Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Gain comparison in polar and nonpolar/ semipolar gallium-nitride-based laser diodes

Experimental gain spectra at continuous-wave (CW) operation of laser diodes (LDs) fabricated from c-plane, nonpolar and semipolar GaN-based materials emitting in violet, blue and green spectral regions are presented. Gain spectra were obtained using the Hakki–Paoli method at high resolution. The ability of the setup to resolve the sharp Fabry–Perot longitudinal peaks of the lasers at all injection currents allowed us to accurately measure the current density to reach transparency on the devices characterized in this work, and determine both total losses and differential modal gain curves up to threshold. We present a comparison of transparency current density and modal gain for nonpolar and c-plane LDs in violet and blue regions. The main parameters for the analysis are the internal electric fields (for c-plane lasers), hole effective masses and valence band splittings. In a preliminary analysis, we investigated the gain spectrum of semipolar green LDs and observed a significantly lower total linewidth (homogeneous plus inhomogeneous) than reported elsewhere, which seems to indicate that inhomogeneous broadening is not the main issue governing the evolution toward high performance green LDs.

36 MATERIALS SCIENCE↗

A modal approach to the numerical calculation of primordial non-Gaussianities

We propose a new method to numerically calculate higher-order correlation functions of primordial fluctuations generated from any early-universe scenario. Our key-starting point is the realization that the tree-level In-In formalism is intrinsically separable. This enables us to use modal techniques to efficiently calculate and represent non-Gaussian shapes in a separable form well suited to data analysis. We prove the feasibility and the accuracy of our method by applying it to simple single-field inflationary models in which analytical results are available, and we perform non-trivial consistency checks like the verification of the single field consistency relation. We also point out that the iε prescription is automatically taken into account in our method, preventing the need for ad-hoc tricks to implement it numerically.

79 ASTRONOMY AND ASTROPHYSICS↗

2024 Workshop - Remote Sensing and Fluxes Upscaling for Real-world Impact - Tutorial v1

The software-tutorial was developed within the 2024 Remote Sensing and Fluxes Upscaling for Real-world Impact workshop as part of the hands-on session. The workshop was supported by AmeriFlux, National Ecological Observatory Network (NEON) and CarbonDew. The software provides basic tools to perform the following tasks: - gather remote sensing images using Google Earth Engine API; - gather flux data; - perform basic functions, such as plotting time-series, perform QA of the data, compute vegetation indices; - perform correlation analysis between flux data and remote sensing data; - perform flux predictions based on remote sensing data integrated in different modalities.

Falco, Nicola [Lawrence Berkeley National Laborato↗

JacketSE: An Offshore Wind Turbine Jacket Sizing Tool; Theory Manual and Sample Usage with Preliminary Validation

This manual summarizes the theory and preliminary verifications of the JacketSE module, which is an offshore jacket sizing tool that is part of the Wind-Plant Integrated System Design & Engineering Model toolbox. JacketSE is based on a finite-element formulation and on user-prescribed inputs and design standards' criteria (constraints). The physics are highly simplified, with a primary focus on satisfying ultimate limit states and modal performance requirements. Preliminary validation work included comparing industry data and verification against ANSYS, a commercial finite-element analysis package. The results are encouraging, and future improvements to the code are recommended in this manual.

17 WIND ENERGY↗

High Temperature Additive Architectures for 65% Efficiency (Final Report)

GE Power (GEP) proposed a development program that targets advanced high temperature additive components that contribute towards the DOE’s goal for advanced gas turbines that are capable of 65%, or greater, efficiency in combined cycle application. GEP proposed to leverage state-of-the-art additive manufacturing to develop novel and innovative component airfoil and end wall architectures that provide cooling flow savings while maintaining the component durability expected in today’s gas turbines. The objective of this program was to develop advanced component designs and architectures enabled by additive manufacturing, and the materials systems and additive manufacturing technology required for these designs. This Phase I program leveraged existing design and analysis knowledge and techniques for additive materials and methods and utilized extensive analytical evaluations to develop and refine designs for advanced turbine hot gas path (HGP) components. The design will be the basis for development and testing in a potential Phase II program. The goal of this Phase I program was to establish a feasible conceptual design for advanced additive turbine hot section components along with a technology maturation plan involving testing to address risk areas and needed validation. It was approached through two primary elements: 1) conceptual design and analysis of wall architectures, advanced airfoil cooling concepts, and advanced system-level concepts, and 2) investigation of additive modalities and associated materials systems. The Phase I program has concluded with the down-select of a primary design concept for a potential Phase II program.

36 MATERIALS SCIENCE↗

SU-F-I-70: Investigation of Gafchromic EBT3 Film Energy Dependence Using Proton, Photon, and Electron Beams

Purpose: To investigate the energy dependence of Gafchromic EBT3 film over a range of clinically used proton, photon and electron energies. Methods: Proton beam energies of 117 and 204 MeV, corresponding respectively to ranges in water of 10 cm and 27 cm from a Mevion S250 double scatter system unit were used. Electron energies of 6 and 20 MeV and photon energies of 6 and 18 MV from a Varian Clinac 21EX Linac were used. Two pieces of film (5×5 cm{sup 2}) were irradiated sequentially for doses of 100, 500, and 1000 cGy for all energies and modalities. Films were placed on the central beam axis for a 10×10 cm{sup 2} field size in the middle of spread out Bragg peak (SOBP) for proton and in respective dmax for photon and electron energies. Films were scanned on a flatbed Epson Expression 10000 XL scanner on the central region of the scanning window using 48-bit, 300 dpi, and landscape orientation after 48 hours post-irradiation of film to account for optical density (OD) stabilization. Film analysis of the red channel was performed using ImageJ 1.48v (National Institutes of Health). Results: The energy dependency of EBT3 among all energies and modalities for all doses studied was small within measurement uncertainties (1σ = ± 4.1%). The mean net OD in red channel for films receiving the same dose in the same energy modality had standard deviations within 0.9% for photons, 4.9% for electrons and 1.8% for protons. It was observed that film pieces were activated during proton irradiation, e.g., 7 mR/hr at surface after 30 minutes of irradiation, lasting for 2 hours post irradiation. Conclusion: EBT3 energy dependency was evaluated for clinically used proton, photon, and electron energies. The film self-activation may have contributed to fog and negligible dose.

60 APPLIED LIFE SCIENCES↗

The Impact of Brachytherapy on Prostate Cancer-Specific Mortality for Definitive Radiation Therapy of High-Grade Prostate Cancer: A Population-Based Analysis

Purpose: This population-based analysis compared prostate cancer-specific mortality (PCSM) in a cohort of patients with high-risk prostate cancer after nonsurgical treatment with external beam radiation therapy (EBRT), brachytherapy (BT), or combination (BT + EBRT). Methods and Materials: We identified from the Surveillance, Epidemiology and End Results database patients diagnosed from 1988 through 2002 with T1-T3N0M0 prostate adenocarcinoma of poorly differentiated grade and treated with BT, EBRT, or BT + EBRT. During this time frame, the database defined high grade as prostate cancers with Gleason score 8-10, or Gleason grade 4-5 if the score was not recorded. This corresponds to a cohort primarily with high-risk prostate cancer, although some cases where only Gleason grade was recorded may have included intermediate-risk cancer. We used multivariate models to examine patient and tumor characteristics associated with the likelihood of treatment with each radiation modality and the effect of radiation modality on PCSM. Results: There were 12,745 patients treated with EBRT (73.5%), BT (7.1%), or BT + EBRT (19.4%) included in the analysis. The median follow-up time for all patients was 6.4 years. The use of BT or BT + EBRT increased from 5.1% in 1988-1992 to 31.4% in 1998-2002. Significant predictors of use of BT or BT + EBRT were younger age, later year of diagnosis, urban residence, and earlier T-stage. On multivariate analysis, treatment with either BT (hazard ratio, 0.66; 95% confidence interval, 0.49-0.86) or BT + EBRT (hazard ratio, 0.77; 95% confidence ratio, 0.66-0.90) was associated with significant reduction in PCSM compared with EBRT alone. Conclusion: In patients with high-grade prostate cancer, treatment with brachytherapy is associated with reduced PCSM compared with EBRT alone. Our results suggest that brachytherapy should be investigated as a component of definitive treatment strategies for patients with high-risk prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Seed-based transrectal ultrasound-fluoroscopy registration method for intraoperative dosimetry analysis of prostate brachytherapy

Prostate brachytherapy is an effective treatment option for early-stage prostate cancer. During a prostate brachytherapy procedure, transrectal ultrasound (TRUS) and fluoroscopy imaging modalities complement each other by providing good visualization of soft tissue and implanted seeds, respectively. Therefore, the registration of these two imaging modalities, which are readily available in the operating room, could facilitate intraoperative dosimetry, thus enabling physicians to implant additional seeds into the underdosed portions of the prostate while the patient is still on the operating table. It is desirable to register TRUS and fluoroscopy images by using the seeds as fiducial markers. Although the locations of all the implanted seeds can be reconstructed from three fluoroscopy images, only a fraction of these seeds can be located in TRUS images. It is challenging to register the TRUS and fluoroscopy images by using the identified seeds, since the correspondence between them is unknown. Furthermore, misdetection of nonseed structures as seeds can lead to the inclusion of spurious points in the data set. We developed a new method called iterative optimal assignment (IOA) to overcome these challenges in TRUS-fluoroscopy registration. By using the Hungarian method in an optimization framework, IOA computes a set of transformation parameters that yield the one-to-one correspondence with minimum cost. We have evaluated our registration method at varying noise levels, seed detection rates, and number of spurious points using data collected from 25 patients. We have found that IOA can perform registration with an average root mean square error of about 0.2 cm even when the seed detection rate is only 10%. We believe that IOA can offer a robust solution to seed-based TRUS-fluoroscopy registration, thus making intraoperative dosimetry possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Model generation of coronary artery bifurcations from CTA and single plane angiography

Purpose: To generate accurate and realistic models of coronary artery bifurcations before and after percutaneous coronary intervention (PCI), using information from two image modalities. Because bifurcations are regions where atherosclerotic plaque appears frequently and intervention is more challenging, generation of such realistic models could be of high value to predict the risk of restenosis or thrombosis after stent implantation, and to study geometrical and hemodynamical changes. Methods: Two image modalities have been employed to generate the bifurcation models: computer tomography angiography (CTA) to obtain the 3D trajectory of vessels, and 2D conventional coronary angiography (CCA) to obtain radius information of the vessel lumen, due to its better contrast and image resolution. In addition, CCA can be acquired right before and after the intervention in the operation room; therefore, the combination of CTA and CCA allows the generation of realistic preprocedure and postprocedure models of coronary bifurcations. The method proposed is semiautomatic, based on landmarks manually placed on both image modalities. Results: A comparative study of the models obtained with the proposed method with models manually obtained using only CTA, shows more reliable results when both modalities are used together. The authors show that using preprocedure CTA and postprocedure CCA, realistic postprocedure models can be obtained. Analysis carried out of the Murray's law in all patient bifurcations shows the geometric improvement of PCI in our models, better than using manual models from CTA alone. An experiment using a cardiac phantom also shows the feasibility of the proposed method. Conclusions: The authors have shown that fusion of CTA and CCA is feasible for realistic generation of coronary bifurcation models before and after PCI. The method proposed is efficient, and relies on minimal user interaction, and therefore is of high value to study geometric and hemodynamic changes of treated patients.

60 APPLIED LIFE SCIENCES↗

Elucidating the corrosion mechanism of Ni-based superalloys in the presence of uranium-containing chloride molten salt

The United States Department of Energy (DOE) is committed to the advancement of nuclear reactor technology through initiatives such as the Advanced Reactor Development Program (ARDP), in an effort to diversify the United States energy portfolio towards more sustainable energy options. The ARDP includes demonstration by industry partners of molten chloride fast reactors (MCFRs). Construction of MCFRs requires qualified nuclear structural materials. Unfortunately, there are no current materials that are fully qualified by the Nuclear Regulatory Commission for the construction of molten salt reactors, including MCFRs. Adapting current structural material qualifications requires expansion of our current knowledgebase on the property-performance relationships regarding corrosion performance. In this investigation, we assess microstructural changes in a Ni-based superalloy after exposure to a UCl3¬-containing chloride salt eutectic mixture through a correlated multi-modal approach combining several advanced characterization techniques, including scanning electron microscopy/focused ion beam (SEM/FIB) and transmission electron microscopy (TEM). SEM/FIB analysis will illustrate changes in elemental composition, microstructure, and isotopic information acquired from energy x-ray dispersive spectroscopy (EDS), electron backscatter diffraction (EBSD), and secondary ion mass spectroscopy (SIMS), respectively. This information will then aid in identifying localized regions to elucidate the corrosion mechanism with TEM through a combination of electron diffraction, electron energy loss spectroscopy (EELS), and additional EDS. The findings from this investigation will further expand our assessment of the corrosion performance of structural materials in molten salt chloride systems, aiding to developing fully qualified materials for construction of MCFRs.

36 MATERIALS SCIENCE↗

SU-F-P-51: Similarity Analysis of the Linear Accelerator Machines Based On Clinical Simulation

Purpose: To evaluate the clinical rationale for Truebeam and Trilogy Linac machines from Varian Medical System as exchangeable treatment modalities in the same radiation oncology department. Methods: Intensity Modulated Radiotherapy (IMRT) plans for different diseases were selected for this study. These disease sites included brain, head and neck, breast, lung, and prostate. The parameters selected for this study were the energy amount, Monitor Unit (MU); dose coverage of target reflected by prescription isodose volume(PIV); dose spillage described by the volume of 50% isodoseline of the prescription; and dose homogeneities represented by the maximum dose (MaxD) and the minimum dose (MinD) of target volume (TV) and critical structure (CS). Each percentage difference between the values of these parameters formed an element of a matrix, which was called Similarity Comparison Matrix(SCM). The elements of the SCM were then simplified by dimensional conversion algorithm, which was used to determine clinical similarity between two machines through a single value. Results: For the selected clinical cases in this study, the average percentage differences between Trilogy and Truebeam in MU was 0.28% with standard deviation(SD) 0.66%, PIV was 0.23% with SD 0.20%, Volume at 50% prescription dose was 0.31% with SD at 0.78%, MaxD at TV is 0.26% with SD 0.35%, MinD at TV is −0.04% with SD 0.51%, MaxD in CS is −0.53% with SD 0.92%, and MinD in CS 3.31%, with SD at 2.89%. The sum, product, geometric and harmonic mean for the matrix elements were 19.0%, 0.00%, 0.19%, and 0.00%. Conclusion: A method to compare two machines in clinical level was developed and some reference values were calculated for decision-making in clinical practice, and this strategy could be expanded to different clinical applications.

60 APPLIED LIFE SCIENCES↗

Multimodal MSI in Conjunction with Broad Coverage Spatially Resolved MS2 Increases Confidence in Both Molecular Identification and Localization

One critical aspect of mass spectrometry imaging (MSI) is the need to con?dently identify detected analytes. While orthogonal tandem MS (e.g., LC-MS2) experiments from sample extracts can assist in annotating ions, the spatial information about these molecules is lost. Accordingly, this could cause mislead conclusions, especially in cases where isobaric species exhibit di?erent distributions within a sample. In this Technical Note, we employed a multimodal imaging approach, using matrix assisted laser desorption/ionization (MALDI)-MSI and liquid extraction surface analysis (LESA)-MS2I, to con?dently annotate and One critical aspect of mass spectrometry imaging (MSI) is the need to con?dently identify detected analytes. While orthogonal tandem MS (e.g., LC-MS2) experiments from sample extracts can assist in annotating ions, the spatial information about these molecules is lost. Accordingly, this could cause mislead conclusions, especially in cases where isobaric species exhibit di?erent distributions within a sample. In this Technical Note, we employed a multimodal imaging approach, using matrix assisted laser desorption/ionization (MALDI)-MSI and liquid extraction surface analysis (LESA)-MS2I, to con?dently annotate and localize a broad range of metabolites involved in a tripartite symbiosis system of moss, cyanobacteria, and fungus. We found that the combination of these two imaging modalities generated very congruent ion images, providing the link between highly accurate structural information onfered by LESA and high spatial resolution attainable by MALDI. These results demonstrate how this combined methodology could be very useful in di?erentiating metabolite routes in complex systems.

Velickovic, Dusan↗

Protons in Head-and-Neck Cancer: Bridging the Gap of Evidence

Purpose: To use Normal Tissue Complication Probability (NTCP) models and comparative planning studies to explore the (cost-)effectiveness of swallowing sparing intensity modulated proton radiotherapy (IMPT) compared with swallowing sparing intensity modulated radiotherapy with photons (IMRT) in head and neck cancer (HNC). Methods and Materials: A Markov model was constructed to examine and compare the costs and quality-adjusted life years (QALYs) of the following strategies: (1) IMPT for all patients; (2) IMRT for all patients; and (3) IMPT if efficient. The assumption of equal survival for IMPT and IMRT in the base case analysis was relaxed in a sensitivity analysis. Results: Intensity modulated proton radiation therapy and IMRT for all patients yielded 6.620 and 6.520 QALYs and cost €50,989 and €41,038, respectively. Intensity modulated proton radiation therapy if efficient yielded 6.563 QALYs and cost €43,650. The incremental cost-effectiveness ratio of IMPT if efficient versus IMRT for all patients was €60,278 per QALY gained. In the sensitivity analysis, IMRT was more effective (0.967 QALYs) and less expensive (€8218) and thus dominated IMPT for all patients. Conclusions: Cost-effectiveness analysis based on normal tissue complication probability models and planning studies proved feasible and informative and enables the analysis of individualized strategies. The increased effectiveness of IMPT does not seem to outweigh the higher costs for all head-and-neck cancer patients. However, when assuming equal survival among both modalities, there seems to be value in identifying those patients for whom IMPT is cost-effective.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment of acoustic fluid-structure interaction by Localized Lagrange Multipliers and comparison to alternative interface coupling methods.

This paper is a sequel on the topic of localized Lagrange multipliers (LLM) for applications of fluid-structure interaction (FSI) between finite-element models of an acoustic fluid and an elastic structure. The prequel paper formulated the spatial-discretization methods, the LLM interface treatment, the time-marching partitioned analysis procedures, and the application to 1D benchmark problems. Here, we expand on formulation aspects required for successful application to more realistic 2D and 3D problems. Additional topics include duality relations at the fluid-structure interface, partitioned vibration analysis, reduced-order modeling, handling of curved interface surfaces, and comparison of LLM with other coupling methods. Emphasis is given to non-matching fluid-structure meshes. We present benchmark examples that illustrate the benefits and drawbacks of competing interface treatments. Realistic application problems involving the seismic response of two existing dams are considered. These include 2D modal analyses of the Koyna gravity dam, transient-response analyses of that dam with and without reduced-order modeling, incorporation of nonlinear cavitation effects, and the 3D transient-response analysis of the Morrow Point arch dam.

13 HYDRO ENERGY↗

Extending Component Lifetime And Improving Inverter Reliability (ECLAIIR)

Inverter reliability remains one of the most persistent challenges limiting the performance, availability, and economic viability of utility‑scale photovoltaic (PV) plants. Industry data consistently show that inverters account for the highest share of corrective maintenance events and unplanned outages across PV fleets. These failures result in energy losses, increased O&M costs, and reduced confidence in long‑term solar asset performance. Motivated by these challenges, this project—Extending Component Lifetime and Improving Inverter Reliability (ECLAIIR)—was undertaken to systematically investigate inverter degradation and failure mechanisms, develop predictive maintenance capabilities, and establish data‑driven pathways to improve service life and reduce the Levelized Cost of Energy (LCOE) for large‑scale PV systems. The primary goal of the project was to identify pre‑failure signatures in string inverters using both lab‑based accelerated lifetime testing and field‑based data and to develop predictive maintenance algorithms that can anticipate inverter faults before they occur. Through collaboration with inverter testing laboratory, solar PV plant owner, and failure‑analysis experts, the project advanced the technical understanding of inverter reliability. By instrumenting inverters with thermistors, humidity sensors, power‑quality meters, and acoustic sensors, the research established how multiple sensing modalities can reliably detect deviations from normal behavior hours to days before failure. These findings substantially enhance scientific understanding of inverter failure kinetics and provide the PV industry with the most comprehensive cross‑OEM characterization of early‑stage failure indicators reported to date. Technically, the project demonstrated the effectiveness of predictive maintenance by developing and validating the PreDICT (Predictive Diagnostics of PV Inverters Using Condition Monitoring and Trend Analysis) framework—a multi‑layer diagnostic architecture combining peer‑to‑peer analytics, historical trend modeling, and advanced machine‑learning techniques such as the Sequential Conditional Variational Autoencoder (SCVAE). This predictive model achieved more than 90% accuracy in detecting pre‑failure conditions and provided up to four days of lead time before inverter failure in field scenarios. Economically, the project’s LCOE analysis showed that predictive maintenance can reduce lifetime energy losses and minimize corrective maintenance interventions. Modeling indicated that, depending on inverter failure rates and replacement timelines, predictive maintenance can significantly reduce LCOE impacts associated with inverter downtime: from as high as 19.4% under conventional maintenance strategies to 0.1%–10.17% when predictive analytics are adopted. These results confirm that predictive maintenance is both technically feasible and economically advantageous for utilities and plant operators. The project’s findings also have broad public benefit. By improving inverter reliability and reducing downtime, predictive maintenance directly increases electricity generation from existing PV assets. Enhanced reliability lowers operational costs for utilities, which can translate over time into lower energy costs for consumers. Furthermore, the project’s technical publications, conference presentations, and industry workshops ensure that knowledge gained is shared broadly across the solar industry, supporting workforce development and enabling utilities of all sizes to adopt modern asset‑health monitoring practices. The retrofitting case study and service‑life prediction framework further support informed decision‑making for aging PV fleets, helping operators extend system life and reduce electronic waste. In summary, the ECLAIIR project significantly advanced the state of knowledge on inverter degradation, demonstrated the technical and economic value of predictive maintenance, and delivered actionable tools and insights that support more reliable, cost‑effective, and sustainable PV plant operation. The outcomes of this project will continue to inform utility practices, guide inverter design improvements, and strengthen the long‑term performance of solar assets nationwide.

14 SOLAR ENERGY↗

Beam-wave interaction analysis of a magnetically insulated line oscillator

Magnetically insulated line oscillator (MILO) using a metal disc-loaded coaxial cylindrical waveguide as its RF interaction structure is field analyzed for the beam-wave interaction using the linearized Vlasov equation. The beam present dispersion relation of the device is obtained applying the modal matching technique which is further used to estimate the oscillation frequency, temporal growth rate, output energy, and other device parameters. Further, MILO is simulated using commercial pic code 'magic,' and the electron momentum and energy plots are found to be in agreement with those obtained through the present analysis within 5%. Furthermore, the device temporal growth rate reported in the literature for the experimental MILO device is also compared with the present analytical theory and found in agreement {approx}5%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi‐fidelity digital twin structural model for a sub‐scale downwind wind turbine rotor blade

Abstract This paper presents the development of a multi‐fidelity digital twin structural model (virtual model) of an as‐built wind turbine blade. The goal is to develop and demonstrate an approach to produce an accurate and detailed model of the as‐built blade for use in verifying the performance of the operating two‐bladed, downwind rotor. The digital twin model development methodology, presented herein, involves a novel calibration process to integrate a wide range of information including design specifications, manufacturing information, and structural testing data (modal and static) to produce a multi‐fidelity digital twin structural model: a detailed high‐fidelity model (i.e., 3D finite element analysis [FEA]) and consistent beam‐type models for aeroelastic simulation. A key element is that the multi‐fidelity structural digital twin method follows the rotor from the stages of design, to manufacturing, then to the ground testing and field operation. The result of this comprehensive approach is an accurate multi‐fidelity digital twin structural model for the geometric, structural, and structural dynamic properties of the as‐built blade within a 1% match in mass properties, 3.2% in blade frequencies, and 6% in deflection. The different stages of processing this information within the methodology are discussed. The rotor examined is the SUMR‐Demonstrator (SUMR‐D), which was installed on the Controls Advanced Research Testbed (CART‐2) wind turbine at the National Wind Technology Center. The digital twin model developed here was utilized to design controllers to safely operate SUMR‐D in field tests, which are providing additional data for further evaluation and development of the multi‐fidelity digital twin structural model.

Chetan, Mayank↗