Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRON SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Neutron influences and energy spectra in the Cosmos-2044 biosatellite orbit

Joint Soviet-American measurements of the neutron component of space radiation (SR) were carried out during the flight of the Soviet biosatellite Cosmos-2044. Neutron flux densities and differential energy spectra were measured inside and on the external surface of the spacecraft. Three energy intervals were employed: thermal (E(sub n) less than or equal to 0.2 eV), resonance (0.2 eV less than E(sub n) less than 1.0 MeV) and fast (E(sub n) greater than or equal to 1.0 MeV) neutrons. The first two groups were measured with U.S. (6)LiF detectors, while fast neutrons were recorded both by U.S. fission foils and Soviet nuclear emulsions. Estimations were made of the contributions to absorbed and equivalent doses from each neutron energy interval and a correlation was presented between fast neutron fluxes, measured outside the satellite, and the phase of solar activity (SA). Average dose equivalent rates of 0.018 and 0.14 mrem d(exp -1) were measured for thermal and resonance neutrons, respectively, outside the spacecraft. The corresponding values for fast neutrons were 3.3 (U.S.) and 1.8 (U.S.S.R.) mrem d(exp -1). Inside the spacecraft, a value of 3.5 mrem d(exp -1) was found.

Dudkin, V. E.↗

Digitized two-parameter spectrometer for neutron-gamma mixed field

This paper shows the results of digital processing of output pulses from combined photon-neutron detector using a commercially available digitizer ACQUIRIS DP 210. The advantage of digital processing is reduction of the apparatus in weight and size, acceleration of measurement, and increased resistance to pile-up of pulses. The neutron and photon spectrum of radionuclide source {sup 252}Cf is presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron production in lunar habitats - Paper 132

Lunar habitats constructed of either local materials or conventional materials used for spacecraft (such as aluminum) will provide protection for astronauts from solar energetic particles (SEP) and galactic cosmic rays (GCR). Although there are essentially no neutrons in the primary GCR and SEP fields, neutrons are produced by interactions of those fields with the lunar surface and with the lunar habitat. In a habitat, the neutrons can be divided into two categories: albedo neutrons moving generally upward through the habitat, and a generally downward flux created by interactions in the habitat walls. These two neutron fields differ in their energy spectrum, and as a result different mitigation strategies may be needed for different areas of the habitat in order to reduce the dose from neutrons. In this work, we calculate the 'upward' and 'downward' neutron fluences, using a variety of shielding materials and thicknesses. We also investigate the effect of other materials inside the habitat on the neutron fluences. The preliminary transport model calculations performed here verify the effectiveness of a hydrogenous shielding wall material, polyethylene, in reducing the neutron dose inside a simple lunar habitat geometry when compared to walls made of lunar regolith and aluminum. Separate transport model calculations were done for the albedo neutron spectrum rising up from the lunar soil and for GCR particles incident upon the habitat shielding. In the case of GCR ions incident on the habitat, shielding wall made of polyethylene reduced the neutron effective dose by a factor of three, compared to the other two shielding materials. (authors)

36 MATERIALS SCIENCE↗

Influence of defects formed by fast reactor neutrons on exciton luminescence spectra of cadmium sulfide single crystals

The influence of clusters of defects formed by irradiation with neutrons in CdS single crystals on parameters of the spectra of exciton photoluminescence at T {approx} 4.2 K has been studied. It is experimentally established that irradiation of the samples with fast reactor neutrons with energies E {approx} 1 MeV and dose {Phi} = 3 x 10{sup 18} cm{sup -2} brings about a decrease (by approximately 50 times) in the intensity of lines of exciton photoluminescence I{sub 1} ({lambda}{sub m} = 488.7 nm), I{sub 2} ({lambda}{sub m} = 486.9 nm), and I{sub 3} ({lambda}{sub m} = 486.3 nm) with redistribution of intensities in favor of the lines I{sub 1} and I{sub 3} and an increase in their half-width from 2 to 5-6 the positions of their peaks in the emission spectrum. Observed experimental facts are explained on the basis of a model of a two-phase system composed of slightly damaged region in the CdS single crystal in which clusters of defects (formed as a result of irradiation with neutrons) are embedded; these clusters are nanosized grains with a highly disordered structure.

36 MATERIALS SCIENCE↗

SU-E-T-329: Tissue-Equivalent Phantom Materials for Neutron Dosimetry in Proton Therapy

Purpose: To characterize tissue equivalence of phantom materials in terms of secondary neutron production and dose deposition from neutrons produced in radiation therapy phantom materials in the context of proton therapy using Monte Carlo simulations and measurements. Methods: In order to study the influence of material choice on neutron production in therapeutic proton beams, Monte Carlo simulations using the Geant4 and MCNPX-PoliMi transport codes were performed to generate the neutron fields produced by protons of 155 and 200 MeV. A simple irradiation geometry was used to investigate the effect of different materials. The proton beams were stopped in slab phantoms to study the production of secondary neutrons. The investigated materials were water, Lucite, and tissue-equivalent phantom materials (CIRS Inc., Norfolk, VA). Neutron energy spectra and absorbed dose by neutrons and their secondary particles were scored. In addition, simulations were performed for reference tissues (ICRP/ICRU) to assess tissue equivalence with respect to neutron generation and transport. In order to benchmark the simulation results, measurements were performed with a system developed at the University of Michigan; organic liquid scintillators were used to detect the neutron emissions from the irradiation of tissue-equivalent materials. Additionally, the MPPost code was used to calculate the scintillator response from the MCNPX-PoliMi output. Results: The simulated energy spectra and depth dose curves of the neutrons produced in different phantom materials showed similar shape. The differences of spectra and fluences between all studied materials and reference tissues were well within the achievable precision of neutron dosimetry. The shape of the simulated detector response of the liquid scintillators agreed well with measurements on the proton beamline. Conclusion: Based on Geant4 and MCNPX-PoliMi simulations, the investigated materials appear to be suitable to study the production of neutrons in proton therapy. MC simulations were verified with neutron measurements in therapeutic proton beams. This work was funded in part by the ANDANTE grant of the European Commission in the 7th Framework Program.

07 ISOTOPE AND RADIATION SOURCES↗

SNS Sample Activation Calculator Flux Recommendations and Validation

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) uses the Sample Activation Calculator (SAC) to calculate the activation of a sample after the sample has been exposed to the neutron beam in one of the SNS beamlines. The SAC webpage takes user inputs (choice of beamline, the mass, composition and area of the sample, irradiation time, decay time, etc.) and calculates the activation for the sample. In recent years, the SAC has been incorporated into the user proposal and sample handling process, and instrument teams and users have noticed discrepancies in the predicted activation of their samples. The Neutronics Analysis Team validated SAC by performing measurements on select beamlines and confirmed the discrepancies seen by the instrument teams and users. The conclusions were that the discrepancies were a result of a combination of faulty neutron flux spectra for the instruments, improper inputs supplied by SAC (1.12), and a mishandling of cross section data in the Sample Activation Program for Easy Use (SAPEU) (1.1.2). This report focuses on the conclusion that the SAPEU (1.1.2) beamline neutron flux spectra have errors and are a significant contributor to the activation discrepancies. The results of the analysis of the SAPEU (1.1.2) flux spectra for all beamlines will be discussed in detail. The recommendations for the implementation of improved neutron flux spectra in SAPEU (1.1.3) are also discussed.

43 PARTICLE ACCELERATORS↗

Stellar (n, gamma) cross sections of neutron-rich nuclei

The present measurements were performed by means of the activation technique. Neutrons were produced at the Karlsruhe Van de Graaff accelerator via the {sup 7}Li(p,n){sup 7}Be reaction. For proton energies just above threshold, one obtains a neutron spectrum similar to a Maxwellian distribution for kT = 25 keV. This quasi-stellar neutron spectrum allowed us to measure the Maxwellian averaged cross sections directly. The experimental results of {sup 174,176}Yb, {sup 184,186}W, {sup 190,192}Os, {sup 196,198}Pt, and {sup 202}Hg were extrapolated from kT = 25 keV to lower and higher temperatures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of neutron emission and neutron energy spectrum calculations on a Mega Ampere Spherical Tokamak with directional relativistic spectrum simulator

The recently developed directional relativistic spectrum simulator (DRESS) code has been validated for the first time against numerical calculations and experimental measurements performed on the Mega Ampere Spherical Tokamak . In this validation, the neutron emissivities and rates computed by DRESS are benchmarked against TRANSP/NUBEAM predictions while the neutron energy spectra provided by DRESS taking as input TRANSP/NUBEAM and ASCOT/BBNBI in Gyro-Orbit mode fast ion distributions are validated against proton pulse height spectra measured by the neutron flux monitor. Finally, excellent agreement was found between DRESS and TRANSP/NUBEAM predictions of local and total neutron emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-frequency detection of the formation and stabilization of a radiation-induced defect cluster in semiconductor structures

The processes of the formation and stabilization of a radiation-induced defect cluster upon the arrival of a fast neutron to the space-charge region of a semiconductor diode are analyzed. The current pulse formed by secondary electrons is calculated and the spectrum of the signal generated by the diode (detector) under the action of an instantaneous neutron flux of the fission spectrum is determined. The possibility of experimental detection of the picosecond radiation-induced transition processes is discussed.

36 MATERIALS SCIENCE↗

Design of the Next Generation Spallation Target

The purpose of this summary is to detail the studies that enable new nuclear physics experiments currently limited by neutron intensity or energy resolution available at LANSCE. The target is being redesigned so that the Flight Paths (FP) in the upper tier provide a higher intensity in the epithermal and medium energy ranges.

43 PARTICLE ACCELERATORS↗

Redistribution of subsurface neutrons caused by ground ice on Mars

The purpose of this study is to build on that of Squyres and Evans to approach the specific problem of the buried ice deposits explored by Mellon and Jakosky. Therefore, we calculated the depth dependence of equilibrium neutron energy spectra and related neutron-capture gamma ray production rates for a semi-infinite layer of regolith having a Chryse-fines composition containing 5, 10, and 18 wt percent of water. This high water-content layer was buried beneath the same regolith containing 1 percent water at depths of 20, 40, and 80 g/ sq. cm. A 16-g/sq. cm atmosphere having the abundances measured by Owen et al. was included throughout. We also calculated the effects of a 30-g/sq. cm-thick layer containing 18 percent water embedded within a semi-finite regolith containing 1 percent water, at depths of 20, 40, and 80 g/sq. cm below the atmosphere-surface interface.

Feldman, W. C.↗

Optimization of Neutron Spectrum in Northwest Beam Tube of Tehran Research Reactor for BNCT, by MCNP Code

In order to gain the neutron spectrum with proper components specification for BNCT, it is necessary to design a Beam Shape Assembling (BSA), include of moderator, collimator, reflector, gamma filter and thermal neutrons filter, in front of the initial radiation beam from the source. According to the result of MCNP4C simulation, the Northwest beam tube has the most optimized neuron flux between three north beam tubes of Tehran Research Reactor (TRR). So, it has been chosen for this purpose. Simulation of the BSA has been done in four above mentioned phases. In each stage, ten best configurations of materials with different length and width were selected as the candidates for the next stage. The last BSA configuration includes of: 78 centimeters of air as an empty space, 40 centimeters of Iron plus 52 centimeters of heavy-water as moderator, 30 centimeters of water or 90 centimeters of Aluminum-Oxide as a reflector, 1 millimeters of lithium (Li) as thermal neutrons filter and finally 3 millimeters of Bismuth (Bi) as a filter of gamma radiation. The result of Calculations shows that if we use this BSA configuration for TRR Northwest beam tube, then the best neutron flux and spectrum will be achieved for BNCT. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Production of Neutrons by Transport of a GCR Solar Minimum Spectrum through Shielding - Paper 112

The requirements for radiation instrumentation in space can be quite different from those used for terrestrial applications. For example, most neutron instruments used for dosimetry applications used on Earth are sensitive to fission neutron energies and lower, and as such are only useful for neutron energies below 20 to 50 MeV. In space, neutrons are created by galactic cosmic ray (GCR) and solar energetic particle (SEP) interactions in materials, and as such can attain TeV energies and higher. The purpose of this study is to determine the significance of the flux of high energy neutrons in space, and to what degree neutron instruments in space must be sensitive to those high energy neutrons. PHITS transport code calculations of secondary neutron production through various thicknesses of aluminum and water shielding indicate that a significant fraction of the neutron flux and neutron effective dose comes from neutrons above 20 MeV. Measurement of high energy neutrons in space is a difficult task, especially given that the measurement will take place in a mixed radiation field where any signal from an incident neutron must be separated from signals generated by gamma rays, electrons and charged hadrons. Conventional neutron detection methodology dictates that the ability to detect high energy neutrons with a sufficient efficiency depends on the mass of the neutron detector, to first order. The more mass a neutron detector has, the higher the probability of detecting a high energy neutron. However, adding mass comes at a premium in space, often adding costs that prohibit the implementation of a new design with more mass. Thus, to accurately measure the effective dose to humans in space from secondary neutron irradiation, it requires novel methodologies that can stretch the limits of low-mass neutrons detectors, such as developing versatile response functions that are well characterized and can function over a wide range of very different neutron energy spectra. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Velocity-space sensitivity of the time-of-flight neutron spectrometer at JET

The velocity-space sensitivities of fast-ion diagnostics are often described by so-called weight functions. Recently, we formulated weight functions showing the velocity-space sensitivity of the often dominant beam-target part of neutron energy spectra. These weight functions for neutron emission spectrometry (NES) are independent of the particular NES diagnostic. Here we apply these NES weight functions to the time-of-flight spectrometer TOFOR at JET. By taking the instrumental response function of TOFOR into account, we calculate time-of-flight NES weight functions that enable us to directly determine the velocity-space sensitivity of a given part of a measured time-of-flight spectrum from TOFOR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Which nuclear data can be validated with LLNL pulsed-sphere experiments?

It is shown here that 14-MeV D+T LLNL pulsed-sphere experiments bring complementary information into the process of validating nuclear data compared to experiments that are traditionally used for this purpose—such as critical assemblies. To be more specific, the 14-MeV D+T LLNL pulsed-sphere neutron-leakage spectra enable to validate scattering and fission nuclear data up to 15 MeV (compared to approximately up to 5 MeV when using criticality experiments) and employ to this end simple compound targets containing only few isotopes. In this work, sensitivity profiles of the spectra to nuclear data are calculated in order to understand in detail which isotopes, observables, and energy ranges of nuclear data contribute significantly to their simulation. These profiles are presented for a few selected spheres containing 16 O, 12 C, 56 Fe, and 239 Pu. It is shown that the neutron-leakage spectra of spheres containing light elements are mostly sensitive to elastic- and inelastic-scattering cross sections on discrete levels and corresponding angular distributions. Spheres of structural materials are sensitive to elastic- and inelastic-scattering cross sections, including scattering on discrete levels and the continuum, and double-differential cross sections. Actinide spheres are also strongly sensitive to the fission observables, in particular to the total-fission neutron spectrum. Thin spheres (in which neutrons experience on average less than one scatter) are mostly sensitive to data near the elastic peak, in the energy range from 12–15 MeV, while thicker ones can be sensitive to data at lower incident-neutron energies due to multiple-scattering effects. This information is brought together with simulations of 71 pulsed-sphere neutron-leakage spectra using the ENDF/B-VII.1 and ENDF/B-VIII.0 nuclear-data libraries. This analysis highlights ENDF/B-VIII.0 data that could be further investigated for potential shortcomings ( 6 Li, 12 C, 16 O, 24-26 Mg, 27 Al, 48 Ti, 56 Fe, and 208 Pb) or are likely reliable ( 1,2 H, 7 Li, 9 Be, 14 N, 235,238 U, and 239 Pu) as indicated by validating with LLNL pulsed-sphere experiments.

14-MeV D+T LLNL pulsed-sphere neutron-leakage spec↗

Improved Fission Neutron Data Base for Active Interrogation of Actinides

This project will develop an innovative neutron detection system for active interrogation measurements. Many active interrogation methods to detect fissionable material are based on the detection of neutrons from fission induced by fast neutrons or high-energy gamma rays. The energy spectrum of the fission neutrons provides data to identify the fissionable isotopes and materials such as shielding between the fissionable material and the detector. The proposed path for the project is as follows. First, the team will develop new neutron detection systems and algorithms by Monte Carlo simulations and bench-top experiments. Next, they will characterize and calibrate detection systems both with monoenergetic and white neutron sources. Finally, high-fidelity measurements of neutron emission from fissions induced by fast neutrons will be performed. Several existing fission chambers containing U-235, Pu-239, U-238, or Th-232 will be used to measure the neutron-induced fission neutron emission spectra. The challenge for making confident measurements is the detection of neutrons in the energy ranges of 0.01 – 1 MeV and above 8 MeV, regions where the basic data on the neutron energy spectrum emitted from fission is least well known. In addition, improvements in the specificity of neutron detectors are required throughout the complete energy range: they must be able to clearly distinguish neutrons from other radiations, in particular gamma rays and cosmic rays. The team believes that all of these challenges can be addressed successfully with emerging technologies under development by this collaboration. In particular, the collaboration will address the area of fission neutron emission spectra for isotopes of interest in the advanced fuel cycle initiative (AFCI).

Pozzi, Sara A.↗