Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

What Is the Limit of Quantification for the Minor Phase in Time-of-Flight Neutron Diffraction? A Case Study on Fe and Ni Powder Mixtures at VULCAN

A phase present in small quantities within materials may not simply serve as a secondary component; it can play a crucial role in determining the integrity, properties, and performance of the material. These minor but important phases usually draw attention in material design and processing for fundamental understanding as well as material quality control. Accurately quantifying a minor phase amid a majority phase, especially at extremely low fractions, remains a challenging task. Time-of-flight neutron diffraction, coupled with advanced pattern analysis techniques like Rietveld refinement, is a powerful tool for crystal structure identification and phase quantification. The deep penetrating capability of neutrons enables the detection and quantification of trace phases within materials. In this study, the quantification limits of time-of-flight neutron diffraction were explored using the VULCAN diffractometer at the Spallation Neutron Source, using Fe–Ni powder mixtures as a sample system. By comparing the refinement results to the known weighed values, it was determined that the reliable quantification of a minor Ni phase is achievable down to about 0.1 wt% while a Ni fraction as low as 0.02 wt% is difficult to trace. Effective control of the refinement parameters, especially the profile function parameters, are found to significantly influence the convergence of fittings and the accuracy of phase quantification.

Rietveld refinement↗

ESAC (EQ-SANS Assisting Chatbot): Application of large language models and retrieval-augmented generation for enhanced user experience at EQ-SANS

Neutron scattering experiments have played vital roles in exploring materials properties in the past decades. While user interfaces have been improved over time, neutron scattering experiments still require specific knowledge or training by an expert due to the complexity of such advanced instrumentation and the limited number of experiments each person may perform each year. This paper introduces an innovative chatbot application that leverages Large Language Models(LLM) and Retrieval-Augmented Generation (RAG) technologies to significantly enhance the user experience at the EQ-SANS, a small-angle neutron scattering instrument at the Spallation Neutron Source of Oak Ridge National Laboratory. Through a user-centric design approach, the EQ-SANS Assisting Chatbot (ESAC) serves as an interactive reference for users, thereby facilitating the use of the instrument by visiting scientists. By bridging the gap between the users of EQ-SANS and the control systems required to perform their experiments, the ESAC sets a new standard for interactive learning and support for the scientific community using large-scale scientific facilities.

97 MATHEMATICS AND COMPUTING↗

Unlocking hidden information in sparse small-angle neutron scattering measurements

Hypothesis Small-Angle Neutron Scattering (SANS) is a powerful technique for studying soft matter systems such as colloids, polymers, and lyotropic phases, providing nanoscale structural insights. However, its effectiveness is limited by low neutron flux, leading to long acquisition times and noisy data. Here, we hypothesize that Bayesian statistical inference using Gaussian Process Regression (GPR) can reconstruct high-fidelity scattering data from sparse measurements by leveraging intensity smoothness and continuity. Experiments and Simulations The method was benchmarked computationally and validated through SANS experiments on various soft matter systems, including wormlike micelles, colloidal suspensions, polymeric structures, and lyotropic phases. GPR-based inference was applied to both experimental and synthetic data to evaluate its effectiveness in noise reduction and intensity reconstruction. Findings GPR significantly enhances SANS data quality and therefore reducing measurement times by up to two orders of magnitude. This cost-effective approach maximizes experimental efficiency, enabling high-throughput studies and real-time monitoring of dynamic systems. It is particularly beneficial for weakly scattering and time-sensitive studies. Beyond SANS, this framework applies to other low-SNR techniques, including laboratory-based small-angle X-ray scattering and various dynamical scattering methods. Furthermore, it offers transformative potential for compact neutron sources, enhancing their viability for structural analysis in resource-limited settings.

Small angle neutron scattering↗

Sub-millimeter resolution SiPM-based neutron anger camera

Thermal and cold neutron beamlines require detector systems that have a high neutron efficiency, large active area, and good spatial resolution. One type of detector that has been implemented at beamlines at the Spallation Neutron Source (SNS) is a scintillator-based Anger camera that utilizes photomultiplier tubes (PMTs) as photodetectors. In this work, we present a new Anger camera design that replaces PMTs with silicon photomultipliers (SiPMs). This new design offers better resolution, less distortion, and more compactness than the previous cameras. A camera with active area of ~100 cm 2 was shown to have a spatial resolution better than 0.5 mm. Additionally, the use of SiPMs allows for use in strong magnetic fields, opening the possibility of additional experimental capabilities. In conclusion, prototype has been built that demonstrates vacuum-compatibility, as required for a proposed beamline for the Second Target Station at SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Understanding Materials Characteristics of Palladium Lanthanide Cermet Wires as a Mimic of Californium Wire Production

Californium-252 (Cf-252) has been synthesized on a large scale (mg) since the 1970s for use as a portable neutron source. With a half-life of 2.645 years and a spontaneous fission fraction of 3.09%, Cf-252 emits 2.31 × 10 12 neutrons/gram second. Today most of the Cf-252 produced in the world is made at Oak Ridge National Laboratory (ORNL) using the High Flux Isotope Reactor (HFIR) and the Radiochemical Engineering Development Center (REDC). Because of its highly radioactive nature, all manipulations of Cf-252 need to be performed in hot cell facilities by highly trained personnel. The Cf-252 produced at ORNL is done at the REDC, which is conveniently located next to the HFIR. Cf-252 is sold as bulk wire, which has been described as palladium (Pd) metal incasing californium oxide (Cf 2 O 3 ). The process was developed by Mosley et al. at Savannah River Laboratory (SRL) where it was modeled after the thorium work done by Fuschillo et al. This process has been used since the 1970s to synthesize this unique wire, but its fundamental chemistry and materials characteristics were never openly reported. Here we aim to better understand the chemistry and the materials characteristics of Cf-252 wire production for process improvements and to better our fundamental understanding of the mid-late actinides. Though there are many challenges in working with radioactive elements such as Cf, the isotope Cf-252 is even more complicated due to its neutron emission. One challenge with neutron emission is the ability of neutrons to penetrate much deeper through materials, causing radiation damage. This makes using instrumentation to characterize the chemistry and materials properties of this process difficult. For this reason, this study will first focus on terbium (Tb) as a surrogate for Cf. Currently Tb is used as a carrier or filler in Cf production when small amounts of Cf are being processed. This, along with their similar size and charge, makes Tb a reasonable surrogate for this study.

36 MATERIALS SCIENCE↗

Inelastic Neutron Scattering Data for FeSn

Inelastic neutron scattering data from FeSn collected with the SEQUOIA spectrometer at the Spallation Neutron Source located at Oak Ridge National Laboratory. A 4.43 g sample of FeSn was used for the measurements as described in doi: https://doi.org/10.1103/PhysRevB.105.L180403 and the associated supplemental information. The data were collected with an incident energy of 500 meV. The Fermi chopper frequency was 480 Hz, which provides a resolution of 38.2 meV (FWHM) for elastic scattering. Additional details are available in https://doi.org/10.1103/PhysRevB.105.L180403 and the associated supplemental information. The data may be viewed and analyzed with the software packages Mantid (http://dx.doi.org/10.5286/SOFTWARE/MANTID) and Dave (doi: 10.6028/jres.114.025). Sample angles measured: -20 deg to 20 deg and 160 deg to 200 deg where 0 deg is defined for ki//c* Sample Orientation vectors: ‘u': '-0.0032, 0.0201, -1.0' ‘v': '-1.0, 0.0278, -0.0059'

Inelastic Neutron Scattering↗

Methodology for Generating Covariance Data of Thermal Neutron Scattering Cross Sections

This paper details and implements a framework for evaluating thermal neutron scattering cross sections that provide S(α,β) data and covariance data for hydrogen in light water. This methodology involves perturbing model parameters of molecular dynamics potentials and fitting the simulation results to experimental data. The framework is general and can be applied to any material or simulation method. The fit is made using the Unified Monte Carlo method to experimentally measure double-differential scattering cross sections of light water at the Spallation Neutron Source at Oak Ridge National Laboratory. Mean values and covariance data were generated for model parameters, phonon density of states, double-differential cross sections, and total scattering cross sections. These posterior parameter values were very similar to their prior values with a maximum relative error of 0.54%. This falls within in the Unified Monte Carlo–calculated uncertainties on the order of 2.7%. Additionally, posterior double-differential cross sections agree favorably with ENDF/B-VIII.0 cross sections. The new thermal scattering law was tested by comparing it against benchmarks from the International Criticality Safety Benchmark Evaluation Project Handbook, which showed a slight improvement over the ENDF/B-VIII.0 library. Additionally, the covariance matrix of the phonon density of states was validated to confirm that the spread of k eff from the density of states used to generate the covariance matrix was similar to the spread of k eff from the density of states of the sampled covariance matrix.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PIONEER, a high-resolution single-crystal polarized neutron diffractometer

PIONEER is a high Q-resolution, single-crystal, polarized neutron diffractometer at the Second Target Station (STS), Oak Ridge National Laboratory. It will provide the unprecedented capability of measuring tiny crystals (0.001 mm 3 , i.e., x-ray diffraction size), ultra-thin films (10 nm thickness), and weak structural and magnetic transitions. PIONEER benefits from the increased peak brightness of STS cold-neutron sources and uses advanced Montel mirrors that are able to deliver a focused beam with a high brilliance transfer, a homogeneous profile, and a low background. Monte Carlo simulations suggest that the optimized instrument has a high theoretical peak brilliance of 2.9 × 10 12 n cm -2 sr -1 Å -1 s -1 at 2.5 Å at the sample position, within a 5 × 5 mm 2 region and a ±0.3° divergence range. The moderator-to-sample distance is 60 m, providing a nominal wavelength band of 4.3 Å with a wavelength resolution better than 0.2% in the wavelength range of 1.0–6.0 Å. PIONEER is capable of characterizing large-scale periodic structures up to 200 Å. With a sample-to-detector distance of 0.8 m, PIONEER accommodates various sample environments, including low/high temperature, high pressure, and high magnetic/electric field. Additionally, a large cylindrical detector array (4.0 sr) with a radial collimator is planned to suppress the background scattering from sample environments. Bottom detector banks provide an additional 0.4 sr coverage or can be removed if needed to accommodate special sample environments. We present virtual experimental results to demonstrate the scientific performance of PIONEER in measuring tiny samples.

47 OTHER INSTRUMENTATION↗

Phonon density of states in uranium Laves phases UNi 2 and UCo 2

Recent computational work evaluated the phase stability of UCo 2 and UNi 2 in the C14, C15, and C36 Laves phases and reported their computationally determined phonon density of states. To corroborate these computational findings, we report the experimentally determined phonon density of states for UCo 2 and UNi 2 using inelastic neutron scattering at the wide angular-range chopper spectrometer at the Spallation Neutron Source at Oak Ridge National Laboratory. We found excellent agreement between experimental and computational results for UNi 2 and noted that some differences were observed for UCo 2 . Furthermore, by comparing the phonon density of states of UCo 2 with that of other U-bearing Laves phases, we found that UCo 2 showed distinct vibrational properties. From the one-phonon density of states, we calculated the lattice contribution to the specific heat of UNi 2 and UCo 2 . Finally, we bound the electronic contribution to the specific heat in UNi 2 .

Actinides↗

Design and Characterization of an Optically Segmented Single Volume Scatter Camera Module

Here, the optically segmented single volume scatter camera (OS-SVSC) aims to image neutron sources for nuclear nonproliferation applications using the kinematic reconstruction of elastic double-scatter events. We report on the design, construction, and calibration of one module of a new prototype. The module includes 16 EJ-204 organic plastic scintillating bars individually wrapped in Teflon tape, each measuring 0.5cx0.5cmx20cm . The scintillator array is coupled to two custom silicon photomultiplier (SiPM) boards consisting of a 2x8 array of SensL J-Series-60035 SiPMs, which are read out by a custom 16 channel DRS4 based digitizer board. The electrical crosstalk between SiPMs within the electronics chain is measured as 0.76%±0.11% among all 16 channels. We report the detector response of one module including interaction position, time, and energy, using two different optical coupling materials: EJ-560 silicone rubber optical coupling pads and EJ-550 optical coupling grease. We present results in terms of the overall mean and standard deviation of the z -position reconstruction and interaction time resolutions for all 16 bars in the module. We observed the 1σz -position resolution for gamma interactions in the 0.3–0.4 MeVee range to be 2.24 cm ± 1.10 cm and 1.45 cm ± 0.19 cm for silicone optical coupling pad and optical grease, respectively. The observed 1σ interaction time resolution is 265 ps ± 29 ps and 235 ps ± 10 ps for silicone optical coupling pad and optical grease, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Software Framework for Federated Science Instruments

There is an unprecedented promise of enhanced capabilities for federations of leadership computing systems and experimental science facilities by leveraging software technologies for fast and efficient operations. These federations seek to unify different science instruments, both computing and experimental, to effectively support science users and operators to execute complex workflows. The FedScI project addresses the software challenges associated with the formation and operation of federated environments by leveraging recent advances in containerization of software and softwarization of hardware. We propose a software framework to streamline the federation usage by science users and it’s provisioning and operations by facility providers. A distinguishing element of our work is the support for improved interaction between experimental devices, such as beam-line instruments, and more traditional high-performance computing resources, including compute, network, storage systems. We present guiding principles for the software framework and highlight portions of a current prototype implementation. We describe our science use case involving neutron imaging beam-lines (SNAP/BL-3, Imaging/CG-1D) at the Spallation Neutron Source and High Flux Isotope Reactor facilities at Oak Ridge National Laboratory. Additionally, we detail plans for a more direct instrument interaction within a federated environment, which could enable more advanced workflows with feedback loops to shorten the time to science.

Naughton III, Thomas↗

Secure Collaborative Environment for Seamless Sharing of Scientific Knowledge

In a secure collaborative environment, tera-bytes of data generated from powerful scientific instruments are used to train secure machine learning (ML) models on exascale computing systems, which are then securely shared with internal or external collaborators as cloud-based services. Devising such a secure platform is necessary for seamless scientific knowledge sharing without compromising individual, or institute-level, intellectual property and privacy details. By enabling new computing opportunities with sensitive data, we envision a secure collaborative environment that will play a significant role in accelerating scientific discovery. Several recent technological advancements have made it possible to realize these capabilities. In this paper, we present our efforts at ORNL toward developing a secure computation platform. We present a use case where scientific data generated from complex instruments, like those at the Spallation Neutron Source (SNS), are used to train a differential privacy enabled deep learning (DL) network on Summit, which is then hosted as a secure multi-party computation (MPC) service on ORNL’s Compute and Data Environment for Science (CADES) cloud computing platform for third-party inference. In this feasibility study, we discuss the challenges involved, elaborate on leveraged technologies, analyze relevant performance results and present the future vision of our work to establish secure collaboration capabilities within and outside of ORNL.

Yoginath, Srikanth↗

Search for light mediators in the low-energy data of the CONNIE reactor neutrino experiment

The CONNIE experiment is located at a distance of 30 m from the core of a commercial nuclear reactor, and has collected a 3.7 kg-day exposure using a CCD detector array sensitive to an~1 keV threshold for the study of coherent neutrino-nucleus elastic scattering. Here we demonstrate the potential of this low-energy neutrino experiment as a probe for physics Beyond the Standard Model, by using the recently published results to constrain two simplified extensions of the Standard Model with light mediators. We compare the new limits with those obtained for the same models using neutrinos from the Spallation Neutron Source. Our new constraints represent the best limits for these simplified models among the experiments searching for CE$ν$NS for a light vector mediator with mass $ {M}_{Z^{\prime }} $< 10 MeV, and for a light scalar mediator with mass M$_{\phi}$< 30 MeV. These results constitute the first use of the CONNIE data as a probe for physics Beyond the Standard Model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Potential defect structure effects in the volatility separation of sub-picogram quantities of fission and activation products from an irradiated UO2 matrix

Here, the use of fluorination as a rapid separation technique for quantification of trace-mass, short-lived isotopes is illustrated. Single crystal 238 UO 2 was exposed to a 14 MeV neutron source to produce mixed fission and activation products. Selective removal of trace volatile fluorides from non-volatile ones produced two results of interest. A decrease in background produced better detection and quantification of select analytes across the gamma spectrum. Second, at the very low burnup condition described, the volatility behaviors of common isotopes were altered relative to their well-established behaviors in higher burnup metal and metal oxide fuels.

Fission and activation product separations↗

A New Method for Polishing Laminated Dissimilar Metals

Here, this paper presents a novel method for preparing metallographic samples of laminated dissimilar metals, specifically a layered structure of zirconium (Zr), vanadium (V), and tungsten (W), which pose a challenge due to their differing crystal structures and hardness levels. The work was motivated by the need to develop a cladding for tungsten targets in spallation neutron sources, where a zirconium face is applied over an interlayer of either vanadium or titanium to prevent the formation of brittle intermetallic compounds such as ZrW 2 . Traditional polishing techniques prove inadequate because each constituent metal requires a different polishing approach based on its unique material properties. The methodology outlined includes a sequential process involving conductive epoxy mounting, successive grinding and polishing with specific abrasives, and a final chemical-mechanical polish using a colloidal silica-based solution. Optical microscopy confirmed that this multi-step process successfully produced scratch-free surfaces and minimized surface relief across the different metal interfaces. Although developed for refractory metals, this approach shows promise for other layered structures comprised of transition metals, offering a meticulous yet effective technique for high-quality metallographic sample preparation.

Newberry, Daniel [Oak Ridge National Laboratory (O↗

Corrosion in Other Liquid Metals (Li, PbLi, Hg, Sn, Ga)

A wide range of liquid metals have been considered for application in nuclear fission and fusion reactors. Liquid mercury (Hg) was tested as a coolant and working fluid for nuclear fission reactors and as a neutron source target. Liquid lithium and lead lithium eutectic (Li and PbLi) have been extensively studied for fusion reactor designs including plasma facing components (PFCs). Liquid tin and gallium (Sn and Ga) have recently gained attention as alternative PFCs due to their low vapor pressure and chemical stability. To enable successful application of these less common liquid metals, corrosion compatibility with containment materials needs to be investigated. For this purpose, this article reviews corrosion behavior and structural material compatibility, including ferrous alloys, refractory metals, and ceramics, by liquid Li, PbLi, Sn, Ga, and Hg.

Jun, Jiheon↗

Comparison of ablators for the polar direct drive exploding pusher platform

In this work, we examine the performance of pure boron, boron carbide, high density carbon, and boron nitride ablators in the polar direct drive exploding pusher (PDXP) platform. The platform uses the polar direct drive configuration at the National Ignition Facility to drive high ion temperatures in a room temperature capsule and has potential applications for plasma physics studies and as a neutron source. The higher tensile strength of these materials compared to plastic enables a thinner ablator to support higher gas pressures, which could help optimize its performance for plasma physics experiments, while ablators containing boron enable the possibility of collecting additional data to constrain models of the platform. Applying recently developed and experimentally validated equation of state models for the boron materials, we examine the performance of these materials as ablators in 2D simulations, with particular focus on changes to the ablator and gas areal density, as well as the predicted symmetry of the inherently 2D implosion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

2D kinetic-ion simulations of inverted corona fusion targets

Laser-driven “inverted corona” fusion targets have attracted interest as a low-convergence neutron source and platform for studying kinetic physics. The scheme consists of a hollow or gas-filled spherical shell made of deuterated plastic. The shell has one or more laser entrance holes (LEH), resembling a spherical hohlraum. The laser passes through the LEH’s and illuminates the interior surface of the shell, ablating a plasma that travels inward towards the target center. Long ion mean free paths in the converging plasma can lead to significant interpenetration, atomic mix, and other kinetic effects. Here, in this work we report on numerical simulations of inverted corona targets using the kinetic-ion, fluid–electron hybrid particle-in-cell (PIC) approach in 2D RZ geometry. 2D simulations suggest that shape effects do not have a significant impact on plasma evolution and observed yield trends are primarily the result of 1D kinetic mix mechanisms. Simulations are also compared against available experimental data recorded at the OMEGA laser facility. In particular, synthetic x-ray emission images show good qualitative agreement with experimental results, albeit with an apparent timing discrepancy for the two-sided vacuum target. More generally, we demonstrate the potential of hybrid-PIC simulations for full-system modeling and experimental design, including collisional absorption of laser energy, plasma evolution, mix, and fusion burn.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗