Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Normal modes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

522 records · Page 29

High-power test of a C-band linear accelerating structure with an RFSoC-based LLRF system

Normal conducting linear particle accelerators consist of multiple rf stations with accelerating structure cavities. Low-level rf (LLRF) systems are employed to set the phase and amplitude of the field in the accelerating structure and to compensate for the pulse-to-pulse fluctuation of the rf field in the accelerating structures with a feedback loop. The LLRF systems are typically implemented with analog rf mixers, heterodyne-based architectures, and discrete data converters. There are multiple rf signals from each of the rf stations, so the number of rf channels required increases rapidly with multiple rf stations. With a large number of rf channels, the footprint, component cost, and system complexity of the LLRF hardware will increase significantly. To meet the design goals of being compact and affordable for future accelerators, we have designed the next-generation LLRF (NG-LLRF) with a higher integration level based on RFSoC technology. The NG-LLRF system samples rf signals directly and performs rf mixing digitally. Further, the NG-LLRF has been characterized in loopback mode to evaluate the performance of the system and has also been tested with a standing-wave accelerating structure, a prototype for the Cool Copper Collider (C 3 ) with a peak rf power level up to 16.45 MW. The loopback test demonstrated amplitude fluctuation below 0.15% and phase fluctuation below 0.15°, which are considerably better than the requirements of C 3 . The rf signals from the different stages of the accelerating structure at different power levels are measured by the NG-LLRF, which will be critical references for the control algorithm designs. The NG-LLRF also offers flexibility in waveform modulation, so we have used rf pulses with various modulation schemes, which could be useful for controlling some of the rf stations in accelerators. In this paper, the high-power test results at different stages of the test setup will be summarized, analyzed, and discussed.

47 OTHER INSTRUMENTATION↗

Tensile Modeling PVC Gels for Electrohydraulic Actuators

Polyvinyl chloride (PVC)-dibutyl adipate (DBA) gels are a fascinating dielectric elastomer actuator showing promise in soft robotics. When actuated with high voltages, the gel deforms towards the anode. A recent application of PVC gels in electrohydraulic actuators motivates elastic and hyperelastic constitutive relationships for tensile loading modes. PVC gels with plasticizer-to-polymer weight ratios of 2:1, 4:1, 6:1, and 8:1 w/w were evaluated. PVC gels exhibit a linear elastic region up to 25% strain. The elastic modulus decreased with increasing plasticizer content from 288.8 kPa, 56.1 kPa, 24.7 kPa, to 11 kPa. Poisson’s ratio also decreased with increasing plasticizer content from 0.42, 0.43, 0.39, to 0.35. We suggest that the decrease in polymer concentration facilitates a weakly interconnected polymer network susceptible to chain slippage that hinders the network response, thus lowering Poisson’s ratio. Our work suggests that PVC gels can be treated as isotropic and incompressible for large strains and hyperelastic modeling; however, highly plasticized gels tend to act less incompressible at small strains. The power scaling law between the elastic modulus and plasticizer weight ratio showed high agreement, making the elastic modulus deterministic for any plasticizer content. The Neo–Hookean, Mooney–Rivlin, Yeoh, Gent, Ogden, and extended tube hyperelastic constitutive models are investigated. The Yeoh model shows the highest feasibility when evaluated up to 3.5 stretch, showing a maximum normalized root-mean-square-error of 6.85%. Together, these findings establish a constitutive basis for PVC-DBA gels, incorporating small strain elasticity, large strain non-linear behavior, and network analysis while providing suggestive insight into the network structure required for accurately modeling the EPIC.

Polymer Science↗

Progress in extending high poloidal beta scenarios on DIII-D towards a steady-state fusion reactor and impact of energetic particles

To prepare for steady-state operation of future fusion reactors (e.g. the International Thermonuclear Experimental Reactor and China Fusion Engineering Test Reactor (CFETR)), experiments on DIII-D have extended the high poloidal beta ( β P ) scenario to reactor-relevant edge safety factor q 95 ~ 6.0, while maintaining a large-radius internal transport barrier (ITB) using negative magnetic shear. Excellent energy confinement quality ( H 98y2 > 1.5) is sustained at high normalized beta ( β N ~ 3.5). This high-performance ITB state with Greenwald density fraction near 100% and q min ≥ 3 is achieved with toroidal plasma rotation V tor ~ 0 at ρ ≥ 0.6. This is a key result for reactors expected to have low V tor . At high β P (≥1.9), large Shafranov shift can stabilize turbulence leading to a high confinement state with a low pedestal and an ITB. At lower β P (<1.9), negative magnetic shear in the plasma core contributes to turbulence suppression and can compensate for reduced Shafranov shift to continue to access a large-radius ITB and excellent confinement with low V tor , consistent with the results of gyrofluid transport simulations. These high- β P cases are characterized by weak/no Alfvén eigenmodes (a.e.) and classical fast-ion transport. At high density, the fast-ion deceleration time decreases and Δ β fast is lower; these reduce a.e. drive. The reverse-shear Alfvén eigenmodes are weaker or stable because the negative magnetic shear region is located at higher radius, away from the peaked fast-ion profile. Resistive wall modes can be a limitation at simultaneous high β N , low internal inductance, and low rotation. Analysis suggests that additional off-axis external current drive could provide a more stable path at reduced q 95 . Based on a DIII-D high- β P plasma with large-radius ITB, two scenarios are proposed for CFETR Q = 5 steady-state operation with ~1 GW fusion power: a lower-$l_i$($l_i$ ~ 0.66) and a higher-$l_i$($l_i$ ~ 0.75) case. Using a Landau closure model, multiple energetic particle (EP) effects on the a.e. stability are analyzed modifying the growth rate of the a.e.s triggered by the neutral-beam-injection EPs and alpha particles, although the stabilizing/destabilizing effect is weak for the cases analyzed. The stabilizing effects of the combined EP species β , energy, and density profile in CFETR need further investigation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Open-Loop Control of Adjustable Tuned Mass Dampers for Floating Wind Turbine Platforms: Preprint

Floating offshore wind turbines have several advantages over their land-based counterparts, including access to stronger, more consistent winds and proximity to population centers. However, increased costs from the platform have been a challenge inhibiting their widespread adoption. New damping technologies with tunable target frequencies and damping ratios promise a greater degree of control over platform motions, allowing hulls to be designed smaller and reducing the overall cost of the turbines. In this work, a control strategy is proposed for these adjustable tuned mass dampers (TMDs). A frequency-domain model of the system is developed, from which response amplitude operators (RAOs) for the platform's rigid-body modes can be obtained for different natural frequencies and damping ratios of the dampers. Using these RAOs, and JONSWAP spectrums of operational and extreme sea states, the performance of the various damper settings are compared by evaluating the standard deviation of a rigid-body motion of interest (platform pitch or heave). By finding the optimal damper setting for a range of representative design load cases (DLCs), a lookup function is made to return the damper target frequency given the peak period of the sea state. To determine the current sea state, we propose a simple estimator that uses wave measurements (e.g., from a measurement buoy) to determine the peak period and significant wave height. The significant wave height is determined using the statistics of the past 100 seconds of wave elevation information and the peak period is computed using a frequency locked loop. Initial results show that we can use these estimated values to control the TMD natural frequency with an open loop controller. The controlled system is tested in a range of environmental conditions determined by the International Electrotechnical Commission design load cases (DLCs), which include normal and extreme wind and wave models. In these tests, we compare the performance of 4 cases: (1) no TMD, (2) a constant TMD based on the worst case DLC, (3) a controlled TMD based on known wind and wave environments, and (4) a real-time controlled TMD using estimated wind and wave environments. The effect of hull-based TMD control is also compared to changes in traditional wind turbine control via blade pitch.

control↗

Tailoring planar slip to achieve pure metal-like ductility in body-centred-cubic multi-principal element alloys

Uniform tensile ductility (UTD) is crucial for the forming/machining capabilities of structural materials. Normally, planar-slip induced narrow deformation bands localize the plastic strains and hence hamper UTD, particularly in body-centred-cubic (bcc) multi-principal element high-entropy alloys (HEAs), which generally exhibit early necking (UTD < 5%). Here we demonstrate a strategy to tailor the planar-slip bands in a Ti-Zr-V-Nb-Al bcc HEA, achieving a 25% UTD together with nearly 50% elongation-to-failure (approaching a ductile elemental metal), while offering gigapascal yield strength. The HEA composition is designed not only to enhance the B2-like local chemical order (LCO), seeding sites to disperse planar slip, but also to generate excess lattice distortion upon deformation-induced LCO destruction, which promotes elastic strains and dislocation debris to cause dynamic hardening. Further, this encourages second-generation planar-slip bands to branch out from first-generation bands, effectively spreading the plastic flow to permeate the sample volume. Moreover, the profuse bands frequently intersect to sustain adequate work-hardening rate (WHR) to large strains. Our strategy showcases the tuning of plastic flow dynamics that turns an otherwise-undesirable deformation mode to our advantage, enabling an unusual synergy of yield strength and UTD for bcc HEAs.

36 MATERIALS SCIENCE↗

Two-mode bosonic quoctit for high energy physics

In this work, we study a two-mode bosonic encoding of a quoctit inside a non-Abelian group-structured constellation of coherent states. This work is motivated by the importance of non-Abelian symmetry in particle physics and the desire to have transversal non-Abelian logical gates. We use the previously developed 2 T constellation of states used to encode a so-called 2 T qutrit. The fidelity of the 2 T quoctit is benchmarked against other bosonic qudits for different noise models and find it compare favorably when power constraints are considered. This paves the way for the construction of higher-dimensional qudits (e.g., a quicosotetrit with 2 T group structure) in bosonic systems with practical applications in quantum simulations of particle physics.

Kürkçüoglu, Doga Murat [Fermilab] (ORCID:000000031↗

Enhancement of Ni–(Y 2 O 3 ) 0.08 (ZrO 2 ) 0.92 fuel electrode performance by infiltration of Ce 0.8 Gd 0.2 O 2–δ nanoparticles

This paper addresses the use of Ce 0.8 Gd 0.2 O 2–δ (GDC) infiltration into the Ni–(Y 2 O 3 ) 0.08 (ZrO 2 ) 0.92 (YSZ) fuel electrode of solid oxide cells (SOCs) for improving their electrochemical performance in fuel cell and electrolysis operation. Although doped ceria infiltration into Ni–YSZ has recently been shown to improve the electrode performance and stability, the mechanisms defining how GDC impacts electrochemical characteristics are not fully delineated. Furthermore, the electrochemical characteristics have not yet been determined over the full range of conditions normally encountered in fuel cell and electrolysis operation. Here we present a study of both symmetric and full cells aimed at understanding the electrochemical mechanisms of GDC-modified Ni–YSZ over a wide range of fuel compositions and temperatures. Single-step GDC infiltration at an appropriate loading substantially reduced the polarization resistance of Ni–YSZ electrodes in electrolyte-supported cells, as measured using electrochemical impedance spectroscopy (EIS) at various temperatures (600–800 °C) in a range of H 2 O–H 2 mixtures (3–90 vol% H 2 O). Fuel-electrode-supported cells had significant concentration polarization due to the thick Ni–YSZ supports. Here, a distribution of relaxation times approach is used to develop a physically-based electrochemical model; the results show that GDC reduces the reaction resistance associated with three-phase boundaries, but also appears to improve oxygen transport in the electrode. Increasing the H 2 O fraction in the H 2 –H 2 O fuel mixture reduced both the three-phase boundary resistance and the gas diffusion resistance for Ni–YSZ; with GDC infiltration, the electrode resistance showed less variation with fuel composition. GDC infiltration improved the performance of fuel-electrode-supported full cells, which yielded a maximum power density of 2.28 W cm –2 in fuel cell mode and an electrolysis current density at 1.3 V of 2.22 A cm –2 , both at 800°C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiation testing of 2.4 micron wavelength extended InGaAs photodiodes for 100 MeV/n carbon ions

We have successfully tested simultaneously 2.4 Micron Wavelength, Extended InGaAs Photodiodes having diameters of 20, 30, 40, 50, 100, 150, 200, 250, and 290 Micron, coupled with a Single Mode Fiber using 100 MeV/n Carbon (C) Ions up to a cumulative dose of ~40 krad. During irradiation, the devices were maintained at dry ice temperature, reverse biased at 100 mV, and their leakage current was continuously monitored in-situ during the run. After the exposure was completed, all nine devices were monitored for any change in their leakage current at 100 mV and room temperature for several weeks to monitor any annealing effects that may occur. Nine Photodiodes with the above varying diameters were radiated with 100 MeV/n Carbon Ions with a fluence of 10 6 , 10 7 , 10 8 , 10 9 , and 10 10 ions/cm 2 at each fluence level. At 100 MeV/n the Linear Energy Transfer (LET) of Carbon Ion is ~0.156 MeV-cm 2 /mg in Extended InGaAs, which is an order magnitude more than Proton (H) and Helium (He) Ions of 100 MeV/n energy. Thus, significant displacement damage is anticipated in the Extended InGaAs Photodiode with 100 MeV/n Carbon Ions with a total fluence of 1 × 1010 ions/cm 2 . Pre- and Post- radiation results were also measured for: (1) Leakage Current Vs. Voltage for the Extended InGaAs Photodiodes; (2) Responsivity (Quantum Efficiency) in A/W for Photodiodes; and (3) Bandwidth of the Photodiodes. All devices were found to be fully functional at the normal operating conditions and at both dry ice and room temperature. The leakage current increased up to a factor of ~2X at lower bias of 100 mV at the highest fluence of 10 10 ions/cm 2 , but not significantly at higher bias of 2 V. Finally, we did not observe any post radiation annealing effect for leakage current at room temperature and 100 mV bias for any of the devices after several weeks of data logging.

2.4 micron wavelength↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

First DIII-D-West hybrid scenario similarity experiments for iter-relevant long-pulse operation

For the first time, similarity experiments between DIII-D and WEST were performed in the ITER "hybrid-like" regime during dedicated campaigns in April and May 2025. The matched parameters include elongation, triangularity, ion ∇B drift direction toward the X-point, qprofile, and core normalized physics quantities in terms of normalized pressure, normalized gyroradius, electron collisionality, ratio of ion to electron temperature, T i /T e . Core transport physics is explored with different aspect ratio (R/a) values (typically 3 at DIII-D and 5 on WEST). DIII-D explored high-beta conditions (electromagnetic effect) with low torque injection (~0 ± 0.5 N•m) using high heating power (up to 6 MW NBI and 2 MW ECRH powers), while scanning the heating mix (ion vs electron), beta, T i /T e , core radiation via controlled tungsten injection using the Laser Blow-Off system. WEST extended operation toward long-duration pulses using its actively cooled tungsten divertor, achieving dominated electron heating regimes with reduced tungsten contamination. Boron impurity injection were scanned on WEST to control edge conditions and core performance. It is found that core confinement improves-manifested by higher electron temperature, total energy content, neutron rate, and ion temperatureunder conditions of low separatrix density, consistent with previous observations [Bourdelle et al., Nucl. Fusion 63 (2023) 056021]. Conditions for Hmode access and for ion heating in electron-dominated regimes in both WEST and DIII-D will be discussed and compared. The ratio of the thermal energy confinement time (τ E ) to the volume-averaged electron-ion collisional heat exchange time (τ e-i ) is a key parameter to enhance ion heating and potentially facilitate H-mode access in electron-heated regimes. These first-of-a-kind coordinated DIII-D and WEST experiments provide a unique multi-machine dataset to validate predictive models and to optimize ITER hybrid-scenario performance under diverse core and edge conditions.

DIII-D↗

Development of an MC&A toolbox for liquid-fueled molten salt reactors with online reprocessing (Final Report)

A critical barrier to the deployment of MSRs is the absence of a well-defined nuclear material control and accounting (MC&A) approach, a vital prerequisite to meet NRC licensing requirements as well as facilitating future international exports. Liquid-fueled MSR variants (especially those incorporating online refueling or reprocessing) present a unique set of challenges to traditional nuclear material control and accountancy. Unlike solid-fueled light-water reactors, traditional item-counting methods cannot be applied as an accountancy strategy. Rather, MC&A approaches to MSR variants (including both uranium and thorium fueled designs) are more analogous to bulk material handling facilities (e.g., enrichment and reprocessing); yet further complicating matters is the fact that fuel medium is also highly radioactive. Meanwhile, the space of MSRs covers a broad range of design parameters, including thermal and fast spectra designs; operation in actinide breeder or burner modes, choice of actinide fuel used (e.g., 235 U, 232 Th / 233 U, denatured 233 U, etc.), pool or loop-type configuration, and even different salt chemistry. Each of these design choices introduce significant challenges to MC&A approaches within MSR facilities. We propose to bridge this gap for liquid-fueled MSRs by developing a modular, component-based test framework for evaluating viable process monitoring and MC&A techniques specifically suited to liquid-fueled MSR system variants employing online refueling or reprocessing. This test platform will consist of a toolbox of independent process modules representing discrete physical units (such as the reactor core, off-gas processing, decay tanks, and actinide separation units), each with its own self-contained physics responsive to the input mass flow, along with appropriate measurement models that can be coupled to key flow points. These dynamic physical signatures thus afford the ability to test the viability and efficacy of potential accountancy techniques under the full range of reactor operating conditions. As process modules are connected via mass flows, the result is a reconfigurable, generic MSR mass flow model capable of serving as an MC&A test platform for a broad spectrum of possible MSR configurations. The resulting MSR MC&A toolbox will enable robust assessment of accountancy strategies for this unique facility type, including analysis of physical feedbacks arising both from depletion of the fuel over time as well as from potential off-normal events, including those introduced by equipment failures (e.g., a pump failure) as well as by malicious action (i.e., attempts to divert material). The proposed toolbox both addresses a critical needs area for the MPACT analysis toolkit while leveraging existing MPACT-sponsored tools, especially with respect to simulation of measurement and accountancy techniques for advanced fuel cycle facilities. Beyond enabling new analysis capabilities for MSR systems, the design of this toolbox will be to such to maximize compatibility with existing MPACT tools, such to enhance existing facility MC&A analysis capabilities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Strong electron–phonon coupling in magic-angle twisted bilayer graphene

The unusual properties of superconductivity in magic-angle twisted bilayer graphene (MATBG) have sparked considerable research interest. However, despite the dedication of intensive experimental efforts and the proposal of several possible pairing mechanisms, the origin of its superconductivity remains elusive. Here, by utilizing angle-resolved photoemission spectroscopy with micrometre spatial resolution, we reveal flat-band replicas in superconducting MATBG, where MATBG is unaligned with its hexagonal boron nitride substrate. These replicas show uniform energy spacing, approximately 150 ± 15 meV apart, indicative of strong electron–boson coupling. Strikingly, these replicas are absent in non-superconducting twisted bilayer graphene (TBG) systems, either when MATBG is aligned to hexagonal boron nitride or when TBG deviates from the magic angle. Calculations suggest that the formation of these flat-band replicas in superconducting MATBG are attributed to the strong coupling between flat-band electrons and an optical phonon mode at the graphene K point, facilitated by intervalley scattering. These findings, although they do not necessarily put electron–phonon coupling as the main driving force for the superconductivity in MATBG, unravel the electronic structure inherent in superconducting MATBG, thereby providing crucial information for understanding the unusual electronic landscape from which its superconductivity is derived.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of beam ion loss in high poloidal beta regime on EAST

A critical issue for achieving the integrated operation of steady-state long-pulse high-confinement (H-mode) plasmas on experimental advanced superconducting tokamak (EAST) is to improve beam ion population confinement during neutral beam injection (NBI). To study the characterization of beam ion loss and improve beam ion confinement, the steady-state long pulse scenario discharges were conducted on EAST (β p $\geqslant$ 2.0, β N $\geqslant$ 1.7, q 95 $\geqslant$ 6.7 and H 98y2 $\geqslant$ 1.1) with NBI heating. Based on neutron yield, the beam voltage and line-averaged electron density were adjusted from 50 kV to 60 kV and 4.4 × 10 19 m –3 to 5.0 × 10 19 m –3 , respectively. The results show that the dominant mechanisms of beam ion loss are shine-through loss, prompt loss, and stochastic ripple loss. The shine-through loss fraction is determined by initial velocity, flight time and entire beam path. The change in prompt loss fraction is caused by the change in the deposition of beam ions. The change in stochastic ripple loss fraction is caused by the change in the initial fraction of trapped-confined ions. Detailed physics shows that the prompt loss fraction during counter-Ip injections (~45%) is far larger than during co-Ip injections (~5%) due to the finite orbit width. The lost ions are mainly deposited on the lower divertor or below the midplane since the direction of magnetic drift is vertical down. The orbit types of prompt loss during counter-Ip injections are mainly trapped-lost and ctr-passing lost. To minimize the prompt loss fraction during counter-Ip injections, a reversed Ip configuration (rev-Ip) discharge #94758 was conducted. The result suggests that the beam ion wall load fraction during counter-Ip tangential injection (~3%) is far lower than that in normal Ip configuration (nor-Ip) discharge #94820. It is also found that the confinement of beam ion population in the counter-Ip injection #94758 was greatly improved when compared to #94820. Finally, this study can provide unique support for the improvement of beam ion population confinement and for the performance evaluation of the NBI system on EAST and future tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Linear simulation of magnetohydrodynamic plasma response to three-dimensional magnetic perturbations in high-β P plasmas

In this work, we report the numerical analyses of linear magnetohydrodynamics (MHD) plasma response to applied three-dimensional magnetic perturbations (MPs) in a joint DIII-D/EAST collaboration on high-β P (poloidal beta) plasmas, utilizing the extended-MHD code M3D-C1, with the purpose of realizing a better understanding of the existing experiment in which the n=3 MPs were applied to such high-β P plasmas attempting to control large amplitude type-I ELMs. Such high-β P plasmas obtained at the DIII-D tokamak feature an upper-biased double null configuration, a high edge safety factor q 95 ~6.4, and a stable internal transport barrier (ITB) leading to relatively high core pressures. Single-fluid simulations show that the plasma response to n=3 MPs, including both non-resonant/kinking and resonant components, is significantly weaker than that to n=1 or 2 MPs. To survey the impact of q 95 on plasma response to applied MPs, the SEGWAY (Self-consistent Equilibrium Generating Workflow for AnalYsis) module, developed in the OMFIT integrated modelling framework, is employed to generate a series of equilibria with a wide range of q 95 while other key parameters including the normalized beta, electron density at pedestal top, and plasma shape are kept fixed. Compared to the vacuum response, single-fluid M3D-C1 simulations predict a much more significant decrease of resonant plasma response to the applied n=3 MPs at the maximum penetration radii as q 95 increases. In contrast to single-fluid simulation results showing resonant penetration occurs only near the pedestal top where the E×B toroidal rotation frequency is zero, two-fluid simulations show two comparable resonant penetrations locating near the pedestal top and the ITB foot, where the perpendicular electron rotation frequency is zero. Such resonant field penetration near the ITB foot may be responsible for the observed formation of a staircase structure in both electron density and temperature profiles and thereby a considerable deterioration of global plasma performance when MPs are applied in high-β P plasmas. Motivated by this numerical work, we provide some ideas for the future research, with the purpose of realizing effective ELM control in such high-β P plasmas on the DIII-D and EAST devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simultaneous ELM suppression and divertor detachment via synergistic boron powder and neon injection in EAST

A novel approach for simultaneous power exhaust and edge-localized mode (ELM) control is presented in the Experimental Advanced Superconducting Tokamak discharges, which utilize an ITER-like tungsten divertor. Real-time injection of boron (B) powder and neon (Ne) gas overcomes their limitations encountered when used separately. Pure Ne seeding leads to a narrow operational window constrained by core impurity accumulation and H-mode to L-mode back transitions, while pure solid B injection (SBI) is insufficient for effective divertor cooling. In comparison, their combined use achieves a stable, stationary, ELM-suppressed H-mode with adequate power exhaust. This synergistic scenario features partial energy detachment at the outer divertor while maintaining good plasma confinement (H 98 ∼ 1) with minimal degradation. Two key features of this scenario are: (1) the SBI triggers a persistent Edge Harmonic Mode (EHM), which provides a crucial continuous particle transport channel, preventing Ne and tungsten/molybdenum accumulation without flushing out by ELM, and (2) the B + Ne mixture allows for active optimization of the radiated power profile. Core radiation can be reduced by substituting a portion of the Ne with B, leveraging their complementary non-coronal equilibrium radiation efficiencies. This combined B + Ne injection scheme presents a promising pathway toward integrated core-edge scenarios, offering the potential to minimize total impurity throughput while leveraging an actuator (powder injection) already being considered for ITER.

Boron↗

A Survey of Multizone Airflow Simulation Software

H-Canyon simulates the building and process ventilation to ensure positive contamination control for any modifications as well as evaluating off-normal conditions. Simulations can also be used to identify air quality of personnel occupied areas. The models can be classified into two groups, single and multi-zone models. As the name states, a single zone model assumes that the building can be described by a single, well-mixed zone. Whereas large buildings have structures that must be described as multizone. Multizone airflow models deal with the difficulty of flows in a building by distinguishing the effects of internal flow restrictions. Several models have been developed that take internal partitions into account. CONTAM (currently used) is a multizone airflow program created by NIST to determine airflows including infiltration, exfiltration, wind pressures acting outside the building, buoyancy effects caused by the indoor and outdoor air temperature difference. COMIS is a multizone air infiltration, ventilation, and contaminant transport model that was developed at Lawrence Berkeley National Laboratory. COMIS deals with applied pressure distribution, airflow components, HVAC systems, schedules, and contaminant transport. EnergyPlus is designed by DOE. It supports flexible component level configuration of HVAC models and simulates sub-hourly time steps to control fast dynamic systems. The program features include providing accurate environmental performance data including energy consumption and carbon emissions, and reporting solar gains on surfaces. Heavent is used to model industrial ventilation systems to control airborne contaminants. It's designed based on the American Conference of Governmental Industrial Hygienists (ACGIH) Ventilation manual. DesignBuilder is the most recognized and advanced user interface to EnergyPlus. It gives access to all of the most frequently required simulation capabilities covering building fabric, thermal mass, glazing, shading renewables, and HVAC analysis. The objective of this study is to identify all relevant software available including commercially licensed, freely licensed, and open source, that can be used to simulate large, complex process facility ventilation systems. All discovered software tools are evaluated for salient features and compared to the software tool currently used to simulate the H-Canyon ventilation system. The design criteria of a ventilation system has two basic requirements: Supplying fresh air for the occupants and changing the air in the room sufficiently; therefore, the smells, fumes, and contaminants will be removed. In this study, first, whether the software simulates airflow (infiltration, natural ventilation, and interzonal) or considers them to be inputs is discussed. Second, if indoor contaminant levels are considered; and finally suggestions on how airflow analysis can be more appropriately accounted for when performing airflow simulation of a building. All of the airflow software reviewed for this study can account for constant infiltration and natural ventilation rates that are not affected by changes in indoor and outdoor conditions. Modelling infiltration in EnergyPlus or DesignBuilder are applicable for small buildings and not appropriate for larger buildings like the H-Canyon. The effect of wind on external pressures, infiltration, and natural and mechanical ventilation, can also be calculated using all of these software. These programs have control options to switch between natural to mechanical ventilation modes or both (hybrid). Interzonal airflow can be applied which means one zone can be specified to receive a fixed amount of air from another zone. The following ventilation modeling software is recommended for further testing: CONTAM, COMIS, Heavent. The next step in evaluating the software will consist of creating test facility simulations using evaluation copies of the software.

42 ENGINEERING↗

In-Sodium Testing of a Prototype Thermoacoustic Power Sensor for Sodium-Cooled Fast Reactors

The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Novel Technique for Distributed Measuring of Strain in the Vadose Zone

Characterizing water content and pressure changes in the vadose zone is important to understanding a variety of geologic processes, ranging from permeability, to evapotranspiration, and aquifer recharge. Changes in water content, or pressure, cause strain in the solid porous medium of the vadose zone, and it is possible that measuring those strains could be used a characterization tool. The Coherence-length-gated Microwave Photonics Interferometry (CMPI) technique measures strain at high resolution along many intervals defined by pairs of reflectors distributed along an optical fiber. This technique has recently been developed at Clemson University, and it has the spatial, and temporal resolution to characterize the strains that are expected to occur with hydrologic changes in the vadose zone. However, the technique has never been used to measure strain in porous media, so its capabilities remain uncertain. The objective of this thesis is to evaluate the ability of using CMPI to measure strain changes in the vadose zone. The research approach consists of conducting laboratory tests using a column filled with sand that was subjected to changes in water content and pressure. An optical fiber with CMPI reflectors was deployed in a high surface area ribbon and used to measure strain along the axis of the column. The column was made from 8-inch, Schedule 40 PVC pipe (75 cm tall, 20 cm inner diameter) and filled with medium-grained sand (K = 2.5x10-6 m/s, porosity = 0.28, Coefficient of Uniformity = 2, van Genuchten (n = 4.34 and  = 0.00039 m-1), Young’s Modulus = 18 – 47 MPa). Five pressure and four temperature sensors attached to probes inserted into the wall. The optical fiber includes five reflectors spaced 10 cm apart on the inside and outside of the column along the vertical axis. Strain measurements are made between pairs of reflectors. The reflectors are created in 250-micron-diameter acrylate-coated single mode Corning SMF28e+ optical fiber using a femtosecond laser. The optical fiber was laminated between two pieces of polyester film creating a large surface area to transfer strain from the porous media to the optical fiber. The experiments were conducted by filling the column from the bottom or infiltrating water from the top. The water was allowed to equilibrate to room temperature prior to each test in order to limit thermoelastic strain. Five injection tests with a rate of 250 ml/min and three infiltration tests at varying rates were conducted, and the results show patterns of strain and pressure are generally similar. Hydrologic conditions define three zones based on the pressure magnitude and distribution. 1.) Ambient Zone where the pressure heads are quasi-static and the pressure gradient is roughly unity (head gradient of zero). This is the uppermost zone and is characterized by negative pressures. 2.) Transition Zone where the pressures increase from ambient to zero, are changing relatively rapidly and the pressure gradient is relatively steep (pressure head gradients of 2). The Transition zone is 10 to 15 cm thick. 3.) Positive Pressure Zone where the pressure is positive, the rate of change is slower than in the transition zone and the gradient is flatter (pressure head gradient 1.1 to 1.2). This is the lowest zone in the column. Injection of water causes the pressure to increase and the three zones to move upward. The Transition zone moves at a rate of approximately 0.0002 m/s +/- .00005, according to analyses of pressure profiles. This is the same as the average velocity of the water calculated as volumetric flux/effective porosity =5.4x10-5 m/s/0.28. Strain signals in the range of 10s  were observed with a noise level of generally less than 0.1  (signal to noise ratio of greater than 100) during injection and drainage. The spatial and temporal distributions of strain caused by injection depend on the location of the moving pressure zones. The locations of the different pressure zones were determined from pressure profiles at different times and these data were transferred to strain time series. This showed that strain in the Ambient pressure zone is either unchanged or slightly compressive, whereas strain in Transition zone is tensile and roughly proportional to the pressure change, and strain ranges from tensile to compressive in the Positive Pressure zone. In general, the strain is variable at the top of the Positive Pressure zone, but it appears to be consistently tensile lower in the zone. The spatial distribution of strain causes three distinct stages in the strain times series measured between pairs of CMPI reflectors. The strain is unchanged or slightly compressive during Stage 1, it increases (positive strain is tensile) approximately linearly at a rate of 0.02 to 0.03 μ/s during the Stage 2, and then flattens out in Stage 3. The strain increases again during Stage 4 of the time series. The pressure also changes in stages. It is unchanged during Stage 1 and then increases relatively rapidly at a rate of between 4 and 10 Pa/s during Stage 2 and continues to increase during Stages 3 and 4, but at a rate slightly slower than during Stage 2 (from 2.5 to 3.5 Pa/s). The rates of pressure and strain change are consistent with basic analyses. The rate of pressurization is similar to the calculated velocity of flow in the saturated zone, and this is similar to the measured velocity of the strain increase. The ratio of the pressurization rate and strain rate during Stage 2 (2.5 (Pa/s) /0.03 (μ/s)) is 80 MPa, which is approximately equal to the upper range expected considering the uniaxial compression and the Young’s Modulus of the sand. An interesting effect occurs when the upper surface of the sand becomes saturated. Significant compression (several 10s of ) occurs as the pressure and saturation increase at the upper surface. Compression occurs throughout the column, but the effect is greatest at the top of the column. The rate of compression is fastest slightly before ponding occurs, but it slows markedly and nearly stops when water starts to accumulate at the surface (ponding). This effect reverses when the surface of the sand is drained, resulting in tension throughout the column. The compression caused by this effect can be as large or larger than the tensile strain that accumulated during filling. This effect was unexpected because increasing pressure is normally associated with tensile strain. Nevertheless, this effect was observed consistently in all tests where the pressure changes at the upper surface, including tests where water was injected from below or infiltrated from above. This effect behaves as if the pore pressure at the upper surface of the sand exerts a normal force on the boundary (increasing pore pressure exerts a downward compression on the boundary). The results of these laboratory experiments indicate that CMPI can measure strain caused by fluid pressure changes in the vadose zone with a signal to noise ratio of 100 or more. Injection and drainage cause a strain signal that is complex, but repeatable. The magnitudes of the strain signal are consistent with magnitudes that are expected based on poroelastic calculations using independently measured properties of the sand. These results indicate that the CMPI technique with an optical fiber laminated in a polyester ribbon generates data that represent the strain distribution during hydrologic processes of imbibition and drainage in variably saturated sand. This suggests that distributed strain measurements using CMPI could be a viable approach for evaluating processes in the vadose zone, laying the groundwork for future field implementation.

47 OTHER INSTRUMENTATION↗