with a mean absolute error (MAE) of less than 5% for 4000 < Re < 70,000.

42 ENGINEERING↗

Diameter Versus Mass in the Development of the Orion Life Support Umbilical: A Case Study in Systems Engineering

Systems engineering could also be called the art of compromise. At its heart, systems engineering seeks to find that solution which maximizes the utility of the system, usually compromising the performance of each individual subsystem. While seemingly straightforward, systems engineering methodology is complicated when the utility to be maximized is unclear and the costs to each individual subsystem are not - or not easily - quantifiable. In this paper, we explore one such systems engineering problem within the Constellation Program as a case study in applied systems engineering. During suited operations, astronauts within Orion will be connected to an umbilical to receive and return breathing gas. The pressure drop associated with this umbilical must be overcome by the Orion vehicle. A smaller umbilical, which is desirable for crew operations, means a higher pressure drop, resulting in additional mass and power for the vehicle. We outline the technical considerations in the development of this integrated system and discuss the method by which we reached the ultimate solution. This paper, while just one example of the kind of problem solving that happens every day, offers insight into what happens when the theories of systems engineering are put into practice.

Jordan, Nicole↗

OPTIMIZATION OF A NUCLEAR VESSEL OUTLET FOR INCIDENT MONITORING

Classical nuclear core fluidic design techniques require improvement to better align with modern technological innovations. The US Department of Energy’s Office of Nuclear Energy (DOE-NE) Transformational Challenge Reactor (TCR) program is deploying additive manufacturing and advanced modeling and simulation to reimagine these designs. With the aid of modern computing power, computerized design optimization can be implemented to remove unwanted pressure drop while simultaneously optimizing flow structures, resulting in new opportunities to enable advanced instrumentation and monitoring capabilities.Previous development of geometric specifications for the TCR pressure vessel’s outlet plenum used design optimization to (1) limit pressure losses below 3.5 kPa (~0.5 psi) and (2) create a fluidic plane in which the temperature variation would not exceed ±5°C. This significant limit of the allowable pressure drop stems from the overarching goal of the TCR program to apply cutting edge techniques and unconventional thinking to demonstrate potential opportunities in additive manufacturing (AM).This paper expands the previous work by optimizing thermowell locations for robust measurements by explicitly modeling them and the resulting flow impacts. Additionally, a single core coolant channel was chosen to represent an event that causes an increased bulk flow temperature increase of 100°C.High fidelity unsteady Reynolds-averaged Navier-Stokes (URANS) simulations of the conjugate heat transfer problem were run in Siemen’s Star-CCM+ for this study. Next, the bulk flow temperature of a single coolant channel was increased by 100°C and was allowed to converge again. Finally, statistical analysis using a sequential probability ratio test (SPRT) was used to determine the elapsed time the thermocouples took to discover the increased bulk flow temperature.

See, Nate↗

Investigating ceramic breeder pebble beds thermomechanics evolution using novel pressure mapping technology

Ceramic breeder pebble beds undergo complex thermomechanical interactions during blanket operation due to stress build-up and relaxation under the effects of confined thermal expansion, thermal cycling, and creep. Understanding the evolution of such processes can aid in guiding blanket design/assembly, breeder materials developments, predicting performance and possible failure modes. This study introduces experimental techniques that enable us to create an environment in which the pebble bed stresses are organically generated as a result of relevant temperature gradients and magnitudes that allows us to observe the combined thermomechanical interaction effects. A novel non-intrusive in-situ tactile pressure sensing technology is used to generate real-time contact pressure maps revealing the spatial and temporal stress evolution with emphasis on understanding the roles that each of the thermo-mechanical forces play in dictating the pebble bed’s equilibrium conditions. Two types of bed-wall contact pressure drop were recorded: (1) within the subsequent cycles due to pebbles irreversible rearrangements, and (2) within the cycle itself as a result of creep/stress-relaxation. Consequently, by the fourth cycle, the contact pressure drops to negligible values and remains stable. This stability is attributed to two modes of self-regulation: (1) stress self-regulation as a result of pressure rise and fall due to thermal expansion and creep/thermal cycling, respectively, and (2) temperature self-regulation due to the locally enhanced thermal conductivity in the core region of the bed accompanied by deteriorated interface conductance. These two mechanisms are desirable as they lower the probability of the events of pebbles crushing and thermal runaways under high temperatures/stresses and poor heat extraction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase shift method to estimate solids circulation rate in circulating fluidized beds

While solids circulation rate is a critical design and control parameter in circulating fluidized bed (CFB) reactor systems, there are no available techniques to measure it directly at conditions of industrial interest. Cold flow tests have been conducted at NETL in an industrial scale CFB unit where the solids flow has been the topic of research in order to develop an independent method which could be applied to CFBs operating under the erosive and corrosive high temperatures and pressures of a coal fired boiler or gasifier. The dynamic responses of the CFB loop to modest modulated aeration flows in the return leg or standpipe were imposed to establish a periodic response in the unit without causing upset in the process performance. The resulting periodic behavior could then be analyzed with a dynamic model and the average solids circulation rate could be established. This method was applied to the CFB unit operated under a wide range of operating conditions including fast fluidization, core annular flow, dilute and dense transport, and dense suspension upflow. In addition, the system was operated in both low and high total solids inventories to explore the influence of inventory limiting cases on the estimated results. The technique was able to estimate the solids circulation rate for all transport circulating fluidized beds when operating above upper transport velocity, U{sub tr2}. For CFB operating in the fast fluidized bed regime (i.e., U{sub g}< U{sub tr2}), the phase shift technique was not successful. The riser pressure drop becomes independent of the solids circulation rate and the mass flow rate out of the riser does not show modulated behavior even when the riser pressure drop does.

42 ENGINEERING↗

Conjugate Heat Transfer Analysis in Pressurized Helium Gas Cooling Channels

Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 from the irradiation of Mo-100 targets. The NMR target consists of an Inconel window that allows the electron beam to penetrate and irradiate a stack of Mo-100 disks. The irradiation process generates large amounts of heat and is cooled using pressurized helium gas flowing at 400 g/s. LANL provides both numerical analysis support and experimental support. Computational fluid dynamics (CFD) and conjugate heat transfer (CHT) analysis are performed on the NMR target to analyze the helium flow and volumetric heating through the NMR system. In this iteration of numerical analysis, we update the Mo-100 disk thickness to 0.74 mm and the gap between the Inconel window and the first disk to 0.69 mm. Estimates of the heat flux from the electron beams from Monte Carlo N-Particle code (MCNP) analysis were combined with CFD to perform the CHT analysis. The pressure drop through the targets, force applied on the first disk, beam window and target disk temperatures are some of the quantities estimated using the simulations. The pressure drop through the target was estimated as 0.198 MPa, while the force due to venturi effects across the first disk was estimated to be 100 N. The results show maximum window temperatures over 600 °C and peak disk temperatures over 1600 °C. Past work has shown that beyond 650-700 °C, the Inconel window becomes susceptible to yield and rupture. The increased temperature in these results reduces the margin of error possible on beam spot size. The disk temperatures showed a sinusoidal distribution with the 6 th – 8 th disk from each window exhibiting highest disk temperatures. The peak temperature of the stainless steel housing was close to 316 °C and that of the laminations and spacers was approximately 582 °C.

43 PARTICLE ACCELERATORS↗

Electrochemically driven carbon dioxide separation

This project explored the viability of a Ni(OH) 2 based hydroxide exchange membrane carbon capture (HEMCC) device for direct air capture. It is built off an H 2 fuel cell based HEMCC previously developed in the Yushan Yan group at University of Delaware. Taking the same membrane-based, electrochemically driven pH gradient concept, similar flux performance was able to be seen in the Ni(OH) 2 system as the H 2 system when using comparable current densities. The project produced two types of membrane electrode assemblies (MEA). The first was a traditional MEA with two electrodes and a membrane, the second was a flow-through membrane MEA. Consistent performance was achieved with the traditional MEA with an energy cost of 1.1 MWh∙ton -1 and flux of 82 kg∙m -2 ∙yr -1 . This was the most stable of the two designs. This project investigated strategies to improve performance with a flow-through membrane design. Two designs were made, one with a cast phase inversion membrane, and one with powdered membrane layer. The template phase inversion membrane achieved low pressure drop but had performance limitations due to a skin layer of membrane limiting CO 2 gas transport. The powdered membrane layer had better performance but higher pressure drop. Finally, using the powdered membrane, commercial battery materials were able to be used in order to achieve higher flux. This showed that the flow through membrane design does have the capability to overcome flux inefficiencies in the traditional MEA. Moreover, the process design of the system is proposed and given in this project. The process mass and energy balances were calculated for a reference plant of 1000 t/yr CO 2 capture, which contains several subsystems, e.g. air processing subsystem, electrical subsystem, and CO 2 purification and compression subsystem is designed and evaluated. Based on our calculation, When the power consumption for stack is 1 MWh t -1 CO 2 , Additional 382 kWh t -1 CO 2 will be consumed by other subsystem of the plant, i.e. The total power consumption of 1.38 MWh t -1 CO 2 , lower than the final milestone of 1.5 MWh t -1 CO 2 in this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pressure losses for laminar flow in the entrance region of ducts of rectangular and equilateral triangular cross section.

The velocity profiles upon which the pressure-loss calculations are based, are recomputed using the previously described method of reference (1960). The pressure drop is then computed using the energy integral equation; both rectangular and equilateral triangular ducts are considered. It is demonstrated that, using this equation, the pressure-drop parameter can be improved.

Miller, R. W.↗

Performance evaluation of a wrapped around condenser for heat pump water heater applications

In this report, accurate performance evaluation of a wrapped-around condenser for heat pump water heaters (WHPWH) is critical since the COP of the system depends heavily on thermal stratification and condenser design. An analytical, quasi-steady state heat balance method has been developed to determine the optimal spacing between adjacent channels, tube diameter, tube shape, and total refrigerant charge amount for the condenser. The heat transfer rate is compared among three approaches: the refrigerant thermodynamic model, the condenser-wrap fin model, and the analytical natural convection model on the inside of the tank for the three regions based on the refrigerant phase (e.g., super-heated, saturated, or subcooled). The heat transfer rate was predicted by a combination of slug-plug and annular flow for a D-shaped helical tube. Experimental data were used as boundary conditions for validating the model. The rate of heat transfer based on tube shape and tank wall temperatures was compared by CFD analysis. Parametric analysis indicates a tradeoff between refrigerant mass, pressure drop, tube diameter, and tube length to maximize the heat transfer rate. The model suggests the saturated region length can be extended by 400%, and the condenser pressure drop can be reduced by 23% with an optimal spacing pattern.

42 ENGINEERING↗

A Critical Literature Review of Defrost Technologies for Heat Pumps and Refrigeration Systems

When the operating conditions are extremely cold and humid and the surface temperature of the heat exchanger well below the freezing point (lower than the dew point temperature of the air) moisture from the air stream will freeze on the surface after condensation and the frost will start growing. The frost growth degrades the performance of the system considerably. It hinders the airflow and increases the pressure drop through the coil which means more fan power is requires for to maintain the desired flow rate. With reduced flow rate due to the increase of pressure drop, system’s capacity drops rapidly. In the case of heat pump the capacity of the evaporator decreases due to the airflow drop, which reduces the overall heating capacity and coefficient of performance of the heat pump. Additionally, the frost layer increases the thermal resistance to the heat transfer between the air and refrigerant. The reduction in airflow and increased thermal resistance reduces the heat energy extracted by the evaporator and decreases the heat pump capacity and efficiency. Similar process is observed for the cooling coils of commercial refrigeration system where the frost growth can dramatically reduce the system capacity. Once the performance reaches its minimum acceptable stage, a defrost process is introduced to remove the frost layer and to achieve the performance at the start of the cycle. The frost defrost process is repeated continuously. Overall the frost growth is highly undesired phenomena which can cause considerable reduction in performance of the system.

42 ENGINEERING↗

Effect of swirler-mounted mixing venturi on emissions of flame-tube combustor using jet A fuel

Six headplate modules in a flame-tube combustor were evaluated. Unburned hydrocarbons, carbon monoxide, and oxides of nitrogen were measured for three types of fuel injectors both with and without a mixing venturi. Tests were conducted using jet A fuel at an inlet pressure of 0.69 megapascal, an inlet temperature of 478 K, and an isothermal static pressure drop of 3 percent. Oxides of nitrogen were reduced by over 50 percent with a mixing venturi with no performance penalties in either other gaseous emissions or pressure drop.

Ercegovic, D. B.↗

An Analysis of Nuclear-Rocket Nozzle Cooling

A nuclear-rocket regenerative-cooling analysis was conducted over a range of reactor power of 46 to 1600 megawatts and is summarized herein. Although the propellant (hydrogen) is characterized by a large heat-sink capacity, an analysis of the local heat-flux capability of the coolant at the nozzle throat indicated that, for conventional values of system pressure drop, the cooling capability was inadequate to maintain a selected wall temperature of 1440 R. Several techniques for improving the cooling capability were discussed, for example, high pressure drop, high wall temperature, refractory wall coatings, thin highly conductive walls, and film cooling. In any specific design a combination of methods will probably be utilized to achieve successful cooling.

Robbins, William H.↗

Filter Efficiency and Pressure Testing of Returned ISS Bacterial Filter Elements (BFEs)

The air quality control equipment aboard the International Space Station (ISS) and future deep space exploration vehicles provide the vital function of maintaining a clean cabin environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of sedimentation. The ISS Environmental Control and Life Support (ECLS) system architecture in the U.S. Segment uses a distributed particulate filtration approach consisting of traditional High-Efficiency Particulate Air (HEPA) filters deployed at multiple locations in each U.S. Seg-ment module; these filters are referred to as Bacterial Filter Elements, or BFEs. In our previous work, we presented results of efficiency and pressure drop measurements for a sample set of two returned BFEs with a service life of 2.5 years. In this follow-on work, we present similar efficiency, pressure drop, and leak tests results for a larger sample set of six returned BFEs. The results of this work can aid the ISS Program in managing BFE logistics inventory through the stations planned lifetime as well as provide insight for managing filter element logistics for future exploration missions. These results also can provide meaningful guidance for particulate filter designs under consideration for future deep space exploration missions.

ISS Air Quality↗

Development of MHD flow in the entrance region of a channel.

A general method has been developed for determining the developing magnetohydrodynamic flow in the entrance region of a parallel-plate channel. Closed form solutions are obtained. Numerical results are presented for the development of velocity distribution, pressure drop, and magnetohydrodynamic entrance length at different Hartmann numbers. At large Hartmann numbers, the magnetic field effect becomes dominant and the magnetohydrodynamic entrance length becomes negligible. Also, the pressure drop is enhanced by the magnetic field. Comparison of results with direct numerical analysis shows excellent agreement.-

Wu, S. T.↗

Comments on settling chamber design for quiet, blowdown wind tunnels

Transfer of an existing continous circuit supersonic wind tunnel to Langley and its operation there as a blowdown tunnel is planned. Flow disturbance requirements in the supply section and methods for reducing the high level broad band acoustic disturbances present in typical blowdown tunnels are reviewed. Based on recent data and the analysis of two blowdown facilities at Langley, methods for reducing the total turbulence levels in the settling chamber, including both acoustic and vorticity modes, to less than one percent are recommended. The pertinent design details of the damping screens and honeycomb and the recommended minimum pressure drop across the porous components providing the required two orders of magnitude attenuation of acoustic noise levels are given. A suggestion for the support structure of these high pressure drop porous components is offered.

Beckwith, I. E.↗

METAL FOAMS: NOVEL MATERIALS FOR AIR COOLING AND HEATING APPLICATION- PERFORMANCE UNDER DRY, WET AND FROSTING CONDITIONS

Metal foams have emerged as a potential material for advanced heat exchangers in air-cooling systems. The novel materials have a large surface-area-to-volume ratio and a tortuous structure which promotes flow mixing in heat exchanger applications. The current study provides an overview of the thermal-hydraulic performance of metal foam heat exchangers under dry, wet and frosting operations. The experiments have been conducted in a wind tunnels at a range of operating conditions varying air flow rate, inlet air temperature and relative humidity and the associated pressure drop and heat transfer rate have been measured. The impact of metal foam geometry has been evaluated and the findings have been summarized for heat transfer rate and pressure drop when the heat exchanger operates at various operating conditions.

Nawaz, Kashif↗

Refractory high entropy alloy compact heat exchanger

Several innovative technologies, including pressure-drop minimization, advanced refractory high entropy alloys, and advanced manufacturing can provide a compact heat exchanger that extends the state-of-the-art heat-exchanger operating range. The compact heat exchanger can reduce pressure drop losses by 100 to 500%, while retaining most of the heat transfer. The compact heat exchanger can be fabricated from refractory high entropy alloys that have favorable corrosion, thermal fatigue, and creep properties at high temperatures and pressures. Therefore, the compact heat exchanger using high entropy alloys can operate at >800° C. and 80 bars.

Kustas, Andrew↗

Design complexity and performance analysis in additively manufactured heat exchangers

The main objective of this research is to investigate the tradeoffs between design complexity and thermal performance in additively manufactured metallic heat exchangers. Such heat exchangers have become a favorite topic for investigation in various fields ranging from air conditioning to aircraft gas turbine engines. In particular, high manufacturing cost has emerged as the major drawback in broad applications of manifold-microchannel heat exchanger (MMHXs). The possibility of cost-effective manufacturing has generated wide interest in applying additive manufacturing (AM) for fabricating MMHXs. Furthermore, AM technologies will provide an opportunity for enhanced design and superior heat transfer performance. In this study, innovative MMHXs are designed and fabricated through selective laser melting. An experimental setup was designed to measure pressure drop and heat transfer for the developed MMHXs with a wide range of Reynolds numbers. Furthermore, the coefficient of performance was calculated based on the heat flow rate, air pressure drop, and air flow rate. Measurement results demonstrated that in some scenarios adding more internal features, i.e., increasing design complexity, does not necessarily improve the MMHX performance.

10 SYNTHETIC FUELS↗