Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PARALLEL OPTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Optical neural engine for solving scientific partial differential equations

Abstract Solving partial differential equations (PDEs) is the cornerstone of scientific research and development. Data-driven machine learning (ML) approaches are emerging to accelerate time-consuming and computation-intensive numerical simulations of PDEs. Although optical systems offer high-throughput and energy-efficient ML hardware, their demonstration for solving PDEs is limited. Here, we present an optical neural engine (ONE) architecture combining diffractive optical neural networks for Fourier space processing and optical crossbar structures for real space processing to solve time-dependent and time-independent PDEs in diverse disciplines, including Darcy flow equation, the magnetostatic Poisson’s equation in demagnetization, the Navier-Stokes equation in incompressible fluid, Maxwell’s equations in nanophotonic metasurfaces, and coupled PDEs in a multiphysics system. We numerically and experimentally demonstrate the capability of the ONE architecture, which not only leverages the advantages of high-performance dual-space processing for outperforming traditional PDE solvers and being comparable with state-of-the-art ML models but also can be implemented using optical computing hardware with unique features of low-energy and highly parallel constant-time processing irrespective of model scales and real-time reconfigurability for tackling multiple tasks with the same architecture. The demonstrated architecture offers a versatile and powerful platform for large-scale scientific and engineering computations.

Tang, Yingheng (ORCID:0009000153622546)↗

On the use of a multiple beam optical sensor for in situ curvature monitoring in liquids

Several methods have been developed since the early 1900 to extract thin film stresses from the curvature of the substrate to which it is attached. One robust method particularly suitable for in situ curvature monitoring is the multiple beam optical sensor, which consists in measuring the change in relative spacings between parallel laser beams reflecting off the curved substrate. Although the technique is already well established for curvature monitoring in low pressure, gaseous environments, its use in liquid media has not yet received similar attention. Moreover, in the majority of the published work so far, spot spacings have been assumed to depend linearly on curvature. In this paper, it is first shown that this assumption may induce significant errors, particularly at large curvature. A more accurate set of equations is proposed. Next, the relationship between spot spacings and curvature is established when the substrate of interest is in a liquid, and a constitutive formula is proposed in that case as well. Finally, some practical aspects of the multiple beam technique for performing curvature measurements in a liquid are discussed. Various factors disturbing the measurement resolution are identified, with a specific interest for thin film anodizing, and a cell design is proposed to minimize their effect.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lab-based Ultrafast Molecular Structure

The proliferation of various laser-driven approaches to sub-picosecond hard X-ray and short-wavelength radiation generation in the past few decades has opened many avenues for the laboratory-based development of traditionally facility-based short wavelength ultrafast molecular structure science. Together with the introduction of microcalorimeter detection schemes, this opens the floodgates to widespread, decentralized implementation of what were until recently specialist short wavelength techniques. A parallel situation exists for the contemporary adoption of sub-wavelength resolution optical microscopies. In what follows, a few ultrafast molecular structure developments and their rationale are briefly recounted.

74 ATOMIC AND MOLECULAR PHYSICS↗

Direct growth of nanocrystalline hexagonal boron nitride films on dielectric substrates

Atomically thin hexagonal-boron nitride (h-BN) films are primarily synthesized through chemical vapor deposition (CVD) on various catalytic transition metal substrates. In this work, a single-step metal-catalyst-free approach to obtain few- to multi-layer nanocrystalline h-BN (NCBN) directly on amorphous SiO{sub 2}/Si and quartz substrates is demonstrated. The as-grown thin films are continuous and smooth with no observable pinholes or wrinkles across the entire deposited substrate as inspected using optical and atomic force microscopy. The starting layers of NCBN orient itself parallel to the substrate, initiating the growth of the textured thin film. Formation of NCBN is due to the random and uncontrolled nucleation of h-BN on the dielectric substrate surface with no epitaxial relation, unlike on metal surfaces. The crystallite size is ∼25 nm as determined by Raman spectroscopy. Transmission electron microscopy shows that the NCBN formed sheets of multi-stacked layers with controllable thickness from ∼2 to 25 nm. The absence of transfer process in this technique avoids any additional degradation, such as wrinkles, tears or folding and residues on the film which are detrimental to device performance. This work provides a wider perspective of CVD-grown h-BN and presents a viable route towards large-scale manufacturing of h-BN substrates and for coating applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical electric fields as wavelength function within active layer of graphene/Si heterojunction solar cell – An analysis

The optical electric field characteristics of graphene/Si heterojunction thin film solar cell as the function of wavelength photons incident have modeled and calculated. There is ITO/TiO{sub 2}/C-Si/TiO{sub 2} device configuration in which p-n junction represented by C-Si and viewed as active layer for excited electrons production. The dependent of such electric field on wavelength can be understood by solving scattering matrix obtained from the interface matrix and layer matrix operation, in this report we have calculated the electric field distribution for several active layer thickness (d{sub AL}) conditions and each of them examined in the cases of x position are equal to zero, half and full of d{sub AL} while for the entire taking into account we used 250 – 840 nm wavelength range. However, this calculation is restricted by idealization assumption such as the complex refraction index is doesn’t change significantly by the thickness in hundred nanometer range, linear optical response described by scalar refraction complex index and the interface are parallel and flat compared to the wavelength of the light.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

One dimensional focusing with high numerical aperture multilayer Laue lens

Multilayer Laue lenses (MLLs) capitalize on the developments in multilayer deposition technologies for fabricating reflective coatings, specifically undertaken for EUV lithography, where layer thicknesses of several nanometers can be achieved. MLLs are deposited layer by layer, with their thicknesses following the zone plate law, and then pieces are sliced and extracted for use in focusing. Rays are reflected in the Laue geometry. The efficiency of a MLL can be very high, and is maximized by making the slice equal to about a half Pendellosung period so that most energy is transferred from the undiffracted to the diffracted beam, and by ensuring that the Bragg condition is met at each point in the zone plate. This latter condition requires that the layers are tilted to the beam by an amount that varies with layer position; e.g. for focusing a collimated beam, the layers should be normal to a cylinder of radius of twice the focal length. We have fabricated such tilted-zone MLLs and find that they exhibit improved efficiency across their entire pupil as compared with parallel-zone MLLs. This leads to a higher effective NA of the optic and hence higher resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Flow-through compression cell for small-angle and ultra-small-angle neutron scattering measurements

In situ measurements of geological materials under compression and with hydrostatic fluid pressure are important in understanding their behavior under field conditions, which in turn provides critical information for application-driven research. In particular, understanding the role of nano- to micro-scale porosity in the subsurface liquid and gas flow is critical for the high-fidelity characterization of the transport and more efficient extraction of the associated energy resources. In other applications, where parts are produced by the consolidation of powders by compression, the resulting porosity and crystallite orientation (texture) may affect its in-use characteristics. Small-angle neutron scattering (SANS) and ultra SANS are ideal probes for characterization of these porous structures over the nano to micro length scales. Here we show the design, realization, and performance of a novel neutron scattering sample environment, a specially designed compression cell, which provides compressive stress and hydrostatic pressures with effective stress up to 60 MPa, using the neutron beam to probe the effects of stress vectors parallel to the neutron beam. In conclusion, we demonstrate that the neutron optics is suitable for the experimental objectives and that the system is highly stable to the stress and pressure conditions of the measurements.

47 OTHER INSTRUMENTATION↗

Quasi-One-Dimensional Polarized Fermi Superfluids

We calculate the zero-temperature (T=0) phase diagram of a polarized two-component Fermi gas in an array of weakly coupled parallel one-dimensional (1D) ''tubes'' produced by a two-dimensional optical lattice. Increasing the lattice strength drives a crossover from three-dimensional (3D) to 1D behavior, stabilizing the Fulde-Ferrell-Larkin-Ovchinnikov (FFLO) modulated superfluid phase. We argue that the most promising regime for observing the FFLO phase is in the quasi-1D regime, where the atomic motion is largely 1D but there is weak tunneling in the other directions that stabilizes long-range order. In the FFLO phase, we describe a phase transition where the quasiparticle spectrum changes from gapless near the 3D regime to gapped in quasi-1D.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-104: An Examination of Dose in the Buildup and Build-Down Regions

Purpose: To examine dose in the buildup and build-down regions and compare measurements made with various models and dosimeters Methods: Dose was examined in a 30×30cm {sup 2} phantom of water-equivalent plastic with 10cm of backscatter for various field sizes. Examination was performed with radiochromic film and optically-stimulated-luminescent-dosimeter (OSLD) chips, and compared against a plane-parallel chamber with a correction factor applied to approximate the response of an extrapolation chamber. For the build-down region, a correction factor to account for table absorption and chamber orientation in the posterior-anterior direction was applied. The measurement depths used for the film were halfway through their sensitive volumes, and a polynomial best fit curve was used to determine the dose to their surfaces. This chamber was also compared with the dose expected in a clinical kernel-based computer model, and a clinical Boltzmann-transport-equation-based (BTE) computer model. The two models were also compared against each other for cases with air gaps in the buildup region. Results: Within 3mm, all dosimeters and models agreed with the chamber within 10% for all field sizes. At the entrance surface, film differed in comparison with the chamber from +90% to +15%, the BTE-model by +140 to +3%, and the kernel-based model by +20% to −25%, decreasing with increasing field size. At the exit surface, film differed in comparison with the chamber from −10% to −15%, the BTE-model by −53% to −50%, the kernel-based model by −55% to −57%, mostly independent of field size. Conclusion: The largest differences compared with the chamber were found at the surface for all field sizes. Differences decreased with increasing field size and increasing depth in phantom. Air gaps in the buildup region cause dose buildup to occur again post-gap, but the effect decreases with increasing phantom thickness prior to the gap.

60 APPLIED LIFE SCIENCES↗

Search for optical bursts from the gamma ray burst source GBS 0526-66

Attempts were made to detect optical bursts from the gamma-ray burst source GBS 0526-66 during Dec. 31, 1984 to Jan. 2, 1985 and Feb. 23 to Feb. 24, 1985, using the one meter reflector of the Kavalur Observatory. Jan. 1, 1985 coincided with the zero phase of the predicted 164 day period of burst activity from the source (Rothschild and Lingenfelter, 1984). A new optical burst photon counting system with adjustable trigger threshold was used in parallel with a high speed photometer for the observations. The best time resolution was 1 ms and maximum count rate capability was 255,000 counts s(-1). Details of the instrumentation and observational results are presented.

Seetha, S.↗

Dense gas and HII regions in the starburst galaxy NGC 253

The energetic activity in the nuclear barred region of NGC 253 is attributable to a burst of star formation. NGC 253 is in many ways a twin of the prototypical starburst galaxy M82; the strong non-thermal radio continuum, high far-infrared luminosity, and bright molecular emission of the central 1 Kpc parallel the morphology of the M82 starburst. Furthermore, the filamentary low ionization optical emission and extended x ray emission along the minor axis in NGC 253 is similar to a scaled down version of the well developed galactic bipolar wind in M82. The infrared luminosity of NGC 253, 3(exp 10) solar luminosity, is comparable to M82 but is emitted from a smaller region (Telesco and Harper 1980). This suggests that the NGC 253 starburst may be more intense and at an earlier evolutionary stage than M82. However, the presence of a non-stellar AGN in NGC 253 may complicate the comparison (Turner and Ho, 1985). Researchers used the Hat Creek millimeter interferometer to map emission from the J = 1 to 0 transitions of HCN and HCO(+) as well as 3 mm continuum emission, toward the nuclear region of NGC 253. The HCO(+) and continuum observations are sensitive to spatial scales from 6 to 45 seconds. The 2 minute field of view comfortably includes the entire starburst region (about 40 seconds; 650 pc). Because the longer baseline HCN observations are not yet complete, they are only sensitive to spatial scales from 15 to 45 seconds.

Carlstrom, J. E.↗

Ultraviolet Galaxy Counts From STIS Observations of The Hubble Deep Fields

We present galaxy counts in the near and far ultraviolet (NUV and FUV) obtained from Space Telescope Imaging Spectrograph (STIS) observations of portions of the Hubble Deep Field North, (HDFN), the Hubble Deep Field South, (HDFS) and a parallel field near the HDFN. All three fields have deep (AB>29) optical imaging, and we determine magnitudes by taking the ultraviolet flux detected within the limiting optical isophote. An analysis of the UV-optical colors of detected objects, combined with a visual inspection of the UV images, indicates that there are no detectable objects in the UV images which are not also detected in the optical. We measure the detection area and completeness as a function of magnitude by taking the size-magnitude distribution of galaxies in the entire HDFN WFPC2 V+I image, applying the measured UV-optical colors from the detected galaxies, and determining the total area over which each galaxy would have been detected in the UV images. The average area for the simulated galaxies in each UV magnitude bin, (including galaxies which would not be detected at all), provides the effective area and completeness for the bin. We test this procedure with Monte Carlo simulations. The galaxy counts reach to AB=29 in both the NUV and FUV; 1 magnitude fainter than the HDF F30OW counts, and 7 magnitudes fainter than balloon-based counts. We compare our measured counts to various models.

Gardner, J. P.↗

Recent advances in automatic alignment system for the National Iginition Facility

The automatic alignment system for the National Ignition Facility (NIF) is a large-scale parallel system that directs all 192 laser beams along the 300-m optical path to a 50-micron focus at target chamber in less than 50 minutes. The system automatically commands 9,000 stepping motors to adjust mirrors and other optics based upon images acquired from high-resolution digital cameras viewing beams at various locations. Forty-five control loops per beamline request image processing services running on a LINUX cluster to analyze these images of the beams and references, and automaticallys teer the beams toward the target. This paper discusses the upgrades to the NIF automatic alignment system to handle new alignment needs and evolving requirements as related to various types of experiments performed. As NIF becomes a continuously-operated system and more experiments are performed, performance monitoring is increasingly important for maintenance and commissioning work. Data, collected during operations, is analyzed for tuning of the laser and targeting maintenance work. handling evolving alignment and maintenance needs is expected for the planned 30-year operational life of NIF.

42 ENGINEERING↗

Picosecond Dynamical Response to a Pressure-Induced Break of the Tertiary Structure Hydrogen Bonds in a Membrane Chromoprotein

In this work, we used elastic incoherent neutron scattering (EINS) to find out if structural changes accompanying local hydrogen bond rupture are also reflected in global dynamical response of the protein complex. Chromatophore membranes from LH2-only strains of the photosynthetic bacterium Rhodobacter sphaeroides, with spheroidenone or neurosporene as the major carotenoids, were subjected to high hydrostatic pressure at ambient temperature. Optical spectroscopy conducted at high pressure confirmed rupture of tertiary structure hydrogen bonds. In parallel, we used EINS to follow average motions of the hydrogen atoms in LH2, which reflect the flexibility of this complex. A decrease of the average atomic mean square displacements of hydrogen atoms was observed up to a pressure of 5 kbar in both carotenoid samples due to general stiffening of protein structures, while at higher pressures a slight increase of the displacements was detected in the neurosporene mutant LH2 sample only. These data reflect a correlation between the local pressure-induced breakage of H-bonds, observed in optical spectra, with the altered protein dynamics monitored by EINS. The slightly higher compressibility of the neurosporene mutant sample shows that even subtle alterations of carotenoids are manifested on a larger scale and emphasize a close connection between the local structure and global dynamics of this membrane protein complex.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of magnetostatic interactions on the magnetization reversal of patterned magnetic elements

The magnetization reversal in patterned thin-film arrays of elliptical submicron permalloy elements has been investigated by magnetic-force microscopy and micro-magneto-optic Kerr effect. Three different spatial arrangements of chains are considered, namely chains aligned parallel to the long axis of the ellipse, chains aligned parallel to the short axis of the ellipse, and arrays with roughly equal element-to-element spacings in both directions. Comparison of the hysteresis loops in an in-plane field perpendicular to the ellipses' long axes shows that the magnetization reversibility is highest for chains along the long axis. This is due to the nearly coherent magnetization rotation in the applied magnetic field and to the formation of a head-to-tail domain arrangement. Other arrangements, such as chains of ellipses aligned parallel to short axis, yield flux-closure domains as the applied magnetic field is changed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Luneburg lens and optical matrix algebra research

Planar, as opposed to channelized, integrated optical circuits (IOCs) were stressed as the basis for computational devices. Both fully-parallel and systolic architectures are considered and the tradeoffs between the two device types are discussed. The Kalman filter approach is a most important computational method for many NASA problems. This approach to deriving a best-fit estimate for the state vector describing a large system leads to matrix sizes which are beyond the predicted capacities of planar IOCs. This problem is overcome by matrix partitioning, and several architectures for accomplishing this are described. The Luneburg lens work has involved development of lens design techniques, design of mask arrangements for producing lenses of desired shape, investigation of optical and chemical properties of arsenic trisulfide films, deposition of lenses both by thermal evaporation and by RF sputtering, optical testing of these lenses, modification of lens properties through ultraviolet irradiation, and comparison of measured lens properties with those expected from ray trace analyses.

Wood, V. E.↗

Optical Forces on an Oscillating Dipole Near VO2 Phase Transition

We investigate optical forces on oscillating dipoles close to a phase change vanadium dioxide (VO2) film, which exhibits a metal-insulator transition around 340 K and low thermal hysteresis. This configuration emulates the interaction between an illuminated nanosphere and an interface and we employ a classical description to capture its important aspects. We consider both electric and magnetic dipoles for two different configurations, namely with the dipole moments parallel and perpendicular to the VO2 film. By using Bruggeman theory to describe the effective optical response of the material, we show that the thermal hysteresis present in the VO2 transition clearly shows up in the behavior of optical forces. In the near-field regime, the force on both dipoles can change from attractive to repulsive just by heating (or cooling) the film for a selected frequency range. We also verified that the optical forces are comparable to the Casimir-Polder force in a similar system, revealing the possibility of modulating or even changing the sign of the resultant force on an illuminated nano-object due to the presence of a thermochromic material. We hope that this work contributes to set the grounds for alternative approaches to control light-matter interactions using phase-change materials.

36 MATERIALS SCIENCE↗

TH-AB-202-11: Spatial and Rotational Quality Assurance of 6DOF Patient Tracking Systems

Purpose: External tracking systems used for patient positioning and motion monitoring during radiotherapy are now capable of detecting both translations and rotations (6DOF). In this work, we develop a novel technique to evaluate the 6DOF performance of external motion tracking systems. We apply this methodology to an infrared (IR) marker tracking system and two 3D optical surface mapping systems in a common tumor 6DOF workspace. Methods: An in-house designed and built 6DOF parallel kinematics robotic motion phantom was used to follow input trajectories with sub-millimeter and sub-degree accuracy. The 6DOF positions of the robotic system were then tracked and recorded independently by three optical camera systems. A calibration methodology which associates the motion phantom and camera coordinate frames was first employed, followed by a comprehensive 6DOF trajectory evaluation, which spanned a full range of positions and orientations in a 20×20×16 mm and 5×5×5 degree workspace. The intended input motions were compared to the calibrated 6DOF measured points. Results: The technique found the accuracy of the IR marker tracking system to have maximal root mean square error (RMSE) values of 0.25 mm translationally and 0.09 degrees rotationally, in any one axis, comparing intended 6DOF positions to positions measured by the IR camera. The 6DOF RSME discrepancy for the first 3D optical surface tracking unit yielded maximal values of 0.60 mm and 0.11 degrees over the same 6DOF volume. An earlier generation 3D optical surface tracker was observed to have worse tracking capabilities than both the IR camera unit and the newer 3D surface tracking system with maximal RMSE of 0.74 mm and 0.28 degrees within the same 6DOF evaluation space. Conclusion: The proposed technique was effective at evaluating the performance of 6DOF patient tracking systems. All systems examined exhibited tracking capabilities at the sub-millimeter and sub-degree level within a 6DOF workspace.

60 APPLIED LIFE SCIENCES↗