Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Langmuir probe measurements and mass spectrometry of plasma plumes generated by laser ablation of La{sub 0.4}Ca{sub 0.6}MnO{sub 3}

The plasma formed in vacuum by UV nanosecond laser ablation of La{sub 0.4}Ca{sub 0.6}MnO{sub 3} in the fluence range of 0.8 to 1.9 J cm{sup −2} using both Langmuir probe analysis and energy-resolved mass spectrometry has been studied. Mass spectrometry shows that the main positive ion species are Ca{sup +}, Mn{sup +}, La{sup +}, and LaO{sup +}. The Ca{sup +} and Mn{sup +} energy distributions are quite broad and lie in the 0–100 eV region, with the average energies increasing with laser fluence. In contrast, the La{sup +} and LaO{sup +} distributions are strongly peaked around 10 eV. The net time-of-arrival signal derived from the measured positive ion energy distributions is broadly consistent with the positive ion signal measured by the Langmuir probe. We also detected a significant number of O{sup −} ions with energies in the range of 0 to 10 eV. The Langmuir probe was also used to measure the temporal variation of the electron density and temperature at 6 cm from the ablation target. In the period when O{sup −} ions are found at this position, the plasma conditions are consistent with those required for significant negative oxygen ion formation, as revealed by studies on radio frequency excited oxygen plasma.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hollow Cathode and Keeper-region Plasma Measurements Using Ultra-fast Miniature Scanning Probes

In order to support the development of comprehensive performance and life models for future deep space missions that will utilize ion thrusters, we have undertaken a study of the plasma structure in hollow cathodes using an new pneumatic scanning probe diagnostic. This device is designed to insert a miniature probe directly into the hollow cathode orifice from either the upstream insert region in the interior of the hollow cathode, or from the downstream keeper-plasma region at the exit of the hollow cathode, to provide complete axial profiles of the discharge plasma parameters. Previous attempts to diagnose this region with probes was Limited by the melting of small probes in the intense discharge near the orifice, or caused significant perturbation of the plasma by probes large enough to survive. Our new probe is extremely compact, and when configured as a single Langmuir probe, the ceramic tube insulator is only 0.5mm in diameter and the current collecting conductor has a total area of 0.002 cm2. A series of current-voltage characteristics are obtained by applying a rapid sawtooth voltage waveform to the probe as it is scanned by the pneumatic actuator into and out of the plasma region, The bellow-sealed pneumatic drive scans the probe 4 cm in the cathode insert region and 10 cm in the anode/keeper plasmas region at average speeds of about 1 mm/msec, and the residence time at the end of the insertion stroke in the densest part of the plasma near the orifice is measured to be only 10 msec. Since the voltage sweep time is fast compared to the motion of the probe, axial profiles of the plasma density, temperature and potential with reasonable spatial resolution are obtained. Measurements of the internal cathode pressures and the axial plasma-parameter profiles for a hollow cathode operating at discharge currents of up to 35 A in xenon will be presented.

plasma generation↗

Simultaneous use of camera and probe diagnostics to unambiguously identify and study the dynamics of multiple underlying instabilities during the route to plasma turbulence

We use multiple-tip Langmuir probes and fast imaging to unambiguously identify and study the dynamics of underlying instabilities during the controlled route to fully-developed plasma turbulence in a linear magnetized helicon plasma device. Langmuir probes measure radial profiles of electron temperature, plasma density and potential; from which we compute linear growth rates of instabilities, cross-phase between density and potential fluctuations, Reynold's stress, particle flux, vorticity, time-delay estimated velocity, etc. Fast imaging complements the 1D probe measurements by providing temporally and spatially resolved 2D details of plasma structures associated with the instabilities. We find that three radially separated plasma instabilities exist simultaneously. Density gradient driven resistive drift waves propagating in the electron diamagnetic drift direction separate the plasma into an edge region dominated by strong, velocity shear driven Kelvin-Helmholtz instabilities and a central core region which shows coherent Rayleigh-Taylor modes propagating in the ion diamagnetic drift direction. The simultaneous, complementary use of both probes and camera was crucial to identify the instabilities and understand the details of the very rich plasma dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamics of Carrier Plasma and Thermal Waves in Ion Implanted Si with Varying Pump and Probe Wavelengths

Dynamics of the carrier plasma- and thermal-waves in ion implanted Si is studied using the Modulated Optical Reflectance (MOR) technique with varying pump and probe beam wavelengths. It is shown that selection of the pump and probe beam wavelengths allows control of the MOR signal behavior on Si samples implanted with a wide range of implantation energies and doses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lithium Wall Conditioning And Surface Dust Detection On NSTX

Lithium evaporation onto NSTX plasma facing components (PFC) has resulted in improved energy confinement, and reductions in the number and amplitude of edge-localized modes (ELMs) up to the point of complete ELM suppression. The associated PFC surface chemistry has been investigated with a novel plasma material interface probe connected to an in-vacuo surface analysis station. Analysis has demonstrated that binding of D atoms to the polycrystalline graphite material of the PFCs is fundamentally changed by lithium - in particular deuterium atoms become weakly bonded near lithium atoms themselves bound to either oxygen or the carbon from the underlying material. Surface dust inside NSTX has been detected in real-time using a highly sensitive electrostatic dust detector. In a separate experiment, electrostatic removal of dust via three concentric spiral-shaped electrodes covered by a dielectric and driven by a high voltage 3-phase waveform was evaluated for potential application to fusion reactors

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-resolved and multiple-angle Thomson scattering on gas-puff Z-Pinch plasmas at pinch time

A 526.5 nm Thomson scattering diagnostic laser enables probing of the plasma conditions of neon gas-puff z-pinch implosions with temporal resolution. Splitting the laser into two 2.5 J pulses, both 2.3 ns in duration and separated by 4 ns, allows observation of sub-nanosecond time-resolved spectra for a total time of 7 ns. Collection optics were set at 90° and 30° to the laser, observing the same on-axis scattering volume with a radial extent of 0.4 mm. The spectra from both angles were collected by using the same streak camera, using a coupling system that allowed us to obtain temporal, spectral, and angular resolution in the same image. By comparing the ion-acoustic spectra from the two angles, we determined electron temperature and a range of possible electron densities. Measurements made in the 1-3 ns period before pinch time show best fit (determined by a least-squares method) electron densities of around 2 × 10 19 cm -3 , increasing to 1.5 × 10 20 cm -3 in the 3 ns following the start of the x-ray burst (t = 0 ns) from the pinch. The electron temperature increases from 300 eV to 500 eV at t = 0 ns before decreasing to below 300 eV after pinch time. With the present parameters (probe beam, collection angles, and electron temperature and density), this diagnostic method is too insensitive to electron density to provide more than a constraint on that parameter. Plasma regimes in which this technique could determine electron density with some precision are calculated.

47 OTHER INSTRUMENTATION↗

Spectroscopic and probe measurements of the electron temperature in the plasma of a pulse-periodic microwave discharge in argon

A pulse-periodic 2.45-GHz electron-cyclotron resonance plasma source on the basis of a permanent- magnet mirror trap has been constructed and tested. Variations in the discharge parameters and the electron temperature of argon plasma have been investigated in the argon pressure range of 1 × 10{sup –4} to 4 × 10{sup –3} Torr at a net pulsed input microwave power of up to 600 W. The plasma electron temperature in the above ranges of gas pressures and input powers has been measured by a Langmuir probe and determined using optical emission spectroscopy (OES) from the intensity ratios of spectral lines. The OES results agree qualitatively and quantitatively with the data obtained using the double probe.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Territorial characteristics of low frequency electrostatic fluctuations in a simple magnetized torus

This paper presents an experimental investigation of turbulence in simple toroidal plasma devices without rotational transform. It is argued that Rayleigh-Taylor (flute interchange) mode may be one of the source mechanisms for the observed turbulence but is not sufficient to explain its observed global characteristics. Taking BETA device as an example, we show that pure Rayleigh-Taylor mode cannot explain (i) the observation of mode maximum at the location other than where density scale length is minimum, (ii) the comparable value of amplitude level of fluctuations in good curvature region, and (iii) the decrease in the mode amplitude with increasing magnetic field. Investigations have revealed that there exists not only poloidal plasma flow but also that it is sheared. Including this effect explains the first observation. However, modification brought about by velocity shear in the Rayleigh-Taylor mode still does not explain our second and third observations. We have taken an approach that since Rayleigh-Taylor is not excited in a good curvature region, it cannot be the source of turbulence there. Nor is it defensible to say that turbulence born in a bad curvature region is carried over through ExB rotation to the good curvature region. Consequently, we have invoked cross-field Simon-Hoh instability for this region. Experimental evidence supporting our proposal is presented. This paper concludes that toroidal devices have simultaneous existence of different self-consistent sources of turbulence in different regions of the device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Discharge Oscillations in a Permanent Magnet Cylindrical Hall-Effect Thruster

Measurements of the discharge current in a cylindrical Hall thruster are presented to quantify plasma oscillations and instabilities without introducing an intrusive probe into the plasma. The time-varying component of the discharge current is measured using a current monitor that possesses a wide frequency bandwidth and the signal is Fourier transformed to yield the frequency spectra present, allowing for the identification of plasma oscillations. The data show that the discharge current oscillations become generally greater in amplitude and complexity as the voltage is increased, and are reduced in severity with increasing flow rate. The breathing mode ionization instability is identified, with frequency as a function of discharge voltage not increasing with discharge voltage as has been observed in some traditional Hall thruster geometries, but instead following a scaling similar to a large-amplitude, nonlinear oscillation mode recently predicted in for annular Hall thrusters. A transition from lower amplitude oscillations to large relative fluctuations in the oscillating discharge current is observed at low flow rates and is suppressed as the mass flow rate is increased. A second set of peaks in the frequency spectra are observed at the highest propellant flow rate tested. Possible mechanisms that might give rise to these peaks include ionization instabilities and interactions between various oscillatory modes.

Polzin, K. A.↗

Matched dipole probe for magnetized low electron density laboratory plasma diagnostics

In this paper, a diagnostic method for magnetized and unmagnetized laboratory plasma is proposed, based on impedance measurements of a short matched dipole. The range of the measured electron densities is limited to low density plasmas (10{sup 12}–10{sup 15 }m{sup −3}), where other diagnostic methods have strong limitations on the magnetic field strength and topology, plasma dimensions, and boundary conditions. The method is designed for use in both large- and small-dimension plasma (<10 cm) without or with strong non-homogeneous magnetic field, which can be undefined within the probe size. The design of a matched dipole probe allows to suppress the sheath resonance effects and to reach high sensitivity at relatively small probe dimensions. Validation experiments are conducted in both magnetized (B ∼ 170 G) and unmagnetized (B = 0) low density (7 × 10{sup 12 }m{sup −3}–7 × 10{sup 13 }m{sup −3}) low pressure (1 mTorr) 10 cm scale plasmas. The experimentally measured data show very good agreement with an analytical theory both for a non-magnetized and a magnetized case. The electron density measured by the matched dipole and Langmuir probes in the range of 7 × 10{sup 12 }m{sup −3}–7 × 10{sup 13 }m{sup −3} show less than 30% difference. An experimentally measured tolerance/uncertainty of the dipole probe method is estimated to ±1% for plasma densities above 2 × 10{sup 13 }m{sup −3}. A spatial resolution is estimated from the experiments to be about 3d, where d is the dipole diameter. The diagnostic method is also validated by comparing the measured plasma impedance curves with results of analytical modelling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rethinking Use of the OML Model in Electric Sail Development

In 1924, Irvin Langmuir and H. M. Mott-Smith published a theoretical model for the complex plasma sheath phenomenon in which they identified some very special cases which greatly simplified the sheath and allowed a closed solution to the problem. The most widely used application is for an electrostatic, or "Langmuir," probe in laboratory plasma. Although the Langmuir probe is physically simple (a biased wire) the theory describing its functional behavior and its current-voltage characteristic is extremely complex and, accordingly, a number of assumptions and approximations are used in the LMS model. These simplifications, correspondingly, place limits on the model's range of application. Adapting the LMS model to real-life conditions is the subject of numerous papers and dissertations. The Orbit-Motion Limited (OML) model that is widely used today is one of these adaptions that is a convenient means of calculating sheath effects. Since the Langmuir probe is a simple biased wire immersed in plasma, it is particularly tempting to use the OML equation in calculating the characteristics of the long, highly biased wires of an Electric Sail in the solar wind plasma. However, in order to arrive at the OML equation, a number of additional simplifying assumptions and approximations (beyond those made by Langmuir-Mott-Smith) are necessary. The OML equation is a good approximation when all conditions are met, but it would appear that the Electric Sail problem lies outside of the limits of applicability.

Stone, Nobie H.↗

Innovative measurement of Debye shielding in plasmas by Lyman-α radiation of a probing metastable hydrogen beam

Answering to a long-standing challenge, a new way to non-intrusively measure weak electric fields in plasmas is presented. Here we show it using an H(2s) atomic probe beam, obtained from the conversion of H{sup +} ions into H(2s) either by collisions with H{sub 2} residual gas or in a resonant charge exchange cesium cell. The probe beam is sent between two polarized plates creating an electric field applied within a thermionic plasma. Indeed the interaction between a metastable H(2s) atomic hydrogen beam and an external electric field leads to the emission of the Lyman-alpha line owing to the Stark mixing of the 2s{sub 1/2} and 2p{sub 1/2} levels. When the field is weak, it can be treated as a perturbation of these two states separated by a small amount of energy called Lamb-shift. It induces a radiation with intensity proportional to the square modulus of the electric field which is measured in a direction perpendicular to the probe beam. Contrary to measurements in vacuum, the Debye sheath formation is clearly observed in the presence of plasma. This contribution reviews: presentation of Stark mixing of the 2s{sub 1/2} and 2p{sub 1/2} levels and of Lamb shift for hydrogen-like atoms, brief description of the experimental set-up, observation of the formation of a sheath between two polarized plane electrodes in a plasma, either with a probe ion beam, or atom beam.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Refractive Index Seen by a Probe Beam Interacting with a Laser-Plasma System

Here, we report the first complete set of measurements of a laser-plasma optical system’s refractive index, as seen by a second probe laser beam, as a function of the relative wavelength shift between the two laser beams. Both the imaginary and real refractive index components are found to be in good agreement with linear theory using plasma parameters measured by optical Thomson scattering and interferometry; the former is in contrast to previous work and has implications for crossed-beam energy transfer in indirect-drive inertial confinement fusion, and the latter is measured for the first time. The data include the first demonstration of a laser-plasma polarizer with 85$-$87% extinction for the particular laser and plasma parameters used in this experiment, complementing the existing suite of high-power, tunable, and ultrafast plasma-based photonic devices.

42 ENGINEERING↗

Characteristic of a triple-cathode vacuum arc plasma source

In order to generate a better ion beam, a triple-cathode vacuum arc plasma source has been developed. Three plasma generators in the vacuum arc plasma source are equally located on a circle. Each generator initiated by means of a high-voltage breakdown between the cathode and the anode could be operated separately or simultaneously. The arc plasma expands from the cathode spot region in vacuum. In order to study the behaviors of expanding plasma plume generated in the vacuum arc plasma source, a Langmuir probe array is employed to measure the saturated ion current of the vacuum arc plasma source. The time-dependence profiles of the saturated current density of the triple vacuum arc plasma source operated separately and simultaneously are given. Furthermore, the plasma characteristic of this vacuum arc plasma source is also presented in the paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Generating electron cyclotron resonance plasma using distributed scheme

This study employs a distributed microwave input system and permanent magnets to generate large-area electron cyclotron resonance (ECR) plasma. ECR plasmas were generated with nitrogen gas, and the plasma density was measured by Langmuir probe. A uniform ECR plasma with the electron density fluctuation of {+-}9.8% over 500 mm Multiplication-Sign 500 mm was reported. The proposed idea of generating uniform ECR plasma can be scaled to a much larger area by using n Multiplication-Sign n microwave input array system together with well-designed permanent magnets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microparticles in a Collisional Rf Plasma Sheath under Hypergravity Conditions as Probes for the Electric Field Strength and the Particle Charge

We used microparticles under hypergravity conditions, induced by a centrifuge, in order to measure nonintrusively and spatially resolved the electric field strength as well as the particle charge in the collisional rf plasma sheath. The measured electric field strengths demonstrate good agreement with the literature, while the particle charge shows decreasing values towards the electrode. We demonstrate that it is indeed possible to measure these important quantities without changing or disturbing the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spoke wavenumbers and mode transitions in the NASA Lewis bumpy torus

Waveforms of fluctuations of plasma potential, resulting from rotating electron and ion charge concentrations, were observed in a bumpy torus. Since these fluctuations were thought to be spoke rotations in the direction of the ExB drift, measuring the direction of spoke rotation should determine the direction of the electric fields over much of the plasma surface. A Langmuir probe was inserted into the plasma to measure the floating potential of the plasma, hence the direction of the electric field could be checked another way.

Gerdin, G. A.↗