Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optics and Optical Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Design and implementation of a portable diagnostic system for Thomson scattering and optical emission spectroscopy measurements

A diagnostic system, which has a design goal of high-portability, has been designed at Oak Ridge National Laboratory (ORNL). This project aims at providing measurements of key plasma parameters (ne, Te, ni, Ti) for fusion-relevant devices, utilizing Thomson scattering (TS) and optical emission spectroscopy (OES). The innovative design employs mostly commercial off-the-shelf instrumentation and a traveling team of researchers to conduct measurements at various magnetic-confinement plasma devices. The TS diagnostic uses a Quantel Q-smart 1500 Nd:YAG laser with a 2ω harmonic generator to produce up to 850 mJ of 532 nm laser pulses at 10 Hz. Collection optics placed at the detection port consists of an 11 × 3 optical fiber bundle, where the TS diagnostic uses an 11 × 1 subset array of the fibers, the OES diagnostic uses another 11 fibers, and the remaining fibers are available to the host institution. The detection system is comprised of two separate IsoPlane-320 spectrometers with triple-grating turrets of various line spacing and two PI-MAX 4 intensified CCD detectors, used simultaneously to measure a broad range of ion, impurity, and electron parameters. The self-contained diagnostic package also includes a data processing and storage system. The design and initial implementation of the TS-OES diagnostic system are described. The experiments from the proof-of-principle operation of the portable package on a high density (∼2.5 × 1022 m−3) and low-temperature (∼5 eV) electrothermal arc source at ORNL are also discussed.

Kafle, N. (ORCID:000000028144787X)↗

Bicep/Keck XV: The Bicep3 Cosmic Microwave Background Polarimeter and the First Three-year Data Set

Abstract We report on the design and performance of the B icep3 instrument and its first three-year data set collected from 2016 to 2018. B icep3 is a 52 cm aperture refracting telescope designed to observe the polarization of the cosmic microwave background (CMB) on degree angular scales at 95 GHz. It started science observation at the South Pole in 2016 with 2400 antenna-coupled transition-edge sensor bolometers. The receiver first demonstrated new technologies such as large-diameter alumina optics, Zotefoam infrared filters, and flux-activated SQUIDs, allowing ∼10× higher optical throughput compared to the Keck design. B icep3 achieved instrument noise equivalent temperatures of 9.2, 6.8, and 7.1 μ K CMB s and reached Stokes Q and U map depths of 5.9, 4.4, and 4.4 μ K arcmin in 2016, 2017, and 2018, respectively. The combined three-year data set achieved a polarization map depth of 2.8 μ K arcmin over an effective area of 585 square degrees, which is the deepest CMB polarization map made to date at 95 GHz.

79 ASTRONOMY AND ASTROPHYSICS↗

Cloud Condensation Nuclei and Printed Optical Particle Spectrometer Measurements at Mt. Soledad during EPCAPE 2023-24

These measurements are provided by a differential mobility analyzer operated as a scanning mobility particle sizer, a printed particle optical spectrometer (POPS), and a continuous flow diffusion cloud condensation nuclei (CCN) counter. The instruments sample from either a counterflow virtual impactor inlet or an isokinetic inlet. The measurements provide the mobility aerosol size distribution (30-360 nm), optical size distribution (150 - 6000 nm), size-resolved CCN distribution (30-360 nm) at 0.2, 0.4, 0.6, 0.8, and 1.0% supersaturation. CCN measurements are performed in denuded and undenuded configuration, where denuded refers to the removal of low molecular weight organic vapors. A detailed NetCDF header is included with the datafiles. Users of these measurements are encouraged to consult with the authors about appropriate interpretation before submitting for publication, offering coauthorship where appropriate.

54 ENVIRONMENTAL SCIENCES↗

Testing the optical components for the National Ignition Facility time-resolved soft x-ray opacity spectrometer (OpSpecTR)

Opacity measurements are being carried out at the Z-facility at Sandia National Laboratories and at the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. The current soft x-ray Opacity Spectrometer (OpSpec) used on the NIF uses two elliptically bent crystals in time-integrated mode on either an image plate or a film. Plans are under way to expand these opacity measurements into a mode of time-resolved detection, called OpSpecTR. Previously, considerations for the available hCMOS detector size and photometrics led to a crystal geometry redesign and the use of a grazing angle x-ray mirror. The mirror acts as a low-pass x-ray energy filter, reducing the contribution of higher energy x rays. The first tests of the mirror and the crystal for OpSpecTR are presented here. The size of the mirror reflection and the reflectivity is tested using a Manson x-ray source. The mirror coupled with the new elliptical crystal shape demonstrates OpSpecTR’s spectral coverage. Finally, the results from the x-ray optics performance testing are shown along with the intended design.

47 OTHER INSTRUMENTATION↗

Fabrication Development for SPT-SLIM, a Superconducting Spectrometer for Line Intensity Mapping

Line Intensity Mapping (LIM) is a new observational technique that uses low-resolution observations of line emission to efficiently trace the large-scale structure of the Universe out to high redshift. Common mm/sub-mm emission lines are accessible from ground-based observatories, and the requirements on the detectors for LIM at mm-wavelengths are well matched to the capabilities of large-format arrays of superconducting sensors. We describe the development of an R = lambda/Delta lambda = 300 on-chip superconducting filter-bank spectrometer covering the 120-180 GHz band for future mm-LIM experiments, focusing on SPT-SLIM, a pathfinder LIM instrument for the South Pole Telescope. Radiation is coupled from the telescope optical system to the spectrometer chip via an array of feedhorn-coupled orthomode transducers. Superconducting microstrip transmission lines then carry the signal to an array of channelizing half-wavelength resonators, and the output of each spectral channel is sensed by a lumped element kinetic inductance detector (leKID). Key areas of development include incorporating new low-loss dielectrics to improve both the achievable spectral resolution and optical efficiency and development of a robust fabrication process to create a galvanic connection between ultra-pure superconducting thin-films to realize multi-material (hybrid) leKIDs. We provide an overview of the spectrometer design, fabrication process, and prototype devices.

microstrip resonators↗

Effects of Molecular Size on Resolution in Charge Detection Mass Spectrometry

Instrumental resolution of Fourier transform-charge detection mass spectrometry instruments with electrostatic ion trap detection of individual ions depends on the precision with which ion energy is determined. Energy can be selected using ion optic filters or from harmonic amplitude ratios (HARs) that provide Fellgett’s advantage and eliminate the necessity of ion transmission loss to improve resolution. Unlike the ion energy-filtering method, the resolution of the HAR method increases with charge (improved S/N) and thus with mass. An analysis of the HAR method with current instrumentation indicates that higher resolution can be obtained with the HAR method than the best resolution demonstrated for instruments with energy-selective optics for ions in the low MDa range and above. However, this gain is typically unrealized because the resolution obtainable with molecular systems in this mass range is limited by sample heterogeneity. Here, this phenomenon is illustrated with both tobacco mosaic virus (0.6–2.7 MDa) and AAV9 (3.7–4.7 MDa) samples where mass spectral resolution is limited by the sample, including salt adducts, and not by instrument resolution. Nevertheless, the ratio of full to empty AAV9 capsids and the included genome mass can be accurately obtained in a few minutes from 1× PBS buffer solution and an elution buffer containing 300+ mM nonvolatile content despite extensive adduction and lower resolution. Empty and full capsids adduct similarly indicating that salts encrust the complexes during late stages of droplet evaporation and that mass shifts can be calibrated in order to obtain accurate analyte masses even from highly salty solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pre-commissioning of the wide-dynamic range halo monitor to be installed in the Fermilab MI-8 line

The beam halo can contribute to beam losses in accelerators and is very difficult to measure. With an increase in beam intensity following the PIP-II upgrade at Fermilab, the beam losses are expected to be higher with some coming from beam halo. Therefore, it is important to measure the sources of beam halo to minimize the beam losses. A modified Halo Monitor developed by J-PARC will be installed in Fermilab MI-8 transfer line to measure the beam halo. In this paper, an update on the beam profile monitor fabrication is covered. The updates include the location selection for the Halo Monitor in the MI-8 transfer line, shielding options for instrumentation, initial testing of equipment, and ray tracing simulations for the Offner optics and the targets used in the monitor.

Babacan, Betiay [IIT, Chicago; Fermilab]↗

Smart Adhesive Joint with High-Definition Fiber-Optic Sensing for Automotive Applications

Structural health monitoring of fiber-reinforced composite-based joints for automotive applications during their manufacturing and on-demand assessment for its durability in working environments is critically needed. High-definition fiber-optic sensing is an effective method to measure internal strain/stress development using minimally invasive continuous sensors. The sensing fiber diameters are in the same order of magnitude when compared to reinforcement (glass, basalt, or carbon fibers) used in polymer composites. They also offer a unique ability to monitor the evolution of residual stresses after repeated thermal exposure with varying temperatures for automotive components/joints during painting using an electrophoretic painting process. In this paper, a high-definition fiber-optic sensor utilizing Rayleigh scattering is embedded within an adhesive joint between a carbon fiber-reinforced thermoset composite panel and an aluminum panel to measure spatially resolved strain development, residual strain, and thermal expansion properties during the electrophoretic paint process-simulated conditions. The strain measured by the continuous fiber-optic sensor was compared with an alternate technique using thermal digital image correlation. The fiber-optic sensor was able to identify the spatial variation of residual strains for a discontinuous carbon fiber-reinforced composite with varying local fiber orientations and resin content.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

All-purpose, all-sky photometric redshifts for the Legacy Imaging Surveys Data Release 8

ABSTRACT In this paper, we present photometric redshift (photo-z) estimates for the Dark Energy Spectroscopic Instrument (DESI) Legacy Imaging Surveys, currently the most sensitive optical survey covering the majority of the extragalactic sky. Our photo-z methodology is based on a machine-learning approach, using sparse Gaussian processes augmented with Gaussian mixture models (GMMs) that allow regions of parameter space to be identified and trained separately in a purely data-driven way. The same GMMs are also used to calculate cost-sensitive learning weights that mitigate biases in the spectroscopic training sample. By design, this approach aims to produce reliable and unbiased predictions for all parts of the parameter space present in wide area surveys. Compared to previous literature estimates using the same underlying photometry, our photo-zs are significantly less biased and more accurate at z > 1, with negligible loss in precision or reliability for resolved galaxies at z < 1. Our photo-z estimates offer accurate predictions for rare high-value populations within the parent sample, including optically selected quasars at the highest redshifts (z > 6), as well as X-ray or radio continuum selected populations across a broad range of flux (densities) and redshift. Deriving photo-z estimates for the full Legacy Imaging Surveys Data Release 8, the catalogues provided in this work offer photo-z estimates predicted to be of high quality for ≳9 × 108 galaxies over ${\sim}19\, 400\, \text{deg}^{2}$ and spanning 0 < z ≲ 7, offering one of the most extensive samples of redshift estimates ever produced.

79 ASTRONOMY AND ASTROPHYSICS↗

Hurtado summer 2025 REDWOODS PWFS code

This release includes code developed by Benjamin Gerard and Joel Hurtado in summer 2025 to model the performance of different modes of the reflective three-sided pyramid wavefront sensor instrument within the REDWOODS module of the Shane Adaptive Optics system at Lick observatory.

Gerard, BenjaminL [Lawrence Livermore National Lab↗

Holographic Lithography for Industrial Nanomanufacturing

The participant constructed interference lithography experiments on their prototype of a coordinated holographic industrial-scale electromagnetic lithography (CHISEL) tool. These experiments involved generating several laser beams and interfering them in photosensitive materials, whereupon subsequent development resulted in micro- and nano-structured samples. We characterized these samples using scanning electron microscopy and various optical interrogation methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fiber optic sensing for strain and temperature

Fiber optic sensing for strain and temperature. This presentation reports the status of the R&D work performed at FNAL on a novel diagnostic tool for superconducting magnet based on fiber optics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SDSS-IV MaNGA: Modeling the Spectral Line-spread Function to Subpercent Accuracy

The Sloan Digital Sky Survey IV Mapping Nearby Galaxies at APO (MaNGA) program has been operating from 2014 to 2020, and has now observed a sample of 9269 galaxies in the low redshift universe (z ∼ 0.05) with integral-field spectroscopy. With rest-optical (λλ0.36–1.0 μm) spectral resolution R ∼ 2000 the instrumental spectral line-spread function (LSF) typically has 1σ width of about 70 km s{sup −1}, which poses a challenge for the study of the typically 20–30 km s{sup −1} velocity dispersion of the ionized gas in present-day disk galaxies. In this contribution, we present a major revision of the MaNGA data pipeline architecture, focusing particularly on a variety of factors impacting the effective LSF (e.g., under-sampling, spectral rectification, and data cube construction). Through comparison with external assessments of the MaNGA data provided by substantially higher-resolution R ∼ 10,000 instruments, we demonstrate that the revised MPL-10 pipeline measures the instrumental LSF sufficiently accurately (≤0.6% systematic, 2% random around the wavelength of Hα) that it enables reliable measurements of astrophysical velocity dispersions σ {sub Hα} ∼ 20 km s{sup −1} for spaxels with emission lines detected at signal-to-noise ratio > 50. Velocity dispersions derived from [O II], Hβ, [O III], [N II], and [S II] are consistent with those derived from Hα to within about 2% at σ {sub Hα} > 30 km s{sup −1}. Although the impact of these changes to the estimated LSF will be minimal at velocity dispersions greater than about 100 km s{sup −1}, scientific results from previous data releases that are based on dispersions far below the instrumental resolution should be reevaluated.

47 OTHER INSTRUMENTATION↗

A Joint Search for the Electromagnetic Counterpart to the Gravitational-Wave Binary Black-Hole Merger Candidate S250328ae with the Dark Energy Camera and the Prime Focus Spectrograph

The first detection of an optical counterpart to a gravitational wave signal revealed that collaborative efforts between instruments with different specializations provide a unique opportunity to acquire impactful multi-messenger data. We present results of such a joint search with the Dark Energy Camera (DECam) and Prime Focus Spectrograph (PFS) for the optical counterpart of the LIGO-Virgo-KAGRA event S250328ae, a binary black hole merger candidate of high significance detected at a distance of 511$\pm$82 Mpc and localized within an area of 3 (15) square degrees at 50% (90%) confidence. We observed the 90% confidence area with DECam and identified 36 high-confidence transient candidates after image processing, candidate selection, and candidate vetting. We observed with PFS to obtain optical spectra of DECam candidates, Swift-XRT candidates, and potential host galaxies of S250328ae. In total, 3897 targets were observed by seven pointings covering ~50% of the 90% confidence area. After template fitting and visual inspection, we identified 12 SNe, 159 QSOs, 2975 galaxies, and 131 stars. With the joint observations of DECam and PFS, we found variability in 12 SNe, 139 QSOs, 37 galaxies, and 2 stars. We do not identify any confident optical counterparts, though the association is not ruled out for three variable candidates that are not observed by PFS and 6 QSO candidates without clear variability if the optical counterpart of S250328ae is faint. Despite the lack of confident optical counterparts, this paper serves as a framework for future collaborations between wide-field imagers and multi-object spectrographs to maximize multi-messenger analyses.

Zhang, Haibin [Natl. Astron. Observ. of Japan] (OR↗

Strobed imaging as a method for the determination and diagnosis of local seeing

ABSTRACT The image quality budget of many telescopes can have substantial contributions from local seeing, both ‘mirror’ and ‘dome’, which arise from turbulence and temperature variations that are difficult to quantify, measure directly, and ameliorate. We describe a method to determine the ‘local’ seeing degradation due to wavefront perturbations within the final few metres of the optical path from celestial sources to the focal plane of a ground-based telescope, using the primary instrument and along the same path taken by light from celestial sources. The concept involves placing strobed emitters along the light path to produce images on the main focal plane that ‘freeze’ different realizations of index perturbations. This method has the advantage of measuring directly the image motion and scintillation imparted by the dynamic spatial and temporal structure of local perturbations in the index of refraction along the light path, with a clean separation from seeing induced in the atmosphere above the dome. The strobed-source approach allows for rapid image motion and scintillation to be measured directly on the focal plane, even for large-aperture telescopes with wide-field instruments and slow shutters, such as that being constructed for the Rubin Observatory. A conceptual design is presented that uses the ‘guider’ CCDs in the Rubin telescope focal plane to make local-seeing measurements on demand, perhaps even during science exposures.

79 ASTRONOMY AND ASTROPHYSICS↗

Intercomparison of airborne and surface-based measurements during the CLARIFY, ORACLES and LASIC field experiments

Data are presented from intercomparisons between two research aircraft, the FAAM BAe-146 and the NASA Lockheed P3, and between the BAe-146 and the surface-based DOE (Department of Energy) ARM (Atmospheric Radiation Monitoring) Mobile Facility at Ascension Island (8 S, 14.5W, a remote island in the mid-Atlantic). These took place from 17 August to 5 September 2017, during the African biomass burning season. The primary motivation was to give confidence in the use of data from multiple platforms with which to evaluate numerical climate models. The three platforms were involved in the CLouds-Aerosol-Radiation Interaction and Forcing for Year 2017 (CLARIFY-2017), ObseRvations of Aerosols above CLouds and their intEractionS (ORACLES), and Layered Atlantic Smoke and Interactions with Clouds (LASIC) field experiments. Comparisons from flight segments on six days where the BAe-146 flew alongside the ARM facility on Ascension Island are presented, along with comparisons from wing-tip to wing-tip flight of the P3 and BAe-146 on 18 th August 2017. The intercomparison flight sampled a relatively clean atmosphere overlying a moderately polluted boundary layer, while the 6 fly-bys of the ARM site sampled both clean and polluted conditions 2–4 km upwind. We compare and validate characterisations of aerosol physical, chemical, and optical properties, atmospheric radiation, and cloud microphysics between platforms. We assess the performance of measurement instrumentation in the field, under conditions where sampling conditions are not tightly controlled as in laboratory measurements where calibrations are performed. Solar radiation measurements compared well between airborne platforms. Optical absorption coefficient measurements compared well across all three platforms, even though absolute magnitudes were often low (< 10 Mm -1 ) and close to the sensitivity limits of measurement instrumentation thereby confounding assessments of the comparability of absorption Ångström exponent characterisations. Aerosol absorption measurements from airborne platforms were more comparable than aircraft-to-ground observations. Scattering coefficient observations compared well between airborne platforms, but agreement with ground-based measurements was worse, potentially caused by small differences in sampling conditions or actual aerosol population differences. Chemical composition measurements followed a similar pattern, with better comparisons between the airborne platforms. Thermodynamics, aerosol, and cloud microphysical properties generally compared well.

54 ENVIRONMENTAL SCIENCES↗

High-Spectral Resolution Lidar (HSRL) Instrument Handbook

High-spectral-resolution lidar (HSRL) systems provide vertical profiles of optical depth, backscatter cross-section, depolarization, and backscatter phase function. All HSRL measurements are calibrated by reference to molecular scattering, which is measured at each point in the lidar profile. Like the Raman lidar (RL), but unlike simple backscatter lidars such as the micropulse lidar (MPL), this enables the HSRL to measure backscatter cross-sections and optical depths without prior assumptions about the scattering properties of the atmosphere. The depolarization observations allow robust discrimination between ice and water clouds. Rigorous error estimates can be computed for all measurements. A very narrow angular field of view reduces multiple scattering contributions. The small field of view, coupled with a narrow optical bandwidth, nearly eliminates noise due to scattered sunlight. The laser transmitter is a diode-pumped, frequency-doubled Nd:YAG laser. Narrow-band, single-frequency operation is provided by injection seeding with a single-frequency, cw-diode-pumped diode laser. The main laser cavity is maintained in resonance with the seed laser by adjusting the cavity length to minimize the time between the Q-switch trigger and the emission of the laser pulse. The emission wavelength is tuned via temperature control of the seed laser crystal and is locked to line #1109 of the iodine absorption spectra. Locking is accomplished by minimizing the transmission through a 2-cm-long iodine absorption cell. Use of a high-repetition-rate laser and expansion of the transmitted beam through a 400-mm telescope reduces the transmitted energy density to eye-safe levels. It is possible to look directly into the output beam without hazard. The receiver and transmitter use the same afocal telescope, simplifying the maintenance of stable alignment of the transmitter and receiver although the angular FOV is only 100 μrad. The small FOV and the 4-kHz repetition rate also limit the near-field signal strength, making it possible to record continuous profiles that start at an altitude of ~100 m and extend to 30 km using photon counting detectors. The small FOV also suppresses multiple scattering contributions.

54 ENVIRONMENTAL SCIENCES↗