Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OPTICS DESIGN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Beam Combination for Stellar Imager and its Application to Full-Aperture Imaging

Stellar Imager (SI) will be a Space-Based telescope consisting of 20 to 30 separated apertures. It is designed for UV/Optical imaging of stellar surfaces and asteroseismology. This report describes details of an alternative optical design for the beam combiner, dubbed the Spatial Frequency Remapper (SFR). It sacrifices the large field of view of the Fizeau combiner. In return, spectral resolution is obtained with a diffraction grating rather than an array of energy-resolving detectors. The SFR design works in principle and has been implemented with MIRC at CHARA for a small number of apertures. Here, we show the number of optical surfaces can be reduced and the concept scales gracefully to the large number of apertures needed for Stellar Imager. We also describe a potential application of this spatial frequency remapping to improved imaging with filled aperture systems. For filled-aperture imaging, the SFR becomes the core of an improved aperture masking system. To date, aperture-masking has produced the best images with ground-based telescopes but at the expense of low sensitivity due to short exposures and discarding most of the light collected by the telescope. This design eliminates the light-loss problem previously claimed to be inherent in all aperture-masking designs. We also argue that at least in principle, the short-integration time limit can also be overcome. With these improvements, it becomes an ideal camera for TPF-C; since it can form speckle-free images in the presence of wavefront errors, it should significantly relax the stability requirements of the current designs.

Mozurkewich, D.↗

Nanoparticle using parallel split rings and implementation of chain for creating Fano resonance with polarization independence for energy harvesting in mid-infrared

In optical devices, the polarization of the incident wave affects the Nano particle characteristics. Therefore, designing a polarization-independent device is significant in the process of designing optical structures. On the other hand, the concept of Fano resonance and dark mode has been utilized for achieving more energy enhancement. In this paper, we have developed a symmetrical Nano antenna by employing Fano resonance, which is independent of the incident wave polarization. The proposed Nano antenna is modified in mid infrared regime for biosensing and energy harvesting applications. The designed metamaterial antenna is made by Nano split ring resonators with etched capacitive gaps, which are utilized for concentrating energy. The introduced Nano antenna has a bright and dark mode with a weak enhancement of electric field. The effect of the incident wave polarization is investigated at wave incident angles between 0° and 45° to illustrate the independency of the polarization due to the symmetrical shape of the Nano antenna. In order to trigger the dark mode and enhance the electric field, a Nano chain is incorporated in the final structure. This arrangement has led to increasing of electric field drastically. Furthermore, the figure of merit has been calculated as an advantageous factor in sensing the surrounding materials with various refractive indices. Our findings illustrated that the chain arrangement has caused a peak in the linear form of the extinction cross section of the Nano antenna. This in turn has resulted in the appearance of Fano resonance with no impact on the resonance frequency that has been originally adjusted by capacitive gaps and inductive strips.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Integrated optical devices based on sol – gel waveguides using the temperature dependence of the effective refractive index

A possibility of designing optical waveguide devices based on sol – gel SiO{sub 2} – TiO{sub 2} films using the temperature dependence of the effective refractive index is shown. The dependences of the device characteristics on the parameters of the film and opticalsystem elements are analysed. The operation of a temperature recorder and a temperature limiter with a resolution of 0.6 K mm{sup -1} is demonstrated. The film and output-prism parameters are optimised. (fibreoptic and nonlinear-optic devices)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multichannel Fabry-Perot spectrometer for infrared astronomy

A multichannel design which makes use of the radiation normally rejected in a Fabry-Perot spectrometer is described, with application to infrared astronomy. The present optical design minimizes the diameters of the etalon and optics. The use of spherical mirrors ensures that no radiation is lost through the entrance aperture, and the beams can be completely collimated at the etalon. Laboratory studies demonstrate that the ability to employ eight channels increases by a factor of four the flux integrated during a given time period compared with that of a single-channel instrument. The spectrometer is nondispersive, and the source can be imaged at each of several output spectral positions.

Jennings, Donald E.↗

STATUS OF BEAM IMAGING DEVELOPMENTS FOR THE SNS TARGET

The Spallation Neutron Source (SNS) continues a ramp up in proton beam power toward the design goal of 1.4 MW on target. At Megawatt levels, US and Japanese studies have shown that cavitation in the Mercury target could lead to dramatically shortened target lifetime. Therefore, it will be critical to measure and control the proton beam distribution on the target, in a region of extremely high radiation and limited accessibility. Several sources of photons have been considered for imaging the beam on or near the target. These include a freestanding temporary screen, a scintillating coating, Helium gas scintillation, optical transition radiation, and a beam- heated wire mesh. This paper will outline the selection process that led to the current emphasis on coating development. In this harsh environment, the optics design presented significant challenges. The optical system has been constructed and characterized in preparation for installation. Optical test results will be described along with predictions of overall system performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

INJECTION OPTICS FOR THE JLEIC ION COLLIDER RING

The Jefferson Lab Electron-Ion Collider (JLEIC) will accelerate protons and ions from 8 GeV to 100 GeV. A very low beta function at the Interaction Point (IP) is needed to achieve the required luminosity. One consequence of the low beta optics is that the beta function in the final focusing (FF) quadrupoles is extremely high. This leads to a large beam size in these magnets as well as strong sensitivity to errors which limits the dynamic aperture. These effects are stronger at injection energy where the beam size is maximum, and therefore very large aperture FF magnets are required to allow a large dynamic aperture. A standard solution is a relaxed injection optics with IP beta function large enough to provide a reasonable FF aperture. This also reduces the effects of FF errors resulting in a larger dynamic aperture at injection. We describe the ion ring injection optics design as well as a beta-squeeze transition from the injection to collision optics.

Morozov, Vasiliy↗

Estimating of pulsed electric fields using optical measurements.

We performed optical electric field measurements ion nanosecond time scales using the electro optic crystal beta barium borate (BBO). Tests were based on a preliminary bench top design intended to be a proof of principle stepping stone towards a modular design optical E field diagnostic that has no metal in the interrogated environment. The long term goal is to field a modular version of the diagnostic in experiments on large scale x ray source facilities, or similarly harsh environments.

Flanagan, Timothy McGuire↗

The development of infrared detectors and mechanisms for use in future infrared space missions

The environment above earth's atmosphere offers significant advantages in sensitivity and wavelength coverage in infrared astronomy over ground-based observatories. In support of future infrared space missions, technology development efforts were undertaken to develop detectors sensitive to radiation between 2.5 micron and 200 micron. Additionally, work was undertaken to develop mechanisms supporting the imaging and spectroscopy requirements of infrared space missions. Arsenic-doped-Silicon and Antimony-doped-Silicon Blocked Impurity Band detectors, responsive to radiation between 4 micron and 45 micron, were produced in 128x128 picture element arrays with the low noise, high sensitivity performance needed for space environments. Technology development continued on Gallium-doped-Germanium detectors (for use between 80 micron and 200 micron), but were hampered by contamination during manufacture. Antimony-doped-Indium detectors (for use between 2.5 micron and 5 micron) were developed in a 256x256 pixel format with high responsive quantum efficiency and low dark current. Work began on adapting an existing cryogenic mechanism design for space-based missions; then was redirected towards an all-fixed optical design to improve reliability and lower projected mission costs.

Houck, James R.↗

Reluctant glass formers and their applications in lens design

Recently, a group of glasses has been investigated that have high refractive index and low dispersion. These glasses are known as reluctant glass formers and lie in the 'forbidden' region of the conventional glass map. Research is continuing to develop means and techniques to produce usable sizes and optical characteristics. Since these glasses have unusual optical properties, a study was performed to gain an understanding of the impact such glasses could have on optical design and to establish desired baseline optical properties as objectives for the material scientists. Several generic optical configurations were explored to determine if a meaningful improvement could be realized. Study results are presented and discussed to illustrate that a notable enhancement in optical performance is attainable.

Johnson, R. B.↗

Rectangular Relief Diffraction Gratings for Coherent Lidar Beam Deflection

LIDAR systems require a light transmitting system for sending a laser light pulse into space and a receiving system for collecting the retro-scattered light, separating it from the outgoing beam and analyzing the received signal for calculating wind velocities. Currently, a shuttle manifested coherent LIDAR experiment called SPARCLE (SPAce Readiness Coherent Lidar Experiment) includes a silicon wedge (or prism) in its design in order to deflect the outgoing beam 30 degrees relative to the incident direction. The intent of this paper is to present two optical design approaches that may enable the replacement of the optical wedge component (in future, larger aperture, post-SPARCLE missions) with a surface relief transmission diffraction grating. Such a grating could be etched into a lightweight, flat, fused quartz substrate. The potential advantages of a diffractive beam deflector include reduced weight, reduced power requirements for the driving scanning motor, reduced optical sensitivity to thermal gradients, and increased dynamic stability.

Cole, H. J.↗

Correlation of Predicted and Observed Optical Properties of Multilayer Thermal Control Coatings

Thermal control coatings on spacecraft will be increasingly important, as spacecraft grow smaller and more compact. New thermal control coatings will be needed to meet the demanding requirements of next generation spacecraft. Computer programs are now available to design optical coatings and one such program was used to design several thermal control coatings consisting of alternating layers of WO3 and SiO2. The coatings were subsequently manufactured with electron beam evaporation and characterized with both optical and thermal techniques. Optical data were collected in both the visible region of the spectrum and the infrared. Predictions of solar absorptance and infrared emittance were successfully correlated to the observed thermal control properties. Functional performance of the coatings was verified in a bench top thermal vacuum chamber.

Jaworske, Donald A.↗

Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES) for WFIRST/AFTA

Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES) is a prototype lenslet array based integral field spectrometer (IFS) designed for high contrast imaging of extrasolar planets. PISCES will be used to advance the technology readiness of the high contrast IFS baselined on the Wide-Field InfraRed Survey TelescopeAstrophysics Focused Telescope Assets (WFIRSTAFTA) coronagraph instrument. PISCES will be integrated into the high contrast imaging testbed (HCIT) at the Jet Propulsion Laboratory and will work with both the Hybrid Lyot Coronagraph (HLC) and the Shaped Pupil Coronagraph (SPC). We will present the PISCES optical design, including the similarities and differences of lenslet based IFSs to normal spectrometers, the trade-off between a refractive design and reflective design, as well as the compatibility to upgrade from the current 1k x 1k detector array to 4k x 4k detector array. The optical analysis, alignment plan, and mechanical design of the instrument will be discussed.

Integral Field Spectrometer↗

Modular Soft X-Ray Emission Spectrograph

We have been developing the Hettrick-Underwood type soft x-ray spectrograph for over a decade. This optical design uses one spherical mirror for focusing x-rays onto the CCD detector and a set of variable line-spacing gratings for energy analysis. Unlike the previous effort carried out at the ALS, what we have achieved in the current design is to incorporate the concept of modularity. The model of spectrograph is shown below. It contains three major components: the optics chamber and downstream section (detector plus driving mechanism using a swing arm pivoted at the grating location, see figure) for inside and outside order (translation stage without swing arm, not shown here). Inside order design is often used when source size is larger than the detector pixel resolution, while the outside order is used when source size is smaller than the detector pixel resolution. Irrespective to which order is selected, there is no change in the mechanism of optics chamber. The location of optics chamber relative to the source and detector can also be changed to optimize the energy resolution at target photon energy. The incident angles on mirror and gratings can be varied, in conjunction with the grating line densities, to balance the resolution and throughput. The internal components of optics chamber are also modular and changing the dimension of optics can be done by using different holders. The modularity not only greatly reduces the design and assembling effort, but also offers the cost benefit. Although the cost of this type of spectrograph is expected to be higher than XES350, it is still significant lower than the one-of-the-kind design used at every synchrotron facilities. The unique flexibility and modularity not only allows the users to tailor the design of spectrograph for the characteristic of their sources, but also to have cost down in standardizing the fabrication parts.

Hussain, Zahid↗

Design and performance of BOREAS, the beamline for resonant X-ray absorption and scattering experiments at the ALBA synchrotron light source

The optical design of the BOREAS beamline operating at the ALBA synchrotron radiation facility is described. BOREAS is dedicated to resonant X-ray absorption and scattering experiments using soft X-rays, in an unusually extended photon energy range from 80 to above 4000 eV, and with full polarization control. Its optical scheme includes a fixed-included-angle, variable-line-spacing grating monochromator and a pair of refocusing mirrors, equipped with benders, in a Kirkpatrick–Baez arrangement. It is equipped with two end-stations, one for X-ray magnetic circular dichroism and the other for resonant magnetic scattering. In conclusion, the commissioning results show that the expected beamline performance is achieved both in terms of energy resolution and of photon flux at the sample position.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fizeau wavemeter for pulsed laser wavelength measurement

A Fizeau wavelength meter optimized for use with pulsed laser sources has been developed and characterized which demonstrates a CW resolution better than 2 parts in 10 to the 7th and a pulsed resolution better than 1 part in 10 to the 6th. The static optical design is based on a Fizeau wedge interferometer, which together with spatial filtering and collimating optics is used to produce a pattern of parallel fringes which is imaged on a linear photodiode array and analyzed by a minicomputer. A series of CW and pulsed measurements of various narrowband laser sources are described, and particular difficulties involved in pulsed laser measurements with the wavemeter are examined.

Morris, M. B.↗

Simulation and Measurement of Stray Light in the CLASP

We are planning an international rocket experiment Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is (2015 planned) that Lyman Alpha line polarization spectroscopic observations from the sun. The purpose of this experiment, detected with high accuracy of the linear polarization of the Ly􀉲 lines to 0.1% by using a Hanle effect is to measure the magnetic field of the chromosphere-transition layer directly. For total flux of the sun visible light overwhelmingly larger and about 200 000 times the Ly􀉲 line wavelength region, also hinder to 0.1% of the polarization photometric accuracy achieved in the stray light of slight visible light. Therefore we were first carried out using the illumination design analysis software called stray light simulation CLASP Light Tools. Feature of this simulation, using optical design file (ZEMAX format) and structural design file (STEP format), to reproduce realistic CLASP as possible to calculate machine is that it was stray study. And, at the stage in the actual equipment that made the provisional set of CLASP, actually put sunlight into CLASP using coelostat of National Astronomical Observatory of Japan, was subjected to measurement of stray light (San test). Pattern was not observed in the simulation is observed in the stray light measurement results need arise that measures. However, thanks to the stray light measurement and simulation was performed by adding, it was found this pattern is due to the diffracted light at the slit. Currently, the simulation results is where you have taken steps to reference. In this presentation, we report the stray light simulation and stray light measurement results that we have implemented

CLASP↗

Gamma-Ray Mirrors. Quarterly Progress Report Q3 FY20 April-June 2020

During the third quarter of FY20, the optic design, or Phase II Task 2 of the project, continued. Our effort was focused on verifying 3D ray-tracing simulations representative of the IFEL set-up with cross-code comparison. Simulations for a single reflection Kirkpatrick-Baez optic showed the feasibility of a design that provides 1D focusing at the detector. Following an increase in scope of work in June, we have been actively engaging in preparations to conduct an additional experiment at IFEL before the end of the fiscal year.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗