Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

The direct measurement of the 3 3P0-3 3P1 fine-structure interval and the gJ-factor of atomic silicon by laser magnetic resonance

The J - 1 fine structure interval and the g-factor of the 3P1 state have been determined with high precision in the present laser magnetic resonance measurements of the ground 3p2 3P multiplet of atomic Si. Delta-E(3P1-3P0) = 2,311,755.6(7) MHz, and gJ(3P1) = 1.500830(70). Single-configuration calculations of gJ for 3P1 and 3P2 yield a value for the latter which, at 1.501095, is noted to differ by an unexpectedly large margin from the experimental value.

Evenson, K. M.↗

Improved Particle Confinement with Resonant Magnetic Perturbations in DIII-D Tokamak H-Mode Plasmas

Experiments on the DIII-D tokamak have identi fied a novel regime in which applied resonant magnetic perturbations (RMPs) increase the particle con finement and overall performance. This work details a robust range of counter-current rotation over which RMPs cause this density pump-in effect for high con finement (H-mode) plasmas. The pump-in is shown to be caused by a reduction of the turbulent transport and to be correlated with a change in the sign of the induced neoclassical transport. Furthermore, this novel reversal of the RMP induced transport has the potential to signifi cantly improve reactor relevant, three-dimensional magnetic con finement scenarios.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-dimensional nuclear magnetic resonance spectroscopy with a microfluidic diamond quantum sensor

Quantum sensors based on nitrogen-vacancy centers in diamond have emerged as a promising detection modality for nuclear magnetic resonance (NMR) spectroscopy owing to their micrometer-scale detection volume and noninductive-based detection. A remaining challenge is to realize sufficiently high spectral resolution and concentration sensitivity for multidimensional NMR analysis of picoliter sample volumes. Here, we address this challenge by spatially separating the polarization and detection phases of the experiment in a microfluidic platform. We realize a spectral resolution of 0.65 ± 0.05 Hz, an order-of-magnitude improvement over previous diamond NMR studies. We use the platform to perform two-dimensional correlation spectroscopy of liquid analytes within an effective ~40-picoliter detection volume. The use of diamond quantum sensors as in-line microfluidic NMR detectors is a major step toward applications in mass-limited chemical analysis and single-cell biology.

Science & Technology - Other Topics↗

Antiferromagnetic order in Co-doped Fe 5 GeTe 2 probed by resonant magnetic x-ray scattering

The quasi-two-dimensional van der Waals magnet Fe 5-δ GeTe 2 has emerged as a promising platform for electronic and spintronic functionalities at room temperature, owing to its large ferromagnetic ordering temperature T C ≈ 315 K. Interestingly, by cobalt (Co) substitution of iron in F5GT, i.e., (Fe 1-x Co x ) 5-δ GeTe 2 (Co-F5GT), not only can its magnetic transition temperature be further enhanced, but the magnetic and structural ground states can also be tuned. Specifically, an antiferromagnetic (AFM) order is induced beyond the Co doping level x ≥ 0.4. Here, in this work, we investigate the magnetic properties of a Co-F5GT single crystal at x = 0.45(1), by utilizing the element-specific, resonant magnetic x-ray scattering technique. Our study reveals an A-type, Ising-like AFM ground state, with a transition temperature T N ≈ 340 K. In addition, our work unveils an important contribution from Co magnetic moments to the magnetic order. The application of the in-plane magnetic fields gradually polarizes the spin moments along the field direction, but without inducing incommensurate spin texture(s).

36 MATERIALS SCIENCE↗

Graphene oxide-Fe{sub 3}O{sub 4} nanoparticle composite with high transverse proton relaxivity value for magnetic resonance imaging

The potential of graphene oxide–Fe{sub 3}O{sub 4} nanoparticle (GO-Fe{sub 3}O{sub 4}) composite as an image contrast enhancing material in magnetic resonance imaging has been investigated. Proton relaxivity values were obtained in three different homogeneous dispersions of GO-Fe{sub 3}O{sub 4} composites synthesized by precipitating Fe{sub 3}O{sub 4} nanoparticles in three different reaction mixtures containing 0.01 g, 0.1 g, and 0.2 g of graphene oxide. A noticeable difference in proton relaxivity values was observed between the three cases. A comprehensive structural and magnetic characterization revealed discrete differences in the extent of reduction of the graphene oxide and spacing between the graphene oxide sheets in the three composites. The GO-Fe{sub 3}O{sub 4} composite framework that contained graphene oxide with least extent of reduction of the carboxyl groups and largest spacing between the graphene oxide sheets provided the optimum structure for yielding a very high transverse proton relaxivity value. It was found that the GO-Fe{sub 3}O{sub 4} composites possessed good biocompatibility with normal cell lines, whereas they exhibited considerable toxicity towards breast cancer cells.

36 MATERIALS SCIENCE↗

Diffusion-weighted Magnetic Resonance Imaging in Non-traumatic Vertebral Collapse: A Relook Into Its Utility in Making the Diagnosis in a Population Where Infections of Spine Are a Common Cause

Magnetic resonance imaging (MRI) is the imaging investigation of choice in vertebral collapse. In this study, we considered various MRI features and appearance based on morphological features, signal intensity, contrast enhancement characteristics, and diffusion-weighted imaging (DWI) of various types of non-traumatic vertebral collapse for differentiating benign from malignant causes and its role in differentiating cases of infectious causes of vertebral collapse from malignant causes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

From Computed Tomography–Guided to Magnetic Resonance Imaging–Guided Intracavitary Brachytherapy for Cervical Cancer: What Do the Key Stakeholders Have to Say about the Transition?

International brachytherapy consortiums are advocating for the incorporation of magnetic resonance imaging (MRI) into the cervical brachytherapy process as a standard-of-care. Although some evaluations have been performed to quantify the effect on procedural time, little is known about the views and experiences of key stakeholders during the transition from computed tomography to MR-guided brachytherapy. This qualitative research project explored insights from key stakeholders related to a change in the gynaecologic brachytherapy process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gyrokinetic understanding of the edge pedestal transport driven by resonant magnetic perturbations in a realistic divertor geometry

Self-consistent simulations of neoclassical and electrostatic turbulent transport in a DIII-D H-mode edge plasma under resonant magnetic perturbations (RMPs) have been performed using the global total-f gyrokinetic particle-in-cell code x-point gyrokinetic code (XGC), in order to study density pump-out and electron heat confinement. The RMP field is imported from the extended magneto-hydrodynamics code M3D-C1, taking into account the linear two-fluid plasma response. With both neoclassical and turbulence physics considered together, the XGC simulation reproduces two key features of experimentally observed edge transport under RMPs: increased radial particle transport in the pedestal region that is sufficient to account for the experimental pump-out rate and suppression of the electron heat flux in the steepest part of the edge pedestal. In the simulation, the density fluctuation amplitude of modes moving in the electron diamagnetic direction increases due to interaction with RMPs in the pedestal shoulder and outward, while the electron temperature fluctuation amplitude decreases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gyrokinetic understanding of the edge pedestal transport driven by resonant magnetic perturbations in a realistic divertor geometry

Self-consistent simulations of neoclassical and electrostatic turbulent transport in a DIII-D H-mode edge plasma under resonant magnetic perturbations (RMPs) have been performed using the global total-f gyrokinetic particle-in-cell code XGC, in order to study density-pump out and electron heat confinement.The RMP field is imported from the extended magneto-hydrodynamics (MHD) code M3D-C1, taking into account the linear two-fluid plasma response.With both neoclassical and turbulence physics considered together, the XGC simulation reproduces two key features of experimentally observed edge transport under RMPs: increased radial particle transport in the pedestal region that is sufficient to account for the experimental pump-out rate, and suppression of the electron heat flux in the steepest part of the edge pedestal.In the simulation, the density fluctuation amplitude of modes moving in the electron diamagnetic direction increases due to interaction with RMPs in the pedestal shoulder and outward, while the electron temperature fluctuation amplitude decreases.

DIII-D↗

Far-infrared laser magnetic resonance of vibrationally excited CD2

The detection of 13 rotational transitions in the first excited bending state (010) of CD2 using the technique of far-infrared laser magnetic resonance spectroscopy is reported. Molecular parameters for this state are determined from these new data together with existing infrared observations of the v(2) band. Additional information on the ground vibrational state (000) is also provided by the observation of a new rotational transition, and this is combined with existing data to provide a refined set of molecular parameters for the CD2 ground state. One spectrum has been observed that is assigned as a rotational transition within the first excited symmetric stretching state (100) of CD2. These data will be of use in refining the structure and the potential function of the methylene radical.

Evenson, K. M.↗

Accurate determination of the fine-structure intervals in the 3P ground states of C-13 and C-12 by far-infrared laser magnetic resonance

Accurate values are presented for the fine-structure intervals in the 3P ground state of neutral atomic C-12 and C-13 as obtained from laser magnetic resonance spectroscopy. The rigorous analysis of C-13 hyperfine structure, the measurement of resonant fields for C-12 transitions at several additional far-infrared laser frequencies, and the increased precision of the C-12 measurements, permit significant improvement in the evaluation of these energies relative to earlier work. These results will expedite the direct and precise measurement of these transitions in interstellar sources and should assist in the determination of the interstellar C-12/C-13 abundance ratio.

Cooksy, A. L.↗

Pretreatment Evaluation of Microcirculation by Dynamic Contrast-Enhanced Magnetic Resonance Imaging Predicts Survival in Primary Rectal Cancer Patients

Purpose: To investigate the prognostic value of the perfusion index (PI), a microcirculatory parameter estimated from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), which integrates information on both flow and permeability, to predict overall survival and disease-free survival in patients with primary rectal cancer. Methods and Materials: A total of 83 patients with stage cT3 rectal cancer requiring neoadjuvant chemoradiation were investigated with DCE-MRI before start of therapy. Contrast-enhanced dynamic T{sub 1} mapping was obtained, and a simple data analysis strategy based on the calculation of the maximum slope of the tissue concentration–time curve divided by the maximum of the arterial input function was used as a measure of tumor microcirculation (PI), which integrates information on both flow and permeability. Results: In 39 patients (47.0%), T downstaging (ypT0-2) was observed. During a mean (±SD) follow-up period of 71 ± 29 months, 58 patients (69.9%) survived, and disease-free survival was achieved in 45 patients (54.2%). The mean PI (PImean) averaged over the group of nonresponders was significantly higher than for responders. Additionally, higher PImean in age- and gender-adjusted analyses was strongly predictive of therapy nonresponse. Most importantly, PImean strongly and significantly predicted disease-free survival (unadjusted hazard ratio [HR], 1.85 [ 95% confidence interval, 1.35-2.54; P<.001)]; HR adjusted for age and sex, 1.81 [1.30-2.51]; P<.001) as well as overall survival (unadjusted HR 1.42 [1.02-1.99], P=.040; HR adjusted for age and sex, 1.43 [1.03-1.98]; P=.034). Conclusions: This analysis identifies PImean as a novel biomarker that is predictive for therapy response, disease-free survival, and overall survival in patients with primary locally advanced rectal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic Substitute Computed Tomography Generation and Contouring for Magnetic Resonance Imaging (MRI)-Alone External Beam Radiation Therapy From Standard MRI Sequences

Purpose: To validate automatic substitute computed tomography CT (sCT) scans generated from standard T2-weighted (T2w) magnetic resonance (MR) pelvic scans for MR-Sim prostate treatment planning. Patients and Methods: A Siemens Skyra 3T MR imaging (MRI) scanner with laser bridge, flat couch, and pelvic coil mounts was used to scan 39 patients scheduled for external beam radiation therapy for localized prostate cancer. For sCT generation a whole-pelvis MRI scan (1.6 mm 3-dimensional isotropic T2w SPACE [Sampling Perfection with Application optimized Contrasts using different flip angle Evolution] sequence) was acquired. Three additional small field of view scans were acquired: T2w, T2*w, and T1w flip angle 80° for gold fiducials. Patients received a routine planning CT scan. Manual contouring of the prostate, rectum, bladder, and bones was performed independently on the CT and MR scans. Three experienced observers contoured each organ on MRI, allowing interobserver quantification. To generate a training database, each patient CT scan was coregistered to their whole-pelvis T2w using symmetric rigid registration and structure-guided deformable registration. A new multi-atlas local weighted voting method was used to generate automatic contours and sCT results. Results: The mean error in Hounsfield units between the sCT and corresponding patient CT (within the body contour) was 0.6 ± 14.7 (mean ± 1 SD), with a mean absolute error of 40.5 ± 8.2 Hounsfield units. Automatic contouring results were very close to the expert interobserver level (Dice similarity coefficient): prostate 0.80 ± 0.08, bladder 0.86 ± 0.12, rectum 0.84 ± 0.06, bones 0.91 ± 0.03, and body 1.00 ± 0.003. The change in monitor units between the sCT-based plans relative to the gold standard CT plan for the same dose prescription was found to be 0.3% ± 0.8%. The 3-dimensional γ pass rate was 1.00 ± 0.00 (2 mm/2%). Conclusions: The MR-Sim setup and automatic sCT generation methods using standard MR sequences generates realistic contours and electron densities for prostate cancer radiation therapy dose planning and digitally reconstructed radiograph generation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nonlocal Means Denoising of Self-Gated and k-Space Sorted 4-Dimensional Magnetic Resonance Imaging Using Block-Matching and 3-Dimensional Filtering: Implications for Pancreatic Tumor Registration and Segmentation

Purpose: To denoise self-gated k-space sorted 4-dimensional magnetic resonance imaging (SG-KS-4D-MRI) by applying a nonlocal means denoising filter, block-matching and 3-dimensional filtering (BM3D), to test its impact on the accuracy of 4D image deformable registration and automated tumor segmentation for pancreatic cancer patients. Methods and Materials: Nine patients with pancreatic cancer and abdominal SG-KS-4D-MRI were included in the study. Block-matching and 3D filtering was adapted to search in the axial slices/frames adjacent to the reference image patch in the spatial and temporal domains. The patches with high similarity to the reference patch were used to collectively denoise the 4D-MRI image. The pancreas tumor was manually contoured on the first end-of-exhalation phase for both the raw and the denoised 4D-MRI. B-spline deformable registration was applied to the subsequent phases for contour propagation. The consistency of tumor volume defined by the standard deviation of gross tumor volumes from 10 breathing phases (σ-GTV), tumor motion trajectories in 3 cardinal motion planes, 4D-MRI imaging noise, and image contrast-to-noise ratio were compared between the raw and denoised groups. Results: Block-matching and 3D filtering visually and quantitatively reduced image noise by 52% and improved image contrast-to-noise ratio by 56%, without compromising soft tissue edge definitions. Automatic tumor segmentation is statistically more consistent on the denoised 4D-MRI (σ-GTV = 0.6 cm{sup 3}) than on the raw 4D-MRI (σ-GTV = 0.8 cm{sup 3}). Tumor end-of-exhalation location is also more reproducible on the denoised 4D-MRI than on the raw 4D-MRI in all 3 cardinal motion planes. Conclusions: Block-matching and 3D filtering can significantly reduce random image noise while maintaining structural features in the SG-KS-4D-MRI datasets. In this study of pancreatic tumor segmentation, automatic segmentation of GTV in the registered image sets is shown to be more consistent on the denoised 4D-MRI than on the raw 4D-MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Performance of Radiographic Criteria for Bone Malignancy When Applied to Computed Tomography and Magnetic Resonance Imaging

The conventional radiologic features that differentiate benign from malignant bone lesions were originally described using radiography (x-ray [XR]). When evaluating sectional imaging studies such as magnetic resonance imaging (MRI) and computed tomography (CT), one may apply these principles to identify malignant bone lesions. The aim of this study was to evaluate the performances of these radiographic features for detecting malignity when applied to CT and MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structure and Dynamics of Brachypodium Primary Cell Wall Polysaccharides from Two-Dimensional 13 C Solid-State Nuclear Magnetic Resonance Spectroscopy

The polysaccharide structure and dynamics in the primary cell wall of the model grass Brachypodium distachyon are investigated for the first time using solid-state nuclear magnetic resonance (NMR). While both grass and non-grass cell walls contain cellulose as the main structural scaffold, the former contains xylan with arabinose and glucuronic acid substitutions as the main hemicellulose, with a small amount of xyloglucan (XyG) and pectins, while the latter contains XyG as the main hemicellulose and significant amounts of pectins. We labeled the Brachypodium cell wall with 13 C to allow two-dimensional (2D) 13 C correlation NMR experiments under magic-angle spinning. Well-resolved 2D spectra are obtained in which the 13 C signals of cellulose, glucuronoarabinoxylan (GAX), and other matrix polysaccharides can be assigned. The assigned 13 C chemical shifts indicate that there are a large number of arabinose and xylose linkages in the wall, and GAX is significantly branched at the developmental stage of 2 weeks. 2D 13 C– 13 C correlation spectra measured with long spin diffusion mixing times indicate that the branched GAX approaches cellulose microfibrils on the nanometer scale, contrary to the conventional model in which only unbranched GAX can bind cellulose. The GAX chains are highly dynamic, with average order parameters of 0.4. Biexponential 13 C T 1 and 1 H T 1ρ relaxation indicates that there are two dynamically distinct domains in GAX: the more rigid domain may be responsible for cross-linking cellulose microfibrils, while the more mobile domain may fill the interfibrillar space. This dynamic heterogeneity is more pronounced than that of the non-grass hemicellulose, XyG, suggesting that GAX adopts the mixed characteristics of XyG and pectins. Moderate differences in cellulose rigidity are observed between the Brachypodium and Arabidopsis cell walls, suggesting different effects of the matrix polysaccharides on cellulose. These data provide the first molecular-level structural information about the three-dimensional organization of the polysaccharides in the grass primary wall.

36 MATERIALS SCIENCE↗

Three-dimensional equilibria and island energy transport due to resonant magnetic perturbation edge localized mode suppression on DIII-D

In this research, we conducted experiments in the DIII-D tokamak that show that the plasma responds to resonant magnetic perturbations (RMPs) with toroidalmode numbers of n=2 and n=3 without field line reconnection, consistent with resistive magnetohydrodynamic predictions, while a strong nonlinear bifurcation is apparent when edge localized modes(ELMs) are suppressed. The magnetic response associated with this bifurcation is localized to the high field side of the machine and exhibits a dominant n=1 component despite the application of a constant amplitude, slowly toroidally rotating, n=2 applied field. The n=1 mode is born locked to the vacuum vessel wall, while the n=2 mode is entrained to the rotating field. Based on these magnetic response measurements and Thomson scattering measurements of flattening of the electron temperature profile, it is likely that these modes are magnetic island chains near the H-mode pedestal. The reduction in ∇Te occurs near the q=4 and 5 rational surfaces, suggesting five unique islands are possible (m=8, 9, or 10 for n=2) and (m=4 or 5 for n=1). In all cases, the island width is estimated to be 2–3 cm. The Chang-Callen calculated confinement degradation due to the presence of an individual island of this size is 8%–12%, which is close to the 13%–14% measured between the ELMs and suppressed states. In conclusion, this suggests that edge tearing modes may alter the pedestal causing peeling-ballooning stability during RMP induced ELM suppression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗