At least 523 records · Page 29

Measurement Accuracy and Uncertainty Analysis of the X-59 Air Data Probe Calibration Test Entry One

The X-59 is being developed to demonstrate quiet sonic boom technology. Data was obtained via two test entries in the NASA Glenn Research Center’s 8- by 6-Foot Supersonic Wind Tunnel to calibrate the X-59’s nose air data probe. The first entry tested two theoretically identical probes with the intention of one of the probes becoming the primary X-59 nose air data probe flight hardware and the other becoming a backup. A measurement accuracy and uncertainty analysis was performed on data obtained from the first test entry. The analysis showed that the uncertainties in the probe pressures were nearly identical for the two probes, with an average difference of 2.51 x 10 -5 for the non-dimensional total pressure and 2.88 x 10 -5 for the non-dimensional static pressures. The analysis also showed that the uncertainty in the probe yaw and pitch angles were 0.00034° and 0.01416°, respectively. This gives confidence in the X-59’s flight air data system.

Air Data Probe↗

Assessing Uncertainty in Solar Measurements: Key Findings From NLR's SUNI Application Across 89 Stations

The Solar Uncertainty Integrator (SUNI) study was developed by the National Laboratory of the Rockies (NLR's) to provide a standardized "bulk uncertainty processing" method for solar irradiance data, which are essential for the successful deployment of solar energy systems. This poster provides an overview of key findings from NLR's SUNI application across 89 stations.

14 SOLAR ENERGY↗

Nuclear Data to Reduce Uncertainties in Reactor Antineutrino Measurements

The large quantities of antineutrinos produced through the decay of fission fragments in nuclear reactors provide an opportunity to study the properties of these particles and investigate their use in reactor monitoring. The reactor antineutrino spectra are measured using specialized, large area detectors that detect antineutrinos through inverse beta decay, electron elastic scattering, or coherent elastic neutrino nucleus scattering; although, inverse beta decay is the only demonstrated method so far. Reactor monitoring takes advantage of the differences in the antineutrino yield and spectra resulting from uranium and plutonium fission providing an opportunity to estimate the fissile material composition in the reactor. Recent experiments reveal a deviation between the measured and calculated antineutrino flux and spectra (the reactor anomaly) indicating either the existence of yet undiscovered neutrino physics, uncertainties in the reactor source term calculation, incorrect nuclear data, or a combination of all three. To address the nuclear data that impact the antineutrino spectrum calculations and measurements, an international group of over 180 experts in antineutrino physics, reactor analysis, detector development, and nuclear data came together during the Workshop on Nuclear Data for Reactor Antineutrino Measurements (WoNDRAM) to discuss nuclear data needs and achieve concordance on a set of recommended priorities for nuclear data improvements. Three topical sessions focused on the reactor source term, the antineutrino spectrum, and the detector response, provided a forum to gain consensus amongst the participants on the most important data improvements to address two goals: 1) understand the reactor anomaly and 2) improve the ability to monitor reactors using antineutrinos. This report summarizes the outcomes of the workshop discussions and the recommendations for nuclear data efforts that reduce reactor antineutrino measurement uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncertainty Propagation from Experiment Measurements to Modeling Approaches: A Case for SMR Steam Entrainment Testing

To license new and advanced reactor designs, regulators must be convinced that their unique safety cases—relative to existing large scale reactors—have been adequately addressed by the designed reactor protection systems. In water cooled small modular reactors (SMRs), droplet entrainment in steam flow has significant implications on the progression of accident scenarios due to its compact design features, which requires representative test data applicable to SMR designs. Computer code, modeling and simulation (M&S) tools and models require adequate verification, assessment, and qualification. This includes M&S results validation against scaled empirical data within allowable uncertainty bands to gain regulatory approvals during the various stages of reactor system design, demonstration, and commercialization. However, measurement uncertainty within the empirical datasets and test data applicability ranges requires careful consideration of M&S inputs (i.e., boundary conditions, and initial conditions), and verification and validation efforts. This study focuses on uncertainty quantification in designing scaled test facilities for SMR applications with appropriate measurements and a standard data-reduction method to estimate thermal hydraulics characteristics parameters that incorporate physics phenomena of interest. In addition, this study supports the evaluation model development and assessment process using M&S that interfaces with advanced computing tools and digital twin capabilities. This will allow synchronization between experiment and modeling approaches for droplet entrainment testing and analysis, improving diagnostics, prognostics, and decision-making to accelerate regulatory approval.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Uncertainty Analysis of Instrument Calibration and Application

Experimental aerodynamic researchers require estimated precision and bias uncertainties of measured physical quantities, typically at 95 percent confidence levels. Uncertainties of final computed aerodynamic parameters are obtained by propagation of individual measurement uncertainties through the defining functional expressions. In this paper, rigorous mathematical techniques are extended to determine precision and bias uncertainties of any instrument-sensor system. Through this analysis, instrument uncertainties determined through calibration are now expressed as functions of the corresponding measurement for linear and nonlinear univariate and multivariate processes. Treatment of correlated measurement precision error is developed. During laboratory calibration, calibration standard uncertainties are assumed to be an order of magnitude less than those of the instrument being calibrated. Often calibration standards do not satisfy this assumption. This paper applies rigorous statistical methods for inclusion of calibration standard uncertainty and covariance due to the order of their application. The effects of mathematical modeling error on calibration bias uncertainty are quantified. The effects of experimental design on uncertainty are analyzed. The importance of replication is emphasized, techniques for estimation of both bias and precision uncertainties using replication are developed. Statistical tests for stationarity of calibration parameters over time are obtained.

Tripp, John S.↗

A New Modeling Approach for a Priori Uncertainties of Laser Tracker Angle Measurements

Methods for modeling the uncertainty in laser tracker angle measurements vary within the metrology industry, leading to confusion and questionable stochastic modeling for survey network adjustments and error propagation analysis. Interpreting the published laser tracker manufacturer performance specifications to determine an a priori sigma value for weighting azimuth and zenith angle measurements can be confusing and has led to differing implementations. Furthermore, this paper proposes a unique way to model survey network a priori laser tracker angular uncertainties based on laser tracker manufacturers’ published maximum permissible error (MPE) values referenced to current standards for weighting survey network measurements. This paper’s proposed model takes into account the disparate effects that pointing errors, target centering errors, and leveling errors have on azimuth and zenith angular uncertainties for measurements with steep sightings and at near ranges.

42 ENGINEERING↗

Calculating Interval Uncertainties for Calibration Standards That Drift with Time

Calibrated values of many devices exhibit predictable drift over time. To provide an uncertainty statement valid over the entire calibration interval, one must account for drift. In this article, a method of accounting for drift is proposed based on guidance in the Guide to Expression of Uncertainty in Measurement. An additional uncertainty term is computed using a linear regression of historical measurement data, which is included along with the time-of-test uncertainty. This method is evaluated by analyzing its average out-of-tolerance (OOT) rate using a Monte Carlo simulation, which results in the desired 5% average OOT rate when the total uncertainty is expanded to a 95% confidence interval.

47 OTHER INSTRUMENTATION↗

The Reduction of Random Uncertainty in Differential Temperature Measurements Using Common Leg Thermocouples

The uncertainty quantification of random error is considered for common leg thermocouples (i.e., where one thermoelement is shared along the length of the TC for all other TC junctions present). The uncertainty is presented for both a common leg and individual, separate leg thermocouples. For Type K thermocouples a reduction in uncertainty by up to 3x is capable when differential temperatures, ?T, are within 150°C, and diminishes to little to no improvement above 150°C.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Molecular structure determination: Equilibrium structure of pyrimidine (m-C 4 H 4 N 2 ) from rotational spectroscopy (reSE) and high-level ab initio calculation (re) agree within the uncertainty of experimental measurement

The pure rotational spectrum of pyrimidine (m-C 4 H 4 N 2 ), the meta-substituted dinitrogen analog of benzene, has been studied in the millimeter-wave region from 235 GHz to 360 GHz. The rotational spectrum of the ground vibrational state has been assigned and fit to yield accurate rotational and distortion constants. Over 1700 distinct transitions were identified for the normal isotopologue in its ground vibrational state and least-squares fit to a partial sextic S-reduced Hamiltonian. Transitions for all four singly substituted 13 C and 15 N isotopologues were observed at natural abundance and were likewise fit. Deuterium-enriched samples of pyrimidine were synthesized, giving access to all eleven possible deuterium-substituted isotopologues, ten of which were previously unreported. Experimental values of rotational constants and computed values of vibration–rotation interaction constants and electron-mass corrections were used to determine semi-experimental equilibrium structures (r e SE ) of pyrimidine. The r e SE structure obtained using coupled-cluster with single, double, and perturbative triple excitations [CCSD(T)] corrections shows exceptional agreement with the re structure computed at the CCSD(T)/cc-pCV5Z level (≤0.0002 Å in bond distance and ≤0.03° in bond angle). Of the various computational methods examined, CCSD(T)/cc-pCV5Z is the only method for which the computed value of each geometric parameter lies within the statistical experimental uncertainty (2σ) of the corresponding semi-experimental coordinate. The exceptionally high accuracy and precision of the structure determination is a consequence of the large number of isotopologues measured, the precision and extent of the experimental frequency measurements, and the sophisticated theoretical treatment of the effects of vibration–rotation coupling and electron mass. Taken together, these demanding experimental and computational studies establish the capabilities of modern structural analysis for a prototypical monocyclic aromatic compound.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantifying Uncertainties in Heat Capacity Measurements of Molten Salts Determined Using Differential Scanning Calorimetry

Uncertainty in specific heat capacity values of a molten salt determined by using differential scanning calorimetry (DSC) was assessed based on the precision of replicate measurements of heat flows used in the calculation and effects of corrections that are commonly made to heat flow measurements. The ratio method of determining heat capacity was applied using the results of replicate heat flow measurements made with two empty cells, a sapphire reference material, and three samples of a doped NaCl-UCl 3 salt mixture. Replicate measurements with empty cells were used to quantify the effects of system instabilities and sensitivities on the measured heat flows of sapphire and salt. The combined effects of uncertainties in individual heat flow measurements made with blank cells using this system were quantified to be 2.6 μV based on isothermal holds before and after the scan, with cell placement adding the greatest uncertainty. This value was used as the tolerance for accepting background-corrected heat flows measured with sapphire and salt to calculate the specific heat capacity. The acceptable heat flows measured for sapphire and salt over the temperature range of 540 to 725 °C resulted in calculated specific heat capacity values ranging from 0.53 to 0.91 J g −1 K −1 with an overall average value of 0.70 J g −1 K −1 and an uncertainty of 0.22 J g −1 K −1 at the 99 % confidence level. The combined uncertainty in the specific heat capacity masked detection of any effect of temperature or salt composition that occurred.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Influence of Vertical Hydrologic Exchange Flow, Channel Flow, and Biogeochemical Kinetics on CH 4 Emissions From Rivers

Abstract CH 4 emissions from inland water are highly uncertain in the current global CH 4 budget, especially for rivers and streams due to sparse measurements and the uncertainty of measurements caused by turbulent water flow. A previous study has revealed that vertical hydrologic exchange flow (VHEF) is the main regulator of CH 4 emissions from riverbed sediments. However, to what extent the understanding obtained from the plot‐scale can be extended to the reach scale and basin scale remains unknown. To address this challenge, we developed a process‐based model to estimate CH 4 flux at the air‐water interface using the attributes available in the national hydrography data set. It calculates the annual mean flux of VHEF, CH 4 production in sediments, and CH 4 transport in the river channel in a sequential manner. Model performance is evaluated by CH 4 efflux observed at the Hanford reach of the Columbia River. We show that reach‐wise sediment hydrologic and biogeochemical conditions estimated from the national hydrography data set could serve as a good indicator of CH 4 emissions from rivers. Aerobic methane oxidation and export to the downstream are the dominant ways of total CH 4 loss for the large lowland river. The hotspots of CH 4 emissions are likely to be at the reaches with fine sediments and slow channel velocity. This study demonstrates the possibility of quantifying CH 4 emissions at the reach scale and the modeling framework has the potential to be extended to the basin scale to improve estimates of CH 4 emissions from lotic inland water.

58 GEOSCIENCES↗

Impact of Irradiation-Induced Filter Heating on Calibration of NIR-Longpass-Filtered Reference Solar Cells

Reference solar cells play a crucial role in determining the performance of photovoltaic (PV) devices. In the performance calibration chain of mainstream single-junction PV technologies, common reference cell types include Si, KG-filtered Si, and GaAs cells. For emerging multijunction (MJ) PV technologies, such as CdTe/Si and perovskite/Si, Si reference cells with colored glass near-infrared-longpass (LP) filters like Schott RG-715 and 850 glass have been proposed. They offer a better spectral response that matches the bottom junctions of the emerging MJs, which could lead to lower uncertainties in performance measurements. However, this article reveals a prominent decrease in short-circuit current (ISC) during National Renewable Energy Laboratory's primary calibration over the course of minutes when using this type of LP-filtered reference cell, which could result in unacceptable measurement errors. Unlike quartz or KG filter glasses, LP colored glass filters demonstrate temperature-sensitive cut-on wavelength. When incident irradiance reaches these LP-filtered reference cells, the increased temperature due to light absorption causes a shift of the cut-on to longer wavelength. As a result, the device I SC exhibits a continuous decrease (approximately a 2.5% drop with RG850 LP filter in a 5-min duration) even when the device temperature is controlled at 25 degrees C. To address the temperature gradient issue between colored glass LP filter and the reference cell, we propose the direct integration of thin-film LP semiconductor layer on reference cells. This type of LP-filter-integrated cell has shown minimal temperature-related I SC variation and can serve as a more reliable reference cell source for accurate performance measurements.

14 SOLAR ENERGY↗

Towards Integrating Data Quality Assessments and Radiometer Uncertainty for Determining the Expanded Uncertainty of Three-Component Solar Radiation Measurements

Accurate solar irradiance data are fundamental for determining the design and performance characteristics of photovoltaic systems. The uncertainty of solar irradiance measurements depends on many factors including radiometer design, calibration, installation, maintenance, and operational environment. The key contributors to this uncertainty can be classified as the measurement uncertainty of a particular radiometer and the operational uncertainty determined for the time of measurement. Radiometer measurement uncertainty estimates (U R ) can be based on well-established methods used as part of the radiometer calibration process. Estimates of operational uncertainties (U o ) require consideration of additional site-specific factors that affect data quality. A method is needed for establishing the accuracy of solar irradiance data by integrating an existing data quality process and measurement uncertainty estimates for specific radiometers. An algorithm has been developed to integrate data quality analyses and measurement uncertainty estimates for three-component solar irradiance data: global horizontal (total hemispheric) irradiance, direct normal (beam) irradiance, and diffuse horizontal (sky) irradiance collected at one- to 60-minute intervals. The algorithm has been tested using one-minute irradiance measurements. The goal of the project is to distribute a user-friendly software package based on the new algorithm.

data integrity↗

Uncertainty analysis of PIV measurements in bubbly flows considering sampling and bubble effects with ray optics modeling

In this report, a modeling-based approach is developed to investigate the external sources of uncertainty in particle image velocimetry (PIV) measurements for two-phase bubbly flows. Primarily relied on ray optics modeling, this study focuses on the uncertainty in PIV measurements due to bubble-induced light distortion. In addition, the uncertainty due to sampling is also considered through synthetic PIV images generated from Monte Carlo sampling. Based on a PIV-planar laser induced florescence (PLIF) measurement system, three case studies are performed and discussed, considering respectively the sampling effect, bubble effect, and the combination of these two effects. These case studies confirm the validity of the ray optics modeling in obtaining accurate particle images through a benchmark test. Furthermore, it is also found that the bubble effect could significantly influence the particle images. On the other hand, the result of the case study with synthetic PIV images indicates that the bubble effect on particle images can be minimized by removing “outliers” in the obtained velocity vector field through a multi-pass post-processing procedure. However, the uncertainty of the velocity measurements will still increase.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗