Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Occupant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Correlating and Simulating Socio-Demographically Driven Residential End-Use Activity Schedules

Incorporating socio-demographic and behavioral considerations into decision-support tools is crucial for identifying gaps and addressing consumer needs to ensure reliable and affordable energy solutions. In energy simulation models, the correlation between socio-demographics and time-use behavior is not well-captured. Thus, we developed a large-scale simulation workflow to generate schedules for 10 residential activities across 24 population segments defined by age, income, and employment status. Using pre-pandemic 2015-2019 American Time Use Survey (ATUS) data, we used ANOVA to confirm the correlation between demographic factors and time use. We explored three k-modes clustering methods-backward, forward, and a new hybrid approach-to delineate the occupancy patterns based on demographics. Using the probability of cluster membership for each population segment and a time inhomogeneous Markov chain to generate activity transition probabilities for each cluster, we simulated 50,000 schedules per segment and validated them against the ATUS data. The hybrid method produced the most socio-demographically differentiated clusters while demonstrating comparable performance to other approaches, with an overall root mean square error of 0.12 for both weekday and weekend schedules. Thus, the hybrid method, where each cluster is dominated by certain demographic segments and occupancy patterns, offers more modeling versatility in terms of scenario analysis. The new workflow improves the socio demographic differentiation of energy consumption by considering differences in time use. This approach enables future research on demographically segmented time of use (TOU) energy consumption, including impacts of TOU utility bills and rate analysis, long-run marginal emissions, and energy retrofits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A systematic review of building energy sufficiency towards energy and climate targets

Among the sufficiency, efficiency, and renewable frameworks for reducing energy use and energy-related carbon emissions, Building Energy Sufficiency (BES) is gaining attention from policy makers and engineers. Despite the significant role of the building sector in the success of national energy and climate plans, there is a lack of research on the drivers, technologies, and effective policy instruments required to achieve BES in the building operational phase. To fill this gap, this study presents a systematic review of the definition and paradigm of BES and concludes that BES should address both occupant demand and energy or emissions requirements simultaneously. The characteristics of occupant demand in building services are divided into four dimensions: time and space, quality and quantity, control and adjustment, and flexibility. Technical options regarding the building architecture, the envelope system, and the building energy system are reviewed. Finally, policy implications and recommendations are discussed. As a result, the multiple benefits and multidisciplinary nature of BES justify further research and accelerated policy implementation in developed and developing countries.

54 ENVIRONMENTAL SCIENCES↗

The impact of simplified window and exhaust fan assumptions on indoor air quality in multifamily buildings

In residential buildings, the indoor air quality can be significantly affected by ventilation measures initiated by occupants, including the operation of windows and in-unit exhaust fans in kitchens and bathrooms. Many simulations simplify these factors by disregarding window opening behaviors and using fixed schedules for exhaust fan operation across all residential units. To estimate the impact of these simplifications in the U.S. context, this study used coupled CONTAM and EnergyPlus models to simulate airflow and contaminant transport in multifamily buildings. The coupled models parametrically varied climate zone, building airtightness, and mechanical ventilation system types. The study conducted a sensitivity analysis on two key occupant behaviors: (1) operating kitchen and bathroom exhausts on different schedules in individual dwelling units, and (2) scheduling open windows on ground and top floors. The simplified assumptions (i.e. uniform in-unit exhaust fan operation and window operation) had a minimal impact on inter-unit air flow and contaminant transport simulations across a broad range of building air leakage and mechanical ventilation system types. These findings suggest that for buildings with tight construction it is reasonable for most modelling and simulation efforts to ignore the effects of non-uniform exhaust fan operation and window opening.

Occupant behavior↗

Using personal monitoring data to derive organ doses for medical radiation workers in the Million Person Study—considerations regarding NCRP Commentary no. 30

The study of low dose and low-dose rate exposure is of central importance in understanding the possible range of health effects from prolonged exposures to radiation. The One Million Person Study of Radiation Workers and Veterans (MPS) of low-dose health effects was designed to evaluate radiation risks among healthy American workers and veterans. The MPS is evaluating low-dose and dose-rate effects, intakes of radioactive elements, cancer and non-cancer outcomes, as well as differences in risks between women and men. Medical radiation workers make up a large group of individuals occupationally exposed to low doses of radiation from external x-ray/gamma exposures. For the MPS, about 100 000 United States medical radiation workers have been selected for study. The approach to the complex dosimetry circumstances for such workers over three to four decades of occupation were initially and broadly described in National Council on Radiation Protection and Measurements (NCRP) Report No. 178. NCRP Commentary No. 30 provides more detail and describes an optimum approach for using personal monitoring data to estimate lung and other organ doses applicable to the cohort and provides specific precautions/considerations applicable to the dosimetry of medical radiation worker organ doses for use in epidemiologic studies. The use of protective aprons creates dosimetric complexity. It is recommended that dose values from dosimeters worn over a protective apron be reduced by a factor of 20 for estimating mean organ doses to tissues located in the torso and that 15% of the marrow should be assumed to remain unshielded for exposure scenarios when aprons are worn. Conversion coefficients relating personal dose equivalent, H p (10) in mSv, to mean absorbed doses to organs and tissues, D T in mGy, for females and males for six exposure scenarios have been determined and presented for use in the MPS. This Memorandum summarises several key points in NCRP Commentary No. 30.

Environmental Sciences & Ecology↗

Electron paramagnetic resonance dose measurements in teeth of tissue donors to the United States Transuranium and Uranium Registries

Abstract The United States Transuranium and Uranium Registries (USTUR) is a research program that studies actinide biokinetics in occupationally exposed individuals with known intakes of these elements. Electron paramagnetic resonance (EPR) in tooth enamel was applied to reconstruct external doses of nine USTUR registrants. Only in two cases there is a reasonable agreement between the EPR-measured dose and the worksite external dose record. For two registrants, high EPR doses can be explained by possible cancer radiotherapy. For the remaining five cases, EPR doses significantly exceed official occupational doses with no plausible explanation for the observed discrepancy. More EPR dose measurements need to be done to explain this anomaly.

Environmental Sciences & Ecology↗

Underlying simplicity of 5f unoccupied electronic structure

Using a simple empirical model based upon the bremsstrahlung isochromat spectroscopy of elemental Th, it is possible to explain the recent high energy resolution fluorescence detection measurements of UF 4 (n = 2) and UCd 11 (n = 3) as well as the new inverse photoelectron spectroscopy of Pu 2 O 3 (n = 5), where n is the 5f occupation number. Furthermore, a critical issue in this analysis is the assumption that the Th 5f states are essentially empty, which will be confirmed both experimentally and computationally. Thus, for 5f systems, this simple model provides a unified and consistent picture of 5f unoccupied density of states in simple, localized systems, as the 5f occupation varies in the early part of the series, for n = 0, 2, 3, and 5.

36 MATERIALS SCIENCE↗

Existence of a Nonzero Worst‐Case ACH for Short‐Term Exposure in Ventilated Indoor Spaces

A well‐ventilated room is essential to reduce the risk of airborne transmission. As such, the scientific community sets minimum limits on ventilation with the idea that increased ventilation reduces pathogen concentration and thus reduces the risk of transmission. In contrast, the upper limit on ventilation is usually determined by human comfort and the need to reduce energy consumption. While average pathogen concentration decreases with increased ventilation, local concentration depends on multiple factors and may not follow the same trend, especially within short exposure times over large separation distances. Here, we show through experiments and high‐fidelity simulations the existence of a worst‐case ventilation where local pathogen concentration increases near the receiving host. This occurs during the type of meetings that were recommended during the pandemic (and in some cases solely authorized) with reduced occupancy adhering to social distancing and short exposure times below 20 minutes. We maintain that for cases of high occupancy and long exposure time, increased ventilation remains necessary.

Construction & Building Technology↗

Approaches for effective negative pressure isolation space control to minimize airborne transmission of contaminants in residential homes

Controlling airborne transmission of contaminants including respired viruses such as SARS-CoV-2 is necessary to protect occupants living in the same house with a contagious person. The effectiveness of interventions requiring minor efforts that create a negative pressure isolation zone (IZ) for a contagious person has yet to be systematically tested for residential homes. In this study, ASHRAE Standard 170, which offers guidance for negative pressure isolation space control in healthcare facilities, was used in developing practical and attainable recommendations for residential single-family homes. The relative effectiveness of several control strategies was evaluated through experimentally conducting 17 different test cases in a manufactured single-family house laboratory. These cases were designed based on various heating, ventilation and air-conditioning (HVAC) operating scenarios, intervention measures including closing the IZ door and/or sealing over supply and return air grilles in the IZ, and utilization of bathroom exhaust or portable window fans for pressure control. Four out of 17 test cases were identified as having the potential for strong containment with adequate depressurization in the IZ. The most effective IZ depressurization was achieved through continuously operating the exhaust fan in the bathroom attached to the IZ, by installing a portable window fan that extracted air out of the IZ, and a portable room air conditioner with the AC unit exhaust duct installed in one of the IZ windows.

Construction & Building Technology↗

Evaluating Thermostats' Deadbands Using HVAC Hardware-In-the-Loop Experiment for Advanced Control Strategies

Smart thermostats have gained significant popularity due to their potential for optimizing energy consumption and enhanced user control while ensuring occupants' comfort. The deadband, also referred to as temperature differential, is defined as the temperature difference between the desired setpoint and upper threshold or lower threshold for the HVAC equipment to turn on. It is a key factor influencing energy efficiency and user satisfaction. This paper presents a comparative analysis of the deadbands of five different smart thermostats, tested with a heat pump, aiming to identify variations in their deadband settings and implications for energy management. The experimental study was conducted using a HVAC hardware-in-theloop (HIL) system that integrates smart thermostats with physical HVAC equipment in a simulated house environment. The study explores the trade-offs between energy efficiency and occupant comfort and highlights how different thermostats participating in demand response event cycle differently based on their deadband settings. The findings offer valuable insights into how selecting the right thermostat or configuring smart thermostat with appropriate deadband settings can be leveraged to enhance demand response capabilities, shift loads effectively and improve operational flexibility in HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lawrence Berkley National Laboratory Building 59

The building management system in Building 59 is monitoring and archiving building-level electricity usage, HVAC and lighting system states (e.g., setpoint, temperature, flow rate, pressure), indoor environmental conditions (air temperature, relative humidity, CO2), on-site weather (air temperature, relative humidity), and especially occupant counts as well as other metrics such as Wi-Fi signal. This dataset could support multiple use cases, such as model predictive control and occupant related demand management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lawrence Berkley National Laboratory Building 59 (Raw)

The building management system in Building 59 is monitoring and archiving building-level electricity usage, HVAC and lighting system states (e.g., setpoint, temperature, flow rate, pressure), indoor environmental conditions (air temperature, relative humidity, CO2), on-site weather (air temperature, relative humidity), and especially occupant counts as well as other metrics such as Wi-Fi signal. This dataset could support multiple use cases, such as model predictive control and occupant related demand management. Raw data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ecobee Donate Your Data 1,000 homes in 2017

This dataset is a subset of the Ecobee Donate Your Data (DYD) dataset. The Ecobee DYD data comprises user-reported metadata (of home and occupant characteristics), and data collected by Ecobee thermostats (reported in 5-minute intervals). Participant data are pulled from the Ecobee servers, and then anonymized to remove any personally identifiable information. This subset selects 1,000 single family homes in four states - California, Texas, New York, and Illinois, and span the entire year of 2017. In addition to the measurements, a metadata JSON file is included to illustrate the high-level contextual information of the dataset. The dataset can be analyzed to understand how a single-family heating, ventilation, and air-conditioning (HVAC) system operates, occupant behavior, and building thermal dynamics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lawrence Berkeley National Lab Building 59

The building management system in Building 59 is monitoring and archiving building-level electricity usage, HVAC and lighting system states (e.g., setpoint, temperature, flow rate, pressure), indoor environmental conditions (air temperature, relative humidity, CO2), on-site weather (air temperature, relative humidity), and especially occupant counts as well as other metrics such as Wi-Fi signal. This dataset could support multiple use cases, such as model predictive control and occupant related demand management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Review of the Use of Wearables in Indoor Environmental Quality Studies and an Evaluation of Data Accessibility from a Wearable Device

An understanding of indoor environmental quality (IEQ) and its effects on occupant well-being can inform building system design and operation. The use of wearables in field studies to collect subjective and objective health performance indicators (HPIs) from a large number of occupants could deliver important improvements in IEQ. To facilitate the use of wearables in IEQ studies, there is a need to identify which HPIs should be collected and to evaluate data accessibility from these devices. To address this issue, a literature review of previous IEQ studies was conducted to identify relationships between different IEQ factors and HPIs, with a focus on HPIs that were collected using wearables. A preliminary assessment of data accessibility from a selected wearable device (Fitbit Versa 2) was performed and documented. The review suggested the need to further investigate and collect sleep quality parameters, heart rate, stress response, as well as subjective ratings of comfort using wearables. The data accessibility assessment revealed issues related to missing data points and data resolution from the examined device. A set of recommendations is outlined to inform future studies.

60 APPLIED LIFE SCIENCES↗

WHISPER: Wireless Home Identification and Sensing Platform for Energy Reduction

Many regions of the world benefit from heating, ventilating, and air-conditioning (HVAC) systems to provide productive, comfortable, and healthy indoor environments, which are enabled by automatic building controls. Due to climate change, population growth, and industrialization, HVAC use is globally on the rise. Unfortunately, these systems often operate in a continuous fashion without regard to actual human presence, leading to unnecessary energy consumption. As a result, the heating, ventilation, and cooling of unoccupied building spaces makes a substantial contribution to the harmful environmental impacts associated with carbon-based electric power generation, which is important to remedy. For our modern electric power system, transitioning to low-carbon renewable energy is facilitated by integration with distributed energy resources. Automatic engagement between the grid and consumers will be necessary to enable a clean yet stable electric grid, when integrating these variable and uncertain renewable energy sources. We present the WHISPER (Wireless Home Identification and Sensing Platform for Energy Reduction) system to address the energy and power demand triggered by human presence in homes. The presented system includes a maintenance-free and privacy-preserving human occupancy detection system wherein a local wireless network of battery-free environmental, acoustic energy, and image sensors are deployed to monitor homes, record empirical data for a range of monitored modalities, and transmit it to a base station. Several machine learning algorithms are implemented at the base station to infer human presence based on the received data, harnessing a hierarchical sensor fusion algorithm. Results from the prototype system demonstrate an accuracy in human presence detection in excess of 95%; ongoing commercialization efforts suggest approximately 99% accuracy. Using machine learning, WHISPER enables various applications based on its binary occupancy prediction, allowing situation-specific controls targeted at both personalized smart home and electric grid modernization opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dose limits for astronauts

Radiation exposures to individuals in space can greatly exceed natural radiation exposure on Earth and possibly normal occupational radiation exposures as well. Consequently, procedures limiting exposures would be necessary. Limitations were proposed by the Radiobiological Advisory Panel of the National Academy of Sciences/National Research Council in 1970. This panel recommended short-term limits to avoid deterministic effects and a single career limit (of 4 Sv) based on a doubling of the cancer risk in men aged 35 to 55. Later, when risk estimates for cancer had increased and were recognized to be age and sex dependent, the NCRP, in Report No. 98 in 1989, recommended a range of career limits based on age and sex from 1 to 4 Sv. NCRP is again in the process of revising recommendations for astronaut exposure, partly because risk estimates have increased further and partly to recognize trends in limiting radiation exposure occupationally on the ground. The result of these considerations is likely to be similar short-term limits for deterministic effects but modified career limits.

Review↗

Using A Guided Interview to Create an Individual Exposure Profile for The Lifetime Surveillance of Astronaut Health (LSAH)

BACKGROUND To support NASA’s Lifetime Surveillance of Astronaut Health (LSAH) project, Individual Exposure Profiles (IEPs) were developed to record an astronaut’s pre-, in-, and post-NASA exposures. NASA astronauts were invited to participate in a one-time guided interview to review known hazard exposures and medical history documented in NASA records and to add new information not otherwise reported. The purpose of the IEP project was to determine if any significant information was gained from these interviews and identify potential trends in long-term health. METHODOLOGY The pre-filled exposure profile data was extracted from several sources including medical records, biographies, and LSAH records. The information that was pre-filled before the interview included occupational exposures prior to selection to the Astronaut Corps, during active astronaut career (e.g., EVA and ground-based training, on-orbit exposures), and after active career. The IEPs also contained relevant medical history (e.g., audiometry, illnesses, injuries) and significant non-occupational exposures. 189 interviews were conducted from 2012-2014. A Microsoft Access database was created to store the information collected in the IEPs before and after the interviews. The database houses the information from the IEPs to track the updates made to the original data. By analyzing which astronauts supplied additional information and which kinds of data were consistently added, potential gaps and trends in missing data may be identified. In designing the database, an efficient structure was implemented for ease of inputting data and to create variables that would generate quantifiable data. Creating standardized variables within the structure helped ease the process of inputting, organizing data, and analyzing data. Additional updates/data were denoted and were categorized by type of update. The categories identified were “Confirmed”, “Confirmed & Supplemented”, “Supplemented”, “Denied”, “Denied & Supplemented”, and “Other”. STATISTICAL ANALYSIS AND RESULTS To assess frequency of exposure updates, descriptive statistics will be generated and stratified by relevant factors such as astronaut selection decade, age at selection, and program/era. Hypothesis testing will be performed to understand the associations between updates to exposure information and population characteristics.

Astronaut health↗

Factors Affecting Override Behavior during Demand Flexibility from High-Resolution Smart Thermostat Data

In this study, we delineate key weather and demographic predictors of override behavior in residential buildings during connected thermostats demand response events. Anticipating and reducing overrides is critical to demand flexibility (DF) program success. We use high- dimensional fixed effects linear regression techniques on a large ecobee dataset for about 5,000 enrolled households in the United States. We identify critical weather (indoor and outdoor temperature), building (housing type), and occupant (previous DF overrides and previous DF event exposure) factors influencing the override patterns of customers during thermostat demand response. We also differentiate DF events by season to understand the different indoor and outdoor conditions that might influence seasonal override rates. We found significant differences in override rates between building types, with single-family semi-detached homes generally having the highest overrides. Having a history of overrides was additionally a critical factor in predicting occupant response to future DF events. Understanding these override differences is necessary for rural electric cooperatives and emerging DF programs without access to large DR historical data. Overall, we provide critical information on technical and local demographic characteristics that may be correlated to building type to influence strategies to reduce overrides and improve the adoption of DF technologies.

connected thermostats (CTs)↗