Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Quantitative Structure Determination from Experimental Four-Dimensional Scanning Transmission Electron Microscopy via the Scattering Matrix

Considerable inroads have recently been made on algorithms to determine the sample potential from four-dimensional scanning transmission electron microscopy data from thick samples where multiple scattering cannot be neglected. This paper further develops the scattering matrix approach to such structure determination. Through simulation, we demonstrate how this approach can be modified to better handle partial spatial coherence, unknown probe defocus, and information from the dark field region. By combining these developments we reconstruct the electrostatic potential of a monolithic SrTiO 3 crystal showing good quantitative agreement with the expected structure.

4D STEM↗

Human-in-the-Loop: The Future of Machine Learning in Automated Electron Microscopy

Machine learning (ML) methods are progressively gaining acceptance in the electron microscopy community for de-noising, semantic segmentation, and dimensionality reduction of data post-acquisition. The introduction of the application programming interfaces (APIs) by major instrument manufacturers now allows the deployment of ML workflows in microscopes, not only for data analytics but also for real-time decision-making and feedback for microscope operation. However, the number of use cases for real-time ML remains remarkably small. Furthermore, we discuss some considerations in designing ML-based active experiments and pose that the likely strategy for the next several years will be human-in-the-loop automated experiments (hAE). In this paradigm, the ML learning agent directly controls beam position and image and spectroscopy acquisition functions, and a human operator monitors experiment progression in real and feature space of the system and tunes the policies of the ML agent to steer the experiment toward specific objectives.

47 OTHER INSTRUMENTATION↗

Fingerprints of composite fermion Lambda levels in scanning tunneling microscopy

A composite fermion (CF) is a topological quasiparticle that emerges from a nonperturbative attachment of vortices to electrons in strongly correlated two-dimensional materials. Similar to noninteracting fermions that form Landau levels in a magnetic field, CFs can fill analogous “Lambda” levels, giving rise to the fractional quantum Hall (FQH) effect of electrons. Here, we show that Lambda levels can be directly visualized through the characteristic peak structure in the signal obtained via spectroscopy with scanning tunneling microscopy (STM) on a FQH state. Complementary to transport, which probes the low-energy properties of CFs, we show that high-energy features in STM spectra can be interpreted in terms of Lambda levels. We numerically demonstrate that STM spectra can be accurately modeled using Jain's CF theory. Our results show that STM provides a powerful tool for revealing the anatomy of FQH states and identifying physics beyond the noninteracting CF paradigm.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Picosecond phase-velocity dispersion of hypersonic phonons imaged with ultrafast electron microscopy

We describe the direct imaging—with four-dimensional ultrafast electron microscopy—of the emergence, evolution, dispersion, and decay of photoexcited, hypersonic coherent acoustic phonons in nanoscale germanium wedges. Coherent strain waves generated via ultrafast in situ photoexcitation were imaged propagating with initial phase velocities of up to 35 km/s across discrete micrometer-scale crystal regions. We then observe that, while each wave front travels at a constant velocity, the entire wave train evolves with a time-varying phase-velocity dispersion, displaying a single-exponential decay to the longitudinal speed of sound (5 km/s) and with a mean lifetime of 280 ps. We also find that the wave trains propagate along a single in-plane direction oriented parallel to striations introduced during specimen preparation, independent of crystallographic direction. Elastic-plate modeling indicates the dynamics arise from excitation of a single, symmetric (dilatational) guided acoustic mode. Further, by precisely determining the experiment time-zero position with a plasma-lensing method, we find that wave-front emergence occurs approximately 100 ps after femtosecond photoexcitation, which matches well with Auger recombination times in germanium. We conclude by discussing the similarities between the imaged hypersonic strain-wave dynamics and electron/hole plasma-wave dynamics in strongly photoexcited semiconductors.

36 MATERIALS SCIENCE↗

Adaptive noise canceling for transient absorption microscopy

Significance: Ultrafast fiber lasers are an attractive alternative to bulk lasers for nonlinear optical microscopy for their compactness and low cost. The high relative intensity noise (RIN) of these lasers poses a challenge for pump-probe measurements such as transient absorption and stimulated Raman scattering, along with modalities that provide label-free contrast from the vibrational and electronic structure of molecules. Aim: Digital adaptive filtering was applied to determine the applicability for canceling laser RIN in a transient absorption microscope with an ultrafast fiber laser source. Approach: Digitized signals from the transmitted probe and reference photodetectors were fed to an adaptive filter in MATLAB, running in a noise canceling configuration. This result was then fed to a software lock-in algorithm to demodulate the pump-probe signal. Images were built up one line scan at a time with a 3.5-kHz resonant scanner, with 100× averaging. The imaging target was Bi4Ge3O12, which exhibits nondegenerate two-photon absorption at the pump/probe wavelengths used (530-nm pump and 490-nm probe). Results: Without adaptive noise cancellation, the lock-in output primarily passes the laser RIN within its detection bandwidth, resulting in images that closely follow the linear transmissivity and lack sensitivity to pump-probe time delay. With adaptive noise cancellation in front of the lock-in, the RIN rejection is enough to restore the z-sectioning and sensitivity to pump-probe delay, as expected for transient absorption. Results were limited primarily by noise from the photodetector and analog-to-digital converter. Conclusions: Digital adaptive noise cancellation, even when limited by electronics noise, can recover pump-probe signals by removal of laser RIN, under conditions where averaging alone fails.

42 ENGINEERING↗

Microscopy with ultraviolet surface excitation (MUSE) enables translation of optical biopsy principles to enhance life science education

The translation of microscopy with ultraviolet surface excitation (MUSE) into a high school science classroom is investigated with the goal of providing a suitable new modality to enhance life science education. A key part of this effort is the development of laboratory exercises that can integrate the advanced capabilities of MUSE into a classroom setting. MUSE utilizes the unique property of ultraviolet light at wavelengths between 250 and 285 nm to propagate about 10 um into tissues, thus illuminating only the top cell layer. Furthermore this illumination is provided by a low-power UV LED source, which enables one to cost-efficiently implement this method into the educational environment. MUSE in education can eliminate the need for premade microscope slides and provide a far more engaging and rewarding experience for students.

47 OTHER INSTRUMENTATION↗

In-Situ Liquid Cell Transmission Electron Microscopy of Nanoparticles from Spent Nuclear Fuel

Noble Metal Particles (NMP) that are present in SNF play an important role in the Fuel Matrix Degradation (FMD) Model that is being considered for predicting the release rate of radionuclides from a waste package. Previous characterization of chemically separated NMP from SNF showed that these were well-crystallized nanoparticles containing Mo, Tc, Ru, Rh, and Pd with some evidence of actinides. These same chemically separated particles were re-characterized following 10 years of storage as the separated material in water. Scanning Transmission Electron Microscopy (STEM) analysis revealed that significant alteration had occurred in this material during storage, resulting in the almost complete degradation of the NMP. We hypothesized that radiolytic damaged had occurred in the material. To support these concepts, we synthesized a mixed Ru-Pd nanoparticle and subjected it to irradiation in the electron microscope in an in-situ liquid cell. We demonstrated that intense radiation can lead to the decomposition of these metallic particles.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ion-Depleted Microenvironments During Lithium Deposition Revealed by Operando Freezing Cryogenic Electron Microscopy

Local structures and chemistry at active electrochemical interfaces are critical to determining safety, lifetime, and energy density in lithium metal batteries and other devices, but they are challenging to characterize at the nanoscale. We address this issue by developing operando freezing cryogenic electron microscopy (cryo-EM) to preserve battery interfaces in an active state for subsequent high-resolution characterization. We find that ion-depleted microenvironments form locally in the electrolyte adjacent to the lithium deposition interface in lithium metal batteries and are linked to heterogenous growth morphologies. These depleted environments arise locally even under conditions for which ion depletion is not predicted at steady state; this provides a mechanistic explanation for why dangerous lithium morphologies can still propagate in such systems and lead to thermal runaway. Operando freezing cryo-EM thus provides a method to directly visualize nanoscale heterogeneities that arise locally at electrochemical interfaces and play key roles in device failure.

CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS,E↗

Basal Plane Hydrogen Evolution Activity from Mixed Metal Nitride MXenes Measured by Scanning Electrochemical Microscopy

2D early transition metal carbide and nitride MXenes have intriguing properties for electrochemical energy storage and electrocatalysis. These properties can be manipulated by modifying the basal plane chemistry. Here, mixed transition metal nitride MXenes, M-Ti 4 N 3 T x (M = V, Cr, Mo, or Mn; T x = O and/or OH), are developed by modifying pristine exfoliated Ti 4 N 3 T x MXene with V, Cr, Mo, and Mn salts using a simple solution-based method. The resulting mixed transition metal nitride MXenes contain 6–51% metal loading (cf. Ti) that exhibit rich electrochemistry including highly tunable hydrogen evolution reaction (HER) electrocatalytic activity in a 0.5 m H 2 SO 4 electrolyte as follows: V-Ti 4 N 3 T x > Cr-Ti 4 N 3 T x > Mo-Ti 4 N 3 T x > Mn-Ti 4 N 3 T x > pristine Ti 4 N 3 T x with overpotentials as low as 330 mV at -10 mA cm -2 with a charge-transfer resistance of 70 O. Scanning electrochemical microscopy (SECM) reveals the electrochemical activity of individual MXene flakes. The SECM data corroborate the bulk HER activity trend for M-Ti 4 N 3 T x as well as provide the first experimental evidence that HER results from catalysis on the MXene basal plane. These electrocatalytic results demonstrate a new pathway to tune the electrochemical properties of MXenes for water splitting and related electrochemical applications.

2D materials↗

Latent Mechanisms of Polarization Switching from In Situ Electron Microscopy Observations

In situ scanning transmission electron microscopy enables observation of the domain dynamics in ferroelectric materials as a function of externally applied bias and temperature. The resultant data sets contain a wealth of information on polarization switching and phase transition mechanisms. However, identification of these mechanisms from observational data sets has remained a problem due to a large variety of possible configurations, many of which are degenerate. Here, an approach based on a combination of deep learning-based semantic segmentation, rotationally invariant variational autoencoder (VAE), and non-negative matrix factorization to enable learning of a latent space representation of the data with multiple real-space rotationally equivalent variants mapped to the same latent space descriptors is introduced. By varying the size of training sub-images in the VAE, the degree of complexity in the structural descriptors is tuned from simple domain wall detection to the identification of switching pathways. Importantly, this yields a powerful tool for the exploration of the dynamic data in mesoscopic electron, scanning probe, optical, and chemical imaging. Moreover, this work adds to the growing body of knowledge of incorporating physical constraints into the machine and deep-learning methods to improve learned descriptors of physical phenomena.

36 MATERIALS SCIENCE↗

Nanoscale Antiferromagnetic Domain Imaging using Full-Field Resonant X-ray Magnetic Diffraction Microscopy

The physical properties of magnetic materials frequently depend not only on the microscopic spin and electronic structures, but also on the structures of mesoscopic length scales that emerge, for instance, from domain formations, or chemical and/or electronic phase separations. However, experimental access to such mesoscopic structures is currently limited, especially for antiferromagnets with net zero magnetization. Here, full-field microscopy and resonant magnetic X-ray diffraction are combined to visualize antiferromagnetic (AF) domains of the spin–orbit Mott insulator Sr 2 IrO 4 with area over ≈0.1 mm 2 and with spatial resolution as high as ≈150 nm. With the unprecedented wide field of views and high spatial resolution, an intertwining of two AF domains on a length comparable to the measured average AF domain wall width of 545 nm is revealed. This mesoscopic structure comprises a substantial portion of the sample surface, and thus can result in a macroscopic response unexpected from its microscopic magnetic structure. In particular, the symmetry analysis presented in this work shows that the inversion symmetry, which is preserved by the microscopic AF order, becomes ill-defined at the mesoscopic length scale. We report this result underscores the importance of this novel technique for a thorough understanding of the physical properties of antiferromagnets.

36 MATERIALS SCIENCE↗

Facile Tensile Testing Platform for In Situ Transmission Electron Microscopy of Nanomaterials

In situ tensile testing using transmission electron microscopy (TEM) is a powerful technique to probe structure-property relationships of materials at the atomic scale. In this work, a facile tensile testing platform for in situ characterization of materials inside a transmission electron microscope is demonstrated. The platform consists of: 1) a commercially available, flexible, electron-transparent substrate (e.g., TEM grid) integrated with a conventional tensile testing holder, and 2) a finite element simulation providing quantification of specimen-applied strain. The flexible substrate (carbon support film of the TEM grid) mitigates strain concentrations usually found in free-standing films and enables in situ straining experiments to be performed on materials that cannot undergo localized thinning or focused ion beam lift-out. The finite element simulation enables direct correlation of holder displacement with sample strain, providing upper and lower bounds of expected strain across the substrate. The tensile testing platform is validated for three disparate material systems: sputtered gold-palladium, few-layer transferred tungsten disulfide, and electrodeposited lithium, by measuring lattice strain from experimentally recorded electron diffraction data. The results show good agreement between experiment and simulation, providing confidence in the ability to transfer strain from holder to sample and relate TEM crystal structural observations with material mechanical properties.

2D materials↗

Imaging Photonic Resonances within an All‐Dielectric Metasurface via Photoelectron Emission Microscopy

Dielectric metasurfaces, through volume‐type photonic resonances, enable precise control of light‐matter interactions for applications including imaging, holography, and sensing. The application space of dielectric metasurfaces has extended from infrared to visible wavelengths by incorporating high refractive index materials, such as titanium dioxide (TiO 2 ). Understanding the fundamental and fabrication limits for these applications requires metrology with nanoscale resolution, sensitivity to electromagnetic fields within the meta‐atom volume, and far‐field excitation. In this work, photoelectron emission microscopy (PEEM) is used to image field distributions of photonic resonances in a TiO 2 metasurface excited with far‐field, visible‐wavelength illumination. The local volumetric field variations within the meta‐atoms are analyzed as a function of illumination angle and polarization by comparing photoelectron images to finite‐difference time‐domain simulations. This study determines the inelastic mean free path of very low‐energy (<1 eV) photoelectrons to be 35 ± 10 nm, which is comparable to the meta‐atom height thereby highlighting PEEM sensitivity to resonances within the volume. Additionally, the simulations reveal high sensitivity of PEEM images to an in‐plane component of the illumination k ‐vector. These results demonstrate that photoelectron imaging with subwavelength resolution offers unique advantages for examining light‐matter interactions in volume‐type (as opposed to surface) photonic modes within dielectric nanophotonic structures.

electron inelastic mean free path↗

Physics Discovery in Nanoplasmonic Systems via Autonomous Experiments in Scanning Transmission Electron Microscopy

Abstract Physics‐driven discovery in an autonomous experiment has emerged as a dream application of machine learning in physical sciences. Here, this work develops and experimentally implements a deep kernel learning (DKL) workflow combining the correlative prediction of the target functional response and its uncertainty from the structure, and physics‐based selection of acquisition function, which autonomously guides the navigation of the image space. Compared to classical Bayesian optimization (BO) methods, this approach allows to capture the complex spatial features present in the images of realistic materials, and dynamically learn structure–property relationships. In combination with the flexible scalarizer function that allows to ascribe the degree of physical interest to predicted spectra, this enables physical discovery in automated experiment. Here, this approach is illustrated for nanoplasmonic studies of nanoparticles and experimentally implemented in a truly autonomous fashion for bulk‐ and edge plasmon discovery in MnPS 3 , a lesser‐known beam‐sensitive layered 2D material. This approach is universal, can be directly used as‐is with any specimen, and is expected to be applicable to any probe‐based microscopic techniques including other STEM modalities, scanning probe microscopies, chemical, and optical imaging.

42 ENGINEERING↗

Visualizing Intrinsic 3D-Strain Distribution in Gold Coated ZnO Microstructures by Bragg Coherent X-Ray Diffraction Imaging and Transmission Electron Microscopy with Respect to Piezotronic Applications

Novel devices ranging from bio magnetic field sensors to energy harvesting nano machines utilize the piezotronic effect. For optimal function, understanding the interaction of electrical and strain phenomena within the semiconductor crystal is necessary. Here, studies of a model piezotronic system are presented, consisting of a ZnO microrod coated by a thin layer of gold, which forms a Schottky contact with the piezoelectric ZnO material. Coherent X-ray diffraction imaging (CXDI) and transmission electron microscopy (TEM) are used to visualize the structure and strain distribution, showing that the ZnO microrod exhibits strains of multiple origins in the bulk and at the interface. Strain values of -6 × 10 -4 have been measured by CXDI at the ZnO/Au interface. The origin is shown to be a combination of an interface strain, possibly caused by the Schottky contact formation, and distinct, localized electrical fields inside the crystal which are assigned to electron depletion and screening in a bent ZnO/Au piezotronic rod. These findings will contribute to sensor development and to a better understanding of piezotronic applications.

36 MATERIALS SCIENCE↗

Unveiling the nanoscale architectures and dynamics of protein assembly with in situ atomic force microscopy

Proteins play a vital role in different biological processes by forming complexes through precise folding with exclusive inter- and intra-molecular interactions. Understanding the structural and regulatory mechanisms underlying protein complex formation provides insights into biophysical processes. Furthermore, the principle of protein assembly gives guidelines for new biomimetic materials with potential applications in medicine, energy, and nanotechnology. Atomic force microscopy (AFM) is a powerful tool for investigating protein assembly and interactions across spatial scales (single molecules to cells) and temporal scales (milliseconds to days). It has significantly contributed to understanding nanoscale architectures, inter- and intra-molecular interactions, and regulatory elements that determine protein structures, assemblies, and functions. This review describes recent advancements in elucidating protein assemblies with in situ AFM. We discuss the structures, diffusions, interactions, and assembly dynamics of proteins captured by conventional and high-speed AFM in near-native environments and recent AFM developments in the multimodal high-resolution imaging, bimodal imaging, live cell imaging, and machine-learning-enhanced data analysis. These approaches show the significance of broadening the horizons of AFM and enable unprecedented explorations of protein assembly for biomaterial design and biomedical research.

36 MATERIALS SCIENCE↗

Deactivation of Cu-Exchanged Automotive-Emission NH 3 -SCR Catalysts Elucidated with Nanoscale Resolution Using Scanning Transmission X-ray Microscopy

To gain insight into the underlying mechanisms of catalyst durability for the selective catalytic reduction (SCR) of NO x with an ammonia reductant, we employed scanning transmission X-ray microscopy (STXM) to study Cu-exchanged zeolites with the CHA and MFI framework structures before and after simulated 135 000-mile aging. X-ray absorption near-edge structure (XANES) measurements were performed at the Al K- and Cu L-edges. The local environment of framework Al, the oxidation state of Cu, and geometric changes were analyzed, showing a multi-factor-induced catalytic deactivation. In Cu-exchanged MFI, a transformation of Cu II to Cu I and Cu x O y was observed. We also found a spatial correlation between extra-framework Al and deactivated Cu species near the surface of the zeolite as well as a weak positive correlation between the amount of CuI and tri-coordinated Al. By inspecting both Al and Cu in fresh and aged Cu-exchanged zeolites, we conclude that the importance of the preservation of isolated Cu II sites trumps that of Brønsted acid sites for NH 3 -SCR activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Role of Gas in Determining Image Quality and Resolution During In Situ Scanning Transmission Electron Microscopy Experiments

As gas-solid heterogeneous catalytic reactions are molecular in nature, a full mechanistic understanding of the process requires atomic scale characterization under realistic operating conditions. While atomic resolution imaging has become a routine in modern high-vacuum (scanning) transmission electron microscopy ((S)TEM), both image quality and resolution nominally degrade when reaction gases are introduced. In this work, we systematically assess the effects of different gases at various pressures on the quality and resolution of images obtained at room temperature in the annular dark field STEM imaging mode using a differentially pumped (DP) gas cell. This imaging mode is largely free from inelastic scattering effects induced by the presence of gases and retains good imaging properties over a wide range of gas mass/pressures. We demonstrate the application of the ESTEM with atomic resolution images of a complex oxide alkane oxidation catalyst MoVNbTeOx (M1) immersed in light and heavy gas environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗