Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OMEGA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Demonstration of fuel hot-spot pressure in excess of 50 Gbar for direct-drive, layered deuterium-tritium implosions on OMEGA

A record fuel hot-spot pressure P hs = 56±7 Gbar was inferred from x-ray and nuclear diagnostics for direct-drive inertial confinement fusion cryogenic, layered deuterium–tritium implosions on the 60-beam, 30-kJ, 351-nm OMEGA Laser System. When hydrodynamically scaled to the energy of the National Ignition Facility (NIF), these implosions achieved a Lawson parameter ~60% of the value required for ignition [A. Bose et al., Phys. Rev. E (in press)], similar to indirect-drive implosions [R. Betti et al., Phys. Rev. Lett. 114, 255003 (2015)], and nearly half of the direct-drive ignition-threshold pressure. Relative to symmetric, one-dimensional simulations, the inferred hot-spot pressure is ~40% lower. Furthermore, three-dimensional simulations suggest that low-mode distortion of the hot spot seeded by laser-drive nonuniformity and target-positioning error reduces target performance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Subpercent-Scale Control of 3D Low Modes of Targets Imploded in Direct-Drive Configuration on OMEGA

In a series of direct-drive implosions on OMEGA, multiple time resolved x-ray images were used to tomographically measure their 3-D modes 1, 2, and 3 at a convergence ratio of ~3. Results show that the target modes vary linearly with the laser modes and are not affected by the Rayleigh–Taylor growth or lateral heat transport. This indicates that the residual modes (resulting from physical effects including beam mistiming, mispointing, and laser energy calibration) are approximately constant between shots. Lastly, this demonstrates that the low-mode amplitudes can be mitigated within by adjusting the laser-energy balance to compensate the residual target modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of Laser Bandwidth in Direct-Drive High-Performance DT-Layered Implosions on the OMEGA Laser

In direct-drive inertial confinement fusion, the laser bandwidth reduces the laser imprinting seed of hydrodynamic instabilities. The impact of varying bandwidth on the performance of direct-drive DT-layered implosions was studied in targets with different hydrodynamic stability properties. The stability was controlled by changing the shell adiabat from (α F ≃ 5) (more stable) to (α F ≃ 3.5) (less stable). Herein these experiments show that the performance of lower adiabat implosions improves considerably as the bandwidth is raised indicating that further bandwidth increases, beyond the current capabilities of OMEGA, would be greatly beneficial. These results suggest that the future generation of ultra-broadband lasers could enable achieving high convergence and possibly high gains in direct drive ICF.

47 OTHER INSTRUMENTATION↗

Assessment of Model Confidence of a Laser Source Model in xRAGE Using Omega Direct-Drive Implosion Experiments

Los Alamos National Laboratory is interested in developing high-energy-density physics validation capabilities for its multiphysics code xRAGE. xRAGE was recently updated with the laser package Mazinisin to improve predictability. We assess the current implementation and coupling of the laser package via validation of laser-driven, direct-drive spherical capsule experiments from the Omega laser facility. Here, the ASME V&V 20-2009 standard is used to determine the model confidence of xRAGE, and considerations for high-energy-density physics are identified. With current modeling capabilities in xRAGE, the model confidence is overwhelmed by significant systematic errors from the experiment or model. Validation evidence suggests cross-beam energy transfer as a dominant source of the systematic error.

47 OTHER INSTRUMENTATION↗

OpenFAST Modeling of the T-Omega Wind Floating Offshore Wind Turbine System

To reduce the cost of offshore wind energy through a more efficient design of the floating support structure, T-Omega Wind developed a novel lightweight and shallow-draft platform concept that aims to achieve a wave-following behavior without resonance amplification. The rotor and generator are carried by four tower legs with each leg supported by a shallow-draft float at the base. In preparation for a more detailed analysis, a coupled aero-hydro-elastic model of the proposed concept is developed in OpenFAST. The detailed modeling approach is presented, including a novel application of the SubDyn substructure dynamics module of OpenFAST to approximate the loads on the axle tube at the tower top from the rotor hub bearings. Preliminary results obtained with the OpenFAST model by rigidifying the substructure and blades indicate that the original sizing of the design can lead to large hub acceleration in the axial/surge and pitch directions due to platform-pitch motion. The high axial acceleration also potentially leads to large bending moments in the four tower legs. To address these issues, an updated design is developed with, among other changes, increased float spacing at the tower base and improved shear-transmitting geometry of the tower legs. The new design suggests significantly reduced extreme hub accelerations under the same conditions even with structural flexibility and will be further analyzed in the future through full aero-hydro-servo-elastic simulations.

FOWT↗

Long-Term Monitoring the Damage Performance of Multilayer Dielectric Grating Samples Residing Inside the Compressor Chamber of the OMEGA EP Laser

Understanding of the laser-induced damage threshold and impact of air–vacuum cycling of the optical components in short-pulse laser systems is of fundamental importance. We report the results of a damage-testing campaign that monitored representative pulse compression grating samples that were positioned inside the OMEGA EP grating compressor vacuum chamber during normal operation and routinely damage tested on every quarterly vent for a period of about 10 years. Here, the evolution of their damage resistance under 10-ps and 100-ps pulse lengths are associated with a significant degradation of the laser-induced damage thresholds, which is comparatively larger at 100 ps, is described.

42 ENGINEERING↗

On-target uniformity of the OMEGA 60-beam inertial confinement fusion laser

Successful direct-drive inertial confinement fusion (ICF) experiments require excellent on-target laser 9 irradiance uniformity maintained over the duration of the pulse. Achieving this symmetry relies on maintaining an 10 energy, power, and fluence balance among all beams in a multibeam laser system. As a result of the improvements 11 described in this paper, the OMEGA 60-beam laser performance has been assessed at approximately 2% on-target 12 irradiance nonuniformity using an updated performance assessment metric that accounts for the laser diagnostic noise 13 floor. The performance is measurement-limited, prompting the need for an improved diagnostic suite. This manuscript 14 provides a comprehensive first-order assessment of extant status of on-target energy, power, and fluence uniformity 15 and explores avenues for improvements.

Diagnostics↗

Identification of contamination in the pulse-compression chamber of the OMEGA EP Laser System originating from clean room garments

The contamination of optical components with microscopic particles strongly impacts their ability to handle high-power or high-intensity laser pulses via an array of mechanisms. This work explores the nature and origin of a subset of contamination particles found inside the pulse-compression chamber of the OMEGA EP Laser System. Using Raman microscopy accompanied by other analytical methods, it was shown that sodium nitrate constitutes a significant fraction of the particles that possess diameters on the order of a few micrometers. Further investigation aiming to reveal the origin of these particles suggests that these sodium nitrate particles are deposited via shedding from the reusable clean room garments worn in the Laser Bay and compression chamber. Raman microscopy also revealed various plastic particles such as polystyrene, polyethylene, and poly(diallyl isophthalate).

Raman spectroscopy↗

Single-shot temporal characterization of kilojoule-level, picosecond pulses on OMEGA EP

To achieve a variety of experimental conditions, the OMEGA EP laser provides kilojoule-level pulses over a pulse-width range of 0.6 to 100 ps. Precise knowledge of the pulse width is important for laser system safety and the interpretation of experimental results. This paper describes the development and implementation of a single-shot, ultrashort-pulse measurement diagnostic, which provides an accurate characterization of the output pulse shape. We also present a brief overview of the measurement algorithm; discuss design considerations necessary for implementation in a complex, user-facility environment; and review the results of the diagnostic commissioning shots, which demonstrated excellent agreement with predictions.

36 MATERIALS SCIENCE↗

In-tank, on-shot characterization of the OMEGA laser system focal spot

Direct-drive fusion implosion experiments using the 60-beam OMEGA Laser System require ~1% rms uniformity on target. Measurements from laser diagnostics indicate that beam-to-beam power variation has been sufficiently reduced such that the uniformity nearly meets this requirement; however, experimental results suggest otherwise. To better understand this discrepancy, a full-beam-in-tank diagnostic has been developed to characterize the on-shot, full-energy focal spot of a single beam inside the target chamber using a small sample of the beam from the final optic assembly. In this paper, we describe the diagnostic and present the results of commissioning experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Co-timing UV and IR laser pulses on the OMEGA EP laser system

Independently managing the timing of individual beams so they all arrive at the target within 10 ps of the time specified by the principal investigator is crucial to the success of experiments on the OMEGA EP Laser System. A streak camera is used to observe the x rays emitted when the laser beams strike a gold target, while an optical streak camera is used to measure the UV pulses. Furthermore correlating the signal on the two instruments gives a timing accuracy of 10 ps for the short pulse IR beams and 20 ps for the long-pulse UV beams.

42 ENGINEERING↗

Power balancing the multibeam OMEGA laser

Multibeam lasers often require an output beam balance that specifies the degree of simultaneity of laser output energy, instantaneous power, or instantaneous irradiance (power per unit area). In this work the general problem of balancing a multibeam laser is described. Specific techniques used to balance the output power of the 60-beam pulsed OMEGA Laser System are discussed along with a measured reduction of beam-to-beam imbalance. In particular, the square-pulse distortion induced by a simple saturating amplifier operating with its output at some fraction of its saturation fluence is derived, and a novel method of exchanging gain between saturated amplifiers in a single beam that have different saturation fluences to adjust balance is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Summaries of FY12 LANL Experimental Campaigns at the OMEGA Laser Facility

In FY 2012, Los Alamos National Laboratory (LANL) executed 244 total shots on OMEGA. LANL experiments contributed to the National Ignition (NIC) campaign in the following ways: • Measured the x-ray ablative Richtmyer-Meshkov growth of isolated defects on plastic ablators, • Studied branching ratios in DT fusion plasmas, and • Continued neutron imaging and radchem scintillator development for NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

FY17 LLNL Omega Experimental Programs

The Capseed campaign goal is to measure shock front velocity non-uniformities in Inertial Confinement Fusion (ICF) ablator materials and quantify the level of non-uniformity caused by intrinsic effects. This is done using the Omega High Resolution Velocimeter (OHRV) to obtain velocity maps of the optically reflecting shock front following release of the ablator material into either PMMA for the warm experiments or cryogenic deuterium for the cryo experiments. For the three half-days in FY17 the focus was twofold: complete measurements on the impact of oxygen heterogeneity and oxygen mitigation layers for glow discharge polymer (GDP), and begin measuring velocity non-uniformities on deep release from Be, GDP, and highdensity carbon (HDC) into D2 with improved velocity sensitivity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗