Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE ERROR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Writing executable assertions to test flight software

An executable assertion is a logical statement about the variables or a block of code. If there is no error during execution, the assertion statement results in a true value. Executable assertions can be used for dynamic testing of software. They can be employed for validation during the design phase, and exception and error detection during the operation phase. The present investigation is concerned with the problem of writing executable assertions, taking into account the use of assertions for testing flight software. They can be employed for validation during the design phase, and for exception handling and error detection during the operation phase The digital flight control system and the flight control software are discussed. The considered system provides autopilot and flight director modes of operation for automatic and manual control of the aircraft during all phases of flight. Attention is given to techniques for writing and using assertions to test flight software, an experimental setup to test flight software, and language features to support efficient use of assertions.

Mahmood, A.↗

Error analysis of optical correlators

With the growing interest in using binary phase only filters (BPOF) in optical correlators that are implemented on magnetooptic spatial light modulators, an understanding of the effect of errors in system alignment and optical components is critical in obtaining optimal system performance. We present simulations of optical correlator performance degradation in the presence of eight errors. We break these eight errors into three groups: 1) alignment errors, 2) errors due to a combination of component imperfections and alignment errors, and 3) errors which result solely from non-ideal components. Under the first group, we simulate errors in the distance from the object to the first principle plane of the transform lens, the distance from the second principle plane of the transform lens to the filter plane, and rotational misalignment of the input mask with the filter mask. Next we consider errors which result from a combination of alignment and component imperfections. These include errors in the transform lens, the phase compensation lens, and the inverse Fourier transform lens. Lastly we have the component errors resulting from the choice of spatial light modulator. These include contrast error and phase errors caused by the non-uniform flatness of the masks. The effects of each individual error are discussed, and the result of combining all eight errors under assumptions of reasonable tolerances and system parameters is also presented. Conclusions are drawn as to which tolerances are most critical for optimal system performance.

Ma, Paul W.↗

Autonomous Phase Retrieval Calibration

The Palomar Adaptive Optics System actively corrects for changing aberrations in light due to atmospheric turbulence. However, the underlying internal static error is unknown and uncorrected by this process. The dedicated wavefront sensor device necessarily lies along a different path than the science camera, and, therefore, doesn't measure the true errors along the path leading to the final detected imagery. This is a standard problem in adaptive optics (AO) called "non-common path error." The Autonomous Phase Retrieval Calibration (APRC) software suite performs automated sensing and correction iterations to calibrate the Palomar AO system to levels that were previously unreachable.

Estlin, Tara A.↗

PHASE DAMPING IN THE SNS LINAC

Synchronous phase oscillations and the beam phase adiabatic damping curves in the SNS linac are studied with linac models and measured with all the linac beam phase monitors. This study provides a new beam diagnostic technique for detecting RF cavity phase and/or field amplitude errors in a linac with many independently phased cavities. The phase damping curves predicted in the linac longitudinal model could also be utilized to analyze the longitudinal lattice of the superconducting linac - in which each cavity gradient varies widely from the nominal design and a smooth longitudinal focusing is very important to preserve beam emittance in the linac.

43 PARTICLE ACCELERATORS↗

Two-way coherent Doppler error due to solar corona

Two-way coherent Doppler errors resulting from phase scintillations induced on the uplink by the solar corona are considered. It is shown that this error can be estimated by taking statistics on the differential Doppler measurements. Typical estimates for the error are given for four Sun-Earth-probe angles and for integration times ranging from 1 second to 1 minute. These results are based on data collected during the 1985 Voyager 2 conjunction.

Kinman, P. W.↗

The Gemini Planet Imager Calibration Wavefront Sensor Instrument

The Gemini Planet Imager is an extreme adaptive optics system that will employ an apodized-pupil coronagraph to make direct detections of faint companions of nearby stars to a contrast level of the 10(exp -7) within a few lambda/D of the parent star. Such high contrasts from the ground require exquisite wavefront sensing and control both for the AO system as well as for the coronagraph. Un-sensed non-common path phase and amplitude errors after the wavefront sensor dichroic but before the coronagraph would lead to speckles which would ultimately limit the contrast. The calibration wavefront system for GPI will measure the complex wavefront at the system pupil before the apodizer and provide slow phase corrections to the AO system to mitigate errors that would cause a loss in contrast. The calibration wavefront sensor instrument for GPI has been built. We will describe the instrument and its performance.

planet detection↗

Performance of mismatched Viterbi receiver on satellite channels

This paper presents an analysis of a satellite communication system using a Viterbi receiver. Here we have a bandlimited nonlinear channel where both uplink and downlink are taken into account as well as the effect of Intersymbol Interference, phase and time synchronization errors. In order that ISI can be combatted effectively, we use a Viterbi demodulator which is designed for the satellite channel when there is no uplink noise. The Viterbi demodulator for the channels with large memory is too complex to be implemented. To reduce the complexity, a Viterbi demodulator with memory shorter than the true channel memory is used. The objective of this paper is to analyze the performance degradation of this 'Mismatched Viterbi Receiver' due to the uplink noise and memory truncation, and to understand how the time and phase synchronization errors influence the performance.

Divsalar, D.↗

Safety Aspects of Pulsed Dose Rate Brachytherapy: Analysis of Errors in 1,300 Treatment Sessions

Purpose: To determine the safety of pulsed-dose-rate (PDR) brachytherapy by analyzing errors and technical failures during treatment. Methods and Materials: More than 1,300 patients underwent treatment with PDR brachytherapy, using five PDR remote afterloaders. Most patients were treated with consecutive pulse schemes, also outside regular office hours. Tumors were located in the breast, esophagus, prostate, bladder, gynecology, anus/rectum, orbit, head/neck, with a miscellaneous group of small numbers, such as the lip, nose, and bile duct. Errors and technical failures were analyzed for 1,300 treatment sessions, for which nearly 20,000 pulses were delivered. For each tumor localization, the number and type of occurring errors were determined, as were which localizations were more error prone than others. Results: By routinely using the built-in dummy check source, only 0.2% of all pulses showed an error during the phase of the pulse when the active source was outside the afterloader. Localizations treated using flexible catheters had greater error frequencies than those treated with straight needles or rigid applicators. Disturbed pulse frequencies were in the range of 0.6% for the anus/rectum on a classic version 1 afterloader to 14.9% for orbital tumors using a version 2 afterloader. Exceeding the planned overall treatment time by >10% was observed in only 1% of all treatments. Patients received their dose as originally planned in 98% of all treatments. Conclusions: According to the experience in our institute with 1,300 PDR treatments, we found that PDR is a safe brachytherapy treatment modality, both during and outside of office hours.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Superluminal Labview Code

This labview code is used to set the phase and amplitudes on the 72 antenna of the superluminal machine, and to map out the radiation patter from the superluminal antenna.Each antenna radiates a modulated signal consisting of two separate frequencies, in the range of 2 GHz to 2.8 GHz. The phases and amplitudes from each antenna are controlled by a pair of AD8349 vector modulators (VMs). These VMs set the phase and amplitude of a high frequency signal using a set of four DC inputs, which are controlled by Linear Technologies LTC1990 digital to analog converters (DACs). The labview code controls these DACs through an 8051 microcontroller.This code also monitors the phases and amplitudes of the 72 channels. Near each antenna, there is a coupler that channels a portion of the power into a binary network. Through a labview controlled switching array, any of the 72 coupled signals can be channeled in to the Tektronix TDS 7404 digital oscilloscope. Then the labview code takes an FFT of the signal, and compares it to the FFT of a reference signal in the oscilloscope to determine the magnitude and phase of each sideband of the signal. The code compensates for phase and amplitude errors introduced by differences in cable lengths.The labview code sets each of the 72 elements to a user determined phase and amplitude. For each element, the code runs an iterative procedure, where it adjusts the DACs until the correct phases and amplitudes have been reached.

Wheat, Robert↗

Far field beam pattern of one MW combined beam of laser diode array amplifiers for space power transmission

The far-field beam pattern and the power-collection efficiency are calculated for a multistage laser-diode-array amplifier consisting of about 200,000 5-W laser diode arrays with random distributions of phase and orientation errors and random diode failures. From the numerical calculation it is found that the far-field beam pattern is little affected by random failures of up to 20 percent of the laser diodes with reference of 80 percent receiving efficiency in the center spot. The random differences in phases among laser diodes due to probable manufacturing errors is allowed to about 0.2 times the wavelength. The maximum allowable orientation error is about 20 percent of the diffraction angle of a single laser diode aperture (about 1 cm). The preliminary results indicate that the amplifier could be used for space beam-power transmission with an efficiency of about 80 percent for a moderate-size (3-m-diameter) receiver placed at a distance of less than 50,000 km.

Kwon, Jin H.↗

Decoy States and Low-Density Parity-Check Error-Correcting Codes in Quantum Cryptography with Phase–Time Coding

The cryptographic robustness of quantum key distribution (QKD) with phase–time coding against a photon number splitting (PNS) attack is analyzed. The line length up to which a secret key distribution is guaranteed is determined both by the protocol itself and by the efficiency of error correction in raw keys. The effect of different parameters of avalanche single-photon detectors on the length of the secret key distribution line is investigated. To correct errors, various versions of low-density parity-check (LDPC) codes are considered whose efficiency today is the closest to the Shannon theoretical limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sampling Downconverter For Radio-Frequency Signals

Phase and delay errors reduced greatly. Proposed GaAs integrated-circuit for receiver of radio signals at gigahertz frequencies samples incoming signal in phase and in quadrature, digitizes it, and down-converts it to baseband in single step. Incorporates both digital and analog components in design offering improved stability, versatility, and sampling bandwidth. Eliminates need for several components found in conventional analog designs, including mixers, postmixer filters, and 90 degree phase shifter.

Thomas, J. B.↗

Error Cost Escalation Through the Project Life Cycle

It is well known that the costs to fix errors increase as the project matures, but how fast do those costs build? A study was performed to determine the relative cost of fixing errors discovered during various phases of a project life cycle. This study used three approaches to determine the relative costs: the bottom-up cost method, the total cost breakdown method, and the top-down hypothetical project method. The approaches and results described in this paper presume development of a hardware/software system having project characteristics similar to those used in the development of a large, complex spacecraft, a military aircraft, or a small communications satellite. The results show the degree to which costs escalate, as errors are discovered and fixed at later and later phases in the project life cycle. If the cost of fixing a requirements error discovered during the requirements phase is defined to be 1 unit, the cost to fix that error if found during the design phase increases to 3 - 8 units; at the manufacturing/build phase, the cost to fix the error is 7 - 16 units; at the integration and test phase, the cost to fix the error becomes 21 - 78 units; and at the operations phase, the cost to fix the requirements error ranged from 29 units to more than 1500 units

Stecklein, Jonette M.↗

Satellite sensing of aerosol absorption

A method is developed for remote sensing of aerosol absorption from satellite images of the earth's surface. The method is based on the measurement of the change in the upward radiances between a clear and a hazy day over a varying surface reflectance. For a zero change balance between brightening due to scattering and darkening due to absorption and scattering is reached. This balance is utilized via a radiative transfer model to derive the aerosol single-scattering albedo. A sensitivity study is performed, and the method is tested against laboratory measurements. It is suggested that for the case of haze introduced on top of an existing background aerosol and with a fair estimate of the scattering phase function, the error in the remotely sensed single-scattering albedo is in the range of 0.03-0.05. The main errors in the method arise from variations in the surface reflectance between the clear and the hazy days, uncertainty in the scattering phase function, and variation of the aerosol and gaseous absorption between these two days. If the satellite calibration varies with time, the measurements of single-scattering albedo can be substantially affected.

Kaufman, Yoram J.↗

Interferometer for Measuring Displacement to Within 20 pm

An optical heterodyne interferometer that can be used to measure linear displacements with an error <=20 pm has been developed. The remarkable accuracy of this interferometer is achieved through a design that includes (1) a wavefront split that reduces (relative to amplitude splits used in other interferometers) self interference and (2) a common-optical-path configuration that affords common-mode cancellation of the interference effects of thermal-expansion changes in optical-path lengths. The most popular method of displacement- measuring interferometry involves two beams, the polarizations of which are meant to be kept orthogonal upstream of the final interference location, where the difference between the phases of the two beams is measured. Polarization leakages (deviations from the desired perfect orthogonality) contaminate the phase measurement with periodic nonlinear errors. In commercial interferometers, these phase-measurement errors result in displacement errors in the approximate range of 1 to 10 nm. Moreover, because prior interferometers lack compensation for thermal-expansion changes in optical-path lengths, they are subject to additional displacement errors characterized by a temperature sensitivity of about 100 nm/K. Because the present interferometer does not utilize polarization in the separation and combination of the two interfering beams and because of the common-mode cancellation of thermal-expansion effects, the periodic nonlinear errors and the sensitivity to temperature changes are much smaller than in other interferometers

Zhao, Feng↗

Data-driven approach to parameterize SCAN + U for an accurate description of 3 d transition metal oxide thermochemistry

Semilocal density-functional theory (DFT) methods exhibit significant errors for the phase diagrams of transition-metal oxides that are caused by an incorrect description of molecular oxygen and the large self-interaction error in materials with strongly localized electronic orbitals. Empirical and semiempirical corrections based on the DFT + U method can reduce these errors, but the parameterization and validation of the correction terms remains an on-going challenge. Here we develop a systematic methodology to determine the parameters and to statistically assess the results by considering interlinked thermochemical data across a set of transition metal compounds. We consider three interconnected levels of correction terms: (1) a constant oxygen binding correction, (2) Hubbard-U correction, and (3) DFT/DFT + U compatibility correction. The parameterization is expressed as a unified optimization problem. We demonstrate this approach for 3d transition metal oxides, considering a target set of binary and ternary oxides. With a total of 37 measured formation enthalpies taken from the literature, the dataset is augmented by the reaction energies of 1710 unique reactions that were derived from the formation energies by systematic enumeration. To ensure a balanced dataset across the available data, the reactions were grouped by their similarity using clustering and suitably weighted. The parameterization is validated using leave-one-out cross validation (CV), a standard technique for the validation of statistical models. We apply the methodology to the strongly constrained and appropriately normed (SCAN) density functional. Based on the CV score, the error of binary (ternary) oxide formation energies is reduced by 40% (75%) to 0.10 (0.03) eV/atom. A simplified correction scheme that does not involve SCAN/SCAN + U compatibility terms still achieves an error reduction of 30% (25%). The method and tools demonstrated here can be applied to other classes of materials or to parameterize the corrections to optimize DFT + U performance for other target physical properties.

36 MATERIALS SCIENCE↗

Sensitivity of WFIRST Coronagraph Broadband Contrast Performance to DM Actuator Errors

The WFIRST/AFTA 2.4 m space telescope currently under study includes a stellar coronagraph for the imaging and the spectral characterization of extrasolar planets. The coronagraph employs sequential deformable mirrors to compensate for phase and amplitude errors. Using the optical model of an Occulting Mask Coronagraph (OMC) testbed at the Jet Propulsion Laboratory (JPL), we have investigated the sensitivity of a Hybrid Lyot Coronagraph (HLC) broadband contrast performance to DM actuator errors and actuator limits. Considered case include drifts in actuator gains or actuator response curves, paired actuators, as well as the limits imposed by a neighboring-actuator rule. Actual data about the actuator drifts and the knowledge about the paired-actuators obtained in several DM characterization experiments conducted at JPL, as well as the neighboring-actuator rule implemented on the OMC testbed were used in simulations. We obtained good agreement between the model prediction and the testbed measurement in terms of static HLC contrast floor and contrast chromaticity.

Sidick, Erkin↗

Apparatus and Method to Enable Precision and Fast Laser Frequency Tuning

An apparatus and method is provided to enable precision and fast laser frequency tuning. For instance, a fast tunable slave laser may be dynamically offset-locked to a reference laser line using an optical phase-locked loop. The slave laser is heterodyned against a reference laser line to generate a beatnote that is subsequently frequency divided. The phase difference between the divided beatnote and a reference signal may be detected to generate an error signal proportional to the phase difference. The error signal is converted into appropriate feedback signals to phase lock the divided beatnote to the reference signal. The slave laser frequency target may be rapidly changed based on a combination of a dynamically changing frequency of the reference signal, the frequency dividing factor, and an effective polarity of the error signal. Feed-forward signals may be generated to accelerate the slave laser frequency switching through laser tuning ports.

Chen, Jeffrey R.↗